• Title/Summary/Keyword: Border Tracing

Search Result 13, Processing Time 0.025 seconds

Complete denture rehabilitation of edentulous patient with severe alveolar bone resorption and condyle fracture using gothic arch tracing and closed mouth impression technique: A case report (하악 과두 골절과 심한 잔존치조제 흡수를 보이는 완전 무치악 환자에서 폐구 인상법과 고딕아치 묘기법을 이용한 총의치 수복 증례)

  • Choi, In-Ho;Kim, Seong-A;Kim, Na-Hong;Lee, Yong-Sang
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.2
    • /
    • pp.145-152
    • /
    • 2020
  • It is essential to record maxillomandibular relationship accurately for the harmony of esthetic and function in complete denture. Gothic arch tracing visually demonstrates the movement of the mandible, and is useful to establish accurate and reproducible centric relation. Proper retention and stability of complete denture in patients with severe alveolar bone resorption is difficult to attain. In such case, the closed mouth impression technique might be recommended. The denture border and impression are determined by patient's physiologic movement in the closed mouth impression technique. And, denture peripheral border is entirely closed with oral mucous membrane. This report presents satisfactory complete denture restoration using closed mouth impression technique and gothic arch tracing in patients with mandibular condyle fracture and severe absorption of mandibular alveolar ridge.

Projections from the Prefrontal Cortex to the Dorsal Raphe Nucleus of the Rat

  • Lee, Hyun S.;Kim, Myung-A
    • Animal cells and systems
    • /
    • v.6 no.2
    • /
    • pp.159-165
    • /
    • 2002
  • Projections from the prefrontal cortex to subdivisions of the dorsal raphe nucleus were investigated in the rat using retrograde and anterograde tracing methods. A retrograde tracer, gold-conjugated horseradish peroxidase (WGA-apo-HRP-gold), was injected into each subdivision of the dorsal raphe including lateral wing, dorsomedial, and ventromedial areas. The majority of retrogradely labeled cells were located in the prelimbic, infralim-bic, and dorsal peduncular areas of the medial prefrontal cortex. A few cells were also identified in the cingulate, various regions of the orbital, and agranular insular cortices. Secondly, an anterograde tracer, Phaseolus vulgaris leucoagglutinin (PHA-L), was injected into the medial prefrontal cortex involving the prelimbic or infralimbic areas. Axonal fibers with varicosities were identified in all subdivisions of the DR including the lateral wing, dorsomedial, and ventromedial areas. Projections were bilateral, with ipsilateral predominance. Axonal fibers were observed at the lateral border of medial longitudinal fasciculus or in the interfascicular region at the midline. The present findings demonstrate that both the midline and lateral wing regions of the dorsal raphe nucleus receive excitatory input from cognitive and emotional centers of the cerebral cortex.

A STUDY ON THE DESIGN OF SIMPLE RECORDING DEVICE TO TRACE THE MANDIBULAR MOVEMENTS (하악골운동 추적을 위한 단순기록장치 고안에 관한 연구)

  • Kim, Sang-Soo;Yoon, Chang-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.25 no.1
    • /
    • pp.253-267
    • /
    • 1987
  • The purpose of this study was to improve limitations and disadvantages of the mechanical pantograph and the Visi-Trainer, and to design the reliable and reproducible device mandibular movement tracking device (MMTD) that is more simple, convenient and save the chair time than the mechanical pantograph and Visi-Trainer. MMTD was consist of head frame, horizontal bar, condylar path tracking stylus holders, anterior path tracking stylus holder, two condylar path plastic recording plates, one anterior path plastic recording plate, toggles and open occlusal clutch. To prove the reliability and reproducibility of MMTD, a five adults were selected and mandibular condylar movement was recorded one time by the mechanical pantographic tracing and MMTD. The border movement recording of the mandibular incisor (frontal, sagittal and horizontal) was also recorded by Visi-Trainer and the MMTD. The obtained results were as follows; 1. The condylar movement path (sagittal, horizontal) of the MMTD was not coincidence with that of mechanical pantograph. 2. Measurements of the angulation which established between working and balancing path records by use of the mechanical pantograph and MMTD, there was no significance. 3. In a view of MMTD's reproducibility, there was revealed almost similar recording pattern. 4. The border movement recording of the mandibular incisor by the MMTD and the Visi-Trainer showed almost same reliability and reproducibility. 5. The subjects were able to his original mandibular movements by use of open occlusal clutch in the MMTD.

