디지털 신호 처리 기반 저압 차단기용 전자식 계전기 개발 (A Development of Electronic Type Relay for Low Voltage Circuit Breaker based on Digital Signal Processing)

  • 박병철;손종만;송성근;신중린
    • 조명전기설비학회논문지
    • /
    • 제27권5호
    • /
    • pp.81-88
    • /
    • 2013
  • A low voltage circuit breaker protects electrical equipments from over current and short faults of system by cutting the power supply. The breaker use a thermal magnetic type trip device from the past. In recent years, electronic type relays are applied due to useful functions and services. The purpose of this development is full digitalizing of relay functions of a low voltage breaker. It includes separation of current sensor from current transformer, digital signal processing, high speed relaying, and voltage measuring for power meter. The suggestions are tested and implemented by making prototype and testing its all relay functions.

자기적 아크소호 기법을 이용한 직류 차단기 개발 (Development of DC Circuit Breaker using Magnet Arc Extinguisher)

  • 이성민;김효성
    • 전력전자학회논문지
    • /
    • 제17권1호
    • /
    • pp.21-26
    • /
    • 2012
  • In recent years, DC distribution systems are becoming hot issue due to the increase in digital loads and DC generation systems according to the expansion of renewable energy technologies. However, removing the fault current in DC grids is comparably difficult since the current in DC grids has no zero-crossing point like in AC grids. Thus, developing dedicated DC circuit breakers for DC grids is necessary to get safety for people and electrical facilities. This paper proposes magnet arc extinguishing method to develop a 300[$V_{DC}$]/10[A] DC circuit breaker. The performance of the proposed DC circuit breaker was verified by an experimental circuit breaker test system built in this research.

Puffer식 차단기 내의 냉가스 유동 해석 (Analysis of the Cold Gas Flow in Puffer Type Circuit Breaker)

  • 김홍규;신승록;정현교;김두성;권기영
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권4호
    • /
    • pp.233-239
    • /
    • 2000
  • There are many difficult problems in analyzing the gas flow in puffer type circuit breaker such as complex geometry, moving boundary, shock wave and so on. To predict the interruption performance accurately, these should be considered in the simulation. In this paper, the analysis procedure of the cold gas flow in the circuit breaker is presented. Euler equation is solved by FVFLIC method which is an explicit time difference scheme for an unsteady flow computation. Moving boundaries are treated with a cell elimination-addition technique. The pressure and density in front of piston are calculated from the rate of the cell volume change. The presented method is applied to the real circuit breaker model and the pressure in front of the piston is good agreement with the experimental one.

  • PDF

단락시험에서 후비보호차단기와 투입스위치의 중요 역할 (The study of a primary role of Back up Breaker and Making Switch for Short Circuit Test)

  • 김선구;김선호;김원만;노창일;이동준;정흥수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.915-916
    • /
    • 2007
  • There are many equipments for the Short Circuit Test, for example Short Circuit Generator, Induction Motor, Sequence Timer, Exciter, CLR, Back Up Breaker, Making Switch and TRV etc. Especially Back up Breaker and Making Switch are very important equipments to test the short circuit test. A role of a Back up Breaker is to break high-voltage and high-current for short circuit test and a Making Switch should be operated always same speed/time and kept electrical-mechanical characteristics to make the voltage and current of short circuit test. This study introduces to the short circuit test also to kinds, principal movements and compare them of Back up Breaker and Making Switch.

  • PDF

초전도 코일을 이용한 DC 회로 차단기의 차단 능력 특성 (Characteristics of Interruption Ability in DC Circuit Breaker using Superconducting Coil)

  • 정인성;최혜원;윤정일;최효상
    • 전기학회논문지
    • /
    • 제68권1호
    • /
    • pp.215-219
    • /
    • 2019
  • Development of DC interruption technology is being studied actively for enhanced DC grid reliability and stability. In this study, coil type superconductor DC circuit breaker was proposed as DC interruption. It is integration technology that combined current-limiting technique using superconductor and cut-off technique using mechanical DC circuit breaker. Superconductor was applied to the coil type. In simulation, Mayr arc model was applied to realize the arc characteristic in the mechanical DC circuit breaker. PSCAD/EMTDC had used to model and perform the simulation. To find out the protection range of coil type superconductor DCCB, the working operation have analyzed based on the rated voltage of DCCB. The results confirmed that, according to apply the limiting device, the protection range was increased in twice. Therefore, the probability of failure of interruption has lowered significantly.

회로 차단기 절연파괴로 인한 직류 전기철도 화재 사고사례 분석 (Analysis of Fire Accident on DC Electric Traction Vehicles Caused by Breakdown in the Line Breaker)

  • 박남규;송재용;고재모;김진표;남정우
    • 한국안전학회지
    • /
    • 제32권6호
    • /
    • pp.16-21
    • /
    • 2017
  • Fire or electrical problem while DC electric traction vehicle operation caused by various reasons can lead to not only suspension of the operation, but also severe aftermath such as massive casualty. In this paper, fire analysis on DC electric traction vehicle caused by electrical breakdown on line breaker, which is in connection with the power supply, is presented. When the electric arc, the by-product of frequent line breaker operation, is not fully diminished, it leads to electrical breakdown and fire. Especially, electrical breakdown can be easily induced by the open-and-close operation of inner contractor inside line breaker, eventually followed by ground fault and generation of transient current. Electric arc is consequent on the ground fault and acts as possible ignition source, leading to fire. Also, during the repetitive operation of the line breaker, the contactor is separated each other and some copper powder is generated, and the copper powder provided breakdown path, resulting in fire.

