• Title/Summary/Keyword: Bracket bonding

Search Result 99, Processing Time 0.023 seconds

Tooth color changes associated with the bracket bonding and debonding (교정치료 시 브라켓 부착 및 제거에 따른 치아색 변화)

  • Kim, Seok-Pil;Hwang, In-Nam;Cho, Jin-Hyoung;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.36 no.2 s.115
    • /
    • pp.114-124
    • /
    • 2006
  • The purpose of this study was to evaluate the tooth color changes of resin bonding sites and their adjacent sites on orthodontic bracket bonding. Sixty extracted sound premolars were used and the tooth color was recorded according to the CIE $L^*a^*b^*$ color system using a spectrophotometer. The tooth colors of the twenty premolars were measured and compared before bracket bonding and after removal. On a further twenty premolars, the tooth color was measured before and after only primer application. In the change of $L^*$ values, according to the bracket bonding and primer application, the lightness was decreased, and in the change of $a^*\;and\;b^*$ values, the color was changed into a more yellowish color The color differences $({\Delta}E^*)$ were calculated from the $L^*a^*b^*$ values and compared with the standard value of clinical detection $({\Delta}E^*=3.7)$. The color differences between before the bracket bonding and after removal noted exceeded the standard value and those of between before and after the primer application were not larger than the standard value. Toothbrushing was performed after application of the primer to evaluate the color changes according to the primer abrasion. As a control, toothbrushing was performed on the last twenty premolars. The color differences noted were larger than the standard value after toothbrushing. Also, to evaluate the color changes of the tooth which is exposed to sun irradiation after bracket removal, additional photoaging was performed and the color was measured for all teeth. The additional color differences after photoaging were smaller than the standard value. The above results suggest that the tooth color changes after fixed orthodontic treatment.

A COMPARATIVE STUDY OF THE SHEAR BOND STRENGTH OF DIFERENT CERAMIC BRACKETS AND ADHESIVES (세라믹 브라켓과 교정용 접착제에 따른 전단 결합 강도의 비교 연구)

  • Lee, Joo-Won;Yoo, Dong-Hwan;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.27 no.2
    • /
    • pp.315-326
    • /
    • 1997
  • The purpose of this study was to evaluate the shear bond strength of three kinds of different ceramic brackets with three different bonding adhesives. 5 specimens for each combination were tested for shear bond strength using Instron and for fracture site using SENL And 3 specimens were cross-sectioned for SEM examination of bonding pattern between bracket, resin and enamel surface. The results were as follows 1. The shear bond strength of chemical curing adhesives were higher than that of light curing adhesives. 2. The shear bond strength of Starfire bracket, chemical-bonded type, was lower than that of Transcend bracket, mechanical-bonded type, and Fascination bracket, combined type. 3. Fracture site of each bracket and tooth surface was examined under a light optical stereoscopic microscope, Transcend groups were mainly at the E/R intderface. Fascination groups were mainly at the COMB interface and Starfire groups were mainly at the R/B interface.

  • PDF

TENSILE STRENGTH OF ORTHODONTIC DIRECT BONING ADHESIVES (교정용 접착제의 인장강도)

  • Kwon, Oh-Won
    • The korean journal of orthodontics
    • /
    • v.12 no.1
    • /
    • pp.15-20
    • /
    • 1982
  • The requirement of ideal orthodontic direct bonding adhesive should include longevity of bond, ability to withstand a variety of forces, resistance to the degrading effects of the oral environment, and ability to be easily removed without affecting the integrity of the enamel. The purpose of this study was to evaluate the adhesive properties of recently developed 3 orthodontic directbonding adhesives by testing the tensile strength. 75 premolars extracted for orthodontic treatment were used. The tensile strength was tested by Tensilon/UTM-1-10000C after 24 hours from bonding. Following results were obtained; The mean tensile strength of each product was higher than the maximum force $(29kg/cm^2)$ exerted on a bracket during orthodontic treatment. The tensile strength of Mono-Lok was statistically higher than Concise and Dyna-Bond, although there was no difference between the tensile strength of Concise and Dyna-Bond statistically. Of the filure, the combination type of failure $(68\%)$, where part of the adhesive remained on the tooth and part on the bracket was the most common type. The second type of failure $(22.7\%)$ occurred at the toothadhesive interface and the last type of failure $(9.3\%)$ occurred at the adhesive-bracket interface.

