• Title/Summary/Keyword: Bone wires

Search Result 49, Processing Time 0.031 seconds

Clinical and radiographic features of facial cosmetic materials: A systematic review

  • Alsufyani, Noura;Aldosary, Reem;Alrasheed, Rasha;Alsufyani, Mohammed
    • Imaging Science in Dentistry
    • /
    • v.52 no.2
    • /
    • pp.155-164
    • /
    • 2022
  • Purpose: The aim of this study was to systematically screen the literature for studies reporting cosmetic material in the oral and maxillofacial complex to shed light on the types of cosmetic materials, their radiographic appearance, and possible complications. Materials and Methods: Five electronic databases were reviewed for eligible studies. The general search terms were "cosmetic," "filler," "face," and "radiograph." Demographics, material types, clinical and radiographic presentation, and complications were recorded. Results: Thirty-one studies with 53 cases met the inclusion criteria. The mean age was 52.6±15.4 years with a 4 : 3 female-to-male ratio. The most common material was calcium hydroxyapatite (CaHa) (n=14, 26.4%), found incidentally. The materials were generally located within the upper cheek and zygoma (n=35, 66.0%), radiographically well-defined (n=44, 83%), and had no effects on the surrounding structures (n=27, 50.9%). The internal structure was radiopaque (calcification, hyperdensity) for gold wires, CaHa, bone implants, and secondary calcification or ossification. Outdated cosmetic materials or non-conservative techniques were infiltrative, had effects on the surrounding structures, and presented with clinical signs, symptoms, or complications. Conclusion: Conventional radiography, cone-beam computed tomography, and multi-detector computed tomography are useful to differentiate several cosmetic materials. Their magnetic resonance imaging appearance was highly variable. The infrequent inclusion of cosmetic materials in the differential diagnosis implies that medical and dental specialists may be unfamiliar with the radiographic appearance of these materials in the face.

MECHANO THERAPY OF PEDIATRIC CONDYLAR FRACTURES USING BENOIST'S APPLIANCCE : A CASE REPORT (Benoist씨 장치를 이용한 소아의 하악 과두 골절의 치험례)

  • Park, Sang-Wook;Cha, In-Ho;Kim, Seong-Oh;Choi, Byung-Jai;Choi, Hyung-Jun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.3
    • /
    • pp.453-458
    • /
    • 2004
  • Mandibular fracture is less common in children than in adults. However, children are more susceptible to ankylosis and developmental disorders, and don't respond as well to intermaxillary fixation compared to adults. On the other hand, bone fracture is healed more quickly in children and complications are scarce. Mandibular fracture in children is usually treated successfully with acrylic splint therapy with or without the use of eyelet wires and intermaxillary fixation. Severe complications that include ankylosis and developmental disorders may occur. The frequency and severity of such complications can be mitigated with a shorter duration of intermaxillary fixation and good post-operative care. Encouraging mandibular physical therapy by increasing patient motivation may be necessary in such cases where the patient's response is poor and the duration of intermaxillary fixation increases; when the patient is unable to undergo physical therapy, or when intermaxillary fixation is not necessary with the patient showing only minor symptoms such as trismus. In this case report, a 6 year-old girl with bilateral condylar fracture was treated with elastic in both the upper and lower jaws to allow mandibular physical therapy using a Benoist's appliance, which allows opening, lateral, and protrusive retrusive movements of the mandible. A 7-month follow-up showed beneficial therapeutic effects such as increased mandibular movement and prevention of condylar ankylosis.

  • PDF

Pulmonary Aspergillosis Secondary to Open Fracture of Pneumatic Bone in a Brown Hawk Owl (Ninox scutulata) (솔부엉이의 함기골 개방골절에 의한 속발성 폐 아스퍼질러스 감염 증례)

