• 제목/요약/키워드: Boron rejection

검색결과 11건 처리시간 0.031초

Boron removal from model water by RO and NF membranes characterized using S-K model

  • Kheriji, Jamel;Tabassi, Dorra;Bejaoui, Imen;Hamrouni, Bechir
    • Membrane and Water Treatment
    • /
    • 제7권3호
    • /
    • pp.193-207
    • /
    • 2016
  • Boron is one of the most problematic inorganic pollutants and is difficult to remove in water. Strict standards have been imposed for boron content in water because of their high toxicity at high concentrations. Technologies using membrane processes such as reverse osmosis (RO) and nanofiltration (NF) have increasingly been employed in many industrial sectors. In this work, removal of boron from model water solutions was investigated using polyamide reverse osmosis and nanofiltration membranes. RO-AG, RO-SG, NF-90 and NF-HL membranes were used to reduce the boron from model water at different operational conditions. To understand the boron separation properties a characterization of the four membranes was performed by determining the pure water permeability, surface charge and molecular weight cut-off. Thereafter, the effect of feed pressure, concentration, ionic strength, nature of ions in solution and pH on the rejection of boron were studied. The rejection of boron can reach up to 90% for the three membranes AG, SG and NF-90 at pH = 11. The Spiegler-Kedem model was applied to experimental results to determine the reflection coefficient of the membrane ${\sigma}$ and the solute permeability $P_s$.

막 분리 공정을 이용한 1차 계통 실리카 제거에 관한 연구 (A Study on the Silica Removal in Primary System using the Membrane Process)

  • 김봉진;이상진;양호연;김경덕;정희철;조항래
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2005년도 춘계 학술대회
    • /
    • pp.137-144
    • /
    • 2005
  • 원전 1차 계통내에 실리카는 알카리 토금속(Ca, Mg, Al 등)과 결합하여 원전 연료 피복재에 열전달을 방해하는 규석층(Zeolite)를 형성한다. 이렇게 형성된 규석층은 원전 피복재 손상의 원인이 된다. 이러한 원전 1차 계통내 실리카의 문제점들은 EPRI 보고서 등에 그 문제점이 꾸준히 제기되어 왔으며 이러한 문제점들을 해결하기 위하여 막분리 공정을 이용하고자 하였다. 먼저 실험실 규모의 실험을 통해 NF막의 실리카 제거율이 약 $60\;{\sim}\;70\%$, Boron 제거율이 약 $10\;{\sim}\;20\%$로 그 적용 가능성을 확인하였으며, FilmTec과 Osmonics 사 NF막 제품 4종에 대하여 현장 실험을 수행하였다. 현장 사용후연료 저장 붕산수 400L를 시료로 한 실험에서 운전압력 $10kg_{f}/cm^2$에서 FilmTec 사의 NF90-2540이 실리카 제거율이 약 $98\%$, Boron 제거율이 약 $43\%$로 확인되었으며 또한 NF270-2540이 실리카 제거율이 약 $38\%$, Boron 제거율이 약 $3.5\%$로 확인되었다. 이를 바탕으로 장기운전 특성 실험 등의 추가적인 연구를 통해 최적의 실리카 제거를 위한 막 분리공정을 설계 할 예정이다.

  • PDF

표면개질을 이용하여 붕소 제거율이 향상된 역삼투막의 제조 (Fabrication of Reverse Osmosis Membrane with Enhanced Boron Rejection Using Surface Modification)

