• Title/Summary/Keyword: Boundary Treatment

Search Result 521, Processing Time 0.027 seconds

A Study on Blasting Method for the Smallest of the Scour Depth after Pier Construction (교각의 세굴심도 최소화를 위한 발파공법 연구)

  • 김가현;김종주;안명석
    • Explosives and Blasting
    • /
    • v.21 no.3
    • /
    • pp.23-35
    • /
    • 2003
  • An analytical diffusion model for flood routing with backwater effects and lateral flows is developed. The basic diffusion equation is linearized about an average depth of (H + h), and is solved using the boundary conditons which take into account the effects of backwater and lateral flows. Scouring phenomenon around pier which affects on the support function of pier and the stabilization if river bed is a complex problem depending on flow properties and river bed state as well as pier geometry. therefore, there is no uniting theory at present which would enable the designer to estimate, with confidence, the depth of scour at bridge piers. The various methods used in erosion control are collectively called upstream engineering, HEC-RAS Model, underwater blasting. They consist of reforestation, check-dam construction, planting of burned-over areas, contour plowing and regulation of crop and grazing practices. Also included are measures for proper treatment of high embankments and cuts and stabilization of streambanks by planting or by revetment construction. One phase of reforestation that may be applied near a reservoir is planting of vegetation screens. Such screens, planted on the flats adjacent to the normal stream channel at the head of a reservoir, reduce the velocity of silt-laden storm inflows that inundate these areas. This stilling action causes extensive deposition to occur before the silt reaches the main cavity of the reservoir.

Preparation and Application of Nanofiltration Membranes (NF막 제조 및 응용공정)

  • 이규호;오남운;제갈종건
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1998.06a
    • /
    • pp.135-153
    • /
    • 1998
  • Nanofiltration (NF) is a recently introduced term in membrane separation. In 1988, Eriksson was one of the first authors using the word 'nanofiltration' explicitly. Some years before, FilmTech started to use this term for their NF50 membrane which was supposed to be a very loose reverse osmosis membrane or a very tight ultrafiltration membrane. Since then, this term has been introduced to indicate a specific boundary of membrane technology in between ultrafiltration and reverse osmosis. The application fields of the NF membranes are very broad as follows: Demeneralizing water, Cleaning up contaminated groundwater, Ultrapure water production, Treatment of effleunts containing heavy metals, Offshore oil platforms, Yeast production, Pulp and paper mills, Textile production, Electroless copper plating, Cheese whey production, Cyclodextrin production, Lactose production. The earliest NF membrane was made by Cadotte et al, using piperazine and trimesoyl chloride as monomers for the formation of polyamide active layer of the composite type membrane. They coated very thin interfacially potymerized polyamide on the surface of the microporous polysulfone supports. The NF membrane exhibited low rejections for monovalent anions (chloride) and high rejections for bivalent anions (sulphate). This membrane was called NS300. Some of the earliest NF membranes, like the NF40 membrane of FilmTech, the NTR7250 of Nitto-Denko and the UTC20 and UTC60 of Toray, are formed by a comparable synthesis route as the NS300 membrane. Commercially available NF membranes nowadays are as follows: ASP35 (Advanced Membrane Technology), MPF21; MPF32 (Kiryat Weizmann), UTC20; UTC60; UTC70; UTC90 (Toray), CTA-LP; TFCS (Fluid Systems), NF45; NF70 (FilmTec), BQ01; MX07; HG01; HG19; SX01; SX10 (Osmonics), 8040-LSY-PVDI (Hydranautics), NF CA30; NF PES 10 (Hoechst), WFN0505 (Stork Friesland). The typical ones among the commercially available NF membranes are polyamide composite membrane consisting of interfacially polymerized polyamide active layer and microporous support. While showing high water fluxes and high rejections of multivalent ions and small organic molecules, these membranes have relatively low chemical stability. These membranes have low chlorine tolerance and are unstable in acid or base solution. This chemical instability is appearing to be a big obstacle for their applications. To improve the chemical stability, we have tried, in this study, to prepare chemically stable NF membranes from PVA. The ionomers and interfacially polymerized polyamide were used for the modification of'the PVA membranes. For the detail study of the active layer, homogeneous NF membranes made only from active layer materials were prepared and for the high performance, composite type NF membranes were prepared by coating the active layer materials on microporous polysulfone supports.

