• Title/Summary/Keyword: Boost Factor

Search Result 512, Processing Time 0.026 seconds

Characteristics of a High Power Factor Boost Converter with Continuous Current Mode Control

  • Kim, Cherl-Jin;Jang, Jun-Young
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.4B no.2
    • /
    • pp.65-72
    • /
    • 2004
  • Switching power supply systems are widely used in many industrial fields. Power factor correction (PFC) circuits have a tendency to be applied in new power supply designs. The input active power factor correction (APFC) circuits can be implemented in either the two-stage approach or the single-stage approach. The two-stage approach can be classified into boost type PFC circuit and dc/dc converter. The power factor correction circuit with a boost converter used as an input power source is studied in this paper. In a boost power factor correction circuit there are two feedback control loops, which are a current feedback loop and a voltage feedback loop. In this paper, the regulation performance of output voltage and compensator to improve the transient response presented at the continuous conduction mode (CCM) of the boost PFC circuit is analyzed. The validity of designed boost PFC circuit is confirmed by MATLAB simulation and experimental results.

Boundary Current Mode Operated Bridgeless Boost Converter for Power Factor Correction (역률개선을 위해 경계전류모드로 동작하는 브리지리스 부스트 컨버터)

  • Yu Byung-Gyu;Lee Sung-Se;Han Sang-Kyu;Moon Gun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.90-94
    • /
    • 2003
  • Recently, many nations have released standard such as IEC 1000-3-2 and IEEE 519 which impose a limit on the harmonic current drawn by equipment connected to AC line in order to prevent the distortion of an AC line. Among the wide variety of active methods for improving power factor and harmonic distortion, the boost converter is very effective because it has a continuous line current , small choke filter and high power factor. In high power application, however, the bridge diode loss in the boost converter has made the efficiency lower and the temperature of the board higher. A new approach without bridge diode to make the same characteristics of the conventional boost converter has also been developed. This paper present the comparisons between the continuous current mode(CCM) operated conventional boost converter and the boundary current mode(BCM) operated the bridgeless boost converter for high efficiency and high power factor.

  • PDF

Power Factor Correction in ZVT PWM Boost Converter (ZVT PWM Boost 컨버터에 있어서의 역률개선)

  • Kim, Jin-Sung;Kim, Yang-Mo
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.619-621
    • /
    • 1996
  • This paper presents the study on the development of the power factor correction convener with ZVT Boost converter, which is better than the conventional PWM Boost converter to increase the switching frequency for high density and lower stress of switch. A simple DC and small signal model for the power factor correction converter with constant switching frequency is derived. The guide line for design of controller is summarized.

  • PDF

Power Factor Improvement of Single-Phase Three-level Boost Converter (단상 Three-level boost converter의 역률개선)

  • 서영조
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.384-387
    • /
    • 2000
  • In this paper Power factor correction circuit of single-phase three-level boost converter is proposed. The advantage of the proposed control scheme for three-level boost converter are low blocking voltage of each power device low THD(Total Harmonic Distortion) and high power factor. The control scheme is based on the current comparator capacitor compensator and region detector, In simulations the proposed system is validated.

  • PDF

A Study on the stability of boost power factor correction circuit with voltage feedback loop (전압제어루프를 고려한 부스트방식 역률개선회로의 안정도에 관한 연구)

  • Kim, Cherl-Jin;Jang, Jun-Young;Ji, Jae-Geun;Song, Yo-Chang
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.271-273
    • /
    • 2002
  • Switching power supply are widely used in many industrial field. Power factor correction(PFC) has become an increasingly necessary feature in new power supply designs. The power factor correction circuit using boost converter used in input of power source is studied in this paper. In a boost power factor correction circuit there are two feedback control loops, which are a current feedback loop and a voltage feedback loop. In this paper, it is analyzed regulation performance of output voltage and compensator to improve of transient response that presented at continuous conduction mode(CCM) of boost PFC circuit. The validity of designed boost PFC circuit is confirmed by simulation and experimental results.