  • Han, Jae-Ik;Lee, Young-Sun;Lee, Sook-Jin;Kang, Hyo-Min;Jang, Hye-Jin;Chang, Dong-Woo;Na, Ki-Jeong
    • Journal of Veterinary Clinics
    • /
    • v.30 no.3
    • /
    • pp.218-221
    • /
    • 2013
  • A flightless brown hawk owl (Ninox scutulata) weighing 180 g was rescued and referred to the teaching veterinary hospital with humerus open fracture. On physical examination and radiography, open fracture of the left humerus was found. After 3 days, orthopedic surgery was operated with intramedullary pins and wires. The bird died 2 days after surgery with anorexia. On necropsy, multiple green nodules with 2-3 mm in diameter were observed at the surface and inside of the left lung. Numerous conidial heads and spores were seen in the center of foci in the histopathological examination. The mycelia penetrated the surrounding pulmonary parenchyma, showing inflammation and necrosis. The fungus was isolated from the lung and cultured on Sabouraud Dextrose Agar at $30^{\circ}C$ for 7 days. The colony was blue-green color with a powdery surface. The fungus was identified as Aspergillus fumigatus by DNA analysis, including the internal transcribed spacer region, partial ${\beta}$-tubulin, and the calmodulin gene. This case was diagnosed as pulmonary aspergillosis secondary to open fracture of pneumatic bone in a brown hawk owl.

Using a Kirschner wire as an internal splint at nasal fractures accompanied fracture of frontal process of maxilla or perpendicular plate of ethmoid (상악골 전두돌기 골절 및 사골 수직판 골절을 동반한 비골 골절에서 K 강선을 이용한 내고정)

  • Rho, Kyoung Hwan;Yoon, Eul Sik;Yoon, Byung Min;Dhong, Eun Sang
    • Archives of Plastic Surgery
    • /
    • v.36 no.5
    • /
    • pp.623-628
    • /
    • 2009
  • Purpose: In cases where nasal fractures involve frontal process of maxilla or perpendicular plate of ethmoid, 4 - 5 days of nasal packing may not provide sufficient support for avoiding displacement after packing removal. Therefore a single Kirschner - wire(K - wire) is used as an internal splint when nasal fractures involve the above two areas. Methods: Thirty five patients during the last 3 practical years were treated with a K -wire pinning according to the anatomic locations of nasal fractures. We performed a retrospective study using 13 nasal fractures out of total 35 patients. Among 13 cases, 10 patients involved frontal process of maxilla, and 3 patients were diagnosed as bilateral nasal side wall fractures accompanied with fractures of perpendicular plate of ethmoid. One patient of the last three cases had been augmented with dorsal silicone implant long before the trauma. We analyzed the anteroposterior displacement of key stone area and the width between both lateral walls by comparing immediate postoperative radiographs with 2 month follow - ups. To reduce the errors, the same measurements were taken by two different inspectors, and the mean of each inspector's measurements was compared. Patient satisfaction was analyzed using a questionnaire regarding the esthetic and functional outcomes. Results: Ten patients underwent a longitudinal K - wire fixation in submucoperiosteal plane underneath the frontal process of maxilla. And three patients underwent a transverse K - wire fixation from the one side of lateral wall to the perpendicular plate of ethmoid and to the other side of lateral wall. The mean postoperative anteroposterior displacement of the key stone area measured by two inspectors were 1.84% and 3.06%; mean narrowing of bony pyramid were 1.33% and 1.48%, respectively. Subjective satisfaction scores regarding the esthetic appearance and the maintenance of nasal shape compared with immediate post - operative state with the long term ones were not different (p>0.05). Conclusion: K - wire pinning after closed reduction is a reliable and useful method for the treatment of nasal fractures involving frontal process of maxilla or perpendicular plate of ethmoid. This is because it achieves longer intranasal support after reduction. This method also leaves conspicuous external scar, and minimal soft - tissue injury.

Study of heat transfer to the implant-bone interface induced by grinding of occlusal surface of implant gold prosthesis (금 합금 보철물의 교합면 삭제로 인한 임플란트-골 계면으로의 열전달에 관한 연구)

  • Jo, Jae-Young;Kang, Sun-Nyo;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo;Jeon, Young-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.1
    • /
    • pp.29-35
    • /
    • 2012
  • Purpose: The purpose of this study was to analyze temperature change along the implant-bone interface induced by grinding the occlusal surface of implant gold prosthesis and to compare the temperature generated by grinding of prosthesis with different cooling methods. Materials and methods: The experimental gold prostheses were fabricated with dental gold alloy and castable abutment. The prostheses had 3 cylindrical protrusions on the occlusal surface with 1mm in height. Temperature was measured using 16 thermocouple wires attached to the implant fixture surface and the fixture was embedded in an acrylic resin block inside the $37^{\circ}C$ water bath. Cylinders were grinded for a period of 30 second with a low-speed handpiece with green stone point. One cylindrical protrusion was grinded without cooling, the second one was grinded with air blow, and the third one was grinded with water-spray. Results: The mean maximum temperature was measured more than $47^{\circ}C$ of the implant and the maximum temperature was measured at the cervical portion of the implant in the group without cooling. There was statistically significant difference between the group without cooling and the groups with cooling (P<.05). However, there was no significant difference at all portion of implant in the groups with cooling (P>.05). Conclusion: The results of this study support that the grinding of implant gold prosthesis without cooling may damage the peri-implant tissue. The continuous use of air blow and water-spray adjacent to prosthesis during the grinding of implant gold prosthesis may prove to be beneficial for cooling of the implant.

