• Title/Summary/Keyword: Branch-line

Search Result 387, Processing Time 0.025 seconds

Fast and Efficient FDTD Analysis for Microstrip Structures (마이크로스트립 구조에 대한 빠르고 효율적인 FDTD 해석)

  • 우종우;윤현보
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.8
    • /
    • pp.1297-1304
    • /
    • 2000
  • The full wave method requires a great number of computer memory and lasting long CPU time for the calculation of the discontinuity problems in microstrip structures. While the computation only for the transverse field components at those structures causes the both of time and memory reduction. For the case of the calculating only transverse components for the most of microstrip structures such as low-pass filter, branch coupler and patch antenna the computer memory and running time can be reduced to about 50% and 33%, comparing to the full wave computation. Consequently, the proposed method than that of TEM-mode has an advantages of higher speed and less memory than that of conventional FDTD analysis.

  • PDF

Combined Design of PSS and STATCOM Controllers for Power System Stability Enhancement

  • Rohani, Ahmad;Tirtashi, M. Reza Safari;Noroozian, Reza
    • Journal of Power Electronics
    • /
    • v.11 no.5
    • /
    • pp.734-742
    • /
    • 2011
  • In this paper a robust method is presented for the combined design of STATCOM and Power System Stabilizer (PSS) controllers in order to enhance the damping of the low frequency oscillations in power systems. The combined design problems among PSS and STATCOM internal ac and dc voltage controllers has been taken into consideration. The equations that describe the proposed system have been linearized and a Fuzzy Logic Controller (FLC) has been designed for the PSS. Then, the Particle Swarm Optimization technique (PSO) which has a strong ability to find the most optimistic results is employed to search for the optimal STATCOM controller parameters. The proposed controllers are evaluated on a single machine infinite bus power system with the STATCOM installed in the midpoint of the transmission line. The results analysis reveals that the combined design has an excellent capability in damping a power system's low frequency oscillations, and that it greatly enhances the dynamic stability of power systems. Moreover, a system performance analysis under different operating conditions and some performance indices studies show the effectiveness of the combined design.

Research on utilizing global R&D funding database to plan convergence R&D project: Exploring convergence R&D related to the coastal inundation (융합 R&D 기획을 위한 글로벌 연구개발 과제 정보 체계 활용: 해안 침수 관련 융합 R&D 탐색을 중심으로)

  • Heo, Yoseob;Shim, We;Seo, Seongho;Kang, Hyunmu;Kang, Jongseok
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.5
    • /
    • pp.475-481
    • /
    • 2019
  • The paradigm of convergence R&D is shifting from the convergence of technologies to the convergence of solutions to solve the complex problems of scientific and social development. On the other hand, it is prevalent that there is a lack of convergence in our research field. Although Korea has invested heavily in fusion research and development, Korea has mainly focused on the application and development of technology, so failed to plan convergence R&D in line with the new paradigm. Therefore, in this study, we searched for convergence R&D area that is being done to solve social problems, and tried to make use of data-driven objective methods. For this purpose, we used the investment information of global R&D projects that had no retrospective properties and derived the convergence R&D area related to coastal flooding.

The Regional Anatomy of Perforating artery and Pedicle for the Anterolateral Thigh Free Flap in the Korean (한국사람의 앞가쪽넙다리유리피판술에서의 관통동맥과 피판줄기에 대한 국소 해부)

  • Song, Hyun Suk;Park, Myong Chul
    • Archives of Plastic Surgery
    • /
    • v.35 no.1
    • /
    • pp.20-27
    • /
    • 2008
  • Purpose: The anterolateral thigh flap has many advantages over other conventional free flaps. But the anterolateral thigh flap has yet to enter widespread use because perforating arteries exhibit a wide range of anatomic variations and are difficult to dissect when small. The aim of this study is to identify the vascular variability of perforating arteries and pedicle in the anterolateral thigh free flap. Methods: We studied 12 cadavers and dissected 23 thighs. An anterolateral thigh flap ($12{\times}12cm$) was designed and centered at the midpoint of the line drawn from anterior superior iliac spine to the superolateral border of the patella. After we identifed the perforating arteries we dissected up to their origin from lateral circumflex femoral artery along descending branch of lateral circumflex femoral artery. We then investigated the number and the position of perforating arteries, length and diameter of vascular pedicle and pattern of lateral circumflex femoral arterial system. Results: On average $2.3{\pm}1.1$ perforating arteries per thigh were identified. The musculocutaneous perforators were 63.1%. In those perforators five perforators were arose from transverse branch of lateral circumflex femoral artery and two were arose from rectus femoral artery. Most of the perforators were near the intermuscular septum between rectus femoris muscle and vastus lateralis muscle. The length and diameter of pedicle were $11.9{\pm}3.5cm$ and $3.1{\pm}0.8mm$ on average. Conclusion: This study will be helpful for the success in anterolateral thigh free flap.