  • PDF

Groundwater Environment of the Okmyong Waste Landfill in the Pohang City (포항 옥명 폐기물 매립지의 지하수 환경)

  • 정상용;이강근
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.5 no.4
    • /
    • pp.223-232
    • /
    • 1998
  • The Okmyong Waste Landfill which is one of major industrial waste landfills in Korea has been used for 10 years since January, 1988. The groundwater in range of 2∼3 km from the landfill is a little acidic and has high concentrations of EC, NO$_3$, and SO$_4$ because of acidic rain in Pohang. The groundwater pattern in Piper's trilinear diagram belongs to Ca-SO$_4$and Na-SO$_4$types, but Ca-SO$_4$type is more predominant. The groundwater of five monitoring wells at the landfill area is a litle alkaline and has high concentrations of TS, COD, Na, Cl, SO$_4$, Alkalinity and F because of the effect of the leachates. They also have high heavy metals of Mn, Zn, Pb, Cr and Ni but toxic organic compounds are not detected. Their groundwater pattern is Na-SO$_4$type and distinguished from the groundwater pattern Na-Cl types of the Nanjido and the Seokdae Municipal Waste Landfills. The range of groundwater contamination which is validated up to now is about 120m west from the entrance of the Okmyong Waste Landfill. To prevent the dispersion of the leachates to the outside, cutoff walls should be constructed at the boundary of the landfill. Several pumping wells should also be developed at the landfill so that the contaminated groundwater can be pumped and treated at a leachate-treatment plant in the landfill.

  • PDF

A Study on the High Frequency Ultrasonic Attenuation Characterization in Artificially Aging Degraded 2.25Cr-1Mo Steel (2.25Cr-1Mo 강 인공 열화재의 고주파수 초음파 감쇠특성에 관한 연구)

  • Park, Ik-Keun;Park, Un-Su;Kim, Chung-Seok;Kim, Hyun-Mook;Kwun, Sook-In;Byeon, Jai-Won
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.4
    • /
    • pp.439-445
    • /
    • 2001
  • The destructive method is reliable and widely used lot the estimation of material degradation but, it have time-consuming and a great difficulty in preparing specimens from in-service industrial facilities. Therefore, the estimation of degraded structural materials used at high temperature by nondestructive evaluation such as electric resistance method, replica method, Barkhausen noise method, electro-chemical method and ultrasonic method are strongly desired. Ultrasonic nondestructive evaluation technique has been reported good to attain efficiency of measurement, high sensitivity of measurement, and rapidity and reliability of result interpretation. In this study, it was verified experimentally the feasibility of the evaluation of degraded 2.25Cr-1Mo steel specimens which were prepared by the isothermal aging heat treatment at $630^{\circ}C$ by high frequency longitudinal wave method investigating the change of attenuation coefficient by FFT analysis and wavelet transform. Because of carbide precipitation increase and spheroidization near grain boundary of microstructure to aging degradation, attenuation coefficient had a tendency to increase as degradation proceeded. It was identified possibly to evaluate degradation using the characteristics of high-frequency ultrasonics. Frequency dependence of ultrasonic attenuation coefficient to aging degradation appeared large, which made sure that attenuation coefficient is an important parameter for evaluation of aging degradation.

  • PDF

Ferroelectric domain inversion in $LiNbO_3$ crystal plate during heat treatment for Ti in-diffusion ($Ti:LiNbO_3$ 도파로 제작을 위한 열처리 과정 동안 강유전 도메인 특성에 미치는 영향)

  • Yang, W.S.;Lee, H.Y.;Kwon, S.W.;Kim, W.K.;Lee, H.Y.;Yoon, D.H.
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.15 no.3
    • /
    • pp.124-127
    • /
    • 2005
  • It is demonstrated that the annealing process for Ti in-diffusion to z-cut $LiNbO_3$ at temperature lower than the curie temperature in a platinum (Pt) box can cause a ferroelectric micro-domain inversion at the +z surface and Li out-diffusion, therefore which should be avoided or suppressed for waveguide type periodically poled lithium niobate (PPLN) devices. The depth of the inversion layer depends on the Ti-diffusion conditions such as temperature, atmosphere, the sealing method of $LiNbO_3$ in the Pt box and crystal orientation is experimentally examined. The result shows that the polarization-inverted domain boundary appears at the only +z surface and its thickness is about $1.6{\mu}m$. Also, for the etched $LiNbO_3$, surface the domain shape was observed by the optical microscope and atomic force microscopy (AEM), and distribution of the cation concentrations in the $LiNbO_3$ crystal by the secondary ion mass spectrometry (SIMS).

