• Title/Summary/Keyword: Bone scanning

Search Result 287, Processing Time 0.03 seconds

Comparative analysis of carrier systems for delivering bone morphogenetic proteins

  • Jung, Im-Hee;Lim, Hyun-Chang;Lee, Eun-Ung;Lee, Jung-Seok;Jung, Ui-Won;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.45 no.4
    • /
    • pp.136-144
    • /
    • 2015
  • Purpose: The objective of this study was to comparatively assess the bone regenerative capacity of absorbable collagen sponge (ACS), biphasic calcium phosphate block (BCP) and collagenated biphasic calcium phosphate (CBCP) loaded with a low dose of recombinant human bone morphogenetic protein-2 (rhBMP-2). Methods: The CBCP was characterized by X-ray diffraction and scanning electron microscopy. In rabbit calvaria, four circular 8-mm-diameter defects were created and assigned to one of four groups: (1) blood-filled group (control), (2) rhBMP-2-soaked absorbable collagen sponge (0.05 mg/mL, 0.1 mL; CS group), (3) rhBMP-2-loaded BCP (BCP group), or (4) rhBMP-2-loaded CBCP (CBCP group). The animals were sacrificed either 2 weeks or 8 weeks postoperatively. Histological and histomorphometric analyses were performed. Results: The CBCP showed web-like collagen fibrils on and between particles. Greater dimensional stability was observed in the BCP and CBCP groups than in the control and the CS groups at 2 and 8 weeks. The new bone formation was significantly greater in the BCP and CBCP groups than in the control and CS groups at 2 weeks, but did not significantly differ among the four groups at 8 week. The CBCP group exhibited more new bone formation in the intergranular space and in the center of the defect compared to the BCP group at 2 weeks, but a similar histologic appearance was observed in both groups at 8 weeks. Conclusions: The dose of rhBMP-2 in the present study enhanced bone regeneration in the early healing period when loaded on BCP and CBCP in rabbit calvarial defects.

New Bone Formation in Experimental Model of Vascularized Periosteal Flap for the Bone Defect in the Shaft of the Radius of Rabbit - Radiological, Histological and Immunohistochemical Study - (가토 요골 간부 골 결손시에 혈관 부착 골막 보존 유무에 따른 신생골 형성에 대한 실험적 연구)

  • Chung, Duke-Whan;Yum, Jae-Kwang;Tae, Suk-Kee;Ko, Kwang-Won
    • Archives of Reconstructive Microsurgery
    • /
    • v.8 no.2
    • /
    • pp.97-107
    • /
    • 1999
  • The osteogenic capacity of the vascularized periosteum autograft has been extensively demonstrated by experimental works. The objective of this study was to characterize the behavior of experimental model of vascularized periosteal flap(VPF) by observing sequential stages of osteogenesis after simulated VPF in rabbits. In experimental group, segmental resection of bone including the periosteum was performed in 22 radii of 22 New Zealand white rabbits preserving the periosteal circulation of median artery to the periosteum. In order to simulate the transplantation of VPF, the vascular pedicle consisting of median artery and veins was dissected from adjacent soft tissue and the periosteum was longitudinally incised to remove the bone followed by repair of the periosteum. From the first to sixteenth week after the simulated VPF, the changes in VPFs were observed by radiological, light microscopical, scanning electron microscopical methods and the activity of osteocalcin was measured by immunohistochemical method. In control group, the bone tissue and periosteum were completely removed from the mid-shaft of radius and the findings were observed by radiological and light microscopical methods. From the results of this study, it is demonstrated that the experimental model of VPF is vigorously and uniformly osteogenic. Therefore it is thought that VPF can be used as a measure to treat bone defect of shaft of long bone.

