• Title/Summary/Keyword: Break-down

검색결과 504건 처리시간 0.027초

액체유도체의 절연특성에 미치는 초음파의 영향 (Ultransonic Effect on the Break-Down Characteristics of Liquid Dielectrics)

  • 전춘생;김홍근;홍봉식
    • 전기의세계
    • /
    • 제26권4호
    • /
    • pp.61-67
    • /
    • 1977
  • This paper treats the Ultrasonic effects on the break down characteristics of Liquid Dielectric Material 1) Relative Dielectric constant, Es of Liquid Dielectric Material at a constant temperature decreases in proportion to the irradiated time of Ultrasonic radiation and its intensity, and reaches to a certain saturated value. The saturated value varies with the intensity of Ultrasonic radiation. 2) Power factor of Liquid Dielectric Material at a constant temperature increases in proportion tothe irradiated time of Ultrasonic radiation and its intensity, and reaches to a certain saturated value. The saturated value varies with the intensity of Ultrasonic radiation. 3) Relative resistance of Liquid Dielectric Material at a constant temperature decrease with the irradiated time of Ultrasonic radiation, but the effect of its intensity is very irregular. 4) Break-down strength of Liquid Dielectric Material, at a constant temperature decreases with the irradiated time of Ultrasonic radiation and its intensity, and then reaches to a saturated value.

  • PDF

동력경운기(動力耕耘機) 이용실태(利用實態) 조사분석(調査分析)(II) -고장(故障) 및 수리(修理)에 관(關)하여- (A Survey on the Break-down and Repair of the Power Tillers in Korea)