  • PDF

Web Camera Based Quality Inspection System of Golf Balls (웹캠을 이용한 골프공 품질 검사 시스템)

  • Kwon, Ki-hyeon;Lee, Hyun-Jung
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2016.07a
    • /
    • pp.199-200
    • /
    • 2016
  • 스포츠 산업 응용 분야에서 공의 실시간 품질검사는 산업 생산성과 경쟁력 견지에서 중요한 이슈이다. 컴퓨터 비전 기반 자동 품질검사는 이 문제를 해결하는 하나의 방법이다. 머신 비전 시스템은 품질관리 및 산업프로세스의 실시간 피드백을 주어, 물리적인 제한과 사람의 주관적인 판단을 극복할 수 있다. 컴퓨터비전 기반 시스템에서 디지털카메라에서 취득되는 디지털이미지는 주로 24-비트 컬러이미지이다. 이처럼 많은 레벨을 가지는 이미지분석은 복잡한 이미지 처리기법을 필요로 한다. 그러나 실시간 애플리케이션에서, 한 부분은 실시간으로 검사되어져야 한다. 이 논문에서는 최적의 임계값을 사용하여 스포츠산업계의 산업요구 사항을 만족하는 골프공 품질검사 시스템을 개발하였다.

  • PDF

Developement of a System for Glass Thickness Measurement (비접촉 유리 두께 측정 장치 개발)

  • Park, Jae-Beom;Lee, Eung-Suk;Lee, Min-Ki;Lee, Jong-Gun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.5
    • /
    • pp.529-535
    • /
    • 2009
  • This paper describes a measuring device of glass thickness using machine vision and image processing techniques on real-time. Today, the machine vision enable to inspect fast and exactly than human's eyes. The presented system has advantages of continuous measurement, flexibility and good accuracy. The system consists of a laser diode, a CCD camera with PC. The camera located on the opposite side of the incident beam measures the distance between two reflected laser beams from the glass top and bottom surface. We apply a binary algorithm to convert and analyze the image from camera to PC. Laser point coordination by border tracing algorithm is used to find the center of beam circle. The measured result was compared with micrometer and showed 0.002mm accuracy. Finally, the errors were discussed how to minimize the influence of glass wedge angle and angular error of moving stage.

Analysis of Anatomical Relationship between Stensen's Duct and Buccal Branch of Facial Nerve (이하선관과 안면신경의 협근지 사이의 해부학적 관계 분석)

  • Son, Eun Taik;Choi, Hwan Jun;Nam, Doo Hyun;Kim, Jun Hyuk;Lee, Young Man
    • Archives of Craniofacial Surgery
    • /
    • v.14 no.2
    • /
    • pp.102-106
    • /
    • 2013
  • Background: When using the anterior approach for performing superficial parotidectomy, the first thing to do is to find the buccal branch of the facial nerve and the parotid duct. The buccal branch usually runs transversely with the parotid duct from the anterior border of the parotid gland. We wanted to check the relationship between the two structures during the operation and to get clinically helpful information. Methods: Twelve patients with parotid mass were treated with superficial parotidectomy between May 2012 and August 2012. The outline of superficial and deep lobes of the parotid gland, parotid duct, and the buccal branch of the facial nerve were drawn on the transparent film by tracing the structures intraoperatively. Results: In 7 (58.3%) of 12 cases, the buccal branch of the facial nerve was located more caudally than the parotid duct at the anterior border of the superficial lobe of the parotid gland. In 3 cases (25%), the buccal branch was located more cephalically than the parotid duct. The mean distance between two structures were $2.54{\pm}1.48$ mm. In 11 cases, the parotid duct was located deeper than the buccal branch. Conclusion: The buccal branch of the facial nerve tends to be located more caudally than parotid duct and runs more superficially than parotid duct in all cases. We identified the relationship between the parotid duct and the buccal branch of the facial nerve during the operations on living subjects, not from the cadavers, so it would be a clinically helpful study which supplied more accurate anatomical information.

Activation of Vestibular Neurons Projecting to Autonomic Brain Stem Nuclei Following Acute Hypotension in Rats

  • Choi, Myoung-Ae;Wang, Won-Ki;Choi, Dong-Ok;Kim, Min-Sun;Park, Byung-Rim
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.8 no.3
    • /
    • pp.133-140
    • /
    • 2004
  • The purpose of the present study was to elucidate the possible involvement of the medial vestibular nucleus (MVN) and inferior vestibular nucleus (IVN) following acute hypotension in the vestibuloautonomic reflex through vestibulosolitary or vestibuloventrolateral projections. Acute hypotension-induced cFos expression was assessed in combination with retrograde cholera toxin B subunit (CTb) tract tracing. After injection of CTb into the solitary region, CTb-labeled neurons were located prominently around the lateral borders of the caudal MVN and medial border of the IVN. The superior vestibular nucleus also had a scattered distribution of CTb-labeled neurons. After injection of CTb toxin into the unilateral VLM, the distributions of CTb-labeled neurons in the MVN and IVN were similar to that observed after injection into the solitary region, although there were fewer CTb-labeled neurons. In the caudal MVN, about 38% and 13% of CTb-labeled neurons were double-labeled for cFos after injection of CTb into the solitary region and the VLM, respectively. In the IVN, 14% and 7% of CTb-labeled neurons were double-labeled for cFos after injection of CTb into the solitary region and the VLM, respectively. Therefore, the present study suggests that acute arterial hypotension may result in activation of vestibulosolitary pathways that mediate behavioral and visceral reflexes, and vestibuloventrolateral medullary pathways that indirectly mediate vestibulosympathetic responses.

