• Title/Summary/Keyword: Breaker Noise

Search Result 23, Processing Time 0.023 seconds

Arc Extinguishment for Low-voltage DC (LVDC) Circuit Breaker by PPTC Device (PPTC 소자를 사용한 저전압 직류차단기의 아크소호기술)

  • Kim, Yong-Jung;Na, Jeaho;Kim, Hyosung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.5
    • /
    • pp.299-304
    • /
    • 2018
  • An ideal circuit breaker should supply electric power to loads without losses in a conduction state and completely isolate the load from the power source by providing insulation strength in a break state. Fault current is relatively easy to break in an Alternating Current (AC) circuit breaker because the AC current becomes zero at every half cycle. However, fault current in DC circuit breaker (DCCB) should be reduced by generating a high arc voltage at the breaker contact point. Large fire may occur if the DCCB does not take sufficient arc voltage and allows the continuous flow of the arc fault current with high temperature. A semiconductor circuit breaker with a power electronic device has many advantages. These advantages include quick breaking time, lack of arc generation, and lower noise than mechanical circuit breakers. However, a large load capacity cannot be applied because of large conduction loss. An extinguishing technology of DCCB with polymeric positive temperature coefficient (PPTC) device is proposed and evaluated through experiments in this study to take advantage of low conduction loss of mechanical circuit breaker and arcless breaking characteristic of semiconductor devices.

The Subjective Response for Impulsive Sound - Focusing on the Construction Noise - (충격성 소음에 대한 주관적 반응 - 건설공사장 소음을 중심으로 -)

  • Kim, Deuk-Sung;Chun, Hyung-Jun;Chang, Seo-Il
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.7
    • /
    • pp.746-755
    • /
    • 2008
  • This research presents a laboratory study on subjective response of impulsive sound caused by construction site (breaker and blasting). The sources are sampled from outdoor noise and their levels range from 40 to 75 dBA at the interval of 5 dBA. The noise unit is based on A-weighted sound exposure level(ASEL; $L_{AE}$). To make equal ASEL of listening level, finite impulse response(FIR) filter is applied to the originally sampled source to include the effect of propagation attenuation. Sixty-three subjects, forty-two males and twenty-one female, between 18 and 29 years of age, participated in the experiment. The evaluation method of jury test adopted a semantic difference method(SDM). In the test results for impulsive noise, the subjective response of blasting noise was higher than that of breaker noise. The result of %HA that has been combined responses of the three methods except for pink-noise was executed by regression analysis and was shown as the following equation.: $%HA=746.53/(1+{\exp} (L_{AE}-93.3))+0.34$.

A Study on the Excavation Method Near Fish Farms and Livestock (양만장 및 가축사육시설 인접지역 암굴착공법 검토에 관한 연구)

  • Lim, Dae-Kyu;Shin, Young-Cheol;Jun, Yang-Bae
    • Explosives and Blasting
    • /
    • v.31 no.1
    • /
    • pp.23-32
    • /
    • 2013
  • Construction vibration such as explosive blast, hydraulic breaker, vibratory roller, pile driving noise and so on, injuries in areas around the construction sites. In particular, underwater sound caused by ground vibration is propagation such as structure borne noise. Vibration and underwater sound due to construction activities may cause injury to river, sea or land fish farms near construction sites. The purpose of present study is to measure the sound pressure level and frequency analysis of the underwater noise generated by ground vibration(Blasting, hydraulic crawler drill, hydraulic breaker, vibratory roller). Underwater noise were monitoring by a hydrophone (TC 4013) and recorded, analysis were made using a by software (Prosig).

Development of EMC Filter In the High Powered Breaker

  • Kim, Eun-Mi;Jeon, Mi-Hwa;Kim, Dong-Il;Ahn, Young-Sup
    • Journal of electromagnetic engineering and science
    • /
    • v.9 no.2
    • /
    • pp.53-60
    • /
    • 2009
  • Remarkable developments in the electric and electronic industry have given people's daily life much more convenience and abundance. However, in electrical communication, or electric and electronic fields, making electrical and electronic devices more functional, more integrated, and faster have put electromagnetic interference(EMI) into more complex forms, and lots of problems such as interruption, malfunction, or interference by noise between electrical communication systems occurs every day. In this research, the electromagnetic compatibility(EMC) filter in the high powered breaker was designed and fabricated as a counter measure. The filter attenuated noise more than 20${\sim}$50 dB in the range of 10 MHz${\sim}$1.5 GHz. And, when the electric fast transient(EFT) of 4 kV in the level 4 of IEC 61000-4-4 was induced, it was soon suppressed to 600 V.

Site Mitigation Plan for Noise Sources from Construction Sites by Developing Movable Noise Barriers (건설공사장 이동식 방음시설물의 음향특성)

  • Lee, Sung Chan;Chung, Jin Yun;Im, Jung Bin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.1
    • /
    • pp.58-64
    • /
    • 2015
  • There are a lot of different types of noise from construction site and it depends on construction stage, equipment type and number of operating equipments. The problem is that the almost noise from construction site is high level and some kinds of noise levels are over 100 dB. In addition, if construction site is located in downtown, there are a few options to reduce noise level. Therefore several site mitigation plans were developed to reduce different types of construction noises such as breaker work, gang form and asphalt saw. They were applied in site and evaluated noise reduction performance. The test result of site insertion loss was between 4~8 dB depends on the equipment and type of work.