  • 이덕로;김종학;권세이;이혜진;김인철
    • 멤브레인
    • /
    • 제28권2호
    • /
    • pp.96-104
    • /
    • 2018
  • 해수담수화의 빠른 증가와 함께 붕소 제거에 대한 중요성이 상승하고 있다. 본 연구는 표면개질 시 친수성 화합물을 이용하여 수투과량을 최대한 막고 붕소 제거율을 높이기 위한 연구를 진행하였다. 첫째로, Control polyamide 역삼투막을 얻기 위해 M-phenylenediamine (MPD)와 trimesoyl chloride (TMC)를 Polysulfone 한외여과막에 계면중합을 시켜 polyamide 활성층을 제조하였다. 다음으로, Control polyamide 역삼투막에 표면개질을 진행시켜 D-gluconic acid (DGCA)와 D-gluconic acid sodium salt (DGCA-Na)를 glutaraldehyde (GA)와 hydrochloric acid (HCl)을 이용하여 합성시켰다. 합성된 역삼투막의 표면 분석을 위해 XPS 분석을 진행하였으며, DGCA 및 DGCA-Na 화합물과의 반응이 되었음을 확인하였다. 또한, morphology 측정을 위해 FE-SEM과 AFM 분석을 진행하였으며, polyamide 활성층 형성 및 표면 거칠기를 확인할 수 있었다. 수투과량의 경우, 표면개질을 진행한 역삼투막은 10 GFD 수준이거나 그 이하의 값을 가졌다. 하지만, DGCA 및 DGCA-Na 화합물과 표면개질을 진행한 역삼투막의 붕소 제거율은 94.38, 94.64%로, Control polyamide 역삼투막보다 각각 12.03, 12.29 %p만큼 큰 값을 가지는 것을 확인할 수 있었다.

RO막을 이용한 매립지 침출수 처리 및 붕소 제거 (Landfill Leachate Treatment and Boron Removal by Reverse Osmosis)

  • 정수정;나숙현;배상옥;임병진
    • 한국물환경학회지
    • /
    • 제28권5호
    • /
    • pp.657-662
    • /
    • 2012
  • This study was carried out to evaluate the removal rate of organic and inorganic matters from landfill leachate using pre-treatment process as coagulation and limonite adsorption, and membrane process as RO (reverse osmosis) and NF(nanofiltration). By adding limonite adsorption as pre-treatment process, about 40% of organic matters in leachate was removed through pre-treatment process and 74.7% of boron was removed after RO process without pH adjustment. The rejection rate of boron in RO process mainly depends on the pH and increased at pH value of 10. RO process was performed as two stage system adjusting pH condtion to 7 and 10 in second RO stage for boron removal. Most (>90%) of TOC, Cl- and inorganic matters as Ca was rejected in first RO stage, the residue was rejected in second RO and the rejection rate was above 97%. Considering economic efficiency of operation cost, NF substituted for the first RO and total removal rate of TOC was above 90%. Through RO system toxicity to Daphnia in leachate was removed completely.

Chemical cleaning effects on properties and separation efficiency of an RO membrane

  • Tu, Kha L.;Chivas, Allan R.;Nghiem, Long D.
    • Membrane and Water Treatment
    • /
    • 제6권2호
    • /
    • pp.141-160
    • /
    • 2015
  • This study aims to investigate the impacts of chemical cleaning on the performance of a reverse osmosis membrane. Chemicals used for simulating membrane cleaning include a surfactant (sodium dodecyl sulfate, SDS), a chelating agent (ethylenediaminetetraacetic acid, EDTA), and two proprietary cleaning formulations namely MC3 and MC11. The impact of sequential exposure to multiple membrane cleaning solutions was also examined. Water permeability and the rejection of boron and sodium were investigated under various water fluxes, temperatures and feedwater pH. Changes in the membrane performance were systematically explained based on the changes in the charge density, hydrophobicity and chemical structure of the membrane surface. The experimental results show that membrane cleaning can significantly alter the hydrophobicity and water permeability of the membrane; however, its impacts on the rejections of boron and sodium are marginal. Although the presence of surfactant or chelating agent may cause decreases in the rejection, solution pH is the key factor responsible for the loss of membrane separation and changes in the surface properties. The impact of solution pH on the water permeability can be reversed by applying a subsequent cleaning with the opposite pH condition. Nevertheless, the impacts of solution pH on boron and sodium rejections are irreversible in most cases.

