• Title/Summary/Keyword: Bone scanning

Search Result 287, Processing Time 0.027 seconds

Osseointegration of the titanium implant coated with rhTGF-${\beta}2$/PLGA particles by electrospray: a preliminary microCT analyzing rabbit study (rhTGF-${\beta}2$/PLGA 복합체를 electrospray법으로 코팅한 타이타늄 임플란트 골 유착의 microCT 계측: a preliminary rabbit study)

  • Lee, Woo-Sung;Kim, Seong-Kyun;Heo, Seong-Joo;Koak, Jai-Young;Lee, Joo-Hee;Park, Ji-Man;Park, Yoon-Kyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.4
    • /
    • pp.298-304
    • /
    • 2014
  • Purpose: This preliminary rabbit study was conducted to evaluate the effect of recombinant human transforming growth factor-${\beta}2$ (rhTGF-${\beta}2$)/poly lactic-co-glycolic acid (PLGA) coating on osseointegration of the titanium (Ti) implant. Materials and methods: Eight Ti implants were anodized with 300 voltages for three minutes. Four of those were coated with rhTGF-${\beta}2$/PLGA by an electrospray method as the experimental group. The implants were placed into tibiae of four New Zealand rabbits, two implants per a tibia, one implant per each group. After 3 and 6 weeks, every two rabbits were sacrificed and micro-computed tomography (microCT) was taken for histomorphometric analysis. Results: In scanning electron microscope (SEM) image, the surface of rhTGF-${\beta}2$/PLGA coated Ti implant showed well distributed particles. Although statistically insignificant, microCT analysis showed that experimental group has higher bone volume / total volume (BV/TV) and trabecular thickness (Tb.Th) values relatively. Cross sectional view also showed more newly formed bone in the experimental group. Conclusion: In the limitation of this study, rhTGF-${\beta}2$/PLGA particles coating on the Ti implant show the possibility of more favorable quantity of newly formed bone after implant installation.

A STUDY ON THE RESPONSES OF OSTEOBLASTS TO VARIOUS SURFACE-TREATED TITANIUM

  • Lee Joung-Min;Kim Yung-Soo;Kim Chang-Whe;Jang Kyung-Soo;Lim Young-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.3
    • /
    • pp.307-326
    • /
    • 2004
  • Statement of problem. The long-term success of implants is the development of a stable direct connection between bone and implant surface, which must be structural and functional. To improve a direct implant fixation to the bone, various strategies have been developed focusing on the surface of materials. Among them, altering the surface properties can modify cellular responses such as cell adhesion, cell motility and bone deposition. Purpose. This study was to evaluate the cellular behaviors on the surface-modified titanium by morphological observation, cellular proliferation and differentiation. Material and methods. Specimens were divided into five groups, depending on their surface treatment: electropolishing(EP) anoclizing(AN), machining(MA), blasting with hydroxyapatite particle(RBM) and electrical discharge machining(EDM). Physicochemical properties and microstructures of the specimens were examined and the responses of osteoblast-like cells were investigated. The microtopography of specimens was observed by scanning electron microscopy(SEM). Surface roughness was measured by a three-dimensional roughness measuring system. The microstructure was analyzed by X-ray diffractometer(XRD) and scanning auger electron microscopy(AES). To evaluate cellular responses to modified titanium surfaces, osteoblasts isolated from neonatal rat were cultured. The cellular morphology and total protein amounts of osteoblast-like cell were taken as the marker for cellular proliferation, while the expression of alkaline phosphatase was used as the early differentiation marker for osteoblast. In addition, the type I collagen production was determined to be a reliable indicator of bone matrix synthesis. Results. 1. Each prepared specimen showed specific microtopography at SEM examination. The RBM group had a rough and irregular pattern with reticulated appearance. The EDM-treated surface had evident cracks and was heterogeneous consisting of broad sheet or plate with smooth edges and clusters of small grains, deep pores or craters. 2. Surface roughness values were, from the lowest to the highest, electropolished group, anodized group, machined group, RBM group and EDM group. 3. All groups showed amorphous structures. Especially anodized group was found to have increased surface oxide thickness and EDM group had titaniumcarbide(TiC) structure. 4. Cells on electropolished, anodized and machined surfaces developed flattened cell shape and cells on RBM appeared spherical and EDM showed both. After 14 days, the cells cultured from all groups were formed to be confluent and exhibited multilayer proliferation, often overlapped or stratified. 5. Total protein amounts were formed to be quite similar among all the group at 48 hours. At 14 days, the electropolished group and the anodized group induced more total protein amount than the RBM group(P<.05). 6. There was no significant difference among five groups for alkaline phosphatase(ALP) activity at 48 hours. The AN group showed significantly higher ALP activity than any other groups at 14 days(P<.05). 7. All the groups showed similar collagen synthesis except the EDM group. The amount of collagen on the electropolished and anodized surfaces were higher than that on the EDM surface(P<.05).