  • PDF

Evaluation of Shear Bond Strength of Various Orthodontic Bracket Bonding Agents (수종의 교정용 브라켓 접착 레진의 전단 강도 평가)

  • Youngjun, Ham;Miran, Han
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.49 no.3
    • /
    • pp.264-273
    • /
    • 2022
  • Due to the development of properties of adhesive materials currently used in dentistry, the bonding ability between the brackets and the tooth enamel has been greatly improved. In general, in situations where cooperation can be obtained, adhesion of the orthodontic bracket through the conventional three-step process can show excellent bonding strength. However, if it is difficult to expect patient cooperation, as in the pediatric dentistry area, or if moisture isolation is not properly performed, the binding strength that does not reach the expected effect. As a result, various products that simplify the process for adhesion are being developed. The aim of this study was to evaluate and compare the shear bonding strength between the conventional 3-step adhesion system, self-etching primer system and one-step adhesion system that reduces the priming process. A total of 60 human maxillary, mandibular premolars were prepared. Group I (control group) were followed conventional 3-step bonding process. Group II were conditioned with self-etching primer. Group III were etched with 37% phosphoric acid and brackets were bonded with self-priming adhesive. The resultant shear bond strength of each group was measured and an adhesive remnant index (ARI) was recorded. The mean shear bond strength of group I, II, III were 14.69 MPa, 11.21 MPa and 12.21 MPa respectively. Significant differences could only be found between group I, II and group I, III (p < 0.05). The ARI indicated no significant difference among all groups.

Comparison of bond strengths of ceramic brackets bonded to zirconia surfaces using different zirconia primers and a universal adhesive

  • Lee, Ji-Yeon;Ahn, Jaechan;An, Sang In;Park, Jeong-won
    • Restorative Dentistry and Endodontics
    • /
    • v.43 no.1
    • /
    • pp.7.1-7.7
    • /
    • 2018
  • Objectives: The aim of this study is to compare the shear bond strengths of ceramic brackets bonded to zirconia surfaces using different zirconia primers and universal adhesive. Materials and Methods: Fifty zirconia blocks ($15{\times}15{\times}10mm$, Zpex, Tosoh Corporation) were polished with 1,000 grit sand paper and air-abraded with $50{\mu}m$ $Al_2O_3$ for 10 seconds (40 psi). They were divided into 5 groups: control (CO), Metal/Zirconia primer (MZ, Ivoclar Vivadent), Z-PRIME Plus (ZP, Bisco), Zirconia Liner (ZL, Sun Medical), and Scotchbond Universal adhesive (SU, 3M ESPE). Transbond XT Primer (used for CO, MZ, ZP, and ZL) and Transbond XT Paste was used for bracket bonding (Gemini clear ceramic brackets, 3M Unitek). After 24 hours at $37^{\circ}C$ storage, specimens underwent 2,000 thermocycles, and then, shear bond strengths were measured (1 mm/min). An adhesive remnant index (ARI) score was calculated. The data were analyzed using one-way analysis of variance and the Bonferroni test (p = 0.05). Results: Surface treatment with primers resulted in increased shear bond strength. The SU group showed the highest shear bond strength followed by the ZP, ZL, MZ, and CO groups, in that order. The median ARI scores were as follows: CO = 0, MZ = 0, ZP = 0, ZL = 0, and SU = 3 (p < 0.05). Conclusions: Within this experiment, zirconia primer can increase the shear bond strength of bracket bonding. The highest shear bond strength is observed in SU group, even when no primer is used.

Effect of Different Types of Bonding Agent and Application Methods on Shear Bond Strength of Orthodontic Bracket (Bonding agent의 종류 및 적용 방법에 따른 교정용 브라켓의 전단결합강도에 관한 연구)

  • Lee, Jaehee;Kim, Jongsoo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.4
    • /
    • pp.419-426
    • /
    • 2017
  • Attachment of the orthodontic bracket conducted during the window opening procedure can result in failure due to various adverse conditions such as blood or saliva contamination, or other wet conditions. For the success of the bracket attachment, reduction of total operation time is crucial. The purpose of this literature is to evaluate the differences between the final resultant shear bond strength of the conventional method of using phosphoric acid and self-etching primer, and that of the operation time-reduced method in which the curing step is omitted subsequent to the primer application. A total of 40 human maxillary incisors were prepared. Group I(control group) and II were etched with 37% phosphoric acid and Group III and IV were conditioned with self-etching primer. Attachment of the group I and III was conducted by manufacturer's instructions. The operation time of Group II and IV was reduced by eliminating the curing step after the primer application. The resultant shear bond strength of each group was measured and an adhesive remnant index (ARI) was recorded. The mean shear bond strength of group I, II, III, and IV were 14.16 MPa, 8.33 MPa, 8.29 MPa, and 6.48 MPa respectively. Significant differences could only be found between the control group and the experimental groups (p < 0.05). The ARI indicated no significant difference among all groups.

