• 제목/요약/키워드: Breakdown voltages

검색결과 248건 처리시간 0.03초

높은 항복 전압 특성을 가지는 이중 게이트 AlGaN/GaN 고 전자 이동도 트랜지스터 (A Dual Gate AlGaN/GaN High Electron Mobility Transistor with High Breakdown Voltages)

  • 하민우;이승철;허진철;서광석;한민구
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권1호
    • /
    • pp.18-22
    • /
    • 2005
  • We have proposed and fabricated a dual gate AlGaN/GaN high electron mobility transistor (HEMT), which exhibits the low leakage current and the high breakdown voltage for the high voltage switching applications. The additional gate between the main gate and the drain is specially designed in order to decrease the electric field concentration at the drain-side of the main gate. The leakage current of the proposed HEMT is decreased considerably and the breakdown voltage increases without sacrificing any other electric characteristics such as the transconductance and the drain current. The experimental results show that the breakdown voltage and the leakage current of proposed HEMT are 362 V and 75 nA while those of the conventional HEMT are 196 V and 428 nA, respectively.

봉형접지전극 주변에서 토중방전현상에 대한 실험적 고찰 (Experimental investigations of Breakdown Phenomena in Soils in the vicinity of Ground rod)

  • 이복희;김병근;이우철
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.279-282
    • /
    • 2005
  • Morden electronic equipments are becoming very important in information oriented society, but they are vulnerable to lightning surges. Soil resistivity in the vicinity of grounding electrodes my be affected by the current flowing from the grounding electrodes into the surrounding soil. Electrical conduction in soils depends on the grain size, compactness, and variability of the grain sizes. When a high current is injected into the soil, and the breakdown phenomenon occur. In the present work, Electrical behaviors related to discharge in soils were investigated. The breakdown voltages in soil were lower than that sparkover voltage in air. The breakdown voltage in the gravel layer is relatively low, and the breakdown was caused by the flashover through the surface of gravels

  • PDF

액체질소 중 FRP의 절연파괴 및 연면방전 특성 연구 (Breakdown and Surface Flashover Characteristics of FRP in $LN_2$)

  • 정종만;백승명;김상현
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권1호
    • /
    • pp.119-123
    • /
    • 2002
  • In this study, we discussed the characteristics of breakdown and surface flashover of FRP in L$N_2$ for applying it to spacer of a superconducting power equipment. Fiberglass reinforced plastic(FRP) has high breakdown puncture strength and has high mechanical strength. So the research of its dielectric properties have been conducted in liquid nitrogen($LN_2$). We measured breakdown voltage of FRP and distinguished four types of surface flashover along solid insulator with arrangement of electrodes and measured the surface flashover voltages of each types of electrode arrangement. The type of a electrode set at the back of the insulator showed the worst dielectric property. The property of surface flashover depending on pressure was tested.

극저온 액체 및 기체 질소의 압력에 따른 절연파괴 특성 (Effects of Pressure on the Breakdown Characteristics of Cryogenic Liquid and Gaseous Nitrogen)

  • 백승명;정종만;김상헌
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권2호
    • /
    • pp.1-4
    • /
    • 2002
  • Electrical properties of liquid nitrogen ($LN_2$) and gaseous nitrogen($GN_2$) have become of great interest again since the discovery of high temperature superconductors . It is very important from a point of superconducting apparatus protection to elucidate breakdown characteristics in $LN_2$ and $GN_2$ at atmospheric and pressurized conditions Therefore. this paper studies the effect of pressure on the breakdown characteristics in $LN_2$ and $GN_2$. Af high voltage is applied to electrode system with uniform and non-unform field in various gap length. And Breakdown voltages of $LN_2$ and $GN_2$ are investigated under AC voltage for Pressure ranging from 0 and 0.5 MPa. This research presented basis information of electrical insulation design for liquid nitrogen immersed HTS power apparatus.

GIS 스페이서의 전계해석 시뮬레이션 및 파괴전압 특성 개선 (Electric Field Analysis Simulation and Improvement of Breakdown Characteristics on the GIS Spacer)

  • 류성식;박재도;곽희로
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.540-542
    • /
    • 2000
  • This paper describes the particle-initiated breakdown characteristics of various spacers, which have a ribbed surface, in the presence of a metallic particle. The particle was attached on the surface of each spacer. The breakdown voltages were measured by changing the length and thickness of the rib. Also the electrical field analyses were performed. As a result, the breakdown voltage of the spacer with two ribs was highest, and it was varied by the length and the thickness of the rib. Especially, in case of the rib with round edge, the breakdown voltage was higher than that with rectangular edge, which complied with the result through the field analysis.

  • PDF

개선된 GIS 스페이서의 전계해석 및 파괴전압특성 (Electric Field Analyses and Breakdown Voltage Characteristics on the Improved Spacers for GIS)

  • 류성식;신동석;곽희로;김경화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1921-1923
    • /
    • 2000
  • This paper describes the particle-initiated breakdown characteristics of various spacers, which have a ribbed surface, in the presence of a metallic particle. The particles was attached on the surface of each spacer. The breakdown voltages were measured by changing the particle position on the spacer, the length and thickness of the rib. Also the electrical field analyses were performed. As a result, the breakdown voltage of the spacer with two ribs was highest, and it was varied by the length and the thickness of the rib. Especially, in case of the rib with round edge the breakdown voltage was higher than that with rectangular edge, which complied with the result through the field analysis.