A study on the effect of the magnitude of the gable bends on the tooth movement pattern during on-masse space closure in the maxillary dentition (상악전치 후방 견인시 견인 loop후방에 부여한 gable bend 양에 따른 치아이동 양상에 관한 연구)

  • Chun, Youn-Sic;Row, Joon;Jung, Sang-Hyuk;Kim, Hui-Jung
    • The korean journal of orthodontics
    • /
    • v.34 no.1 s.102
    • /
    • pp.33-45
    • /
    • 2004
  • The purpose of this experimental study was to determine appropriate magnitude of the Gable bends to produce maximum retraction of the anterior teeth. The Calorific Machine was used to illustrate the tooth movement in three dimension. The experimental teeth except the first premolar were embedded in the artificial alveolar bone part. In a series of experiments, the extraction space was closed using arch wires with bull loops into which the gable bends of $10^{\circ},\;20^{\circ},\;30^{\circ}$ degrees were incorporated. The experiments were repeated three times for each degree of the gable bend. Before and after the space closure, radiographs were taken in the sagittal and occlusal directions using occlusal films. Analysis of variance and Scheffe post hoc test were used to determine significant differences among the three groups. The following results were obtained. 1. As magnitudes of the gable bends increased, more bodily anterior tooth movement was seen and the distance of retraction also increased. 2. As magnitudes of the gable bends increase, the amount of posterior tooth protraction decreased while intrusive and buccal movement increased. 3. The arch was coordinated by distal-in rotation of the canine and mesial-in rotation of the second premolar adjacent to the extraction space.

REMOVABLE FLEXIBLE DENTURE FOR CHILDREN WITH OLIGODONTIA : A CASE REPORT (탄성의치를 사용한 부분무치증 환아의 보철적 수복)

  • Kim, Jin-Young;Lee, Kwang-Hee;La, Ji-Young;Lee, Dong-Jin;An, So-Youn;Kim, Yun-Hee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.1
    • /
    • pp.150-156
    • /
    • 2009
  • Objectives : The conventional removable appliance, composed of wires and acrylic resin, had unaesthetic results and poor retention. The flexible denture, as an alternative, presents improved aesthetics with the thin and strong resin retentive area. In addition, it also enhances patients' sensory function as a result of decreased volume of denture base. The flexibility of the flexible denture reduces the possibility of fracture and distributes the masticatory forces transmitted to the abutments and residual bone tissue. This report describes a 10-year-old girl and a 6-year-old boy with oligodontia treated with the flexible dentures as an alternative to conventional removable appliances. Methods : Impression was taken using alginate material and sent to a laboratory with the bite for fabrication of the flexible denture. Prior to try-in, the flexible denture was immersed in water at $90^{\circ}C$ for one minute and cooled. Impinging area of the denture was checked by $Fit-Checker^{(R)}$ and removed and the denture was delivered to the patient. Results : Both patients were satisfied with the flexible dentures, which presented improved retention and aesthetics. Conclusion : For patients with oligodontia, flexible dentures can be considered as a treatment of choice, which may replace the conventional denture.

