• 제목/요약/키워드: Brain Technology

검색결과 1,277건 처리시간 0.023초

비선형 상관차원 분석을 통한 EEG 뇌파신호 특성 추출

  • 강근;이형
    • Journal of Information Technology Applications and Management
    • /
    • 제9권4호
    • /
    • pp.165-177
    • /
    • 2002
  • For measuring EEG with the international 10-20 electrode system on 16 channels, and to analyze the interrelationship between the original signals and the changed signals after the stimulation, we use the scent of lavender which stimulates the olfactory sense. Moreover, the effect of the scent stimulation to the brain is analyzed. The purpose of this analysis is to apply these results to the computerized mapping of the brain signals and to find possible ways of specifying the source of the brain signals through various medical applications.

  • PDF

두개골-선조체 팬텀을 이용한 선량 저감화 방안 연구 (The Study of Radiation Exposure Reduction by Developing Corpus Striatum Phantom)

  • 김정수;박찬록
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권4호
    • /
    • pp.595-603
    • /
    • 2017
  • 본 연구는 파킨슨질환의 진행 정도를 평가할 수 있는 선조체를 모사한 brain 팬텀을 직접 제작하여, PET-CT검사 시 최적의 영상의 질을 유지하면서 CT 스캔에 의한 brain 선량 저감을 위한 가능성을 평가하였다. 팬텀의 hot sphere와 background (radi oacti vi ty rati o 3:1)에 $^{18}F$ FP-CIT를 주입하고, 관전압(100, 120 kVp)과 관전류(80, 140, 200 mAs)의 조건을 변화시키며 CT 스캔을 실험하였다(기준조건; 120 kVp, 140 mAs). 각 조건에 따라 예상유효선량을 conversion factor를 적용해 계산하였고, SNR과 CRChot의 영상평가 인자를 설정하여 영상의 질을 평가하였다. 실험결과 CT 촬영 기준조건 이하에서의 예상유효선량은 최소 10%에서 최고 60% 정도 감소하였고, 기준조건 이상에서의 예상유효선량은 40% 증가하였다. 또한 PET 영상의 SNR과 CRChot의 유의한 차이는 없었으므로, 관전압과 관전류의 감소에 따라 brain 선량이 감소함을 확인하였다. 이와 동시에 스캔 조건의 변화에도 불구하고 SNR과 CRChot 측면에서의 영상의 질에는 유의한 변화가 없었다. 이러한 사실은 낮은 선량 조건으로도 기존의 선량 조건으로 획득한 영상의 질 수준을 얻을 수 있었으므로, 추후 brain PET-CT 스캔의 선량감소와 동시에 영상의 질 향상에 관한 연구의 기초자료로 활용이 가능할 것으로 사료된다.

얼굴 추적 기반의 잡파 혼입 방지가 가능한 뇌파 DB구축 시스템 구현 (An Implementation of Brain-wave DB building system for Artifacts prevention using Face Tracking)

  • 신정훈;권형오
    • 융합신호처리학회논문지
    • /
    • 제10권1호
    • /
    • pp.40-48
    • /
    • 2009
  • 컴퓨터를 중심으로 한 IT 기술의 비약적인 발전과 더불어, 정보산업사회가 고도화되어 감에 따라 사용자 편리를 위한 인터페이스의 지능화, 인간화에 대한 요구가 나날이 증가하고 있다. 이러한 사용자의 요구에 따라 다양한 형태의 인간친화형 사용자 인터페이스 중, 인간의 뇌를 활용한 사용자 인터페이스 즉, BCI에 관한 연구가 최근 산발적으로 다양하게 진행되고 있다. 최근 연구 개발중인 다양한 형태의 BCI 관련 연구들은 DB구축과 관련된 원천기술 확보 측면의 연구가 배제된 체 응용기술 개발 위주로 진행되고 있는 실정이다. 이와 같은 문제점으로 인하여 BCI 관련 연구들은 연구 초기 수준을 극복하지 못하고 있으며, 체계적인 연구가 진행되어지지 않고 있는 실정이다. BCI 관련 연구의 경우 피험자로부터 수집되어지고 있는 뇌파 신호가 실험에 필요한 적절하고 의미 있는 신호인지 구분하기 힘든 실정이다. 또한, 뇌파 수집 시 실험에 불필요한 행동 즉, 심한 눈 깜박임, 침 삼키기, 얼굴 및 몸 움직임에 의한 근전도와 전극의 부착상태, 주변소음, 진동 둥 실험환경에 따른 잡파의 혼입으로 인하여 정확한 뇌파 DB수집에 어려움을 겪고 있다. 이러한 피험자의 움직임 및 실험환경에 의해 혼입된 잡파의 손상된 정보로 인해 BCI 시스템 구현 시 인식률 및 성능저하를 초래할 수 있다. 따라서 본 논문에서는 뇌파를 활용한 BCI 시스템 구현 시 보다 정확하고 높은 인식률을 위한 기반 연구로서 정확하고 효율적인 뇌파 DB구축 시스템을 제안하며, 잡파가 혼입된 뇌파 DB의 최소화를 위해 피험자의 얼굴 추적을 통하여 불필요한 행동 발생 시 DB수집의 사전 차단 및 자동 제어가 가능한 DB구축 시스템을 제안한다.