SHEAR BOND STRENGTH AND FAILURE PATTERNS ACCORDING TO THE MATERIAL OF RESIN BASE IN INDIRECT BRACKET BONDING (브라켓 간접부착시 레진 베이스의 재료에 따른 전단결합강도와 파절양상 비교)

  • Jeon, Man-Bae;Hwang, Hyeon-Shik;Kim, Jong-Chul
    • The korean journal of orthodontics
    • /
    • v.28 no.2 s.67
    • /
    • pp.277-284
    • /
    • 1998
  • The purpose of this study was to evaluate the propriety of making use of the light-cured resin base in indirect bracket bonding technique by study of shear bond strength and failure patterns according to the material of resin base. Metal brackets were bonded to the stone models of specimens involving bovine lower incisor with chemical-cured(Excel), light-cured(Light-Bond) and thermal-cured(Therma-Cure) resin. They were transferred to the specimens and bonded using sealant. The shear bond strength was tested on Instron. After bracket removal, the bracket base was examined and assessed with the adhesive remnant index(ARI). The results were as follows : 1. No significant differences in shear bond strength were found among the three groups (P>0.05). 2. No significant differences in ARI score were found among the three groups (P>0.05). The above results suggest that light-cured resin base in addition to chemical-cured and thermal-cured resin bases is useful in the indirect bonding technique.

  • PDF

A STUDY OF THE SHEAR BOND STRENGTH OF METAL BRACKETS AND CERAMIC BRACKETS AND THE CONDITION AFTER DEBONDING (Metal bracket과 ceramic bracket의 전단 결합 강도와 debonding 상태에 관한 연구)

  • Yoon, Jung-Jin;Ryu, Young-Kyu
    • The korean journal of orthodontics
    • /
    • v.22 no.2 s.37
    • /
    • pp.327-343
    • /
    • 1992
  • Metal brackets and ceramic brackets were bonded to natural teeth, porcelain crowns and gold crowns After stored in artificial saliva solution for 72 hours at $37^{\circ}C$, the shear bond strengths were measured by Instron and compared with them, the bonding sites and bracket bases were examined by scanning electron microscope and light optical stereomicroscope. The results were as follows: 1. The shear bond strengths of the group which metal brackets were bonded to natural teeth and the groups which ceramic brackets were bonded to natural teeth and porcelain crowns were comparable to each other, the shear bond strength of the group which metal brackets were bonded to gold crowns was significantly low. 2. The bond failed predominantly at the bracket base/adhesive interface with the bulk of adhesive remaining on enamel in the group which metal brackets were bonded to natural teeth. 3. The bond failed consistently at the crown/adhesive interface with all of adhesive remaining on the bracket babes in the group which metal brackets were bonded to gold crowns. 4. The bond failed at the enamel or crown/adhesive interface with the bulk of adhesive remaining on the bracket bases in the groups which cramic brackets were bonded to natural teeth and porcelain crowns. 5. The shear bond strengths of the groups which ceramic brackets were bonded to porcelain crowns were not affected by etching time.

  • PDF

Joint Design of Steel-Aluminum Power Steering Cylinder by using FE Analysis with Cohesive Zone Model (Cohesive Zone Model을 이용한 동력조향 유압실린더의 스틸-알루미늄 접착부 설계)

  • Lee, C.J.;Lee, S.K.;Ko, D.C.;Schafer, H.;Lee, J.M.;Kim, B.M.
    • Transactions of Materials Processing
    • /
    • v.18 no.5
    • /
    • pp.385-391
    • /
    • 2009
  • An adhesively bonded power steering cylinder with a steel tube and an aluminum bracket was developed to reduce the weight of steering systems. To achieve the joint strength between the steel tube and of the aluminum bracket, the shape aluminum bracket re-designed by using the FE-analysis. Fracture behavior of the adhesive layer was considered by a cohesive zone model(CZM), which is based on the two-parameter fracture phenomenon with critical stress and fracture toughness. From the result of FE-analysis with CZM, re-designed power steering cylinder satisfied the desired joint strength for axial and torsion modes. And its joint strength was verified by the fracture test in each mode.