  • 홍종호;이채식
    • Journal of Biosystems Engineering
    • /
    • 제6권1호
    • /
    • pp.28-38
    • /
    • 1981
  • 동력경운기(動力耕耘機)의 효율적(效率的)인 이용(利用)과 고장(故障)으로 인(因)한 문제점(問題點)과 그에 따른 대책(對策)을 강구(講究)하기 위(爲)한 기초자료(基礎資料)를 제시(提示)코저 전국(全國) 8개도 278농가(農家)를 대상(對象)으로 동력경운기(動力耕耘機)의 각종(各種) 고장(故障) 및 수리실태(修理實態)를 조사분석(調査分析)한 결과(結果)는 다음과 같다. 가. 고장빈도(故障頻度) 동력경운기(動力耕耘機)의 대당(臺當) 년간(年間) 고장발생(故障發生) 빈도(頻度)는 9.05회(回)이었으며 평균(平均) 39.1시간(時間) 작업(作業)에 1회(回)의 고장(故障)이 발생(發生)되었다. 고장빈도(故障頻度)가 가장 높았던 곳은 점화연료공급계통(點火燃料供給系統)으로서 2.02회(回)로 전체고장(全體故障)의 22.3%를 차지하였고, 그 다음이 부속작업기(附屬作業機) 시린더계통(系統), 주행장치등(走行裝置等)의 순서(順序)로 나타났다. (2) 동력경운기(動力耕耘機) 사용년수별(使用年水別) 고장(故障) 발생빈도(發生頻度)는 구입후(購入後) 6년(年) 이하(以下) 경과(經過)된 기계(機械)에서 37.7시간(時間) 사용(使用)에 1회(回)의 고장(故障)이 발생(發生)된 것으로 나타나 가장 높았고 그 다음이 구입후(購入後) 2년(年) 미만(未滿)된 기계(機械)로서 38.6시간(時間) 작업(作業)에 1회(回)이 고장(故障)이 발생(發生)되었다. (3) 동력경운기(動力耕耘機) 기종별(機種別) 고장(故障) 발생빈도(發生頻度)는 석유(石油)엔진이 36.3시간(時間) 작업(作業)에 1회(回)의 고장(故障)이 발생(發生)되어 디젤엔진의 42.8시간(時間)보다 높았고 마력별(馬力別)로는 석유(石油)엔진의 경우(境遇) 8마력(馬力)이 10마력(馬力)보다 고장(故障) 발생빈도(發生頻度)가 높게 나타났다. (4) 동력경운기(動力耕耘機) 월별(月別) 고장(故障) 발생빈도(發生頻度)는 10월(月)에 가장 낮아 51.5시간(時間) 작업(作業)에 1회(回)의 고장(故障)이 발생(發生)되었고 그 다음이 6월로 49.7시간(時間) 작업(作業)에 1회(回)의 고장(故障)이 발생(發生)된 것으로 나타나 작업시간(作業時間)이 많았을 때 고장(故障) 발생빈도(發生頻度)는 상대적(相對的)으로 적었던 것으로 나타났다. 나. 수리장소(修理場所) (1) 동력경운기(動力耕耘機) 고장시(故障時)의 수리장소(修理場所)는 자가수리(自家修理)가 평균(平均) 45.3%이었고 공장수리(工場修理)가 54.7%로 나타나 공장수리(工場修理)가 자가수리(自家修理)보다 많았다. (2) 동력경운기(動力耕耘機) 사용년수별(使用年數別) 수리장소(修理場所)는 구입후(購入後) 경과년수(經過年數)가 길어질수록 공장수리(工場修理)보다 자가수리(自家修理)가 많아지는 것으로 나타났다. (3) 동력경운기(動力耕耘機) 자가수리율(自家修理率)은 디젤엔진이 석유(石油)엔진보다 높았으며 석유(石油)엔진에서는 10마력(魔力)이 디젤엔진에서는 8마력(魔力)이 높았다. (4) 고장부위별(故障部位別) 자가수리(自家修理) 비율(比率)은 조향장치(操向裝置)가 가장 높아 66.7%였으며 그 다음이 점화연료계통(點火燃料系統)인 것으로 나타났고 자가수리비율(自家修理比率)이 가장 낮는 곳은 부속작업기(附屬作業機)로서 26.5%에 불과(不過)하였다. 다. 고장원인(故障原因) (1) 동력경운기(動力耕耘機) 고장원인(故障原因)은 기계(機械)의 노후(老朽)에 의(依)한 고장(故障)이 년간(年間) 대당(臺當) 5.18회(回)로 전체(全體)의 57.2%를 차지하여 가장 많았고 정비불량(整備不良)과 과부하(過負荷)로 인(因)한 고장(故障)이 전체(傳遞)의 37.7%이었다. (2) 동력경운기(動力耕耘機) 구입후(購入後) 2년(年) 미만(未滿)의 기종(機種)에서는 정비불량(整備不良)으로 인(因)한 고장(故障)이 많았던 반면(反面) 노후(老朽)로 인(因)한 고장(故障)이 적었다. (3) 동력경운기(動力耕耘機) 고장원인(故障原因)은 기종별(機種別) 마력별(馬力別) 공(共)히 노후(老朽)로 인(因)한 고장(故障)과 과부하(過負荷)로 인(因)한 고장(故障)이 대부분(大部分)이었으며 특히 석유(石油) 5마력(馬力)엔진에서는 과부하(過負荷)로 인(因)한 고장(故障)이 월등히 높았다. (4) 동력경운기(動力耕耘機) 부위별(部位別) 고장원인(故障原因)은 시린더 계통(系統)과 주행장소(走行場所)의 고장(故障)에서는 주(主)로 노후(老朽)에 의(衣)한 원인(原因)이 많았던 반면(反面) 점화연료계통(點火燃料系統)의 고장(故障)에서는 정비불량(整備不良)으로 인한 고장(故障)이 많았다. 라. 수리비율(修理(比率) (1) 동력경운기(動力耕耘機) 년간(年間) 대당(臺當) 수리비(修理費)는 34,509원이었고 동력경운기(動力耕耘機) 1시간(時間) 수업당(修業當) 평균(平均) 수리비(修理費)는 97원이었다. (2) 동력경운기(動力耕耘機) 기종별(機種別) 수리비(修理費)는 석유(石油)엔진이 40,697원으로 디젤엔진의 28,322원보다 훨씬 많았다. (3) 동력경운기(動力耕耘機) 기종별(機種別) 1시간(時間) 수업당(修業當) 평균(平均) 수리비(修理費)는 석유(石油)엔진이 108원으로 디젤엔진의 86원보다 많았으며 마력별(馬力別)로는 차이(差異)가 없었다. (4) 동력경운기(動力耕耘機) 고장부위별(故障部位別) 년간(年間) 수리비(修理費)는 시린더 계통(系統)이 13,036원으로 가장 많았으며 조향장치(操向裝置)가 362원으로 가장 적었다. (5) 동력경운기(動力耕耘機) 1회(回) 수리시(修理時)의 평균(平均) 수리비(修理費)는 3,713원이었으며 시린더계통(系統)이 10,598원으로 가장 많았고 조향장치(操向裝置)가 1,006원으로 가장 적었다. 마. 자가수리소요시간(自家修理所要時間) 및 고장(故障)으로 인(因)한 불가동시간(不稼動時間) (1) 동력경운기(動力耕耘機) 년간(年間) 대당(臺當) 자가수리(自家修理) 소요시간(所要時間)은 8.36시간(時間)이었고 고장(故障)때문에 작업(作業)하지 못한 시간(時間)은 년간(年間) 대당(臺當) 93.5시간(時間)이었다. (2) 동력경운기(動力耕耘機) 사용년수별(使用年水別) 자가수리시(自家修理時)의 1회수리당(回修理當) 소요시간(所要時間)은 6년이상(年以上) 경과(經過)된 기계(機械)에서 21.3시간(時間)으로 가장 높았고 고장(故障) 때문에 사용(使用)하지 못한 시간(時間)은 2년(年) 미만(未滿)된 기계(機械)에서 년간(年間) 대당(臺當) 127.13시간(時間)으로 나타나 가장 높았다. (3) 동력경운기(動力耕耘機) 기종별(機種別) 자가수리시(自家修理時)의 1회(回) 수리당(修理當) 소요시간(所要時間)은 디젤엔진이 10.66시간(時間)으로 석유(石油)엔진의 6.48시간(時間)보다 많았고 고장(故障)으로 인(因)하여 가동(稼動)하지 못한 시간(時間)은 석유(石油)엔진이 년간(年間) 대당(臺當) 99.4시간(時間)으로 디젤엔진의 88.67시간(時間)보다 많았다. (4) 동력경운기(動力耕耘機) 마력별(馬力別) 자가수리시(自家修理時)의 1회수리당(回修理當) 소요시간(所要時間)은 석유(石油)엔진 디젤엔진 공(共)히 8마력(馬力)이 가장 적어 석유(石油)엔진 3.78시간(時間)이었고 디젤엔진은 8.25시간(時間)이었다. (5) 동력경운기(動力耕耘機) 고장부위별(故障部位別) 자가수리시(自家修理時)의 1회수리당(回修理當) 소요시간(所要時間)은 시린더 계통(系統)이 가장 많은 32.02시간(時間)이었고 고장(故障)으로 인(因)하여 가동(稼動)하지 못한 시간(時間)은 시린더 계통(系統)이 가장 많아 년간(年間) 대당(臺當) 37.30시간(時間)이었다.