  • PDF

3D 프린팅 기법 기반의 Hoffman Brain 팬텀 개발 및 유용성 평가 (Development and Evaluation of the Usefulness for Hoffman Brain Phantom Based on 3D Printing Technique)

  • 박훈희;이주영
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권6호
    • /
    • pp.441-446
    • /
    • 2019
  • The purpose of this paper is to recognize the usefulness of the Phantom produced with 3D printing technology by reproducing the original phantom with 3D printing technology. Using CT, we obtained information from the original phantom. The acquired file was printed by the SLA method of ABS materials. For inspection, SPECT/CT was used to obtain images. We filled the both Phantom with a solution mixed with 99mTcO4 1 mCi in 1 liter of water and acq uired images in accordance with the standard protocol. Using Image J, the SNR for each slice of the image was obtained. As a reference images, AC images were used. For the analysis of acquired images, ROI was set in the White mater and Gray mater sections of each image, and the average Intensity Value within the ROI were compared. According to the results of this study, 3D printed phantom's SNR is about 0.1 higher than the conventional phantom. And the ratio of Intensity Value was shown in the original 1 : 3.4, and the printed phantom was shown to be 1 : 3.2. Therefore, if Calibration Value is applied, It is assumed that it can be used as an alternative to the original.

Ginsenoside compound K reduces the progression of Huntington's disease via the inhibition of oxidative stress and overactivation of the ATM/AMPK pathway

  • Hua, Kuo-Feng;Chao, A-Ching;Lin, Ting-Yu;Chen, Wan-Tze;Lee, Yu-Chieh;Hsu, Wan-Han;Lee, Sheau-Long;Wang, Hsin-Min;Yang, Ding-I.;Ju, Tz-Chuen
    • Journal of Ginseng Research
    • /
    • 제46권4호
    • /
    • pp.572-584
    • /
    • 2022
  • Background: Huntington's disease (HD) is a neurodegenerative disorder caused by the expansion of trinucleotide CAG repeat in the Huntingtin (Htt) gene. The major pathogenic pathways underlying HD involve the impairment of cellular energy homeostasis and DNA damage in the brain. The protein kinase ataxia-telangiectasia mutated (ATM) is an important regulator of the DNA damage response. ATM is involved in the phosphorylation of AMP-activated protein kinase (AMPK), suggesting that AMPK plays a critical role in response to DNA damage. Herein, we demonstrated that expression of polyQ-expanded mutant Htt (mHtt) enhanced the phosphorylation of ATM. Ginsenoside is the main and most effective component of Panax ginseng. However, the protective effect of a ginsenoside (compound K, CK) in HD remains unclear and warrants further investigation. Methods: This study used the R6/2 transgenic mouse model of HD and performed behavioral tests, survival rate, histological analyses, and immunoblot assays. Results: The systematic administration of CK into R6/2 mice suppressed the activation of ATM/AMPK and reduced neuronal toxicity and mHTT aggregation. Most importantly, CK increased neuronal density and lifespan and improved motor dysfunction in R6/2 mice. Conversely, CK enhanced the expression of Bcl2 protected striatal cells from the toxicity induced by the overactivation of mHtt and AMPK. Conclusions: Thus, the oral administration of CK reduced the disease progression and markedly enhanced lifespan in the transgenic mouse model (R6/2) of HD.

의료영상 촬영을 위한 비용-효율적인 신경조절 장비 (Cost-Effective Neuro-Modulation Device for Medical Imaging)

  • 황승민;최영빈;이기현;정영진
    • 한국방사선학회논문지
    • /
    • 제17권7호
    • /
    • pp.1165-1170
    • /
    • 2023
  • 본 연구는 신경과학과 임상의학 분야에서 의료영상 촬영에 활용될 수 있는 비용-효율적인 뇌 신경조절 장비 개발하고자 하였습니다. 이를 위해, 500달러 미만의 재료비로 뇌 신경조절 장비를 설계하고, 이를 제작하여, 그 성능을 평가하였다. 측정된 성능평가 결과는 기존 의료기기와 유사하였으며, 그 크기는 3 cm by 3 cm 이하로 개발하였다. 본 연구의 결과는 관련 분야의 연구 개발 및 신경 자극 기술의 신속한 상용화 등에 활용될 수 있을 것이라 기대됩니다. 또한 기능적 방사선 의료영상 기술의 발전 및 뇌과학 및 뇌 자극기술 개발의 접근성 향상에 기여할 것으로 기대됩니다.