FO와 RO의 붕소 제거 비교를 통한 FO의 안정성 평가 (Safety Evaluation of FO through Comparison of Boron Removal in Forward Osmosis(FO) and Reverse Osmosis(RO))

  • 김창우;이상엽;홍승관
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2010년도 정기 학술발표대회
    • /
    • pp.101.2-101.2
    • /
    • 2010
  • 현재 forward osmosis(FO)에 대한 관심이 증가하고 있다. 하지만 FO에 대한 안정성 평가는 전무한 실정이다. 본 연구는 많은 연구로 안정성을 인정받고 있는 RO와 직접 비교를 통하여 FO의 붕소에 대한 안정성을 평가하였다.

  • PDF

PVDF/h-BN hybrid membranes and their application in desalination through AGMD

  • Moradi, Rasoul;Shariaty-Niassar, Mojtaba;Pourkhalili, Nazila;Mehrizadeh, Masoud;Niknafs, Hassan
    • Membrane and Water Treatment
    • /
    • 제9권4호
    • /
    • pp.221-231
    • /
    • 2018
  • A new procedure to produce poly(vinylidene fluoride)/boron nitride hybrid membrane is presented for application in membrane distillation (MD) process. The influence of hexagonal boron nitride (h-BN) incorporation on the performance of the polymeric membranes is studied through the present investigation. For this aim, h-BN nanopowders were successfully synthesized using the simple chemical vapor deposition (CVD) route and subsequent solvent treatments. The resulting h-BN nanosheets were blended with poly(vinylidene fluoride) (PVDF) solution. Then, the prepared composite solution was subjected to phase inversion process to obtain PVDF/h-BN hybrid membranes. Various examinations such as scanning electron microscopy (SEM), wettability, permeation flux, mechanical strength and liquid entry pressure (LEP) measurements are performed to evaluate the prepared membrane. Moreover, Air gap membrane distillation (AGMD) experiments were carried out to investigate the salt rejection performance and the durability of membranes. The results show that our hybrid PVDF/h-BN membrane presents higher water permeation flux (${\sim}18kg/m^2h$) compared to pristine PVDF membrane. In addition, the experimental data confirms that the prepared nanocomposite membrane is hydrophobic (water contact angle: ${\sim}103^{\circ}$), has a porous skin layer (>85%), as well competitive fouling resistance and operational durability. Furthermore, the total salt rejection efficiency was obtained for PVDF/h-BN membrane. The results prove that the novel PVDF/h-BN membrane can be easily synthesized and applied in MD process for salt rejection purposes.

역삼투압막 해수담수화 장치의 미네럴 분리 성능평가 (Efficiency Estimation for Desalination System of Seawater Using Reverse Osmosis Membrane)

  • 문덕수;정동호;김현주;신필권
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제8권2호
    • /
    • pp.60-66
    • /
    • 2005
  • 삼투압보다 높은 외부압력을 역으로 걸어주면 용매는 용질 농도가 낮은 용액쪽으로 이동하게 되는데 이 현상을 역삼투라고 한다. 역삼투 원리를 이용하여 40-70 기압의 압력구배를 구동력으로 해서 해양심층수의 담수화 적용성을 검토 조사하였다. 역삼투막의 성능에 영향을 미치는 유량과 염제거율에 관한 온도와 압력등 여러 인자들에 관하여 고찰하였다. 온도는 역삼투압 분리막의 유량에 비례하는 반면, 염제거율에 반비례하는 관계를 보이고 있다. 압력은 분리막의 유량과 염제거율에 비례하는 관계를 보였다. $Mg^{2+},\;Ca^{+2},\;Na^+,\;K^+$ 등과 같은 해수의 주성분 미네랄에 대한 역삼투 분리막의 분리특성은 해수와 같은 강전해질 용액에서 전하량이 큰 $Mg^{2+}$$Ca^{2+}$의 염제거율은 99% 이상으로 온도에 비례하는 관계를 보였다. 전하량이 적은 $Na^+$의 염제거율은 98%-99.5%로 2가 이온의 염제거율보다는 낮고, 전하량이 작은 $K^+$ 이온보다는 크게 나타났다. 약산이나 상온에서 기체상태나 유리상태로 존재하는 보론의 배제율은 역삼투 분리 막에서 상당히 낮게 나타나고 대부분 우리나라 먹는물의 수질 기준치를 상회한다. 그러나 보론의 배제율은 온도에 반비례하고 압력에 비례하는 관계를 이용하여 수온 $5^{\circ}C$, 압력 $70kgf/cm^2$의 운전조건에서 생산된 생산수의 보론 농도는 우리나라의 먹는물 수질 기준을 만족한다.