A Study on the Determination of Instantaneous Centre of Rotation in the Mandibular Movement (하악골 운동의 순간회전 중심결정에 관한 연구)

  • Kang, Keun-Su;Yoon, Chang-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.25 no.1
    • /
    • pp.119-135
    • /
    • 1987
  • For the determination of instantaneous centre of rotation in the mandibular movement, the habitual opening path was recorded on the sagittal tracing plate by a Gnathorecorder attached on the lower anterior teeth which was designed for this study. The opening path was demonstrated mathematically and the instantaneous centre of rotation in the opening path were calculated and plotted by computer programs, and then a computer graphic movement of the mandible was obtained according to the opening path. The hinge path of posterior border movement was graphied by the Gnathorecorder as well and demonstated mathematically. This hinge path was compared with the same obtained by Visitrainer to prove a reliability of the Gnathorecorder. The results obtained from this study were as follows. 1. The habitual opening path and hinge path obtained from the Gnathorecorder movement were expressed mathematically as follows: $y=0.11x^2-0.66x+3.09$ (equation of opening path), $y=0.04x^2+0.21x+3.71$ (equation of hinge path), and a kinematic hinge axis was not shown in the equation of kings path. 2. The early habitual opening movement of the mandible demonstrated almost a straight opening path or an arc motion with the larger radius and it's centre of rotation moved parallelly in the more rear and lower position than a kinematic hinge axis. 3. Instantaneous centre of rotation occured along with the translation of the condyle, and mandible was rotated around an axis in the close to the maximum opening and then moved toward the forward and upward position. 4. There were some similarities between the articular eminence and the movement pattern of a special point which was the kinematic hinge axis.

  • PDF

Complete denture rehabilitation of edentulous patient with severe alveolar bone resorption using mandibular suction denture with closed mouth technique: a clinical report (치조골 흡수가 심한 완전 무치악 환자에서 폐구인상법을 이용한 총의치 수복 증례)

  • Ko, Chang Woo;Min, Byungkwee;Yang, Hong-so;Lim, Hyun-Pil;Yun, Kwidug;Shin, Jin-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.1
    • /
    • pp.56-62
    • /
    • 2018
  • When it comes to treat patient with loss of vestibule, conventional denture impression have limitation which can cause problems of excessive border extension. Suction denture with closed mouth technique which was introduced to solve this problem, forms negative pressure being sealed denture flanges by mobile mucosa when the patient swallows and chews. Also, it can decrease patient's visiting time by taking impression and gothic arch tracing at once. In this case, considering patient's chief complain which is a loose fit of present lower denture, suction dentures with closed mouth technique was planned.

Development of Automated Region of Interest for the Evaluation of Renal Scintigraphy : Study on the Inter-operator Variability (신장 핵의학 영상의 정량적 분석을 위한 관심영역 자동설정 기능 개발 및 사용자별 분석결과의 변화도 감소효과 분석)

  • 이형구;송주영;서태석;최보영;신경섭
    • Progress in Medical Physics
    • /
    • v.12 no.1
    • /
    • pp.41-50
    • /
    • 2001
  • The quantification analysis of renal scintigraphy is strongly affected by the location, shape and size of region of interest(ROI). When ROIs are drawn manually, these ROIs are not reproducible due to the operators' subjective point of view, and may lead to inconsistent results even if the same data were analyzed. In this study, the effect of the ROI variation on the analysis of renal scintigraphy when the ROIs are drawn manually was investigated, and in order to obtain more consistent results, methods for automated ROI definition were developed and the results from the application of the developed methods were analyzed. Relative renal function, glomerular filtration rate and mean transit time were selected as clinical parameters for the analysis of the effect of ROI and the analysis tools were designed with the programming language of IDL5.2. To obtain renal scintigraphy, $^{99m}$Tc-DTPA was injected to the 11 adults of normal condition and to study the inter-operator variability, 9 researchers executed the analyses. The calculation of threshold using the gradient value of pixels and border tracing technique were used to define renal ROI and then the background ROI and aorta ROI were defined automatically considering anatomical information and pixel value. The automatic methods to define renal ROI were classified to 4 groups according to the exclusion of operator's subjectiveness. These automatic methods reduced the inter-operator variability remarkably in comparison with manual method and proved the effective tool to obtain reasonable and consistent results in analyzing the renal scintigraphy quantitatively.

  • PDF