• Title/Summary/Keyword: Breakdown voltages

Search Result 248, Processing Time 0.026 seconds

Dielectric Characteristics of Turn-ro-Turn Insulation for SFCL (초전도 한류기의 턴간 절연특성)

  • Baek, Seung-Myeong;Joung, Jong-Man;Lee, Chang-Hwa;Kim, Sang-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05a
    • /
    • pp.65-68
    • /
    • 2003
  • Interconnected power system operation has given rise to the problem of increased fault levels and leads to over stressing of all the components. Use have been made of recently developed high Tc superconductor in devising a superconducting fault current limiter (SFCL) that promises optimum performance in terms of capital cost, size, auto sensing, operational losses, response time and reliability. Recently, research about the application of the SFCL is actively progressing in Korea. To be applied for SFCL practically, the electrical insulation design of SFCL must be developed. Therefore, this paper presents the result of an investigation of the dielectric characteristics of turn-to-turn insulation for SFCL in liquid nitrogen. The dielectric characteristics of turn-to-turn insulation models of SFCL were investigated. We obtained following results. The breakdown voltages increased as the spacer thickness and length increased. And the breakdown voltages of turn-to-turn model without spacer were higher than the breakdown voltages of turn-to-turn model with spacer under impulse as well as AC voltages. The information gathered in this test series should be helpful in the design of liquid nitrogen filled SFCL.

  • PDF

Effect oh Heat Treatment on Breakdown Properties in the Joint Interface of Power Cables (전력케이블 절연접속계면의 절연파괴 특성에 미치는 열처리 효과)

  • 이창종;김진수;박강식;한상옥
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.7
    • /
    • pp.502-507
    • /
    • 1998
  • The purpose of this study is to investigate the breakdown properties in joint interface of power cables with heat treatment. The specimens have the structure of XLPE/EPDM interface like the joint of distribution power cable. The breakdown characteristics of the SLPE/EPDM joint were studied with crosslinking by=products. AC breakdown voltages were measured with heat treatment time and interfacial materials and crosslinking by-products as testing factors. This study has shown that crosslinking by-product gases play an important role at the insulation properties of cable joints by heating. The dielectric strength shows the lowest values at 4 hours heat treatment. The AC breakdown strength in the untreated sample was increased with heat treatment time.

  • PDF

ELECTRICAL BREAKDOWN INITIATION OF ANODIC FILMS DURING ANODIZING IN MOLTEN BISULPHATE MELT

  • Han, S.H.;Thompson, G.E.
    • Journal of the Korean institute of surface engineering
    • /
    • v.32 no.3
    • /
    • pp.341-343
    • /
    • 1999
  • The morphology and composition of anodic films, formed on aluminium at various current densities, in the range $1-100{\;}Am^{-2}$, in the molten bisulphate melt at different temperatures (418-498K), have been studied using transmission electron microscopy of ultramicrotomed film sections, and ion beam thinned films. The first sign of incipient breakdown revealed by transmission electron microscopy of stripped films, is always the appearance of dark regions about 1,000 nm in diameter, representing local overgrowth of the film. The breakdown mechanism is closely related to thermal effects, because temperature rises at regions representing local overgrowth in the stripped films were observed at voltages close to the breakdown voltage, likely arising through impact ionization.

  • PDF

Dielectric Characteristics of Gaseous $SF_6$ for Impulse Voltages in Presence of a Metallic Particle in GIS (가스절연개폐장치에 있어서 금속입자 존재시 임펄스전압에 대한 $SF_6$가스의 절연특성)

  • 이복희;이경옥;이창준
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.1
    • /
    • pp.22-29
    • /
    • 2000
  • This paper deals with the dielectric characteristics of $SF_6$ gas gap stressed by $\pm$1.2/44[$mutextrm{s}$] non-oscillating impulse and $\pm$0.4[$mutextrm{s}$]/1.14[MHz] oscillating impulse voltages in the presence of a needle-shape metallic particle in gas-insulated switchgear(GIS). Breakdown voltage-time (V-t) and breakdown voltage-gas pressure (V-p) characteristics were investigated and discussed. The experiments were carried out under highly inhomogeneous field geometry with a needle protrusion whose length and radius are 10[mm] and 0.5[mm], respectively. The gas pressure ranges from 0.1 to 0.5[㎫]. As a result, it was found that the electrical breakdown for both the positive and negative polarity develops with steplike pulses in leader mechanism, When subjected to the positive oscillating impulse voltage, the minimum breakdown voltages appeared in all the gas pressure ranges and the V-t curves have a pronounced upturning at short times to breakdown and give a little dependence of the gas pressure. On the other hand, in the case of the negative polarity the dependence of the V-t and V-p characteristics on the wave shape of the applied voltages is known to be appreciable.

  • PDF

Breakdown voltage characteristics of air with vertical arranged electrodes due to flame (화염에 의한 수직배치전극에서 공기의 절연파괴전압특성)

  • Kim, C.N.;Jee, S.W.;Lee, K.S.;Lee, D.I.;Kim, I.S.;Kim, L.K.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1735-1737
    • /
    • 2001
  • The occurrence of fires under transmission lines is responsible for a great number of power line outages. In this paper, the ac flashover voltages and the corona onset voltages of a needle-plane electrode gap of vertical arrangement in the presence of flame were investigated. We also observed the corona discharge current and variation of shapes in flame with increasing the applied voltages. We found that the corona onset voltages and the flashover voltages were drastically decreased with the position of flames and gap length of electrodes, and observed that the deflection or fluctuation phenomena in the shape of flames.