Effect of Electron-beam Irradiaton on the Artificial Bone Substitutes Composed of Hydroxyapatite and Tricalcium Phosphate Mixtures with Type I Collagen (수산화인회석과 인산삼칼슘 및 1형 콜라젠 혼합골의 전자빔 조사 효과)

  • Park, Jung Min;Kim, Soung Min;Kim, Min Keun;Park, Young Wook;Myoung, Hoon;Lee, Byung Cheol;Lee, Jong Ho;Lee, Suk Keun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.35 no.1
    • /
    • pp.38-50
    • /
    • 2013
  • Purpose: The aim of this study is to evaluate the effect and potential of electron beam (E-beam) irradiation treatment to the synthetic bony mixtures composed of hydroxyapatite (HA; Bongros$^{(R)}$, Bio@ Co., Korea) and tricalcium phosphate (${\beta}$-TCP, Sigma-Aldrich Co., USA), mixed at various ratios and of type I collagen (Rat tail, BD Biosciences Co., Sweden) as an organic matrix. Methods: We used 1.0~2.0 MeV linear accelerator and 2.0 MeV superconductive linear accelerator (power 100 KW, pressure 115 kPa, temperature $-30{\sim}120^{\circ}C$, sensor sensitivity 0.1~1.2 mV/kPa, generating power sensitivity 44.75 mV/kPa, supply voltage $5{\pm}0.25$ V) with different irradiation dose, such as 1, 30 and 60 kGy. Structural changes in this synthetic bone material were studied in vitro, by scanning electron microscopy (SEM), elementary analysis and field emission scanning electron microscope (FE-SEM), attenuated total reflection (ATR), and electron spectroscopy for chemical analysis (ESCA). Results: The large particular size of HA was changed after E-beam irradiation, to which small particle of TCP was engaged with organic collagen components in SEM findings. Conclusion: The important new in vitro data to be applicable as the substitutes of artificial bone materials in dental and medical fields will be able to be summarized.

Comparison of the Proliferation pattern of Cultured Rat Calvaria Cell on the Resorbable Barrier Membrane (흡수성 차폐막에 배양된 구개관세포의 증식양상의 비교)

  • Lee, Chang-Hoon;Lee, Man-Sup;Kwon, Young-Hyuk;Park, Joon-Bong;Herr, Yeek
    • Journal of Periodontal and Implant Science
    • /
    • v.33 no.2
    • /
    • pp.193-213
    • /
    • 2003
  • The purpose of this study is to evaluate the phenomenon of attachment and spreading of the cultured rat calvarial cell inoculated on their surface of different kinds of biodegradable membrane which had been used on tissue regeneration on periodontal defects by using scanning electron microscope. In this experiment 30 Sprague-Dawley male rats (mean BW 150gm) were used to harvest abundant number of cell in the short period. The rats were sacrificed by decapitatioan to obtain the calvaria for bone cell culture. Calvarial cells were cultured with Dulbecco's Modified Essential Medium contained with 10% Fetal Bovine Serum under the conventional conditions. Biodegradable barrier membrane were collected with collagen type, and were divided into 3 different kind of surface such as scattered, polarized and fine-net type as their surface texture. Microcover plate which usually used for cell culture was used as control for smooth surface. All the membrane were seeded with cultured calvarial cell on their surface. The number of cell inoculated on the membrane were $1{\times}10^6$ Cells/ml. After the culture as designed time, all the membrane were washed with 0.1 M Phosphate Buffered saline and fuxed with 2.5% Glutaraldehyde. And all specimen were treated with $OsO_4$, and Tannic acid before drying the cell for coating the cell with gold. Scanning Electron Microscope was used to observation. The following results were obtained. I. During the whole period of experiment, the phenomenon of cell attachment and spreading were revealed similar pattern to compare with smooth surface culture plate and ordinary culture dish. 2. The shape of cell attachment and spreading on the surface of barrier membrane were observed no remarked difference pattern between smooth surface culture plate and ordinary culture dish. 3. The cytoplasmic process of cultured calvaria cell extent to the deep portion of barrier membrane like as their own proper shape. 4. There were no remarkable relationships between the degree of cultured cell spreading and surface structure of barrier membrane. 5. Slight starified layer of cultured calvaria cell were observed on the scattered type of resorbable membrane, Conclusively, this study thus suggest that cultured bone cell inoculated onto the biodegradable barrier membrane may have an important role of carrier for many cell which could be used as new tissue regeneration, and those tissue engeering technique may become an new method in the approach to the repair of bone defects.

