• Title/Summary/Keyword: Branch flow

Search Result 450, Processing Time 0.027 seconds

Characterization of Cement Mortar with Plastic Fine Aggregates (플라스틱 잔골재에 의한 시멘트 모르타르 기초 물성 평가)

  • Lee, Jun;Kim, Kyung-Min;Cho, Young-Keun;Kim, Ho-Kyu;Kim, Young-Uk
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.7 no.4
    • /
    • pp.383-388
    • /
    • 2019
  • The present study evaluated experimentally the effects of the type and content of plastic fine aggregates on cement mortar in order to utilize waste platics as raw materials of concrete. The two kinds of plastics, LLDPE and HDPE were used, and the mixing rate of plastic fine aggregates was increased 0, 25, 50, 75, 100%. The mortar of LLDPE fine aggregate and HDPE fine aggregate showed similar tendency in flow and material separation resistance, density and water absorption, compressive strength and flexural strength by age. The flowability of mortar mixed with plastic fine aggregates was increased up to 50% but decreased at 75% or more. The material separation resistance of mortar with plastic fine aggregates was also dramatically decreased. On the other hand, due to the low density of plastics, the density of mortar decreased with the mixing of plastic fine aggregates. Due to the low adhesion between plastic fine aggregates and cement, the compressive strength by age was decreased in proportion to the mixing ratio of plastic aggregate, but the flexural strength of each age decreased with maintaining a certain level at 50% or more of plastic fine aggregate content.

A Study on the Influence of Water Quality on the Upper Stream of Hap-Chun Lake (합천호 상류수계의 수질인자간 상관관계에 관한 고찰)

  • Park, Hyun-Geoun;Cha, Eun-Ha
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.2
    • /
    • pp.94-100
    • /
    • 2013
  • In this study, we have investigated the water quality and flow rate at the 3 sites of main stream and 11 sites of the branch stream of Hwang River from January, 2007 to 2010, and analyzed the effects on Hwang River with the purpose of using the data for as the fundamental information for water quality improvement and water resource management in the water system of Hap-Cheon Lake Upper Stream. The flow rate at 3 sites of the main stream and 11 sites of the branch stream increased during the rainy season between June and September, and continuously decreased during the dry season starting from autumn to winter. The results of correlation analysis with Pearson correlation coefficient showed that $BOD_5$ and $COD_{Mn}$, $BOD_5$ and T-P, and $COD_{Mn}$ and TSS at the 3 sites of the main stream had high correlation with each other. We have also analyzed the correlation between Chl-a and major factors at the 3 sites of the main stream. Chl-a and the water temperature Negative correlation coefficient and that of Chl-a and $BOD_5$, $COD_{Mn}$ Positive correlation coefficient showed. The N/P ratio at all the 3 sites of the main stream was higher than 16 by DIN/DIP and T-N/T-P, indicating that phosphorus is acting as the limited nutrient.

Evaluating appropriateness of the design methodology for urban sewer system (도시 하수관거 설계 방법의 적정성 평가)

  • Park, Ju-Hyun;Kim, Seon-Ho;Bae, Deg-Hyo
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.6
    • /
    • pp.411-420
    • /
    • 2019
  • The objective of this study is to evaluate the appropriateness of methodology for designing urban sewer system using a rational method-based model, Makesw and an urban runoff model, SWMM. The Gunja basin was selected as a study area and precipitation, runoff, vegetation, soil, imperviousness data were used to estimate floods. The appropriateness of methodology was evaluated based on comparison analysis between floods estimated from Makesw and SWMM. The comparison analysis was conducted between floods estimated from Makesw and SWMM, which were simulated using design rainfall and measured rainfall from past inundation events. The comparison results showed that in the case of design rainfall, the rational method-based floods were larger than that based on SWMM in all main lines. However in several branch lines, the rational method-based floods were smaller than thoes based on SWMM. In addition, for the case of measured rainfall from past inundation events, it was easily to find the main and branch lines where the rational method-based floods were smaller than SWMM based ones. Especially, the lines where rational method-based floods were underestimated, were mostly main, $1^{st}$, $2^{nd}$ lines. It was concluded that the rational method-based results were not conservative. Based on rational method (steady flow analysis) and SWMM (unsteady flow analysis), the more conservative results the method provides, the more highly it is recommended to use in designing an urban sewer system.