  • PDF

Determination of the optimal diabetes duration for bone regeneration experiments in an alloxan-induced diabetic rabbit calvarial defect model

  • Jeong, Sang-Hun;Jung, Bo Hyun;Yoo, Ki-Yeon;Um, Heung-Sik;Chang, Beom-Seok;Lee, Jae-Kwan;Choi, Won-Youl
    • Journal of Periodontal and Implant Science
    • /
    • v.48 no.6
    • /
    • pp.383-394
    • /
    • 2018
  • Purpose: The purpose of this study was to evaluate the optimal diabetes duration for bone regeneration experiments in an alloxan monohydrate (ALX)-induced diabetic rabbit calvarial defect model by evaluating the association between diabetes duration and bone healing capacity. Methods: Twenty-four New Zealand white rabbits were used. Twenty-two rabbits were injected with 100 mg/kg of ALX to induce experimental diabetes. These rabbits were divided into 4 groups, including a control group and groups with diabetes durations of 1 week (group 1), 2 weeks (group 2), and 4 weeks (group 3). Calvarial defects were created at 1, 2, and 4 weeks after ALX injection and in the control rabbits. Cone-beam computed tomography (CBCT) scanning was performed on the day of surgery and at 2 and 4 weeks after surgery. The rabbits were sacrificed 4 weeks after surgery, followed by histological and immunofluorescence analysis. Results: The diabetic state of all diabetic rabbits was well-maintained throughout the experiment. Reconstructed 3-dimensional CBCT imaging showed more rapid and prominent bone regeneration in the control group than in the experimental groups. Histological staining showed notable bone regeneration in the control group, in contrast to scarce bone formation in the experimental groups. The appearance and immunoreactivity of receptor activator of nuclear factor-kappa B and osteoprotegerin did not show notable differences among the groups. Conclusion: ALX administration at 100 mg/kg successfully induced experimental diabetes in rabbits. The effect of diabetes on bone healing was evident when the interval between diabetes induction and the intervention was ${\geq}1$ week.

Full mouth rehabilitation of the patient with crossed occlusion using implant fixed prosthesis: A case report (엇갈린 교합 환자에서 임플란트 고정성 보철물을 이용한 수복증례)

  • Jung, Byung-Suk;Jeon, Young-Chan;Jeong, Chang-Mo;Yun, Mi-Jung;Lee, So-Hyoun;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.4
    • /
    • pp.338-346
    • /
    • 2018
  • Crossed occlusion can be treated either by overdenture and telescopic denture or by placing an implant at the edentulous area to reestablish the support on the occlusion. If alveolar bony support is sufficient and an the environment where an implant is inserted is favorable to restoring the masticatory and aesthetic function of a patient, the implant-supported fixed prosthesis can provide more definitive occlusal support and more aid for other oral functions. In this case report, a patient with a severe residual alveolar bone resorption following the extraction of teeth and who had a crossed occlusion was treated with sinus bone graft and alveolar bone augmentation in order to place the implants at prosthetically position. The definitive restoration was made to reflect the patient's occlusal and aesthetic function using the CAD/CAM double scanning method. Finally, the treatment had the masticatory and aesthetic function adequately restored, which is reported here.

$^{99m}Tc$-MDP Bone Scan in the Cases of Muscle Necrosis Associated with Acute Renal Failure (급성(急性) 신부전(腎不全)이 동반(同伴)된 근양사(筋壤死)에 있어서의 $^{99m}Tc$-MDP 골주사(骨走査))

  • Moon, H.B.;Han, J.S.;Kim, S.Y.;Cho, B.Y.;Lee, J.S.;Koh, C.S.;Cho, K.S.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.14 no.2
    • /
    • pp.61-66
    • /
    • 1980
  • We studied four patients with muscle necrosis associated with acute renal failure to evaluate the diagnostic value of the bone scan in this disease. The illness followed carbon monoxide poisoning in two patients, acute physical exertion in one and contaminated intramuscular injection in the other. Whole-body rectilinear bone scans using technetium 99m-methyldiphosphonate were done. In all patients, increased muscle labelling at the regions of suspected muscle injury was showed, and in one, it was after normalization of serum muscle enzyme levels. In one patient, the bone scan was rechecked 8 months later and showed no residual abnormality. Above all, the site and precise extent of muscle injury could be detected and the degree of muscle labelling seemed to correlate with the severy of muscle injury. These findings suggest that isotope scanning may be useful in the diagnosis of patients with acute muscle necrosis.