A Light and Scanning Electron Microscopic Study on the Implant of Tooth Ash-Porcelain Mixture (치아회분(齒牙灰粉)과 도재(陶材) 복합(複合) 매식체(埋植體)에 관(關)한 광학현미경(光學顯微鏡) 급(及) 주사전자현미경적(走査電子顯微鏡的) 연구(硏究))

  • Cho, Young-Hak
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.22 no.1
    • /
    • pp.33-50
    • /
    • 1984
  • The purpose of this study was to investigate whether the ashed tooth powder is utilized as an alternative material of the implant to recovery the bony defect. For this purpose its biocompatibility was evaluated comparing to the synthetic calcium phosphate compounds, such as Syntograft and Calcitite, as well as the vacuum firing porcelain (Ceramco Inc.) which is anticipated to use as a matrix to aid sintering. Bony defects to exposure the bone marrow, $3{\times}5$ mm in size, were created in the right and left tibias of fifteen rabbits, and then the ashed tooth powder at $950^{\circ}C$, the porcelain powder, Syhtograft and Calcitite were inserted in the defects of twelve rabbits of the experimental group and the blood clot only was filled in the defects of three rabbits of the control group. The experimental and control rabbits were sacrificed at 1st, 2nd 3rd week after implantation and the histologic examination was performed. The ashed tooth powder in order to make the needed form of the implant was molded using the cylindrical mold 1 cm high, 1 cm in diameter under the pressure of $1000kg/cm^2$ and the ashed tooth powder was sintered at $1100^{\circ}C$ for 1 hour and the mixture of the porcelain powder and the ashed tooth powder at the weight ratio of 7:3, 6:4, 5:5, 4:6 were molded in the same manner and were sintered at $925^{\circ}C$. From this sintered material, square shaped implants were prepared in the dimension of $2{\times}4{\times}6mm$. The prepared implants were surgically placed in the subperiosteum of lateral surfaces of the right and left mandibular bodies. The dogs were sacrificed at 4 weeks, and then the specimens were examined using the light and scanning electron microscopes. The results of this study were obtained as follows: 1. Any inflammatory response was not noted after implanting of the ashed tooth powder, Syntograft, Calcitite and the porcelain powder during the whole experimental period after implantation. 2. Induction of the new bone formation was significantly shown in the ashed tooth powder, Syntograft and Calcitite. 3. The more the porcelain powder was contained in the implants, the more the porosity was and the bigger the pore size was under the scanning electron microscope. And there was ingrowing of the fibrous connective and the osteoid tissue. 4. The osteoid tissues were found to be directly fused to the implant of the ashed tooth powder, and the mixture implant of the porcelain powder and the ashed tooth powder at the weight ratio of 4:6 under the light and scanning electron microscopes.