  • PDF

UF-SWRO 혼합공정을 이용한 해수담수화 파일럿 플랜트에서의 해수와 기수의 블렌딩을 통한 보론 및 휴믹산 제거 특성 (Removal Characteristics of Boron and Humic Acid by Pre-blending Seawater and Brackish Water Using UF-SWRO Hybrid Process in Pilot-scale Plant for Desalination)

  • 김원규;신성훈;이학수;우달식
    • 대한환경공학회지
    • /
    • 제38권1호
    • /
    • pp.34-41
    • /
    • 2016
  • UF (ultrafiltration)-SWRO (seawater reverse osmosis) 공정을 이용하여 해수와 기수의 유입수 블렌딩(pre-blending)이 보론(boron)과 휴믹산(humic acid)의 제거에 미치는 영향을 조사하였다. 유입수 블렌딩은 TDS (total dissolved solids) 농도를 기준으로 15,000 mg/L~27,000 mg/L까지 설정하였으며, RO에서의 보론 제거특성을 분석하였다. 또한, 동일한 TDS 농도범위에서 휴믹산을 주입하여 유기물 제거 특성을 알아보았다. 보론은 TDS 농도가 높아질수록 제거율은 76.60% - 83.27%로 높게 나타났지만, 최종 생산된 생산수의 보론 농도는 0.48 mg/L-0.69 mg/L로 높아져 유입수 내 보론 농도가 다량 유입될 시 유입수 블렌딩이 필요할 것으로 판단된다. 휴믹산의 경우 10 mg/L 수준일 경우 TDS 농도 22,500 mg/L가 27,000 mg/L 보다 제거율이 높게 나타났지만, 휴믹산이 5 mg/L 수준일 경우 TDS 농도 18,000 mg/L가 15,000 mg/L보다 높게 나타났다. 한편, 휴믹산이 주입되었을 때 UF-SWRO 공정에서는 오히려 플럭스(flux)와 회수율(recovery rate)이 증가하는 효과를 나타내었는데, 이는 파울링 물질이 $Ca^{2+}$와 휴믹산의 결합에 의해 대부분 제거되어 나타난 것으로 판단된다. 따라서 UF-SWRO를 이용한 해수 담수화 시 보론 농도와 휴믹산 제거측면에서 TDS 농도가 낮을수록 유리하다고 판단된다.

해수담수화플랜트에서 가스 하이드레이트 공정 도입을 통한 역삼투 공정의 에너지 절감 효과 (Effect of gas hydrate process on energy saving for reverse osmosis process in seawater desalination plant)

  • 김수한;임준혁
    • 상하수도학회지
    • /
    • 제27권6호
    • /
    • pp.771-778
    • /
    • 2013
  • Gas hydrate (GH) process is a new desalination technology, where GH is a non- stoichiometric crystalline inclusion compounds formed by water and a number of gas molecules. Seawater GH is produced in a low temperature and a high pressure condition and they are separated from the concentrated seawater. The drawback of the GH process so far is that salt contents contained in its product does not meet the fresh water quality standard. This means that the GH process is not a standalone process for seawater desalination and it needs the help of other desalting process like reverse osmosis (RO). The objective of this study is to investigate the effect of GH process on energy saving for RO process in seawater desalination. The GH product water quality data, which were obtained from a literature, were used as input data for RO process simulation. The simulation results show that the energy saving effect by the GH process is in a range of 68 % to 81 %, which increases as the salt removal efficiency of the GH process increases. Boron (B) and total dissolved solids (TDS) concentrations of the final product of the hybrid process of GH and RO were also investigated through the RO process simulation to find relavant salt rejection efficiency of the GH process. In conclusion, the salt rejection efficiency of the GH process should exceed at least 78% in order to meet the product water quality standards and to increase the energy saving effect.