  • PDF

Biophysical properties of PPF/HA nanocomposites reinforced with natural bone powder

  • Kamel, Nagwa A.;Mansour, Samia H.;Abd-El-Messieh, Salwa L.;Khalil, Wafaa A.;Abd-El Nour, Kamal N.
    • Advances in materials Research
    • /
    • v.4 no.3
    • /
    • pp.145-164
    • /
    • 2015
  • Biodegredable and injectable nanocomposites based on polypropylene fumarate (PPF) as unsaturated polyester were prepared. The investigated polyester was crosslinked with three different monomers namely N-vinyl pyrrolidone (NVP), methyl methacrylate (MMA) and a mixture of NVP and MMA (1:1 weight ratio) and was filled with 45 wt% of hydroxyapatite (HA) incorporated with different concentrations of chemically treated natural bone powder (NBP) (5, 10 and 15 wt%) in order to be used in treatment of orthopedics bone diseases and fractures. The nanocomposites immersed in the simulated body fluid (SBF) for 30 days, after the period of immersion in-vitro bioactivity of the nanocomposites was studied through Fourier transform infrared (FTIR), scanning electron microscope (SEM), energy dispersive X-ray (EDX) in addition to dielectric measurements. The degradation time of immersed samples and the change in the pH of the SBF were studied during the period of immersion.

Fabrication and Characterization of Functional Gradient Ceramic Bone Substitutes

  • Kim, Min-Seong;Min, Yeong-Gi;Yang, Hun-Mo;Song, Ho-Yeon;Lee, Byeong-Taek
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2010.05a
    • /
    • pp.42.2-42.2
    • /
    • 2010
  • Recently, highly porous bone substitutes, which have interconnected open pore structure, have been focused on improving their mechanical properties and modifying their functions. Especially, it is highly required to develop functional gradient structured bone substitute which is available for controlling their material properties such as bioresorption rate and elastic modulus. Porous $ZrO_2$ scaffold was fabricated by the sponge replica method using PU sponge. After 3 times of dip coating and the subsequent oven drying, burning out and microwave sintering were carried out. Various $ZrO_2$-BCP powder mixtures were prepared depending on the ratio and coated on the $ZrO_2$ scaffold by dip coating process. X-ray diffraction analysis was performed to characterize the phase identification of the scaffolds. Microstructures of the bone substitutes were observed using scanning electron microscopy.

  • PDF

A Study on the Tissue Response and Bone Formation after Augmentation Using Proplast and Porous Polyethylene in Rabbit Mandible (Proplast와 Porous Polyethylene을 이용(利用)한 가토(家兎) 하악골(下顎骨) 증대술후(增大術後) 조직반응(組織反應) 및 골형성(骨形成)에 관(關)한 연구(硏究))

  • Kim, Geon-Jung;Ryu, Sun-Youl
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.11 no.1
    • /
    • pp.101-116
    • /
    • 1989
  • Proplast and Porous Polyethylene which have porous structures as low-modulus polymers have been recently used in maxillofacial plastic and reconstructive surgery. The purpose of this study was to compare the response of adajacent tissue, new bone formation and stability after augmentation by differen methods of subperiosteal graft using proplast and purous polythylene in rabbit mandible. The augmentation procedure was carried out by dividing into two groups, A and B. A group consisted of subperiosteal graft on the cortex, and the other B group was made up only graft following artificial decortication in the mandibular body of rabbit. The experimental animals were sacrificed on the 1st, 2nd, 4th and 8th week after grafting for macroscopic and light microscopic examination. The samples extracted at the 6th postgrafting week were also used for biometric testing and scanning electron microscopic examination. The results obtained from this study were as follows : 1. Macroscopically, infection of graft site, deformation and migration of graft material were not observed in all experimental groups. 2. B group showed more rapid and increased bone formation and the greater stability than A group, and tissue response was similar to each other. 3. In the tissue response, macrophages and cellular infiltrations were observed in Proplast group, but few in PHDPE group. 4. In bone formation of A group, Proplast group showed no bone formation until the 8th week, but PHDPE group showed small quantity of osteoid tissue from the 2nd week and appositional bone growth with new bone formation at the 8th week. 5. In bone formation of B group, both Proplast and PHDPE group showed bone formation, but PHDPE group showed more rapid and larger bone formation. 6. In pattern of bone formation, Proplast group mainly showed appositional bone growth pattern connected with graft site. On the other hand, PHDPE group showed mixed pattern of new bone formation in the pore connective tissue with appositional bone growth from graff site. 7. The maximum mean values of shear stress were serially $111.3gf/mm^{2}$ in PHDPE of B group, $84.8gf/mm^{2}$ in PHDPE of A group, $32.9gf/mm^{2}$ in Proplast B group, and $15.7gf/mm^{2}$ in Proplast of A group. From above results, It was suggested that the capacity of bone formation and stability between bone and graft material were dependent on the pore size and structure of graft material itself, the state of graft site and tissue response.