  • PDF

비상 제동기능을 지닌 전자력 브레이크 시스템(MABS)에 대한 제안 및 동작특성해석 (Dynamic characteristics analysis of the magnetic actuator brake system (MASS) for emergency a car)

  • 강종호;김태용;최상민;정현교
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.68-70
    • /
    • 2006
  • This paper formulates the principle of the magnetic actuator break system (MASS) for emergency situation driving a car. When the exciting break system of a car is broken, MASS will be able to stop the car by the electric system. MASS controls the rotating wheel to slow down gradually while holding and laying the wheel down several ten times per second. We present the magnetic field and dynamic behavior analyses for the magnetic actuator break system using finite element method (FEM) associated with parameter, for calculating the displacement of the moving parts and the supplying current.

  • PDF

웹을 기반으로 한 실내건축공사의 원가관리 시스템 개발에 관한 연구 (A study on the development of a web-based cost management system of building interior projects)

  • 송영규
    • 한국실내디자인학회논문집
    • /
    • 제13권3호
    • /
    • pp.197-204
    • /
    • 2004
  • This study aims at the development of a cost management system in building interior projects. Renovation and remodeling is activated and expanded much more being compared with new building construction at present. After Interior project proceeding must get out of simple estimate and assumption, then its be needed a formal work process and computerized cost management. Proceeding a building interior project management was proceed in the office and the field. Cost break down, especially, depend on the field manger and used fiend managing money because its not checked by cost manager in office manger. For this study, cost factors are defined in terms of cost break-down interior works which consist of materials and labors. A data model for cost factors was developed, and a relational database is used to realize cost data management based upon this data model. Data input and output are achieved by internet from both of wired PC and mobile phone. This system can timely display a number of needed reports for cost management that identifies cash flow and predicts budget for cost break-down works in interior projects.