A Study on Images of the Pulse Diagnosis (맥진(脈診)에 관한 도상(圖像)연구)

  • Han, Bong-Jae
    • Korean Journal of Oriental Medicine
    • /
    • v.15 no.2
    • /
    • pp.101-109
    • /
    • 2009
  • The Pulse diagnosis is in the boundary of the Four Examinations, and it is called 切診, or palpation. It has a great impact on people in reminding of the Traditional Medicine that it is probably the first thing that people think of when they hear about Traditional Medicine. Hu-Jun quoted in the Treasured Mirror of Eastern Medicine "東醫寶鑑" that the doctor finds out the deficiency and the excess of the meridian of the patiant through the pulse, and that it is of the utmost necessity to know the "deficiency and the excess" of the meridian to decide the formula (君臣佐使) of the herbal medicine and the acupuncture/moxibustion treatment. The research on the studies of pulse diagnosis have been concentrated on the origin, history, and the theory of the pulse diagnosis throughout the years; however, the number of research on the image from the classics on pulse diagnosis have been less. With this in mind, this paper was written to study more on the origin and the history of the pulse diagnosis as well as to study on the image of pulse diagnosis shown on the classics on Traditional Medicine in China and Korea. The history of the pulse diagnosis has its root on the attempt to find out what is happening inside the body through the indication of the small changes of the pulse that is shown on the outer boundaries of the body. There were various kinds of pulse diagnosis including "Three positions and nine indicators method" and "Carotid pulsation and wrist pulse method" in the ancient period, and wrist pulse-taking method became the most popular since the completion of studying on palpation by 初보. The image of the palpation helps the rudimentary practitioners of Traditional Medicine. They are divided into two large categories, which are the area of diagnosis and the shape of the pulse itself. The historical classics including the image of the pulse diagnosis can be found since the Song Dynasty of China. There are various kinds of image of pulse diagnosis in the classic such as "The picture of the hand meridian" from "脈訣指掌病式圖說", "The picture of the image of meridian" from "察病指南", "The picture of the Seven exterior and Eight interior" from "校正圖注脈訣", and "The picture of the six parts of meridian" from Treasured Mirror of Eastern Medicine "東醫寶鑑". The Treasured Mirror of Eastern Medicine "東醫寶鑑" have analyzed the basic theories and made up the standards of pulse diagnosis by establishing "The picture of the six parts of meridian" based on "The method of placing the viscera and bowels corresponding to cun-guan-qi, or the meridian".

  • PDF

Flow Analyses of Upper Airway Before and After Maxillomandibular Advancement Surgery for Obstructive Sleep Apnea Patient (폐쇄성 수면무호흡증 환자의 상하악 전진술 후 상기도 내 유동해석)

  • Kim, Hyoung-Ho;Suh, Sang-Ho;Choi, Jin-Young;Kim, Taeyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.5
    • /
    • pp.443-448
    • /
    • 2015
  • Obstructive sleep apnea (OSA) is a syndrome characterized by the repetitive episodic collapse of the upper airway. Maxillomandibular advancement surgery is one of the most effective surgical treatment methods in treating obstructive sleep apnea. The advancement of both maxill and mandible can enlarge the cross-sectional areas and volumes of the postero-superior airway. The purpose of this study is to analyze flow patterns in the upper airway before and after maxillomandibular advancement surgery. Here, we analyzed flow phenomena of inspiration and expiration to prevent obstructive sleep apnea patient from happening side effect. Modeling of the upper airway carried out from clinical CT scanned images. We used time-dependent values for boundary condition. CFD analyses were performed and evaluated section of minimum area (SMA), compared with patient inside upper airway before and after maxillomandibular advancement surgery in SMA, and negative pressure effects. The study showed the greatest enlargment of the section of minimum cross-sectional area. Moreover, the velocity and the negative airway pressure were decreased. According to the result of this study, the maxillomandibular advancement surgery stabilizes the airflow in the postero-superior airway of OSA patients.