Cavitation Analysis on Ship Seawater Pump Using CFD (CFD를 이용한 선박용 해수펌프의 공동현상에 대한 분석)

  • Kim, Bu-Gi;Kim, Hong-Ryeol;Yang, Chang-Jo;Kim, Jun-Ho
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.4
    • /
    • pp.400-406
    • /
    • 2017
  • The model used in this study was reversed to analyze the cause of excessive damage that occurred inside the rotating system and pipe system of a centrifugal-type seawater pump on a ship. For this purpose, internal flow analysis on a cooling seawater pump was performed using CFD. As a result, the shape and boundary conditions of the target pump were set by reverse engineering, and pump efficiency at a design operating point of $125m^3/h$ was calculated as 85.3 % with a head of 32.0 m. The maximum efficiency point of the target pump was estimated to be 86.2 % at $150m^3/h$, but this differed from the actual operating point. At $112.5m^3/h$, which was the lowest flow point, flow was unstable due to the characteristics of the low flow point and analysis convergence was not good. The purpose of this study was to clarify the cause of ongoing cavitation in seawater pumps and piping systems in operation. Future research will be needed to clarify causes for pipe systems in the future by performing calculations for the total piping system of an inlet and outlet, in addition to measuring the flow rate of each branch pipe.

The Impact of Web Site Characteristics on e-Trust in Specialized Portal (전문포털의 웹사이트 특성이 e-신뢰에 미치는 영향)

  • Yoon Myeong-Sook;Kyung Jong-Soo
    • The Journal of the Korea Contents Association
    • /
    • v.6 no.7
    • /
    • pp.1-12
    • /
    • 2006
  • This study examined relationship of effect between the characteristics of specialized portal and two branch dimension(cognitive and emotional e-trust) of e-trust on the specialized portal web-site. The characteristics of specialized portal web-site composed the guarantee factor, the structural factor, information factor, the entertainment factor and the flow factor by prior research. The model of e-trust strategy for specialized portal web-site is tested here using data from 122 samples. Result of factor and regression analysis show that the hypothesized relationships are significant. In examining the relationships of the factors in the study, the guarantee, structural and information fact effect on building of cognitive e-Trust. Second, the entertainment and flow factor effect on emotional e- Trust. Third, the cognitive and emotional e- Trust effect on the satisfaction of e-Service users. As these results, this study found out difference paths of e-Trust which effect on the satisfaction of e-Service by cognitive and emotional e- Trust approaches to the specialized portal web - sites.

  • PDF

On the Origin of the Tsushima Current (I) : Barotropic Case (대마해류의 기원에 대하여 (I) : 순압인 경우)

  • PANG Ig-Chan;KIM Tae-Hee;MATSUNO Takeshi;RHO Hong-Kil
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.26 no.6
    • /
    • pp.580-593
    • /
    • 1993
  • The Tsushima Current has been known to branch out from the Kuroshio west of Kyushu and to flow north to the Korea Strait. Then, it has to flow across the isobaths and so needs some driving forces. As the forces, sea level difference between the Korea and Tsugaru Straits, Reynolds stress west of Kyushu and density differences have been suggested, In this paper, their roles have been numerically studied in the barotropic case. Model results show that the Tsushima Current is possible without any above force. The flows just follow isobaths over the East China Sea. They seem to be driven by their own dynamics without any external force. The mechanism is just like outflows from a gap. Model results also show that the flows in this area could be significantly affected by the external forces such as Reynolds Stress. Then the dynamics and flows in real ocean might be complicated. However, the barotropic study tells us that the Tsuahima Currents is basically driven by geostrophic adjustment.

  • PDF

Aeroelastic analysis of cantilever non-symmetric FG sandwich plates under yawed supersonic flow

  • Hosseini, Mohammad;Arani, Ali Ghorbanpour;Karamizadeh, Mohammad Reza;Afshari, Hassan;Niknejad, Shahriar
    • Wind and Structures
    • /
    • v.29 no.6
    • /
    • pp.457-469
    • /
    • 2019
  • In this paper, a numerical solution is presented for supersonic flutter analysis of cantilever non-symmetric functionally graded (FG) sandwich plates. The plate is considered to be composed of two different functionally graded face sheets and an isotropic homogeneous core made of ceramic. Based on the first order shear deformation theory (FSDT) and linear piston theory, the set of governing equations and boundary conditions are derived. Dimensionless form of the governing equations and boundary conditions are derived and solved numerically using generalized differential quadrature method (GDQM) and critical velocity and flutter frequencies are calculated. For various values of the yaw angle, effect of different parameters like aspect ratio, thickness of the plate, power law indices and thickness of the core on the flutter boundaries are investigated. Numerical examples show that wings and tail fins with larger length and shorter width are more stable in supersonic flights. It is concluded for FG sandwich plates made of Al-Al2O3 that increase in volume fraction of ceramic (Al2O3) increases aeroelastic stability of the plate. Presented study confirms that improvement of aeroelastic behavior and weight of wings and tail fins of aircrafts are not consistent items. It is shown that value of the critical yaw angle depends on aspect ratio of the plate and other parameters including thickness and variation of properties have no considerable effect on it. Results of this paper can be used in design and analysis of wing and tail fin of supersonic airplanes.

