• Title/Summary/Keyword: Branch electrode

Search Result 36, Processing Time 0.019 seconds

Characteristics of Trigeminal Evoked Potential and It's Pathway in the Rat (백서에서 삼차신경 유발전위의 특성과 경로 분석)

  • Kim, Se-Hyuk;Zhao, Chun-Zhi;Kwon, Oh-Kyoo;Lee, Bae-Hwan;Park, Yong-Gou;Chung, Sang-Sup
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.8
    • /
    • pp.985-994
    • /
    • 2000
  • Objective : There are some advantages of trigeminal evoked potential(TEP) recording compared to other somatosensory evoked potential(SSEP) recordings. The trigeminal sensory pathway has a pure sensory nerve branch, a broader receptive field in cerebral cortex, and a shorter pathway. Despite these advantages, there is little agreement as to what constitutes a normal response and what wave forms truly characterize the intraoperative TEP. This study presents the normative data of TEP recorded on the epidural surface of the rat with a platinum ball electrode. Materials & Methods : Under general anesthesia with urethane, the adult Sprague-Dawley male rats(300-350g) were given electrical stimulation with two stainless steel electrodes which were inserted into the subcutaneous layer of the area around whiskers. A reference electrode was positioned in the temporalis muscle ipsilateral to the recording site. Results : TEPs were recorded in the Par I area of somatosensory cortex and recorded most apparently on the point of 2mm posterior from the bregma and 6mm lateral from the midline. The typical wave form consisted of 5 peaks (N1-P1-N2-P2-N3 according to emerging order, upward negativity). Each latency to corresponding peaks was not influenced by the different intensities of stimulation, especially from 1 to 5mA. Average latencies of 5 peaks were in the following order ; 7.7, 11.1, 15, 22.3, 29.4ms. There was also no significant difference between latencies before and after administration of muscle relaxant(pancuronium). For the electrophysiological localization of recorded waves, the action potential of a single unit was recorded with glass microelectrode(filled with 2M NaCl, $3-5M{\Omega}$) in the thalamus of rat. A sharp wave was recorded in the VPM nucleus, in which the latency was shorter than that of N1. This suggests that all 5 peaks were generated by neural activities in the suprathalamic pathway. Conclusion : In terms of recording near-field potentials, our data also suggests that TEP in the rat may be superior to other SSEPs. In overall, these results may afford normative data for the studies of supratentorial lesions such as hydrocephalus or cerebral ischemia which can have an influence on near-field potentials.

  • PDF

Analysis and Improvement of Experiments for Electrolysis of an Aqueous CuCl2 Solution in High School Science Textbooks (고등학교 과학 교과서에 제시된 염화구리(II) 수용액의 전기분해 실험의 분석 및 개선)

  • Park, Guk-Tae;Jo, Yeong-Ja;Lee, Ji-Yeong;Park, Gwang-Seo
    • Journal of the Korean Chemical Society
    • /
    • v.50 no.4
    • /
    • pp.328-337
    • /
    • 2006
  • purpose of this study was to find out problems in experiments for electrolysis of an aqueous CuCl2 solution in high school science textbooks and to suggest an improved experiment considering students' capability of experimenting and laboratory safety in high schools. For this study, the experiments for electrolysis of an aqueous CuCl2 solution presented in 11 high school science textbooks were classified by their experimental methods. After high school chemistry teachers performed the experiments as presented in the high school science textbooks, an analysis was performed on problems of the experiments, and an improved experiment was devised. According to the results of this study, in the experiments for electrolysis of an aqueous CuCl2 solution using a U type tube and a U type tube with branch, reaction velocity of the electrolysis was slow, therefore, a side reaction was generated. In the experiment using a beaker, reaction of each electrode could not be observed separately. And in the experiment using an electrolysis instrument, it was difficult to identify property of the reaction product. In the improved experiment using a reaction vessel of ㅂshape, reaction velocity of the electrolysis was fast, reaction of each electrode could be observed separately, and the side reaction decreased. From these results, it was suggested that the improved experiment would help high school students understand scientific conception regarding electrolysis.

Zn2+ PVC-based Membrane Sensor Based on 3-[(2-Furylmethylene)amino]-2-thioxo-1,3-thiazolidin-4-one

