Background: The incidence of inadequate bowel preparation before elective colonoscopy in this region has never been studied. Materials and Methods: The authors prospectively described the incidence and factors related to inadequate bowel preparation in Thammasat university hospital. Bowel preparation quality was accessed by using Aronchick scale. Factors associated with inadequate bowel preparation were also recorded. Results: Two hundred patients undergoing elective outpatient colonoscopy were enrolled. Inadequate and fair bowel preparation was documented in 9 and 43%, respectively. Factors associated with inadequate bowel preparation were incomplete cleansing agent ingestion (odds ratio 7.7; 95%CI 1.62-36.64) and patient's unrecognization of vegetable avoidance (odds ratio 3.26; 95%CI 1.14-9.28). Conclusions: Compared with previous reported, inadequate bowel preparation was seen less in our study, however, more patients with fair bowel preparation was documented. Further study aiming at investigating the type and amount of fiber contained in diet before elective colonoscopy should be commenced.
Purpose: The purpose of this study was to evaluate the effects of an educational video program on bowel preparation for a colonoscopy. Methods: The study used a non-equivalent control group and non-synchronized design as a quasi-experimental research involving 101 participants undergoing bowel preparation for a colonoscopy (experimental group 51, control group 50 subjects) at W. university hospital, from Aug. 7 to Oct. 31, 2013. The control group received verbal education with an explanatory note while the experimental group received education using a video program. To measure knowledge of diet restrictions and compliance with ingesting bowel preparation solutions, a questionnaire, based on The Korean Society of Gastrointestinal Endoscopy's Guide (2003), developed by Sam-Sook You, was used after revisions and supplementation was done. To measure bowel cleanness, the 'Aronchick Bowel Preparation Scale' was adopted. Data were analyzed using the SPSS WIN 12.0 program. Results: A higher proportion of the experimental group showed a positive change in knowledge level on diet restrictions (U=1011.50, p =.035) and ingestion of bowel preparation solutions (U=980.50, p =.019), a higher level of compliance with diet restrictions (U=638.50, p <.001), ingesting bowel preparation solutions (U=668.00, p <.001) and the level of bowel cleanness (${\chi}^2$=17.00, p <.001) than the control group. Conclusion: The results of this study indicate that a video educational program for patients having a colonoscopy can improve knowledge, level of compliance with diet restrictions, ingestion of bowel preparation solutions, and bowel cleanness. Therefore video educational program should be used with this patient group.
Journal of Korean Academy of Fundamentals of Nursing
/
v.24
no.1
/
pp.60-71
/
2017
Purpose: The purpose of this study was to develop video assisted education on bowel preparation for colonoscopy (VEBPC) and use a snartphone to evaluate effects of the VEBPC. Methods: Adult patients who were scheduled for colonoscopy were recruited from a university general hospital and randomly assigned to three groups. Group 1 (n=30) watched the video using a computer set in the endoscope consulting room. Group 2 (n=29) watched it using a smartphone, and group 3, the control group (n=29) received education with existing instructions at the reservation-reception desk. Participants were evaluated on knowledge on taking bowel preparation agents and diet, compliance on taking bowel preparation agents and diet, satisfaction with education, and actual level of bowel preparation. Results: Group 1 and 2 showed significantly (p<.001) higher scores for knowledge, compliance, and satisfaction compared to the control group. However, in post-hoc test analyses there were no significant differences in these variables between group 1 and 2. No significant difference was found in the actual level of bowel preparation among the three groups. Conclusion: Findings from this study show that VEBPC using smartphone is a better option than existing educational methods. However, replication studies are necessary to confirm these findings.
Journal of The Korean Radiological Technologist Association
/
v.30
no.1
/
pp.143-147
/
2004
Colon study(Teleflator) is the simplest and most effective method for diagnosing colon disease. However, if bowel preparation is insufficiently done, diseases such as polyps, cancer and inflammatory bowel disease could be mistaken for lesions. As a result
The purpose of this study was to identify the effects of bowel preparation convergence program for colonoscopy. This study used a nonequivalent control group pretest-posttest design. A sample of 75 clients, who were scheduled for colonoscopy, was included. The experimental group was given bowel preparation convergence program including audiovisual education, walking-exercise and telephone counseling. The data were collected using a structured questionnaire and colonoscopy monitoring and were analyzed using SPSS 21.0 program. The experimental group reported significantly higher compliance of taking bowel preparation agents and test satisfaction(p=.002; p=.001), lower test difficulty and test discomfort than those of the control group(p=.002; p=.001). There were significant differences in level of bowel cleansing and test time required except compliance of diet restriction between groups(p<.001; p=.001; p=.108). This findings indicate that bowel preparation convergence program can be an effective nursing intervention for colonoscopy. The convergence intervention for diagnostic test is needed to be developed in clinical practice.
