• 제목/요약/키워드: Bracket shear bond strength

검색결과 89건 처리시간 0.022초

The effect of casein phosphopeptide amorphous calcium phosphate on the in vitro shear bond strength of orthodontic brackets

  • Park, Sun-Youn;Cha, Jung-Yul;Kim, Kyoung-Nam;Hwang, Chung-Ju
    • 대한치과교정학회지
    • /
    • 제43권1호
    • /
    • pp.23-28
    • /
    • 2013
  • Objective: The purpose of this study was to evaluate the effect of casein phosphopeptide amorphous calcium phosphate (CPP-ACP) on the shear bond strength (SBS) of brackets bonded to non-demineralized teeth with either phosphoric acid etching or self-etching primer. Methods: Sixty human premolars were randomly assigned to 1 of 4 treatment groups (n = 15 each): phosphoric acid etching (group 1); self-etching primer (group 2); CPP-ACP for 2 weeks + phosphoric acid etching (group 3), and CPP-ACP for 2 weeks + self-etching primer (group 4). After bonding of the maxillary premolar metal brackets, specimens were subjected to shear forces in a testing machine. Scanning electron microscopy was used to observe etching patterns on the enamel surfaces of all teeth. A 2-way analysis of variance was used to test for effects of CPP-ACP and etching system on SBS. Results: Significantly higher mean SBSs were observed in groups subjected to phosphoric acid etching (i.e., groups 1 and 3; p < 0.05). On the other hand, SBSs did not appear to be influenced by CPP-ACP (i.e., groups 3 and 4; p > 0.05). We observed a uniform and clear etched pattern on the enamel surface of the phosphoric acid etching groups. Conclusions: CPP-ACP does not significantly affect the SBS of orthodontic brackets bonded to non-demineralized teeth, regardless of which adhesive method is used to bond the brackets.

Plasma arc curing system을 이용한 브라켓의 접착에 관한 연구 (A STUDY ON THE SHEAR BOND STRENGTH BY PLASMA ARC CURING SYSTEM FOR BRACKET BONDING)

  • 김정윤;김종수;권순원
    • 대한소아치과학회지
    • /
    • 제28권4호
    • /
    • pp.638-642
    • /
    • 2001
  • 최근에 소개된 Plasma arc lamp를 이용한 고광도 광조사기는 조사되는 광도를 크게 증가시켜 필요한 조사시간을 단축시키고자하는 연구의 결과중 하나이다. 교정 임상에서 브라켓의 접착시 고광도 광조사기를 사용하여 시술시간을 줄인다면 환자뿐만 아니라, 술자에게도 시간적이나 경제적으로 많은 도움을 줄 것이다. 이 연구의 목적은 Plasma arc light를 사용하여 접착시킨 브라켓의 치면에 대한 전단강도를 측정하고 이를 기존의 할로겐 램프를 이용한 광중합 방법과 비교해보기 위함이다. I군은 할로겐 램프를 사용하는 $XL3000^{(R)}$을 이용하여 총 50초간 광중합하였고 II군은 plasma arc lamp를 사용하는 $Flipo^{(R)}$를 이용하여 2초간 광중합하였으며 III군도 $Flipo^{(R)}$를 이용하여 총 5초간 광중합하여 전단강도 측정을 시행한 결과는 다음과 같다. 1. 세 군의 전단강도의 평균은 비슷한 수치를 나타내었다. 2. 세 군간의 통계학적 유의 차가 없었다(p>0.05).