A New Reclosing and Re-breaking DC Thyristor Circuit Breaker for DC Distribution Applications

  • Kim, Jin-Young;Choi, Seung-Soo;Kim, In-Dong
    • Journal of Power Electronics
    • /
    • 제17권1호
    • /
    • pp.272-281
    • /
    • 2017
  • The DC circuit breaker is essential for supplying stable DC power with the advent of DC transmission/distribution and sensitive loads. Compared with mechanical circuit breakers, which must interrupt a very large fault current due to their slow breaking capability, a solid-state circuit breaker (SSCB) can quickly break a fault current almost within 1 [ms]. Thus, it can reduce the damage of an accident a lot more than mechanical circuit breakers. However, previous DC SSCBs cannot perform the operating duty, and are not economical because many SCR are required. Therefore, this paper proposes a new DC SSCB suitable for DC grids. It has a low semiconductor conduction loss, quick reclosing and rebreaking capabilities. As a result, it can perform the operating duties of reclosing and rebreaking. The proposed DC SSCB is designed and implemented so that it is suitable for home dc distribution at a rated power of 5 [kW] and a voltage of 380 [V]. The operating characteristics are confirmed by simulation and experimental results. In addition, this paper suggests design guidelines so that it can be applied to other DC grids. It is anticipated that the proposed DC SSCB may be utilized to design and realize many DC grid systems.

제어케이블의 설치기법 개선에 의한 배전자동화용 개폐기의 EMC 성능 향상 (EMC Performance Improvement of Distribution Automation Circuit-Breaker by Modified Installing Method of Control Cable)

  • 김언석;김재철
    • 조명전기설비학회논문지
    • /
    • 제17권5호
    • /
    • pp.60-67
    • /
    • 2003
  • 본 논문에서는 개폐기의 EMC 성능 개선방안을 연구하였다. 개폐기와 제어함은 멀티 제어 케이블로 연결되었다. 또한 각 장치에는 많은 제어 케이블이 설치되었다. 이들 제어 케이블은 전자부품과 직접 연결된다. 그러므로 제어 케이블은 EMC 성능 향상에 중요한 요소이다. EMC 성능 개선방안으로 제어 케이블과 나란히 병렬접지도체 (Parallel Grinding Conductor, PGC) 설치를 제안하였다. 또한 개폐기 내에 설치된 전압 변성기의 2차 케이력은 차폐 케이블을 사용하고, 차폐의 양단을 접지하는 것을 제안하였다. 개선방안 적용 후 개폐기의 EMC성능이 향상되었음을 확인하였다.

비접지 DC 급전시스템에서의 Delta-I 지락보호계전 시스템 (Development of Delta-I ground fault Protective Relaying Scheme for DC Traction Power Supply System)

  • 정상기;권삼영;정호성;김주락
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권12호
    • /
    • pp.529-535
    • /
    • 2006
  • In DC tracking power supply system, ground faults are currently detected by the potential relay, 64P. Though 64P relay detects ground fault, it cannot identify the faulted region which causes long traffic delays and safety problem to passengers. A new ground fault protective relay scheme, ${\Delta}I$ ground fault protective relay, that can identify the faulted region is presented in this paper. In ${\Delta}I$ ground fault protective relaying scheme, ground fault is detected by 59, overvoltage relay, which operates ground switch installed between the negative bus and the ground. It preliminarily chooses the faulted feeder after comparing the current increases among feeders and trips the corresponding feeder breaker. After some time delay, it then recloses the breaker if it finds the preselected feeder is not the actual faulted feeder. Whether or not the preselected feeder is the actual faulted feeder is determined by checking the breaker trip status in the neighboring substation in the direction of the tripped breaker. If the corresponding breaker in the neighboring substation is also tripped, it finally judges the preselected feeder is actually a faulted feeder. Otherwise it recloses the tripped breaker. Its algorithms is presented and verified by EMTP simulation.

2점절 차단기 균압용 콘덴서 절연파괴 고장 메커니즘 및 성능검증 방법에 관한 연구 (Study on the Performance Verification Method and Failure Mechanism of Grading Capacitor of a Two-break Circuit-breaker)

  • 오승열;한기선;김태균
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제5권1호
    • /
    • pp.11-15
    • /
    • 2019
  • 최근 송전전압 격상으로 인해 차단기 또한 정격이 높아지고 있다. 이에 차단부의 전압 정격을 높이기 위한 방법으로 차단부 2개 이상을 직렬로 구성하는 다점절 차단기가 설치되어 운용되고 있다. 다점절 차단기에서 차단부 극간에 설치되는 균압용 콘덴서는 점절간 균등한 전압분배와 초기 과도회복전압을 저감하는 기능을 수행한다. 하지만, 세계적으로 실계통 사용에서 균압용 콘덴서는 기계적인 손상, 절연파괴에 의한 폭발 등 다수의 고장이 발생하고 있어, 이에 대한 원인 규명과 새로운 성능 검증방법에 대한 연구 필요성이 제기 되고 있다. 본 논문에서는 한전 계통에서 주로 발생한 균압용 콘덴서의 절연파괴 원인을 규명하고 이에 대한 제품 성능검증 방법을 제안하고자 한다.