Kang, Min Kyu;Jang, Byung Ik;Park, Jun Suk;Kim, Kyeong Ok
Journal of Yeungnam Medical Science
/
v.36
no.2
/
pp.99-104
/
2019
Background: Because of its efficacy and safety, polyethylene glycol (PEG) is generally used to prepare for colonoscopy. However, the side effects of PEG, including nausea, vomiting, abdominal discomfort, pain, and general weakness, tend to decrease patient compliance and satisfaction. The aim of this study is to investigate the efficacy and safety of PEG with 0.1 mg ramosetron on colonoscopy patients who had difficulty taking PEG due to side effects or large volume. Methods: From January to August in 2012, 28 patients who visited Yeungnam University hospital for a colonoscopy were prospectively enrolled. All enrolled patients were previous history underwent colonoscopy using PEG only in our hospital. The efficacy and safety of ramosetron were assessed through the use of a questionnaire, and compared previous bowel preparation. Results: Compared to previous examination, the patients using the ramosetron reported less nausea, vomiting, abdominal discomfort, and abdominal pain, as well as a higher degree of compliance and satisfaction of the patient. There were no side effects reported with the use of ramosetron. However, overall bowel preparation quality was not better than the previous examination. Conclusion: In case of the use of ramosetron in combination with PEG for bowel preparation, patients experienced a higher rate of compliance and tolerance. Looking forward, ramosetron may become an option of pretreatment for bowel preparation.
Continuous measurement of quality indicators (QIs) should be a routine part of colonoscopy, as a wide variation still exists in the performance and quality levels of colonoscopy in Korea. Among the many QIs of colonoscopy, the adenoma detection rate, average withdrawal time, bowel preparation adequacy, and cecal intubation rate should be monitored in daily clinical practice to improve the quality of the procedure. The adenoma detection rate is the best indicator of the quality of colonoscopy; however, it has many limitations for universal use in daily practice. With the development of natural language processing, the adenoma detection rate is expected to become more effective and useful. It is important that colonoscopists do not strictly and mechanically maintain an average withdrawal time of 6 minutes but instead perform careful colonoscopy to maximally expose the colonic mucosa with a withdrawal time of at least 6 minutes. To achieve adequate bowel preparation, documentation of bowel preparation with the Boston Bowel Preparation Scale (BBPS) should be a routine part of colonoscopy. When colonoscopists routinely followed the bowel preparation protocols, ≥85% of outpatient screening colonoscopies had a BBPS score of ≥6. In addition, the cecal intubation rate should be ≥95% of all screening colonoscopies. The first step in improving colonoscopy quality in Korea is to apply these key performance measurements in clinical practice.
Park, Keum-Mi;Kim, Myung Hee;Hwang, Sun Kyung;Kim, Dong Hee;Kim, Ju Sung
Korean Journal of Adult Nursing
/
v.19
no.2
/
pp.237-247
/
2007
Purpose: This study was a randomized single-blind trial of whole versus split-dose PEG solutions for colonoscopy preparation to compare the patient compliance, quality of bowel cleansing, and endoscopist's satisfaction. Methods: The participants were recruited from outpatients who planned to receive colonoscopy of C hospital in Busan. Sixty participants were randomly assigned to receive either a spit-dose group(n=30) consuming $2{\ell}$ of PEG solution twice, or a whole-dose group(n=30), consuming $4{\ell}$ of PEG solution once. These participants completed the questionnaire to assess their compliance before colonoscopy. The quality of bowel cleansing was assessed using the Ottawa Scale with the endoscopist who was blinded to the type of preparation, and their satisfaction by using VAS. Results: The participants who did not completely consume $4{\ell}$ of PEG solution were less in split-dose than in whole-dose group (0% vs 13.3%). The split-dose group complained less about abdominal pain(t=2.644, p=0.009) and abdominal bloating(t=2.802, p=0.013) with a statistical significance. For the quality of bowel preparation, there were no significant differences in the bowel cleansing scores and the endoscopist's satisfaction between two groups. Conclusion: Colonic preparation with split-dose of PEG solution could be a more useful method for better patient compliance, with no significant impact on bowel cleansing quality.
Lee, Jae Young;Jang, Byung Ik;Nam, Yoon Jeong;Song, Jay;Kim, Min Cheol;Chung, Seung Min;Jang, Jong Geol;Cho, Jae Ho
Journal of Yeungnam Medical Science
/
v.32
no.1
/
pp.55-59
/
2015
The widely used polyethylene glycol (PEG)-based solutions have been proven effective for bowel preparation when 4 L of the solution is administered before colonoscopy. However, large volumes of the solutions are generally poorly tolerated. A new PEG-based solution consisting of 2 L of PEG and a high dose of ascorbic acid has recently become available. Electrolyte abnormalities caused by PEG-based solutions have rarely been reported. We report on a case of acute severe hyponatremia with associated generalized tonic-clonic seizures after bowel preparation with a low-volume PEG plus ascorbic acid solution in a 74-year-old woman with no history of seizures. She took a beta blocker, an angiotensin-converting enzyme inhibitor, and glimepiride for hypertension and diabetes mellitus. She showed general weakness, nausea, agitation, muscle cramping, and seizures after ingestion of the PEG plus ascorbic acid solution. Her serum sodium level was 112 mEq/L. Her symptoms improved after intravenous administration of hypertonic saline. Physicians should pay attention to screening for electrolytes and development of neurological symptoms during bowel preparation.
The purpose of this study was determine the effect of sugar addition or gum chewing on the nausea, disgust, bowel preparation scale of through the subject taking the Coolprep as bowel preparation for colonoscopy. A randomized controledl trial design was used. There were 120 participants in the study, aged 20-65. The data were analyzed using one-way ANOVA and X2 test using SPSS/WIN 25.0. There was no significant difference in nausea, disgust and bowel preparation scale among sugar additions, chewing gum and standard method groups. This study result therefore, convergent efforts are needed to reduce the difficulty of taking. The subjects who participated in the experiment did not have any special side effects such as hyperglycemia, so it is considered to be partially applicable to individual preferences.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.