  • PDF

준평등전계에서 $SF_6/CF_4$ 혼합가스의 절연 파괴 전압 및 임계전계 특성 (AC Breakdown Voltage Characteristics of $SF_6/CF_4$ and (E/P)crit in quasi-uniform Field)

  • 이병택;황청호;안정식;허창수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1455_1456
    • /
    • 2009
  • $SF_6$ is the most commonly used insulating gas in electrical systems. But In these days $SF_6$ mixtures and alternative gas has been studied because of global warming. so although many studies have been carried out about binary gas mixtures with $SF_6$, few studies were presented about breakdown characteristics of $SF_6/CF_4$ mixtures. At present study the breakdown characteristics of $SF_6/CF_4$ mixtures in quasi-uniform field was performed. This experiments were carried out under AC voltages. The rod-rod electrode was used with 5 mm gap distance. The mixture of $SF_6/CF_4$ containing 20%,50%,70% of $SF_6$ were compared with pure $SF_6$ and $CF_4$ gas and gas pressure ranged from 0.1 to 0.5 MPa. The show that the breakdown voltages of gas were linearly increased according to the pressure in quasi-uniform field. For breakdown vlotage values of $(E/P)_{crit}$ are important. Because If values of (E/P) is a little more than $(E/P)_{crit}$, electrons rapidly increase and streamer discharge gernerates. Through this experiments values of $(E/P)_{crit}$ are found to vary with the ratio of $SF_6/CF_4$ mixture according to the following relationship. $V_b=(E/P)_{crit}{\cdot}p{\cdot}d$

  • PDF

Investigation on Oil-paper Degradation Subjected to Partial Discharge Using Chaos Theory

  • Gao, Jun;Wang, Youyuan;Liao, Ruijin;Wang, Ke;Yuan, Lei;Zhang, Yiyi
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권5호
    • /
    • pp.1686-1693
    • /
    • 2014
  • In this paper, oil-paper samples composed of transformer windings were used to investigate the insulation degradation process subjected to partial discharge (PD), with artificial defects inside to simulate the PD induced insulation degradation. To determine appropriate test voltages, the breakdown time obtained through a group of accelerated electrical degradation tests under high voltages was firstly fitted by two-parameter Weibull model to acquire the average breakdown time, which was then applied to establish the inverse power law life model to choose advisable test voltages. During the electrical degradation process, PD signals were synchronously detected by an ultra-high frequency (UHF) sensor from inception to breakdown. For PD analysis, the whole degradation process was divided into ten stages, and chaos theory was introduced to analyze the variation of three chaotic parameters with the development of electrical degradation, namely the largest Lyapunov exponent, correlation dimension and Komogorov entropy of PD amplitude time series. It is shown that deterministic chaos of PD is confirmed during the oil-paper degradation process, and the obtained results provide a new effective tool for the diagnosis of degradation of oil-paper insulation subjected to PD.

전기절연유의 절연파괴에 미치는 전극간격 및 곡률반경의 영향 (The Influence of Gap Length and Tip Radius on Breakdown of Electrical Insulating Oil)

  • 강성화;채홍인;이종필;임기조
    • 한국안전학회지
    • /
    • 제19권1호
    • /
    • pp.56-59
    • /
    • 2004
  • In this paper, we investigated the influence of gap length and tip radius on breakdown of mineral based insulation oil. Applied voltages were DC and AC voltage. Electrode system was needle-plane structure. The tip radius of needle electrode was 5, 10, 20 and 25${\mu}m$, respectively. We measured breakdown voltage for each of tip radius with increasing electrode gap, 2mm to 12mm. Electric breakdown strength at tip was calculated using Mason's equation contained geometric figure. As gap length increased, breakdown strength increased linearly. But, as tip radius of needle increased, breakdown strength decreased exponentially. It can be explained by the phenomenon that electron is easily injected, as tip radius increases, and effective work function decreases. When appling DC voltage, breakdown strength was higher when polarity of needle was negative than positive. It is because of the space charge effect in accordance with the influence of liquid motion.

이중이종접합을 이용한 채널도핑된 GaAs계 전력FET의 선형성 증가 (Linearity Enhancement of Doped Channel GaAs-based Power FETs Using Double Heterostructure)

  • 김우석;김상섭;정윤하
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 하계종합학술대회 논문집(2)
    • /
    • pp.9-11
    • /
    • 2000
  • To increase the device linearities and the breakdown-voltages of FETs, Al$\sub$0.25/ Ga$\sub$0.75/AS / In$\sub$0.25/Ga$\sub$0.75/As / Partially doped channel FET(DCFET) structures are proposed. The metal- insulator -semiconductor (MIS) like structures show the high gate-drain breakdown voltage(-20 V) and high linearities. The devices showed the small ripple of the current cut-off frequency and the power cut-off frequency over the wide bias range.

  • PDF