16 V 급 NMOSFET 소자의 낮은 게이트 전압 영역에서 출력저항 개선에 대한 연구 (Design and Analysis of 16 V N-TYPE MOSFET Transistor for the Output Resistance Improvement at Low Gate Bias)

  • 김영목;이한신;성만영
    • 한국전기전자재료학회논문지
    • /
    • 제21권2호
    • /
    • pp.104-110
    • /
    • 2008
  • In this paper we proposed a new source-drain structure for N-type MOSFET which can suppress the output resistance reduction of a device in saturation region due to soft break down leakage at high drain voltage when the gate is biased around relatively low voltage. When a device is generally used as a switch at high gate bias the current level is very important for the operation. but in electronic circuit like an amplifier we should mainly consider the output resistance for the stable voltage gain and the operation at low gate bias. Hence with T-SUPREM simulator we designed devices that operate at low gate bias and high gate bias respectively without a extra photo mask layer and ion-implantation steps. As a result the soft break down leakage due to impact ionization is reduced remarkably and the output resistance increases about 3 times in the device that operates at the low gate bias. Also it is expected that electronic circuit designers can easily design a circuit using the offered N-type MOSFET device with the better output resistance.

고온초전도선의 단선전류 특성분석 (Characteristics of Breakdown Current of HTS Tape)

  • 김재호;심기덕;조전욱;김해준;성기철;김해종;곽동순;배준한;박승엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.200-202
    • /
    • 2004
  • Characteristics of the break down current of HTS tape with different insulator are described. The various insulators are utilized for enduring the high voltage in superconducting power devices. The break down current of HTS tape largely depends on insulators wound round HTS tape. In this research, The break down currents of Bi-2223 tape, which is widely used for superconducting power devices are tested and discussed. It is expected that results from this study can be utilized as basic data in designing superconducting power devices.

  • PDF

Comparison of three small-break loss-of-coolant accident tests with different break locations using the system-integrated modular advanced reactor-integral test loop facility to estimate the safety of the smart design

  • Bae, Hwang;Kim, Dong Eok;Ryu, Sung-Uk;Yi, Sung-Jae;Park, Hyun-Sik
    • Nuclear Engineering and Technology
    • /
    • 제49권5호
    • /
    • pp.968-978
    • /
    • 2017
  • Three small-break loss-of-coolant accident (SBLOCA) tests with safety injection pumps were carried out using the integral-effect test loop for SMART (System-integrated Modular Advanced ReacTor), i.e., the SMART-ITL facility. The types of break are a safety injection system line break, shutdown cooling system line break, and pressurizer safety valve line break. The thermal-hydraulic phenomena show a traditional behavior to decrease the temperature and pressure whereas the local phenomena are slightly different during the early stage of the transient after a break simulation. A safety injection using a high-pressure pump effectively cools down and recovers the inventory of a reactor coolant system. The global trends show reproducible results for an SBLOCA scenario with three different break locations. It was confirmed that the safety injection system is robustly safe enough to protect from a core uncovery.

벼품종의 재배지역에 따른 미질특성변이 I. 미질특성의 지역변이 (Variation of Grain Quality of Rice Varieties Grown at Different Locations I. Locational Variation of Quality-related Characteristics of Rice Grain)

  • 김광호;주현규
    • 한국작물학회지
    • /
    • 제35권1호
    • /
    • pp.34-43
    • /
    • 1990
  • 미질에 관련된 주요 형질들의 지역변이정도를 비교하기 위하여 우리나라에서 재배되고 있는 6품종이 벼를 '87-'88년의 2년간에 걸쳐 품종별로 8-20개 지역에서 수집하여 이들 각각의 도정률, 쌀의 외관, 아밀로스함량 및 알칼리 붕괴도, 관능검사에 의한 식미평가, 레오메타를 이용한 밥알의 조직감 그리고 아밀로그라프에 의한 쌀가루의 호화 및 점도특성을 조사하였다. 1. 조사한 미질관련형질 중 정현비율, 현백비율, 백미천립중 및 쌀의 아밀로스합량은 지역변이가 작았으나 완전백미비율, 쌀의 알칼리붕괴도, 쌀가루의 gel consistency, 심복백미비율, 심복백정도와 수명도의 지역변이는 상대적으로 컸으며 특히 심복백미비율의 변이정도는 공시한 6품종에서 모두 컸다. 2. 품종별로 '87년과 '88년 계속해서 심복백미비율이 상대적으로 낮은 쌀을 생산한 지역은 추청벼의 경우 충주, 음성, 안성 및 영덕이었고 동진벼는 안성, 상풍벼는 상주(화서)와 안성, 삼강벼는 춘천, 연천 및 상주(화서), 그리고 용문벼는 상주(화서)와 연천이었다. 3. 관능검사법으로 조사한 식미형질들은 품종, 연도 및 조사항목에 따라서 지역변이정도가 다양하게 변하였으나 레오메타로 조사한 밥알의 조직감 중 식미지수 및 점착성의 지역변이는 매우 컸고 응집성 및 탄력성은 낮은 변이계수를 보였다. 4. 품종별로 식미지수가 2년 연속 평균치보다 높았던 쌀을 생산한 지역은 추청벼는 해당지역이 없고, 동진벼는 안성, 상풍벼는 이천과 영덕, 삼강벼는 여주, 그리고 용문벼는 안성이었고, 점성/경도 비율이 높았던 곳은 추청벼가 김포, 동진벼는 안성, 삼강벼는 이천과 이리, 그리고 용문벼는 춘천이었다. 5. 쌀가루의 아밀로그람특성 중에서는 set back, break down 및 최고점도의 지역변이가 컸다. Set back이 특별히 낮고 break down이 평균치보다 훨씬 높은 쌀을 생산한 지역을 보면 추청벼는 서산과 안성, 동진벼는 안성, 서산 및 화순, 삼강벼는 안성, 서산, 화순 및 계화도 그리고 용문벼는 안성과 충주였다.

