• 제목/요약/키워드: Branch-line

검색결과 387건 처리시간 0.024초

최소절대값 상태추정에 의한 전력계통 선로 토폴로지 에러의 추정 (Estimation of Branch Topology Errors in Power Networks by WLAN State Estimation)

  • 김홍래;송경빈
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권6호
    • /
    • pp.259-265
    • /
    • 2000
  • The purpose of this paper is to detect and identify topological errors in order to maintain a reliable database for the state estimator. In this paper, a two stage estimation procedure is used to identify the topology errors. At the first stage, the WSAV state estimator which has characteristics to remove bad data during the estimation procedure is run for finding out the suspected branches at which topology errors take place. The resulting residuals are normalized and the measurements with significant normalized residuals are selected. A set of suspected branches is formed based on these selected measurements; if the selected measurement is a line flow, the corresponding branch is suspected; if it is an injection, then all the branches connecting the injection bus to its immediate neighbors are suspected. A new WLAV state estimator adding the branch flow errors in the state vector is developed to identify the branch topology errors. Sample cases of single topology error and topology error with a measurement error are applied to IEEE 14 bus test system.

  • PDF

장어 통발어장의 어획상태 비교 (Comparisom of Fishing Efficiency of Eel Traps)

  • 서영태;김광홍
    • 수산해양기술연구
    • /
    • 제13권2호
    • /
    • pp.15-20
    • /
    • 1977
  • Fishing efficiency of conventional bamboo traps and other traps for eel Conger myriaster, was investigated. The results are as follows: ). The best fishing efficiency was observed when the trap is inclined to the sea bottom with 20 ~ 30 degrees. 2. Plastic traps were better compared with bamboo traps in rigidity and fishing efficiency. 3. Using clips in attaching branch line to main line, the operating time was saved somewhat considerably.

  • PDF

Elucidation of Central Line Refocusing in Quadrupolar Echo Formation

  • Han, Duk-Young
    • 한국자기공명학회논문지
    • /
    • 제3권1호
    • /
    • pp.27-35
    • /
    • 1999
  • Quadrupolar interaction is a strong line broadening agent for nuclei of half-integer spin except the central line. The two-pulse quadrupolar echo technique is widely used, which refocuses the quadrupolar broadening. Echo formation is due to the cancellation of quadrupolar broadening effect by the applied two pulses. Since the central line is not quadrupolar broadened, it should not be involved in the echo formation. However, the central line peak always appears in experiments. This is explained qualitatively here by close examination on the time development of individual coherence. This explanation is used to predict the number of echoes that will be formed with 2 pulse sequence for nuclei of I=3/2, 5/2, 7/2, 9/2 with ease.

  • PDF

Comparison of in Vitro Cytotoxicity and Apoptogenic Activity of Magnesium Chloride and Cisplatin as Conventional Chemotherapeutic Agents in the MCF-7 Cell Line

  • Mirmalek, Seyed Abbas;Jangholi, Ehsan;Jafari, Mohammad;Yadollah-Damavandi, Soheila;Javidi, Mohammad Amin;Parsa, Yekta;Parsa, Tina;Salimi-Tabatabaee, Seyed Alireza;Kolagar, Hossein Ghasemzadeh;Jalil, Saeed Khazaei;Alizadeh-Navaei, Reza
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권sup3호
    • /
    • pp.131-134
    • /
    • 2016
  • Breast cancer is the most common malignancy and also the second leading cause of cancer death among women and also in women that have a high mortality. Previous studies showed that magnesium (Mg) has cytotoxic effects on malignant cell lines. However, the anti-cancer effects of Mg on MCF-7 breast cancer cells are uncertain. This study was aimed at the comparison of the cytotoxic effect of Mg salt (MgCl2) and cisplatin on MCF-7 cells and fibroblasts (as normal cells). After treatment with various concentrations of MgCl2, and cisplatin as a positive control for 24 and 48 hours (h), cytotoxicity activity was measured by MTT assay. In addition, apoptosis was determined by annexin V/propidium iide assay. Both cisplatin and the MgCl2 exhibited dose-dependent cytotoxic effects in the MCF-7 cell line, although the LD50 of the Mg was significantly higher when compared to cispaltin ($40{\mu}g/ml$ vs. $20{\mu}g/ml$). Regarding annexin V/propidium results, treatment of MCF-7 cells with LD50 concentrations of cisplatin and Mg showed 59% and 44% apoptosis at 24h, respectively. Finally, the results indicated that Mg has cytotoxic effects on MCF-7 cells, but less than cisplatin as a conventional chemotherapeutic agent. However, regarding the side effects of chemotherapy drugs, it seems that Mg can be considered as a supplement for the treatment of breast cancer.