  • PDF

AC Breakdown Characteristics of Pure Ar, $N_2$ Gas and Ar/$N_2$ Gas Mixutres under Uniform and Non-Uniform Fields (평등 및 불평등 전계하에서 순수 Ar, $N_2$가스와 Ar/$N_2$혼합 가스의 교류절연파괴 특성)

  • 이상우;김인식;이동인;이광식;김이국
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.5
    • /
    • pp.20-27
    • /
    • 2001
  • In this paper, the AC breakdown characteristics of pure Ar and $N_2$gas with gas pressure range of 58.8~137.3[kPa] under uniform and non-uniform fields were investigated, and the measured values were compared with those in Ar/$N_2$gas mixtures with pressure varying. Summarizing the experimental results, the breakdown voltages of pure $N_2$gas, under uniform and non-uniform fields, were increased about 4.8 and 1.1 times than those of pure Ar gas, and the AC breakdown voltage increased with the pressure increasing. The breakdown voltages of Ar/$N_2$ gas mixtures were decreased with decreasing the mixture ratio of $N_2$gas. In case of Ar(85%)/$N_2$(15%) and Ar(70%)/$N_2$(30%) gas mixtures comparing to the pure Ar gas, the breakdown voltages under uniform field were increased about 1.5 and 2.1 times, and under non-uniform field were increased about 1.1 and 1.3 times at the pressure of 101.3[kPa]. Also, corona inception voltage of Ar(70%)/$N_2$(30%) gas mixtures under non-uniform field were increased about 1.5 times than those of pure Ar gas.

  • PDF

Effective Ionic Wind Generation Utilizing a Cylindrical Corona Discharge Electrode (금속관형 코로나 방전극을 적용한 효과적인 이온풍 발생)

  • Jung, Jae-Seung;Moon, Jae-Duk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.3
    • /
    • pp.599-603
    • /
    • 2010
  • A point-mesh type corona system has been well used as a ionic wind blower. However this type corona system suffers from its lower ionic wind generation, because of its lower on-set and breakdown voltages of its very sharp needle point corona electrode. This means that the point corona electrode must act both as an effective ion-generator and a very higher electric field producer in the discharge airgap in order to generate higher ionic wind velocity. In this paper, a cylinder-mesh type discharge system as a ionic wind generator is proposed and investigated. The cylindrical corona electrode can produce many ions from its sharpened edge, and the corona on-set and breakdown voltages are very higher than those of the needle point corona electrode. As a result, this type cylindrical corona electrode might generate a higher ionic wind than the needle point corona electrode.

Deposition and Electrical Properties of Silicon Nitride Thin Film MIM Capacitors for MMIC Applications (MMIC에 적용되는 MIM 커패시터의 실리콘 질화막 증착과 전기적 특성)

  • 성호근;소순진;박춘배
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.3
    • /
    • pp.283-288
    • /
    • 2004
  • We have fabricated MIM capacitors for MMIC applications, with capacitances as high as 600pF/$\textrm{mm}^2$ and excellent electrical properties of the insulator layer. Silicon nitride thin film is the desirable material for MMIC capacitor fabrication. Standard MIM capacitance in MMIC is 300pF/$\textrm{mm}^2$ with an insulator layer thickness of more than 2000$\AA$. However, capacitors with thin insulator layers have breakdown voltages as low as 20V. We have deposited insulator layers by PECVD in our MIM structure with an air bridge between the top metal and the contact pad. The PECVD process was optimized for fabricating the desired capacitors to be used in MMIC. Silicon nitride(Si$_{x}$N$_{y}$) thin films of about 1000$\AA$ thick show capacitances of about 600pF/$\textrm{mm}^2$, and breakdown voltages above 70V at 100nA.A.A.

Influence of the Conduction Properties on ZnO-Based Ceramic Varistor with $TiO_2$ Additives ($TiO_2$의 첨가가 ZnO계 세라믹 바리스타에 미치는 전기적인 영향)

  • Lee, S.S.;Jang, K.U.;Lee, J.U.
    • Proceedings of the KIEE Conference
    • /
    • 1987.11a
    • /
    • pp.234-238
    • /
    • 1987
  • In this paper, the used specimen composition was added basic additives ($Bi_2O_3\;lmol%$, $Sb_2O_3\;lmol%$, CoO 0.5 mol%, MnO 0.5mol%) to ZnO powder, and $TiO_2$ (1,2,3,4 mol%) to the above basic composition. It appears that there are four regions of conduction current depended upon the strength of the applied electric field ; Ohimic region, Poole-Frenkel region, Schottky region and Tunneling region. Increasing of $TiO_2mol%$, the breakdown voltages of ZnO ceramic varistors are decreased. The decrease of breakdown voltages was explained with the decrease of potential barrier height. Moreover, V-I characteristics with temperature dependence are decreased with increasing of $TiO_2mol%$.

  • PDF

Study of the 1,200 V-Class Floating Island IGBT (1,200 V급 Floating Island IGBT의 관한 연구)

  • Kang, Ey Goo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.9
    • /
    • pp.523-526
    • /
    • 2016
  • This paper was researched about 1,200 V level floating island IGBT (insulated gate bipolar transistor). Presently, 1,200 V level IGBT is used in Inverter for distributed power generation. We analyzed and compared electrical charateristics of the proposed floating island IGBT and conventional IGBT. For analyzing and comparison, we used T-CAD tool and simulated the electrical charateristics of the devices. And we extracted optimal design and process parameter of the devices. As a result of experiments, we obtained 1,456 V and 1,459 V of breakdown voltages, respectively. And we obatined 4.06 V and 4.09 V of threshold voltages, respectively. On the other hand, on-state voltage drop of floating island IGBT was 3.75 V. but on-state vlotage drop of the conventional IGBT was 4.65 V. Therefore, we almost knew that the proposed floating island IGBT was superior than the conventional IGBT in terms of power dissipation.