Degradation Evaluation of 1Cr-0.5Mo Steel using Barkhausen Noise (바크하우젠 노이즈에 의한 1Cr-0.5Mo 강의 열화도 평가)

  • Kim, Min-Gi;Park, Jong-Seo;Lee, Yun-Hee;Kim, Cheol-Gi;Ryu, Kwon-Sang
    • Journal of the Korean Magnetics Society
    • /
    • v.21 no.4
    • /
    • pp.136-140
    • /
    • 2011
  • Mechanical properties of degraded materials must be measured for evaluating the integrity of the facilities operating at high temperature. In fact it is complicated to obtain the different degraded specimens from an operating facility. Specimens of 1Cr-0.5Mo steel prepared by the isothermal heat treatment at $700^{\circ}C$ were tested, which has been widely used as tubes for heat exchangers and as plates for pressure vessels. The magnetic properties and Rockwell hardness (HRB) were measured at room temperature. The peak interval of Barkhausen noise envelope (PIBNE), coercivity, and hardness decreased with the increase of degradation. The magnetic and mechanical softening of matrix is likely to govern the properties of the specimen more than the hardening of grain boundary by carbide precipitations. The degradation of test material may be determined by the linear correlation of PIBNE and HRB. Degradation of 1Cr-0.5Mo steel could well be nondestructively evaluated by PIBNE measured with surface type probe.

Blood Flow Simulation in Bifurcated Geometry of Abdominal and Iliac Arteries Based on CT Images (CT영상에 기반한 복부대동맥과 장골동맥 분기관 모델의 혈류유동 해석)

  • Hong Y. S.;Kim M. C.;Kang H. M.;Lee C. S.;Kim C. J.;Lee J. M.;Kim D. S.;Lee K.
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.497-503
    • /
    • 2004
  • Numerical simulation of blood flow has been conducted based on real vessel geometries generated front DICOM medical images of abdominal and iliac bifurcated arteries of a healthy man. A program was developed to read cross sectional images of the three dimensional arteries and smoothly extract boundary coordinates of vessels. Commercial programs were employed for mesh generation and flow simulation. Pressures, velocities, and flow distributions were found to lie within normal physiological ranges. Peak velocity measured in the iliac artery by ultrasound was 20% smaller than that obtained by simulation. The trend of velocity variation in a cardiac cycle was fairly similar between the simulation and the ultrasonic measurements. Simulation based on real vessel geometry of individual patient provides information on pressure, velocity, and its distribution in the diseased arteries or arteries to be surgically treated. The results of simulation may help surgeons to better understand hemodynamic status and surgical need of the patient by revealing variation of the hemodynamic parameters. Futhermore, they may serve as basic data for surgical treatment of arteries. This research is expected to develop to a program in the future that early diagnose atherosclerosis by showing distribution of a hemodynamic index closely related to atherosclerosis in arteries.

Classification of Ground Subsidence Factors for Prediction of Ground Subsidence Risk (GSR) (굴착공사 중 지반함몰 위험예측을 위한 지반함몰인자 분류)

  • Park, Jin Young;Jang, Eugene;Kim, Hak Joon;Ihm, Myeong Hyeok
    • The Journal of Engineering Geology
    • /
    • v.27 no.2
    • /
    • pp.153-164
    • /
    • 2017
  • The geological factors for causing ground subsidence are very diverse. It can be affected by any geological or extrinsic influences, and even within the same geological factor, the soil depression impact factor can be determined by different physical properties. As a result of reviewing a large number of papers and case histories, it can be seen that there are seven categories of ground subsidence factors. The depth and thickness of the overburden can affect the subsidence depending on the existence of the cavity, whereas the depth and orientation of the boundary between soil and rock are dominant factors in the ground composed of soil and rock. In case of soil layers, more various influencing factors exist such as type of soil, shear strength, relative density and degree of compaction, dry unit weight, water content, and liquid limit. The type of rock, distance from the main fracture and RQD can be influential factors in the bedrock. When approaching from the hydrogeological point of view, the rainfall intensity, the distance and the depth from the main channel, the coefficient of permeability and fluctuation of ground water level can influence to ground subsidence. It is also possible that the ground subsidence can be affected by external factors such as the depth of excavation and distance from the earth retaining wall, groundwater treatment methods at excavation work, and existence of artificial facilities such as sewer pipes. It is estimated that to evaluate the ground subsidence factor during the construction of underground structures in urban areas will be essential. It is expected that ground subsidence factors examined in this study will contribute for the reliable evaluation of the ground subsidence risk.