  • PDF

Analysis of Current Ripple for Two-Phase Interleaved Boost PFC (2상 인터리브드 부스트 PFC의 전류 리플 해석)

  • Kim, Jung-Hoon;Jeon, Tae-Hyun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.61 no.3
    • /
    • pp.122-128
    • /
    • 2012
  • An interleaved boost converter has many advantages such as current ripple reduction, switching effective double, etc. Due to these advantages, the interleaved boost converter applies to the power factor correction circuit. However, there are almost no analysis results because the input voltage and current are time-varying system in the power factor correction application. Therefore, in this paper, the current ripples of the power factor correction circuit using single-phase boost dc-dc converter and 2-phase interleaved boost dc-dc converter are compared and analyzed in detail. In order to verify the validity, computer simulation and experimental are performed.

A New Power Factor Correction Circuit Using Boost Converter (부스트 컨버터를 이용한 새로운 역율 개선회로)

  • 김만고
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.21 no.2
    • /
    • pp.178-185
    • /
    • 1997
  • According to the wide - spread use of rectifier in electronic equipments, such problems as electronic components failures or equipment disorders have been occurred due to current harmonics. To overcome these problems, power factor correction circuits employing boost converter have been used. The high switching stress of boost converter can be reduced by snubber circuit. Recently, research activities in snubber circuits have been directed to energy recovery snubber for improving the efficiency of power converter. In this study, a new passive snubber circuit which can recover trapped snubber energy without added control is proposed for boost converter. The control of boost converter with proposed snubber is the same as the conventional one. In addition, the energy recovery circuit can be implemented with a few passive components. The circuit operation is confirmed through simulation.

  • PDF

A High Power Factor and High Efficiency Three Phase Boost Converter using auxiliary Partial Resonant circuit (보조 부분 공진 회로를 이용한 고역률 고효율 삼상 부스트 컨버터)

  • Suh, Ki-Young;Kwon, Soon-Kurl;Lee, Hyun-Woo;Kim, Young-Mun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.4
    • /
    • pp.212-218
    • /
    • 1999
  • A new partial resonant three phase boost converter with high power factor and high efficiency is proposed. The proposed boost converter is constructed by using a resonant network in parallel with the swithch of the conventional boost converter. The devices are switched at zero voltage or zero current eliminating the switching loss. A new auxiliary partial resonant boost converter achieves zero-voltage switching(ZVS) or zero-current switching(ZCS) for all switch devices without increasing their voltage and current stresses.

  • PDF

Interleaved Boost-Flyback Converter with Boundary Conduction Mode for Power Factor Correction

  • Lin, Bor-Ren;Chien, Chih-Cheng
    • Journal of Power Electronics
    • /
    • v.12 no.5
    • /
    • pp.708-714
    • /
    • 2012
  • This paper presents a new interleaved pulse-width modulation (PWM) boost-flyback converter to achieve power factor correction (PFC) and regulate DC bus voltage. The adopted boost-flyback converter has a high voltage conversion ratio to overcome the limit of conventional boost or buck-boost converter with narrow turn-off period. The proposed converter has wide turn-off period compared with a conventional boost converter. Thus, the higher output voltage can be achieved in the proposed converter. The interleaved PWM can further reduce the input and output ripple currents such that the sizes of inductor and capacitor are reduced. Since boundary conduction mode (BCM) is adopted to achieve power factor correction, power switches are turned on at zero current switching (ZCS) and switching losses are reduced. The circuit configuration, principle operation, system analysis, and design consideration of the proposed converter are presented in detail. Finally, experiments conducted on a laboratory prototype rated at 500W were presented to verify the effectiveness of the converter.

A Novel Boost PFC Converter Employing ZVS Based Compound Active Clamping Technique with EMI Filter

  • Mohan, P. Ram;Kumar, M. Vijaya;Reddy, O.V. Raghava
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.8 no.1
    • /
    • pp.85-91
    • /
    • 2008
  • A Boost Power Factor Correction (PFC) Converter employing Zero Voltage Switching (ZVS) based Compound Active Clamping (CAC) technique is presented in this paper. An Electro Magnetic Interference (EMI) Filer is connected at the line side of the proposed converter to suppress Electro Magnetic Interference. The proposed converter can effectively reduce the losses caused by diode reverse recovery. Both the main switch and the auxiliary switch can achieve soft switching i.e. ZVS under certain condition. The parasitic oscillation caused by the parasitic capacitance of the boost diode is eliminated. The voltage on the main switch, the auxiliary switch and the boost diode are clamped. The principle of operation, design and simulation results are presented here. A prototype of the proposed converter is built and tested for low input voltage i.e. 15V AC supply and the experimental results are obtained. The power factor at the line side of the converter and the converter efficiency are improved using the proposed technique.