A study on Protective Coordination of MCA for Performing of the Pad Mounted Transformer's inside Protective Device (지상변압기의 내부 보호장비 작동을 위한 MCA 보호협조에 대한 연구)

  • Hyun, Seung-Yoon;Kim, Chang-Hwan
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.1
    • /
    • pp.5-7
    • /
    • 2022
  • KEPCO's plan is undergoing a trial operation to replace the open-loop section with ring main units configuration where underground distribution lines are installed, by linking the multi-way circuit breakers auto (MCA) on the power side of each pad-mounted transformer. However, ring main units application mentioned above may cause the ripple effects, when implementing the configuration without a study of protection coordination. Because ring main units with classical pre-set protection devices contribution in fault condition didn't consider yet. For the reliable ring main units operation, it is necessary to resolve several protection issues such as the protection coordination with substation side, prevention of the transformer inrush current. These issues can radically deteriorate the distribution system reliability Hence, it is essential to design proper protection coordination to reduce these types of problems. This paper presents a scheme of ring main units' configuration and MCA's settings of time-current curves to preserve the performance of protection coordination among the switchgears considering constraints, e.g. prevention of the ripple effects (on the branch section when a transformer failure occurs and the mainline when a branch line failure occurs). It was confirmed that the propagation of the failure for each interrupter segment could be minimized by applying the proposed TCC and the interrupter settings for the MCAs (branch, transformer). Further, it was verified that the undetected area of the distribution automation system (DAS) could be supplemented by having the MCA configurated ring main units operate first, instead of the internal protection equipment in the transformer such as the fuse, STP when a transformer failure occurs.

Near-Infrared Photopolarimetry of Large Main Belt Asteroid - (4) Vesta

  • Bach, Yoonsoo P.;Ishiguro, Masateru;Takahashi, Jun;Naito, Hiroyuki;Kwon, Jungmi;Kuroda, Daisuke
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.1
    • /
    • pp.45.1-45.1
    • /
    • 2021
  • The polarization degree as a function of phase angle (the Sun-target-observer's angle), so-called the polarimetric phase curves (PPC), have provided priceless information on asteroids' albedos since B. Lyot (1929). Succeeding experimental works in 1970s have confirmed the Umow law: There is a universal and strong correlation between the albedo and the PPC slope (slope of the tangential line at the zero of the PPC at phase angle ~ 20 degrees). Experiments in 1990s (ref [1]), on the other hand, have demonstrated that the negative branch of PPC is dependent on the size parameter (X ~ π * particle-size / wavelength), especially when X <~5. The change in particle size changed the minimum polarization degree, location of the minimum, and the width of the negative branch (called the inversion angle). From polarimetry[2] and spectroscopy[3], large asteroids are expected to be covered with fine (<~ 10 ㎛ size) particles due to the gravity. The size parameters are X ~ 30 at the optical wavelength (λ ~ 0.5 ㎛) and X ~ 10 in near-infrared (J, H, Ks bands; λ ~ 1.2-2.2 ㎛), if the representative particle size of 5 ㎛ is considered. Accordingly, the near-infrared polarimetry has a great potential to validate the idea in ref[1]. We conducted near-infrared photopolarimetry of the large asteroid (4) Vesta using the Nishiharima Infrared Camera (NIC) at Nishi-Harima Astronomical Observatory (NHAO). NIC allows simultaneous polarimetric measurements in J, H, and Ks bands, and thus the change of PPC is obtained for three different size parameters. As a result, we found a signature of the change in the negative branch in the PPC of asteroid (4) Vesta. We will introduce our observation and the results and give an interpretation of the regolith on Vesta.