  • PDF

직접 부착법과 간접 부착법이 열순환 후 부착강도와 미세누출에 미치는 영향에 대한 연구 (Effects of direct and indirect bonding techniques on bond strength and microleakage after thermocycling)

  • Ozturk, Firat;Babacan, Hasan;Nalcaci, Ruhi;Kustarci, Alper
    • 대한치과교정학회지
    • /
    • 제39권6호
    • /
    • pp.393-401
    • /
    • 2009
  • 본 연구는 직접 또는 간접 부착법으로 부착한 교정용 브라켓을 열순환 처리 후에 전단 결합 강도(shear bond strength, SBS)와 치아-접착제-브라켓 복합체의 미세 누출을 비교하기 위하여 시행하였다. 50개의 치아우식증이 없는 사람 소구치를 구하여 동등한 2개의 군으로 나누었다. 직접 부착군에서는 광중합 접착제 및 primer (Transbond XT)를 사용하였고 간접 부착군에서는 광중합 접착제와(Transbond XT) 화학중합 primer (Sondhi Rapid Set)를 사용하였다. 중합 후에 치아는 24시간 동안 증류수에 보관하였고 이후 500회 열순환 처리를 하였다. 미세누출의 평가를 위해 각 군에서 10개의 치아에 nail varnish로 추가 봉연을 실시하고 0.5% basic fuchsin에 24시간 동안 염색한 후 입체현미경으로 검경하였다. 만능시험기를 이용하여 각 군의 치아 15개로 SBS를 계측하였고 adhesive remnant index (ARI)를 평가하였다. 결과 자료는 Mann-Whitney U test, Chi-square test, Fisher's exact test로 통계 분석하였다. 직접 부착군과 간접 부착군 사이에 SBS 및 미세누출의 통계적으로 유의한 차이는 보이지 않았으며 간접 부착군에서 통계적으로 유의하게 ARI 점수가 낮았다. 브라켓의 탈락은 법랑질-레진 계면에서 발생하였다. 이상의 결과로 보아 부착법의 차이는 미세누출의 양과 SBS에 유의한 영향을 미치지 않는다.

Evaluation of different enamel conditioning techniques for orthodontic bonding

  • Turkoz, Cagri;Ulusoy, Cagri
    • 대한치과교정학회지
    • /
    • 제42권1호
    • /
    • pp.32-38
    • /
    • 2012
  • Objective: The aim of this study was to compare the effects of different enamel conditioning techniques for bracket bonding. Methods: Ninety-one human premolars were randomly divided in six groups of 15 specimens each. The enamel surfaces of the teeth were etched with 35% orthophosphoric acid in Group 1, with a self-etching primer in Group 2, sandblasted in Group 3, sandblasted and etched with 35% orthophosphoric acid in Group 4, conditioned by Er:YAG laser in Group 5 and conditioned by Er:YAG laser and etched with 35% phosphoric acid gel respectively in Group 6. After enamel conditioning procedures, brackets were bonded and shear bonding test was performed. After debonding, adhesive remnant index scores were calculated for all groups. One tooth from each group were inspected by scanning electron microscope for evaluating the enamel surface characteristics. Results: The laser and acid etched group showed the highest mean shear bond strength (SBS) value ($13.61{\pm}1.14$ MPa) while sandblasted group yielded the lowest value ($3.12{\pm}0.61$ MPa). Conclusions: Although the SBS values were higher, the teeth in laser conditioned groups were highly damaged. Therefore, acid etching and self-etching techniques were found to be safer for orthodontic bracket bonding. Sandblasting method was found to generate inadequate bonding strength.

브라켓 접착용 글라스 아이어노머 시멘트의 접착강도 및 항우식 효과에 관한 연구 (A STUDY ON THE SHEAR BOND STRENGTH AND THE ANTICARIOGENICITY OF GLASS IONOMER CEMENT FOR BRACKET BONDING)