분기선로가 있는 3상 전력선로하의 전자파 자계 계산 (Calculation of Magnetic Fields under 3 Phase Power Lines with Branch Lines)

  • 강대하;이영식;김부규
    • 조명전기설비학회논문지
    • /
    • 제23권5호
    • /
    • pp.110-119
    • /
    • 2009
  • 본 연구에서는 임의의 각도로 분기되어 있는 전력선로 근방의 자계를 유도하여 정식화 하였으며 이 공식을 이용함으로써 그 자계 계산을 쉽게 할 수 있다. 이 공식들은 분기선로가 있는 배전선로의 설계 시 검토자료로서 활용할 수 있을 것으로 생각된다. 예로서 자계요소에 관한 공식들을 분기선로가 있는 3상 배전선로 모델에 적용하여 메틀랩 프로그램에 의해 계산하였으며 그 결과를 제시하였다. 그 분석결과를 요약하면 다음과 같다. 합성자계는 분기각이 작고 관측점의 높이 z가 낮으면 전 y-축상에 걸쳐 By 요소가 지배적이다. 이 합성자계는 분기각 ${\alpha}=\frac{\pi}{2}$[rad]의 경우 Bx의 영향을 크게 받는다. 또한 이 합성자계는 전력선 높이와 같은 전선로 근방에서 Bz요소가 지배적이며 분기각이 ${\alpha}>\frac{\pi}{2}$[rad]의 경우에는 y축의 분기전선 위치에서 매우 큰 값을 나타낸다.

지중배전계통 보호를 위한 모의시험선로 서지특성 해석 (A Lightning Surge Analysis of Testing Line for Protection of Underground Distribution Systems)

  • 김병숙;이장근;이종범;한병성
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권8호
    • /
    • pp.313-321
    • /
    • 2006
  • This paper describes the overvoltage obtained by surge behavior analysis in testing underground distribution systems. Model systems consist of overhead distribution line and underground cable. Such model system considered various characteristics of actual distribution systems will be soon constructed at testing yard. Simulation is carried out under various states such as cable kinds, cable length, lightning wave and time, and branch circuits. Model is established by EMTP/ATPDraw. Line Constants are calculated by ATP_LCC. When the direct lightning surge strikes on conductor of overhead line, the overvoltage is calculated using EMTP/ATPDraw in many cases. Simulation results will be compared with real testing results at testing yard in the near future. The compared results will be used to establish protection methods in actual underground distribution systems.

Analysis of Poly(Ethylene-co-Vinyl Acetate) Using Off-line Pyrolysis

  • Choi, Sung-Seen;Kim, Eunha
    • Elastomers and Composites
    • /
    • 제51권1호
    • /
    • pp.63-67
    • /
    • 2016
  • Poly(ethylene-co-vinyl acetate) (EVA) was pyrolyzed to eliminate acetic acid of VA unit using off-line pyrolysis, and the deacetylated EVA was analyzed infrared spectroscopy (IR) and pyrolysis-gas chromatography/mass spectrometry (Py-GC/MS). EVA film for deacetylation was prepared by solution casting on aluminum foil and it was pyrolyzed at low temperature of $300^{\circ}C$ in the off-line pyrolysis apparatus. After deacetylation, carbon-carbon double bond (C=C) was formed by 1,2-elimination of the VA unit in the EVA backbone. Most of C=C bonds were trans-1,4-unit and 1,2-unit was also observed. Presence of the 1,2-unit in deacetylated EVA indicates that terminal or branch VA units exist in the raw EVA. Py-GC/MS chromatogram of deacetylated EVA displayed much smaller acetic acid and much more abundant other pyrolysis products than that of raw EVA, which means that the pyrolysis efficiency and separation condition were improved.