Optimal Design of a Shield in Vacuum Interrupter (진공 인터럽터의 쉴드 형상 최적설계)

  • Choi, Seung-Kil;Kim, Kyu-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.4
    • /
    • pp.374-380
    • /
    • 2007
  • In this paper a nobel optimum design method is presented for a shield in a vacuum interrupter which is equipped in switchgear to improve its electric insulation capability. The design of Taguchi experiment method which is based on the results by finite element method is used to find optimum design conditions. The important design factors are chosen at first and the concept of signal to noise ratio is applied to evaluate the vacuum interrupter performance, and the optimal values of each parameters are determined. From the results of various analyses, it is shown that the shield plate in circuit circuit breaker compartment of switchgear can reduce the concentration of electric field intensity. This method is very useful to design the construction of a shield in a short time. Consequently, the insulation capability of circuit breaker compartment in a gas insulated switchgear is improved by adopting an additional optimized shaped shield.

Case Study of Blasting Vibration and Noise in Public Resentment Area (민원발생시 발파진동.소음의 처리사례에 관한 연구)

  • 안명석;최영천;박종남;목연수
    • Explosives and Blasting
    • /
    • v.17 no.3
    • /
    • pp.13-22
    • /
    • 1999
  • It Is indispensible to cause vibration, noise and dust to blasting and breaker operations. Since the control of these factors is supposed to be extremely difficult, the claim of compensation for material and mental damages are getting increased. Economically feasible blasting operation with controlling vibration and noise can be achieved by establishment of science-based plan, accurate operation and responsible inspection, and the application of efficient management system. It must also be remarked that the relevant applied without prejudice by the operator, and the law and regulation should be applied without prejudice by the authority concerned. In addition, the public claim against operators should be investigated in detail and the prosecution should be made under the careful onside-ration of scientific and reasonable conception. Finally, it is strongly suggested that the operations, public and authorities should make great efforts to develop higher technology in order to expand our construction market, to overseas.

  • PDF

A STUDY ON THE DEVELOP-MENT OF HIGH QUALITY ELB. (고품질 누전차단기 개발에 관한 연구)

  • Kwang, W.K.;Kim, H.Y.;Hong, J.W.;Sohn, S.K.;Byon, Y.B.
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.833-836
    • /
    • 1988
  • In this paper, we introduced high quality earth leakage breaker(ELB). We improved performances of the ELB by strengthening the environmental stress. We suggested that it have the electromagnetic noise filter, finally high sensitive ZCT for asymmetric fault conditions (including do component).

  • PDF

A Study on Design of EMC Filter in the High Powered Breaker (대전력용 차단기 내의 EMC 필터 설계에 관한 연구)

  • Kim, Eun-Mi;Jeon, Mi-Hwa;Kim, Dong Il
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.139-142
    • /
    • 2009
  • Rapid developments in the field of electronic communication have given people's daily life much more convenience and abundance. However, making precise electrical and electronic devices and control systems lighter, smaller, and faster have caused lots of problems such as interference of external electric source, malfunction brought by electric fast transient(EFT), and influence on human body. In this research, the EMC filter in the high powered breaker was designed and fabricated as a countermeasure. The filter attenuated noise more than 30 ~ 75 dB in the range of 10 MHz ~ 1.5 GHz. And, when the EFT of 4 kV in the level 4 of IEC 61000-4-4 was induced, it was soon suppressed to 600 V.

  • PDF

A Study on Practicalization of Low Vibration New KINRECKER-II (미진동 발파용 New KINECKER-II 실용화에 관한 연구)

  • Jang, Seung-Ho;Park, Hee-Won;Lim, Jung-Hyuk;Lee, Chang-Yeop;Ahn, Bong-Do;Kang, Dae-Woo;Lee, Ha-Young
    • Explosives and Blasting
    • /
    • v.35 no.1
    • /
    • pp.43-52
    • /
    • 2017
  • Mountain and hill areas occupy by more than 70% in South Korea and Rock drilling should be applied in order to reduce noisy & vibration from massive civil engineering business such as road expansion, high-way construction, subway construction and construction of site renovation such as a newly-built & re-development of apartment, newly-built of high-rising building in downtown area. As Blasting noise & vibration such as vibration, noise, fly rock etc caused by blasting operation from large small scale construction occurs, neighboring residents who demand the compensation file a civil complaint so that the business reach a deadlock. As the excavation method for these areas, There are blasting of micro-vibration, mechanical excavation method(Rock splitter, Breaker etc), similar blasting method(plasma, gel fragmentation etc) to date. In this study, we are trying to find the feature & performance which get improved economic feasibility & construct ability through improving sympathetic detonation of New KINECKER-I used in blasting of micro-vibration & formulation and would provide convenience for use by introducing standard blasting pattern & construction method. Also, checked and confirmed all the blasting with connecting cap has been cleary detonated.