  • 강용주;김용기
    • 대한소아치과학회지
    • /
    • 제26권3호
    • /
    • pp.538-553
    • /
    • 1999
  • 고정성 교정장치에 의한 법랑질 탈회현상을 예방하기 위하여 교정용 불소 유리 복합 레진과 교정용 글라스 아이어노머 시멘트를 실험군으로 설정하여 각 재료의 법랑질과의 결합 강도와 항우식효과를 측정하여 교정용 글라스 아이어노머 시멘트와 교정용 불소 유리 복합 레진, 일반 교정용 복합 레진을 비교하고자 시행되었다. 교정목적으로 발거한 80개의 상악 소구치를 대상으로 선정하여 이중 전단강도 측정을 위하여 각 군당 10개씩 5군으로, 항우식 실험을 위하여 각 군당 10개씩 3군으로 무작위로 분배하였다. 전단강도 실험을 위하여 I군은 일반 교정용 레진을, II군은 불소 유리 레진을 사용하여 브라켓을 각 치아의 협면에 부착하였으며, III군은 치면 처리를 시행하지 않았고, IV군과 V군은 각각 폴리아크릴릭산과 35% 인산으로 치면처리를 시행한 후 글라스 아이어노머 시멘트를 사용하여 부착하고 만능 시험기를 이용하여 전단 강도를 측정한 후 주사 전자 현미경으로 파절면을 관찰하였다. 항우식 효과 실험을 위하여 전단 강도 실험에서 I, II, III군과 동일한 재료와 방법으로 브라켓을 부착하고 인공 우식을 유발시켜 얻어진 연마 표본을 편광현미경으로 우식 유발 부위를 관찰하였으며 이를 화상분석 프로그램을 사용하여 병소의 깊이를 측정하였다. 본 실험의 결과로 접착강도 실험에서는 글라스 아이어노머 군(III, IV, V)과 레진 군(I, II) 사이에선 글라스 아이어노머 군이 레진 군에 비해 전반적으로 낮은 수치를 보였고, II군과 V군간을 제외하고는 서로 유의한 차이를 보였으며(p<.05) 레진 접착 군간의 비교에서는 I군이 다소 높은 접착강도를 보였으나 유의차는 없었다(p>.05). 글라스 아이어노머 접착 군간의 비교에선 V군이 가장 높고 그 다음 IV군, III군의 순으로 낮아졌으며, III군과 V군간에서만 유의차를 보였다(p<.05). 파절 양상의 관찰 시 I, II군에서는 주로 응집성 파절 양상이, III군에서는 대부분 부착성 파절 양상이 특징적이었으며, IV군과 V군에서는 이상의 파절 양상이 혼합되어 관찰되었다. 평균 우식 병소의 깊이에선 글라스 아이어노머 접착군인 III군이 레진 접착군인 I군, II군에 비해 얕았으며(p<.05), 레진간에서도 역시 불소 유리 레진 접착군인 II군이 I군에 비해 얕았다(p<.05).

  • PDF

Debonding forces of three different customized bases of a lingual bracket system

  • Sung, Jang-Won;Kwon, Tae-Yub;Kyung, Hee-Moon
    • 대한치과교정학회지
    • /
    • 제43권5호
    • /
    • pp.235-241
    • /
    • 2013
  • Objective: The purpose of this study was to investigate whether extension of the custom base is necessary for enhancement of bond strength, by comparing the debonding forces and residual adhesives of 3 different lingual bracket systems. Methods: A total of 42 extracted upper premolars were randomly divided into 3 groups of 14 each for bonding with brackets having (1) a conventional limited resin custom base; (2) an extended gold alloy custom base: Incognito${TM}$; and (3) an extended resin custom base: KommonBase${TM}$. The bonding area was measured by scanning the bracket bases with a 3-dimensional digital scanner. The debonding force was measured with an Instron universal testing machine, which applied an occlusogingival shear force. Results: The mean debonding forces were 60.83 N (standard deviation [SD] 10.12), 69.29 N (SD 9.59), and 104.35 N (SD17.84) for the limited resin custom base, extended gold alloy custom base, and extended resin custom base, respectively. The debonding force observed with the extended resin custom base was significantly different from that observed with the other bases. In addition, the adhesive remnant index was significantly higher with the extended gold alloy custom base. Conclusions: All 3 custom-base lingual brackets can withstand occlusal and orthodontic forces. We conclude that effective bonding of lingual brackets can be obtained without extension of the custom base.