PN 시퀀스 방식의 광대역 임펄스 응답 측정을 통한 고압 배전선로 채널 특성 연구 (A Study On The Characteristics Of The Medium Voltage Power Distribution Line Channel By Wideband Channel Impulse Response Measurement Using PN Sequence)

  • 오휘명;최성수;이재조;김관호;황금찬
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제54권1호
    • /
    • pp.56-60
    • /
    • 2005
  • In the power-line communication(PLC) systems, the power line is a wired medium. However, the power line channel has the multi-path fading characteristics like the wireless channel in the wireless communication systems because it has the signal reflection and divergence by the impedance mismatching between many branch lines and loads. So the analysis of the multi-path characteristics is very important, and it has been doing by the several measurement methods for the impulse response between the transmitter and the receiver. PN sequence method has originally been used as a wideband impulse response measurement mettled for wireless channel, but it is recently being applied to not only the wireless channel but also the wired channel like the power line channel. This method is more useful and effective for the long distance communication channel like the medium voltage power distribution line with the multi-paths[1]. In this thesis, we have measured impulse response for the medium voltage power distribution line channel by the wideband measurement method using PN sequence, analytically studied the measured data and presented the results.

Comparison of High Frequency Detailed Generator Models for Partial Discharge Localization

  • Hassan Hosseini, S.M.;Hosseini Bafghi, S.M.
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권4호
    • /
    • pp.1752-1758
    • /
    • 2015
  • This paper presents partial discharge localization in stator winding of generators using multi-conductor transmission line (MTL) and RLC ladder network models. The high-voltage (HV) winding of a 6kV/250kW generator has been modeled by MATLAB software. The simulation results of the MTL and the RLC ladder network models have been evaluated with the measurements results in the frequency domain by applying of the Pearson’s correlation coefficients. Two PD generated calibrator signals in kHz and MHz frequency range were injected into different points of generator winding and the signals simulated/measured at the both ends of the winding. For partial discharge localization in stator winding of generators is necessary to calculate the frequency spectrum of the PD current signals and then estimate the poles of the system from the calculated frequency spectrum. Finally, the location of PD can be estimated. This theory applied for the above generator and the simulation/measured results show the good correlation for PD Location for RLC ladder network and MTL models in the frequency range of kHz (10kHz<f<1MHz) and MHz (1MHz<f<5MHz) respectively.

Estimation of Additive and Dominance Genetic Variances in Line Breeding Swine

  • Ishida, T.;Kuroki, T.;Harada, H.;Fukuhara, R.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제14권1호
    • /
    • pp.1-6
    • /
    • 2001
  • Additive and dominance genetic variances were estimated for purebred Landrace selected with line breeding from 1989 to 1995 at Miyazaki Livestock Experiment Station, Kawaminami Branch. Ten body measurements, two reproductive traits and fifteen carcass traits were analyzed with single-trait mixed model analysis. The estimates of narrow-sense heritabilities by additive model were in the range of 0.07 to 0.46 for body measurements, 0.05 to 0.14 for reproductive traits, and 0.05 to 0.68 for carcass traits. The additive model tended to slightly overestimate the narrow-sense heritabilities as compared to the additive and dominance model. The proportion of the dominance variance to total genetic variance ranged from 0.11 to 0.91 for body measurements, 0.00 to 0.65 for reproductive traits, and 0.00 to 0.86 for carcass traits. Large differences among traits were found in the ratio of dominance to total genetic variance. These results suggested that dominance effect would affect the expression of all ten body measurements, one reproductive trait, and nine carcass traits. It is justified to consider the dominance effects in genetic evaluation of the selected lines for those traits.