  • PDF

비수도권(非首都圈) 지역(地域)에서의 전신용(全身用) X선(線) CT의 이용(利用) (Utilization of Body Computed Tomography Scanners in Non-Metropolitan Area)

  • 박영선
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제8권2호
    • /
    • pp.29-45
    • /
    • 1985
  • Computed Tomography Scanner (CT) is highly expensive in operation as well as purchasing. That reason may cause not only to increase the burden of patients but also to waste the capital resources leading to financial difficulties. However the numbers of CT installed throughout the country is increasing, because of efficiency in medical care, patient's concern, competitions among the hospitals within the same area. In the non-Metropolitan area the scanners were expected to be less utilized and less profitable. Nine hospitals equipped with the CT were studied on the utilization of that equipment during the period from November 1984 to February 1985 in non-Metropolitan area and break-even point in one hospital was analyzed for estimating profitabilities. The results were as follows ; 1. Among those nine hospitals, four hospitals had less than 400 beds, which is one of the restrictive minimum standards on the installation of Whole-body Computed Tomography Scanner. 2. The operating time during the normal operation period was longer than those of any other studies, but the accumulated down time was also longer than those of any other studies. The average number of scanning per week for each CT was 45, while the estimated number of for the break-even point was 56.7 cases. 3. When the downtime was excluded in calculating the average operation would be much closer to the cases for the break-even point. Therefore the break-down of the equipment was to be a main cause of the low profitability. 4. The average scanning rate for head area was 33.6%, however three of the nine hospitals showed about 20%. 5. If scanning ratio for the body parts excepting head was increased, the number of scanning for the break-even point would be diminished. 6. The small size hospital especially located near the Metropolitan area showed largest loss in the CT operation. In purchasing the highly expensive equipments in hospitals, demand should be taken into account and planning is recommended.

  • PDF

RCD success criteria estimation based on allowable coping time

  • Ham, Jaehyun;Cho, Jaehyun;Kim, Jaewhan;Kang, Hyun Gook
    • Nuclear Engineering and Technology
    • /
    • 제51권2호
    • /
    • pp.402-409
    • /
    • 2019
  • When a loss of coolant accident (LOCA) occurs in a nuclear power plant, accident scenarios which can prevent core damage are defined based on break size. Current probabilistic safety assessment evaluates that core damage can be prevented under small-break LOCA (SBLOCA) and steam generator tube rupture (SGTR) with rapid cool down (RCD) strategy when all safety injection systems are unavailable. However, previous research has pointed out a limitation of RCD in terms of initiation time. Therefore, RCD success criteria estimation based on allowable coping time under a SBLOCA or SGTR when all safety injection systems are unavailable was performed based on time-line and thermal-hydraulic analyses. The time line analysis assumed a single emergency operating procedure flow, and the thermal hydraulic analysis utilized MARS-KS code with variables of break size, cooling rate, and operator allowable time. Results show while RCD is possible under SGTR, it is impossible under SBLOCA at the APR1400's current cooling rate limitation of 55 K/hr. A success criteria map for RCD under SBLOCA is suggested without cooling rate limitation.