Comparative evaluation of shear bond strength of orthodontic brackets bonded to three-dimensionally-printed and milled materials after surface treatment and artificial aging

  • Ameer Biadsee;Ofir Rosner;Carol Khalil;Vanina Atanasova;Joel Blushtein;Shifra Levartovsky
    • 대한치과교정학회지
    • /
    • 제53권1호
    • /
    • pp.45-53
    • /
    • 2023
  • Objective: This study aimed to evaluate the shear bond strength (SBS) of orthodontic brackets bonded to three-dimensionally (3D)-printed materials after various surface treatments and artificial aging compared with that bonded to computer-aided design/computer-aided manufacturing (CAD-CAM) polymethyl methacrylate (PMMA)-milled materials. Methods: Eighty cylindrical specimens were 3D printed and divided into the following four subgroups (n = 20 each) according to the surface treatment and artificial aging procedure. Group A, sandblasted with 50 ㎛ aluminum oxide particles (SA) and aging; group B, sandblasted with 30 ㎛ silica-coated alumina particles (CO) and aging; group C, SA without aging; and group D, CO without aging. For the control group, 20 CAD-CAM PMMA-milled cylindrical specimens were sandblasted with SA and aged. The SBS was measured using a universal testing machine (0.25 mm/min), examined at ×2.5 magnification for failure mode classification, and statistically analyzed (p = 0.05). Results: The retention obtained with the 3D-printed materials (groups A-D) was higher than that obtained with the PMMA-milled materials (control group). However, no significant difference was found between the study and control groups, except for group C (SA without aging), which showed significantly higher retention than the control group (PMMA-SA and thermocycling) (p = 0.037). Study groups A-D predominantly exhibited a cohesive specimen mode, indicating specimen fracture. Conclusions: Orthodontic brackets bonded to 3D-printed materials exhibit acceptable bonding strengths. However, 3D-printed materials are prone to cohesive failure, which may result in crown fractures.

Nd : YAG 및 Er : YAG 레이저로 치아표면 조사시 브라켓 전단접착강도에 관한 실험적 연구 (ORTHODONTIC BRACKET SHEAR BOND STRENGTH TO Nd:YAG LASER Er:YAG LASER IRRADIATED ENAMEL)

  • 최승훈;양원식
    • 대한치과교정학회지
    • /
    • 제27권1호
    • /
    • pp.141-155
    • /
    • 1997
  • 교정장치의 직접접착으로 인한 프라켓 주위의 탈석회화 개선 및 산부식시 야기되는 법랑질의 목적 부위 이상으로의 산의 유출방지와 시술시 시간소요 개선을 목적으로 레이저를 조사한 치면의주사전자현미경 소견을 관찰하고 브라켓과 치면 사이의 전단접착강도 및 적합한 조사에너지량을 측정, 평가하기 위하여 실험을 시행하였다. 실험재료로 189개의 소구치를 사용하여 산부식 및 Nd:YAG 레이저로 100mj 10pps, 100mj 20pps, 150mj 20pps, 200mj 20pps를, Er:YAG 레이저로 60mj 5pps, 60mj 10pps, 100mj 10pps, 200mj 10pps, 200mj 15pps, 400mj 10pps를 조사한 각 15개 총 165개의 치 아를 교정용 접착제로 접착한후 24시간, 1주, 3주 후로 나누어 전단 접착강도를 측정하였으며, 나머지 24개의 치아에서 산부식군과 각 레이저 조사군 및 정상치아인 비처치대조군을 주사전자현미경으로 관찰하여 다음과 같은 결과를 얻었다. 1. Nd:YAG 레이저 및 Er:YAG 레이저의 각 조사에너지량에 따른 평균 및 표준편차를 얻었다. 2. 같은 에너지 밀도를 조사한 경우 Er:YAG 레이저 조사군의 전단접착강도가 Nd:YAG 레이저 조사군보다 높았다. 3. Nd:YAG 레이저 조사군에서는 150mj 20pps에서, Er:YAG 레이저 조사군에서는 200mj 15pps에서 가장 높은 전단접착강도를 보였다. 4. 전단접착강도 및 주사전자현미경 관찰 결과 브라켓 접착시 Nd:YAG 레이저 조사군에서는 150mj 20pps, Er:YAG 레이저 조사군에서는 60mj 10pps 조사가 적합하다고 인정되었다.