  • Ganjali, Mohammad Reza;Zamani, Hassan Ali;Norouzi, Parviz;Adib, Mehdi;Rezapour, Morteza;Aceedy, Mohammad
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.4
    • /
    • pp.579-584
    • /
    • 2005
  • The 3-[(2-furylmethylene)amino]-2-thioxo-1,3-thiazolidin-4-one (FTT) was used as an excellent ionophore in construction of a $Zn^{2+}$ PVC-based membrane sensor. The best performance was obtained with a membrane composition of 30% poly(vinyl chloride), 62% nitrobenzen (NB), 3% FTT and 5% sodium tetraphenyl borate (TBP). This membrane sensor shows very good selectivity and sensitivity towards $Zn^{2+}$ over a wide variety of cations, including alkali, alkaline earth, transition and heavy metal ions. The membrane sensor revealed a great enhancement in selectivity coefficients for $Zn^{2+}$ ions, in comparison to the previously reported $Zn^{2+}$ membrane sensors. Theoretical studies also showed the selective interaction of TFF and $Zn^{2+}$ ions. The proposed membrane sensor exhibits a Nernstian behavior (with slope of 29.3 ${\pm}$ 0.3 mV per decade) over a wide concentration range (1.0 ${\times}$ $10^{-6}$-1.0 ${\times}$ $10^{-2}$) with a detection limit of 8.5 ${\times}$ $10^{-7}$ M (52 ng mL$^{-1}$). It shows relatively fast response time, in the whole concentration range ($\lt$ 20 s), and can be used for at least 10 weeks in a pH range of 3.0-7.0. The proposed membrane sensor was successfully used in direct determination of $Zn^{2+}$ ions in wastewater of industrial zinc electroplating companies, and also as an indicator electrode in titration with EDTA.

Atrial pacemaker implantation through left subclavian vein puncture (쇄골하정맥을 이용한 J 형의 전극도자를 가진 심방 Pacemaker 이식치험 2예)

  • Lee, Du-Yeon;Hong, Seung-Rok;Lee, Ung-Gu
    • Journal of Chest Surgery
    • /
    • v.16 no.2
    • /
    • pp.190-198
    • /
    • 1983
  • The management of cardiac arrhythmias by cardiac pacing has increased greatly since the treatment of complete heart block with an external transcutaneous pacemaker in 1952, followed by the use of myocardial wires connected to an external pulse generation, by external transvenous pacing, and then by transvenous pacing with implantable components in thoracic wall.By now, the three bases of modern cardiac pacing for bradyarrhythmias had been established [1] an implantable device [2] the transvenous approach [3] the ability of the pacemaker to sense cardiac activity and modify its own function accordingly. In transvenous implantation of a pacemaker, any one of four vessels at the root of the neck is suitable for passage of the electrode - cephalic vein, external jugular vein, internal jugular vein, costo-axillary branch of the axillary vein. The new technique of direct puncture of the subclavian vein, either percutaneously or after skin incision only has been made, is invaluable & is used routinely. We have experienced one 25 years old patient who had rheumatic mitral stenosis & minimum aortic regurgitation with sinus bradycardia associated with premature atrial tachycardia & another 54 years old female patient who was suffered from sick sinus syndrome with sinus bradycardia & sinus arrest. The 1st patient was taken open mitral commissurotomy & aortic valvuloplasty and then was taken atrlal pace-maker implantation through If subclavian puncture method in post-op 14 days, and the second patient was taken atrial pacemaker implantation through If subclavian puncture method. Their postop course was in uneventful & were discharged, without complication. Their condition have been good to now.

  • PDF

Electrochemical Behaviors for Cathodic Reaction of N'-aryl-N-alkyl-N-nitrosourea Drivatives (N'-aryl-N-alkyl-N-nitrosourea 유도체의 환원반응에 대한 전기화학적 거동)

  • Won, Mi Sook;Kim, Jack C.;Jeong, Euh Duck;Shim, Yoon-Bo
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.11
    • /
    • pp.842-847
    • /
    • 1995
  • The electrochemical reduction reactions of N '-aryl-N-alkyl-N-nitrosourea derivatives with a glassy carbon electrode were diffusion controlled and irreversible. The exchange kinetic constant ko values for reduction reaction of the N '-aryl-N-alkyl-N-nitrosoureas were at the range of $1.48{\times}10^{-6}{\sim}5.32{\times}10^{-7}\;cm/sec.$ The $k_0$ values for phenyl substituted on the aryl position were about 1.3∼2.8 times higher than that of other substituents. The same substituent for aryl groups on the both of N '-aryl-N-alkyl-N-nitrosourea and N '-aryl-N-(2-chloroethyl)-N-nitrosourea exhibited same value. The $E_p$ value was shifted to the negative direction as pH increased. The number of protons participated to the reduction was 4∼5, respectively. The substituent effect of aryl group on the reduction potential was not observed in this case.

  • PDF

Electrical Pulses of Internal Partial Discharges Accompanying with Electrical Tree in LDPE (LDPE에서 발생된 전기트리에 수반된 내부 부분방전 펄스 해석)

  • Kang, S.H.;Park, Y.G.;Kwon, S.S.;Shin, T.S.;Lim, K.J.
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.1
    • /
    • pp.216-221
    • /
    • 1999
  • The correlation between propagation of electrical tree and internal partial discharges is discussed. We use specimens with needle-plane electrode system made of LDPE(Low Density Polyethylene), observed inception and propagation of electrical tree by optical microscope and investigated the characteristics of the partial discharge (PD) pulses accompanying with propagation of electrical tree. In the specimens with needle-shaped void, the tree propagates branch type. The length of the tree has good linear relation with average discharge power of PD pulses. In the specimens without needle-shaped void, the tree grows bush type tree. The correlation between the area of the tree and the average discharge power of PD pulses has linear relation.

  • PDF