  • PDF

Comparison of removal torques between laser-etched and modified sandblasted acid-etched Ti implant surfaces in rabbit tibias

  • Park, Kyung-Soon;Al Awamleh, Abdel Ghani Ibrahim;Cho, Sung-Am
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.1
    • /
    • pp.73-78
    • /
    • 2018
  • PURPOSE. The purpose of this study was to analyze the effects of two different implant surface treatments on initial bone connection by comparing the Removal Torque Values (RTQs) at 7 and 10 days after chemically modified, sandblasted, large-grit and acid-etched (modSLA), and Laser-etched (LE) Ti implant placements. MATERIALS AND METHODS. Twenty modSLA and 20 LE implants were installed on the left and right tibias of 20 adult rabbits. RTQs were measured after 7 and 10 days in 10 rabbits each. Scanning electron microscope (SEM) photographs of the two implants were observed by using Quanta FEG 650 from the FEI company (Hillsboro, OR, USA). Analyses of surface elements and components were conducted using energy dispersive spectroscopy (EDS, Horiba, Kyoto, Japan). RESULTS. The mean RTQs were $12.29{\pm}0.830$ and $12.19{\pm}0.713$ Ncm after 7 days (P=.928) and $16.47{\pm}1.324$ and $16.17{\pm}1.165$ Ncm after 10 days (P=.867) for LE and modSLA, respectively, indicating no significant inter-group differences. Pore sizes in the LE were $40{\mu}m$ and consisted of numerous small pores, whereas pore sizes in the modSLA were $5{\mu}m$. In the EDS analysis, Ti, O, and C were the only three elements found in the LE surfaces. Na, Ca, Cl, and K were also observed in modSLA, in addition to Ti, O, and C. CONCLUSION. The implants showed no significant difference in biomechanical bond strength to bone in early-stage osseointegration. LE implant can be considered an excellent surface treatment method in addition to the modSLA implant and can be applied to the early loading of the prosthesis clinically.

A Study on Fabrication of 3D Dual Pore Scaffold by Fused Deposition Modeling and Salt-Leaching Method (열 용해 적층법과 염 침출법을 이용한 3 차원 이중 공 인공지지체 제작에 관한 연구)

  • Shim, Hae-Ri;Kim, Jong Young
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.12
    • /
    • pp.1229-1235
    • /
    • 2015
  • Scaffold fabrication technology using a 3D printer was developed for damaged bone tissue regeneration. A scaffold for bone tissue regeneration application should be biocompatible, biodegradable, and have an adequate mechanical strength. Moreover, the scaffold should have pores of satisfactory quantity and interconnection. In this study, we used the polymer deposition system (PDS) based on fused deposition modeling (FDM) to fabricate a 3D scaffold. The materials used were polycaprolactone (PCL) and alginic acid sodium salt (sodium alginate, SA). The salt-leaching method was used to fabricate dual pores on the 3D scaffold. The 3D scaffold with dual pores was observed using SEM-EDS (scanning electron microscope-energy dispersive spectroscopy) and evaluated through in-vitro tests using MG63 cells.

Extraction of Computer Image Analysis Information by Desk Top Computer from Beef Carcass Cross Sections

  • Karnuah, A.B.;Moriya, K.;Sasaki, Y.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.12 no.8
    • /
    • pp.1171-1176
    • /
    • 1999
  • The precision and reliability of the Computer Image Analysis technique using a desk top computer for extracting information from carcass cross section scans was evaluated by the repeatability (R) and coefficient of variation (CV) for error variance. The 6th and 7th ribs cross section of carcasses from 55 fattened Japanese Black steers were used. The image analysis was conducted using a desk top computer (Macintosh-Apple Vision 1710 Display) connected to a scanner and an image capture camera. Two software applications, Adobe Photoshop and Mac Scope were used interchangeably. The information extracted and measured were individual muscle area, circumference length, long and short axes lengths, muscle direction; distance between any two muscle centers of gravity; cross section total area, lean, fat, and bone. The information was extracted after the processes of scanning, digitization, masking, muscle separation, and binarization. When using the Computer Image Analysis technique by desk top computer, proper digitization and selection of scanning resolution are very important in order to obtain accurate information. The R-values for muscle area, circumference, long and axes lengths, and direction ranged from 0.95 to 0.99, whereas those of the distance between any two muscle centers of gravity ranged from 0.96 to 0.99, respectively. For the cross section total area, lean, fat, and bone it ranged from 0.83 to 0.99. Excellent repeatability measurements were observed for muscle direction and distance between any two muscle centers of gravity. The results indicate that the Computer Image Analysis technique using a desk top computer for extracting information from carcass cross section is reliable and has high precision.