  • PDF

수종의 광중합기를 이용한 교정용 광중합형 글라스 아이오노머 시멘트의 전단 결합 강도에 관한 연구 (A STUDY ON THE SHEAR BOND STRENGTHS OF VISIBLE LIGHT-CURED GLASS IONOMER CEMENT WITH SEVERAL LIGHT-CURING UNITS)

  • 김민수;유승훈;김종수
    • 대한소아치과학회지
    • /
    • 제34권1호
    • /
    • pp.81-90
    • /
    • 2007
  • 본 연구에서는 세 가지 서로 다른 광원(할로겐 램프 :. Elipar Trilight ; 3M ESPE, Seefeld, Germany, Light Emitting Diode (LED) ; Elipar Freelight2 ; 3M ESPE, Seefeld, Germany, 플라즈마 광 : Flipo ; LOKKI, France)을 사용하여 브라켓과 광원사이의 거리에 따른 광중합형 글라스 아이오노머 시멘트(Fuji ORTHO LC : GC, Japan)의 전단 결합 강도를 알아보고자 하였다. 1. 광중합기에 따른 전단 결합 강도는 광중합기로부터 브라켓까지의 거리가 0mm일 때 3가지 광원에 유의할 만한 차이는 보이지 않았고 광중합기로부터 브라켓까지의 거리가 3mm, 6mm일 때, 할로겐 광과 플라즈마 광 사이에는 유의할 만한 차이가 없었으나 LED 광은 유의성 있게 낮은 전단 결합 강도를 나타냈다. 2. 할로겐 광과 플라즈마 광으로 광중합시 거리에 따른 전단 결합 강도에 유의한 차 없었고 LED광을 사용하여 광중합시에는 거리가 증가할수록 전단 결합 강도가 감소하였다. 특히 0mm에서 3mm로 거리가 증가시 유의할 만한 감소를 나타내었다.

  • PDF

브라켓 부착을 위한 변형된 레이저 부식법 (Modified laser etching technique of enamel for bracket bonding)

  • 윤민성;이상민;양병호
    • 대한치과교정학회지
    • /
    • 제40권2호
    • /
    • pp.87-94
    • /
    • 2010
  • 전단결합강도를 강화하기 위해 레이저를 이용한 부식과 산을 이용한 부식의 비교 연구가 많이 진행되어왔다. 본 연구에서는 Er,Cr:YSGG laser와 전통적인 산부식법을 혼합한 방법의 전단결합강도의 변화에 대한 평가를 하고자 한다. 교정적인 목적으로 발치된 64개의 건전한 소구치를 이용하여 16개씩 4개의 군으로 나누었다. 첫 번째 군은 37% 인산을 15초 적용시키는 전통적인 부식 방법을 택하였고, 두 번째 군은 물방울레이저로 1.5 W로 10초간 부식시킨 후 전통적인 산부식 방법을 시행하였다. 세 번째 군은 두 번째 군과 같지만 산부식을 먼저 시행한 후 물방울레이저로 부식시켰다. 네 번째 군은 물방울레이저를 이용하여 1.5 W로 15초간 부식시켰다. 이후 전단결합강도의 측정 및 치아 표면의 특징 관찰, 그리고 접착제잔류지수를 평가하였다. 두 번째, 세 번째 군은 첫 번째, 네 번째 군에 대하여 전단결합강도가 높게 측정되었다. 하지만 두 가지 기법의 복합사용 순서를 달리한 두 번째, 세 번째 군 사이에는 통계적으로 유의한 차이가 나지 않았다. 기존 산부식을 이용한 브라켓 접착법보다 산부식과 Er,Cr:YSGG laser를 복합적으로 사용 시, 향상된 전단결합강도를 얻을 수 있다.