  • PDF

A Development of Optimum Operation Models for Express-Rail Systems (급행열차 도입을 통한 최적운행방안 수립에 관한 연구 - 수도권 광역 도시철도를 중심으로 -)

  • Park, Jeong-Soo;Lee, Hoon-Hee;Won, Jai-Mu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.4D
    • /
    • pp.679-686
    • /
    • 2006
  • Recently, the city railway in the Seoul Metropolitan Area (SMA) has offered a low quality of service as a passage time, because it was operated slowly. So, the people who live in modern society are not satisfied about passage time, therefore, this study tried to make that the subway in the SMA becomes a more functional and effective wide-area-transportation-network through an express train introduction's method which examined cases from abroad and current system. and then presented how express train could be applied to current system. In a case study, We used the An-San Line and Su-In Line as a examples and developed a schedule which can minimize the delaying time of subway by using Branch & Bound Algorithm. The train operational plan was loaded to consider a railroad siding, Obtained site, and the dispatch interval(three to ten minutes) for the express and local lines and finally, We presented an alternative operational plan which made by those factors.

Line Planning Optimization Model for Intercity Railway (지역간 철도의 노선계획 최적화 모형)

  • Oh, Dongkyu;Kho, Seung-Young;Kang, Seungmo
    • Journal of Korean Society of Transportation
    • /
    • v.31 no.2
    • /
    • pp.80-89
    • /
    • 2013
  • The purpose of this research is to optimize the line planning of the intercity passenger railway. In this study, the line planning problem has been formulated into a mixed integer programming by minimizing both user costs (passenger's total travel time) and operator costs (operation, maintenance and vehicle costs) with multiple train types. As a solution algorithm, the branch-and-bound method is used to solve this problem. The change of travel demand, train speed and the number of schedules have been tested through sensitivity analysis. The optimal stop-schedules and frequency as well as system split with respect to each train type have been found in the case study of Kyoung-bu railway line in Korea. The model and results of this research are useful to make a decision for railway operation strategy, to analyze the efficiency of new railway systems and to evaluate the social costs of users and operators.

Dual-Band Unequal Power Divider based on CRLH Transmission Line (CRLH 전송선로를 기반으로 한 이중대역 비대칭 전력 분배기)

  • Yoo, Jae-Hyun;Kim, Young;Yoon, Young-Chul
    • Journal of Advanced Navigation Technology
    • /
    • v.14 no.6
    • /
    • pp.909-915
    • /
    • 2010
  • In this paper, the unequal power divider based on CRLH (Composite Right/Left-Handed) transmission line with dual-band characteristic is proposed. They consist of dual-band branch line hybrid coupler, the connection between input and isolation port of hybrid coupler and ${\lambda}/4$ impedance transformer. When the transmission line between input and isolation port of hybrid coupler is asymmetrical connected, the divider is obtained the output results of the equal phase and unequal power dividing ratio. The simulation results of the divider represent the power ratio of 0 dB ~ 20 dB. To validate a function of divider, the hybrid coupler and transformer with 880 MHz and 1850 MHz is implemented. As a result, the proposed unequal divider obtains the power ratio of 3.2 dB ~ 8.8 dB at 880 MHz and 2.5 dB ~ 14.0 dB at 1850 MHz.

Effect of the Planting Density and Pinching on Yield of Petal and Grain in Safflower (Carthamus tinctorius L.) (홍화 밀식 및 적심이 꽃잎과 종실 수량에 미치는 영향)

  • Kim, Se-Jong;Park, Jun-Hong;Kim, Jae-Chul;Park, So-Deuk
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.51 no.spc1
    • /
    • pp.255-258
    • /
    • 2006
  • This study was carried out to find the effect of the pinching and planting density on yield of petal and grain in safflower (Caythamus tinctorius L.). The planting density was high effective branch number per $m^2$ compared with pinching, and effective flower bud was most in $270ea/m^2$ in three line planting density, but in case of pinching was few at $186{\sim}223ea/m^2$ Grain yield was increased with 231 kg/10a at double line planting density compared with in 220 kg/10a of control. Petal yield of double line and three line planting density was 25.4 kg/10a and 26.9 kg/10a, it was increased 15, 22% compared with 22.0 kg/10a of control, respectively.