A Study on Hydraulic Calculation Procedure of Fire Sprinkler System Design (스프링클러설비 설계의 수리계산 절차에 대한 연구)

  • Jeong, Keesin
    • Fire Science and Engineering
    • /
    • v.32 no.1
    • /
    • pp.24-32
    • /
    • 2018
  • There are two kinds of method on hydraulic calculation of fire sprinkler system design. The one is using the computational program and the other is designer calculate system for oneself. In case of using the computational program, putting the input data in, the program calculate the friction loss, water flow, total height and so forth. If program user or designer doesn't know the basic idea and procedure of hydraulic calculation. Then, the outputs are different from each other. This paper suggests the hydraulic calculation procedure in design area as follow. Equivalent lengths of tees on the branch are selected base on the same pipe diameter which the tees are established, although the diameter of tee outlet is different. Even though there is a different friction loss of head from the other head, the pressure from the hydraulic end is bigger than a head loss, discharge flow is calculated by pressure from the hydraulic end.

A Presentation on the Manual Hydraulic Calculation Method of the Loop Type Fire Sprinkler System (Loop형 스프링클러 설비의 수리계산 방법에 대한 제시)

  • Jeong, Keesin
    • Fire Science and Engineering
    • /
    • v.29 no.1
    • /
    • pp.73-79
    • /
    • 2015
  • There are three kinds of design method of the fire sprinkler systems. Grid type is connected all branch as a trapezoid. Loop type is connected cross-mains like circle. The last one is a tree type most commonly used. Grid type needs computer program to calculate the friction loss and flow rate apart from very simple form. In loop type, manual calculation is possible. Design engineer can draw up and calculate the demands without computer program. Because water supplies two direction in loop type, friction loss is smaller than tree type. Water distribution in operation area is uniform because of the small differences of sprinklers discharge pressure. Loop type is superior to tree type in respect of total pressure and flow rate. Using the small diameter pipe, the labor and construction cost will be decreased in the end. Loop type sprinkler design is rarely laid out because design engineers don't know the method. This paper is intended to inform that the loop type is better than the tree type in performance and economic point of view. And also this paper intend to use the loop type easily and widely.

Effect of the circle tunnel on induced force distribution around underground rectangular gallery using theoretical approach, experimental test and particle flow code simulation

  • Vahab, Sarfarazi;Reza, Bahrami;Shadman Mohammadi, Bolbanabad;Fariborz, Matinpoor
    • Structural Engineering and Mechanics
    • /
    • v.84 no.5
    • /
    • pp.633-649
    • /
    • 2022
  • In this study, the effect of circle tunnel on the force distribution around underground rectangular gallery was investigated using theoretical approach, experimental test and Particle flow code simulation (PFC). Gypsum model with dimension of 1500×1500 mm was built. Tensile strength of material was 1 MPa. Dimension of central gallery was 100 mm×200 mm and diameter of adjacent tunnel in its right side was 20 mm, 40 mm and 60 mm. Horizontal distance between tunnel wall and gallery edge were 25, 50, 75, 100 and 125 mm. using beam theory, the effect of tunnel diameter and distance between tunnel and gallery on the induced force around gallery was analyzed. In the laboratory test, the rate of loading displacement was set to 0.05 millimeter per minute. Also sensitivity analysis has been done. Using PFC2D, interaction between tunnel and gallery was simulated and its results were compared with experimental and theoretical analysis. The results show that the tensile force concentration has maximum value in center of the rectangular space. The tensile force concentration at the right side of the axisymmetric line of gallery has more than its value in the left side of the galleries axisymmetric line. The tensile force concentration was decreased by increasing the distance between tunnel and rectangular space. In whole of the configurations, the angles of micro cracks fluctuated between 75 and 105 degrees, which mean that the variations of tunnel situation have not any influence on the fracture angle.