Decoding Brain Patterns for Colored and Grayscale Images using Multivariate Pattern Analysis

  • Zafar, Raheel;Malik, Muhammad Noman;Hayat, Huma;Malik, Aamir Saeed
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제14권4호
    • /
    • pp.1543-1561
    • /
    • 2020
  • Taxonomy of human brain activity is a complicated rather challenging procedure. Due to its multifaceted aspects, including experiment design, stimuli selection and presentation of images other than feature extraction and selection techniques, foster its challenging nature. Although, researchers have focused various methods to create taxonomy of human brain activity, however use of multivariate pattern analysis (MVPA) for image recognition to catalog the human brain activities is scarce. Moreover, experiment design is a complex procedure and selection of image type, color and order is challenging too. Thus, this research bridge the gap by using MVPA to create taxonomy of human brain activity for different categories of images, both colored and gray scale. In this regard, experiment is conducted through EEG testing technique, with feature extraction, selection and classification approaches to collect data from prequalified criteria of 25 graduates of University Technology PETRONAS (UTP). These participants are shown both colored and gray scale images to record accuracy and reaction time. The results showed that colored images produces better end result in terms of accuracy and response time using wavelet transform, t-test and support vector machine. This research resulted that MVPA is a better approach for the analysis of EEG data as more useful information can be extracted from the brain using colored images. This research discusses a detail behavior of human brain based on the color and gray scale images for the specific and unique task. This research contributes to further improve the decoding of human brain with increased accuracy. Besides, such experiment settings can be implemented and contribute to other areas of medical, military, business, lie detection and many others.

클라우드 IoT를 이용한 뇌-기계 인터페이스 시스템 구현 (Implementation of Brain-machine Interface System using Cloud IoT)

  • 김훈희
    • 사물인터넷융복합논문지
    • /
    • 제9권1호
    • /
    • pp.25-31
    • /
    • 2023
  • 뇌-기계 인터페이스는 차세대 인터페이스로서 기기 이용자가 명령을 생각할 때 발생하는 신경세포의 전기적 신호인 뇌파를 해석하여 기기를 조종하는 인터페이스다. 뇌-기계 인터페이스는 다양한 스마트기기 등에 응용될 수 있지만 뇌파 신호를 해석하는 데는 상당량의 계산 프로세스가 필요하다. 따라서 에지(Edge) 형태로 구현된 임베디드 시스템에서는 뇌-기계 인터페이스를 구현하기가 어렵다. 본 연구에서는 사물인터넷 기술을 이용하여 에지에서는 뇌파 측정만을 진행하고 뇌파 데이터의 저장 및 분석은 클라우드 컴퓨팅에서 수행하는 새로운 형태의 뇌-기계 인터페이스 시스템을 제안하였다. 본 시스템은 뇌-기계 인터페이스를 위한 정량 뇌파 분석을 성공적으로 수행하였으며 데이터 송수신 시간 또한 실시간 처리가 가능한 수준을 보였다.

라벤더 향 자극에 대한 EEG 생체신호의 비선형 분석 (A Study on EEG bionic signals management for using the non-linear analysis methods)

  • 강근;안광민;이형
    • 한국정보기술응용학회:학술대회논문집
    • /
    • 한국정보기술응용학회 2002년도 추계공동학술대회 정보환경 변화에 따른 신정보기술 패러다임
    • /
    • pp.461-467
    • /
    • 2002
  • 뇌에서 얻은 시계열 신호들은 대부분 불규칙하고 복잡한 파형을 가지고 있으며, 1980년대 중반까지만 해도 이러한 신호들은 확률론 과정(stochastic process)으로 발생된 '소음'(noise)으로 여겨졌다. 하지만 최근 들어 뇌에 관한 연구가 활발히 진행되었고 EEG를 이용한 생체신호의 비선형분석에 관한 연구가 진행되면서 뇌에서 발생되는 신호는 의미 있는 신호로 분석되어지고 있다. 이에 비선형 분석방법인 상관차원을 이용하여 라벤더 향기 전과 향기 후의 뇌파의 변화를 분석하고, 주파수 대역별로 delta파, theta파, alpha파, beta파로 나누어서 라벤더 향이 뇌에 미치는 영향을 분석한다. 즉, 뇌에서 발생되는 신호의 특징을 찾기 위해 다른 향보다 강하게 반응하는 라벤더 향을 후각자극으로 제시하여 EEG를 측정한 후, 16채널에 대한 상관차원을 구하고 라벤더 향이 뇌에 미치는 영향을 분석한다.

  • PDF