  • PDF

Characteristics of Fluoride Releasing of Anodized Titanium Implant (양극산화 아크방전 처리한 티타늄 임플란트의 불소방출 특성)

  • Kim, Ha-young;Song, Kwang-yeob;Bae, Tae-sung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.4
    • /
    • pp.361-369
    • /
    • 2008
  • The purpose of this study is to make porous oxide film on the surfaces of pure Ti through anodic spark discharge in electrolytic solution containing calcium and phosphate ions, to improve osseointergration by treating fluoride agent. In addition, it is to evaluate the fluoride modified effect on the surface. Commercial pure Ti plate with $20{\times}10{\times}2mm$ and Ti wire with a diameter of 1.5mm and a total length of 15mm were used. After making titanium oxide films converted by anodic spark discharge, anodizing was performed. Fluoride was spreaded to titanium laboratory plate and maintained for 30 minutes after anodizing breakdown. Fluoride ion discharge amount was measured per 24 hours after dipping titanium plate into saline (10ml) and sustaining 90rpm in a pyrostat. Some plates and wires were dipped in Hanks solutions for a month to examine biocompatibility using SEM and XRD. $TiO_2$ film formed by anodic discharge technique showed great roughness and uniform pores which were $1{\sim}3{\mu}m$ in a diameter. Roughness of the films treated with anodic discharge after blasting were higher than the turned ones(P<0.05). Rapid surface activity was observed in the samples treated with $TiF_3$ agent, which immersed in Hanks solution for 30 days. Taking the results into consideration, the fluoride modified implant with anodic discharge demonstrates that it makes uniformly porous oxide film on the surface of implant and properly increase roughness for osseointegration. The implants will achieve greater bone integration after short healing time by improving surface activity.

Radiological Comparison between $60^{\circ}$ Distal Chevron Osteotomy and $40^{\circ}$ Distal Chevron Osteotomy in Hallux Valgus (족무지 외반증에서 $60^{\circ}$ 원위부 갈매기형 절골술과 $40^{\circ}$ 원위부 갈매기형 절골술 간의 방사선학적 비교)

  • Rha, Jong-Deuk;Park, Hyun-Soo;Lim, Chang-Suk;Jang, Young-Soo;Jeon, Yong-Soo;Jin, Hyun-Bae;Kim, Kyung-Hun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.9 no.2
    • /
    • pp.146-150
    • /
    • 2005
  • Purpose: We made a radiological comparison between $60^{\circ}$ distal Chevron osteotomy with short armed two parts and $40^{\circ}$ distal Chevron osteotomy with long armed one part performing operation in cases of hallux valgus angle of less than $40^{\circ}$, intermetatarsal angle of less than $15^{\circ}$. Materials and Methods: 12 cases with $60^{\circ}$ distal Chevron osteotomy and 12 cases with $40^{\circ}$ distal Chevron osteotomy were selected from October 2000 to March 2005. We have analysed the hallux valgus angle, 1-2 intermetatarsal angle, metatarsal length, distal metartarsal articular angle and angulation at osteotomy site on lateral view in each radiological films taken at preoperative, postoperative and 3 months after operation presuming bone union. All cases were women, both sides were 9 cases and average age was 52.3 years old. Results: Data taken at preoperative, postoperative and 3 months follow up films in $60^{\circ}$ distal Chevron osteotomy were as follows; the hallux valgus angles were $32.1^{\circ}$, $10.9^{\circ}$, $13.8^{\circ}$, the 1-2 intermetatarsal angles were $13.6^{\circ}$, $8.5^{\circ}$, $8.4^{\circ}$, the metatarsal length were 60.6 mm, 58.8 mm, 58 mm, the distal metartarsal articular angles were $13^{\circ}$, $6^{\circ}$, $6.6^{\circ}$ and 3 cases were over $3^{\circ}$ angulation at lateral view. In $40^{\circ}$ distal Chevron osteotomy, the hallux valgus angles were $34.5^{\circ}$, $11.6^{\circ}$, $15.3^{\circ}$, the 1-2 intermetatarsal angles were $12.7^{\circ}$, $8.2^{\circ}$, $7.8^{\circ}$, the metatarsal length were 59.2 mm, 56.9 mm, 55.9 mm, the distal metartarsal articular angles were $12^{\circ}$, $7.3^{\circ}$, $7.3^{\circ}$ and there were no case with angulation over $3^{\circ}$ at lateral view. Conclusion: In comparison between $60^{\circ}$ distal Chevron osteotomy and $40^{\circ}$ distal Chevron osteotomy measuring at postoperative and follow up, most of all data were similar, but 3 cases over $3^{\circ}$ angulation at lateral view happened in $60^{\circ}$ Chevron osteotomy. This result showed that $40^{\circ}$ distal Chevron osteotomy fixing with screws through long armed one part may have benefit than $60^{\circ}$ distal Chevron osteotomy fixing with K-wires through short armed two parts in making rigid fixation, even though there is a personal difference of technigue.

  • PDF