  • PDF

Clinical Analysis of Frostbite (동상의 임상적 분석)

  • Choi, Jang Kyu;Kim, Hyun Chul;Shin, Hong Kyung
    • Journal of Trauma and Injury
    • /
    • v.28 no.3
    • /
    • pp.158-169
    • /
    • 2015
  • Purpose: Frostbite can affect still soldiers. Initial clinical manifestations are similar for superficial and deep frostbite, so early treatment is identical. It is under-estimated by physicians. We try to identify the challenges of managing these complex tissue injuries. Methods: A retrospective analysis of 84 patients hospitalized at AFCH from 2009 to 2015 was conducted. We investigated differences of epidemiological characteristics, identification of soft tissue injury, treatment and complications between superficial (SF: 43; 51.2%) and deep (DF: 41; 48.8%) frostbite. Results: The major (94.0%) developed frostbite in dry circumstances (89.3%). Wet circumstances (66.7%) were more susceptible to DF rather than dry (46.7%). The 38 (45.2%) arrived to specialist within 7days. Most prone sites were feet, followed by hands. Toes had more deep injuries. DF presented more increased levels of ALT, CPK, CKMB, CRP. The bone scan of W+S+ was 48.3%, 87.1% and W+S- was 20.7%, 12.9%, respectively. The treatment resulted in improved or normalized perfusion scan with matching clinical improvement. It was a good tool to assess treatment response. Eighteen normal and 8 stenotic type of PCR resulted in normal with matching clinical improvement. One continuous obstructive waveform led to minor amputation. Twelve underwent both PCR and MRA. Among 6 normal PCR, 5 showed normal and one stenosis in MRA. All 5 stenosis and one obstruction showed the same findings in MRA. It was a good tool to evaluate vascular compromise. They were treated with rapid rewarming (11.6%, 22.0%), hydrotherapy (16.3%, 29.3%), respectively. Six (14.6%) underwent STSG, 2 (4.9%) had digital amputation in DF. Berasil, Ibuprofen, Trental were commonly administered. PGE1 was administered selectively for 6.8, 10.8 days, respectively. Raynaud's syndrome (16.3%), CRPS (4.7%), LOM (14.6%) and toe deformity (4.9%) were specific sequelae. Conclusion: We should recommend intensive foot care education, early rewarming and evacuation to specialized units. The bone scanning and PCR should allow for a more aggressive and active approach to the management of tissue viability.

  • PDF

Energy-dispersive X-ray spectroscopic investigation of a fractured non-submerged dental implant associated with abutment fracture

  • Truc Thi Hoang Nguyen;Mi Young Eo;Kezia Rachellea Mustakim;Mi Hyun Seo;Hoon Myoung;Soung Min Kim
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.49 no.1
    • /
    • pp.43-48
    • /
    • 2023
  • The biocompatibility and durability of implant fixtures are major concerns for dentists and patients. Mechanical complications of the implant include abutment screw loosening, screw fracture, loss of implant prostheses, and implant fracture. This case report aims to describe management of a case of fixture damage that occurred after screw fracture in a tissue level, internal connection implant and microscopic evaluation of the fractured fixture. A trephine bur was used to remove the fixture, and the socket was grafted using allogeneic bone material. The failed implant was examined by scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS), which revealed a fractured fixture with both normal and irregular bone patterns. The SEM and EDS results give an enlightenment of the failed fixture surface micromorphology with microfracture and contaminated chemical compositions. Noticeably, the significantly high level of gold (Au) on the implant surface and the trace amounts of Au and titanium (Ti) in the bone tissue were recorded, which might have resulted from instability and micro-movement of the implant-abutment connection over an extended period of time. Further study with larger number of patient and different types of implants is needed for further conclusion.