Effect of Variable Scanning Protocols on the Pre-implant Site Evaluation of the Mandible in Reformatted Computed Tomography (영상재구성 전산화 단층촬영에서 촬영조건의 변화가 하악골 술전 임플란트 부위 평가에 미치는 영향)

  • Kim Kee-Deog;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.1
    • /
    • pp.21-32
    • /
    • 1999
  • Purpose: To evaluate the effect of variable scanning protocols of computed tomography for evaluation of pre-implant site of the mandible through the comparison of the reformatted cross-sectional images of helical CT scans obtained with various imaging parameters versus those of conventional CT scans. Materials and Methods: A dry mandible was imaged using conventional nonoverlapped CT scans with 1 mm slice thickness and helical CT scans with 1 mm slice thickness and pitches of 1.0, 1.5. 2.0, 2.5 and 3.0. All helical images were reconstructed at reconstruction interval of 1 mm. DentaScan reformatted images were obtained to allow standardized visualization of cross-sectional images of the mandible. The reformatted images were reviewed and measured separately by 4 dental radiologists. The image qualities of continuity of cortical outline. trabecular bone structure and visibility of the mandibular canal were evaluated and the distance between anatomic structures were measured by 4 dental radiologists. Results: On image qualities of continuity of cortical outline. trabecular bone structure and visibility of the mandibular canal and in horizontal measurement. there was no statistically significant difference among conventional and helical scans with pitches of 1.0. 1.5 and 2.0. In vertical measurement. there was no statistically significant difference among the conventional and all imaging parameters of helical CT scans with pitches of 1.0, 1.5, 2.0, 2.5 and 3.0. Conclusion: The images of helical CT scans with 1 mm slice thickness and pitches of 1.0, 1.5 and 2.0 are as good as those of conventional CT scans with 1 mm slice thickness for evaluation of predental implant site of the mandible. Considering the radiation dose and patient comfort, helical CT scans with 1 mm slice thickness and pitch of 2.0 is recommended for evaluation of pre-implant site of the mandible.

  • PDF

Comparative study on the physicochemical properties and cytocompatibility of microporous biphasic calcium phosphate ceramics as a bone graft substitute (미세다공성 Biphasic calcium phosphate ceramics의 골이식 대체재로서의 기본특성에 대한 비교연구)

  • Park, Kwang-Bum;Park, Jin-Woo;Ahn, Hyun-Uk;Yang, Dong-Jun;Choi, Seok-Kyu;Jang, II-Sung;Yeo, Shin-Il;Suh, Jo-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.4
    • /
    • pp.797-808
    • /
    • 2006
  • Objective : The purpose of this study was to evaluate the physicochemical properties and cytocompatibility of microporous, spherical biphasic calcium phosphate(BCP) ceramics with a 60/40 $hydroxyapatite/{\beta}$ -tricalcium phosphate weight ratio for application as a bone graft substitute. Materials and Methods : Microporous, spherical BCP granules(MGSB) were prepared and their basic characteristics were compared with commercially available BCP(MBCP; Biomatlante, France) and deproteinized bovine bone mineral(Bio-Oss; GBistlich-Pharma, Switzerland, BBP; Oscotec. Korea), Their physicochemical properties were evaluated by scanning electron microscopy, X-ray diffractometry, Fourier-transform infrared spectroscopy, inductively coupled plasma atomic emission spectrometer, and Brunauer-Emmett-Teller method. Cell viability and proliferation of MC3T3-El cells on different graft materials were evaluated. Results : MGSB granules showed a chemical composition and crystallinity similar with those in MBCP, they showed surface structure characteristic of three dimensionally, well-interconnected micropores. The results of MTT assay showed increases in cell viablity with increasing incubation times. At 4d of incubation, MGSB, MBCP and BBP showed similar values in optical density, but Bio-Oss exhibited significantly lower optical density compared to other bone substitutes(p <0,05). MGSB showed significantly greater cell number compared to other bone substitutes at 3, 5, and 7d of incubation(p <0,05), which were similar with those in polystyrene culture plates. Conclusion: These results indicated the suitable physicochemical properties of MGSB granules for application as an effective bone graft substitute. which provided compatible environment for osteoblast cell growth. However, further detailed studies are needed to confirm its biological effects on bone formation in vivo.