• Title/Summary/Keyword: Bone implant

Search Result 2,314, Processing Time 0.023 seconds

The influence of bone graft procedures on primary stability and bone change of implants placed in fresh extraction sockets

  • Jun, Sang Ho;Park, Chang-Joo;Hwang, Suk-Hyun;Lee, Youn Ki;Zhou, Cong;Jang, Hyon-Seok;Ryu, Jae-Jun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.40
    • /
    • pp.8.1-8.6
    • /
    • 2018
  • Background: This study was to evaluate the effect of bone graft procedure on the primary stability of implants installed in fresh sockets and assess the vertical alteration of peri-implant bone radiographically. Methods: Twenty-three implants were inserted in 18 patients immediately after tooth extraction. The horizontal gap between the implant and bony walls of the extraction socket was grafted with xenografts. The implant stability before and after graft procedure was measured by Osstell Mentor as implant stability quotient before bone graft (ISQ bbg) and implant stability quotient after bone graft (ISQ abg). Peri-apical radiographs were taken to measure peri-implant bone change immediately after implant surgery and 12 months after implant placement. Data were analyzed by independent t test; the relationships between stability parameters (insertion torque value (ITV), ISQ abg, and ISQ bbg) and peri-implant bone changes were analyzed according to Pearson correlation coefficients. Results: The increase of ISQ in low primary stability group (LPSG) was 6.87 ± 3.62, which was significantly higher than the increase in high primary stability group (HPSG). A significant correlation between ITV and ISQ bbg (R = 0.606, P = 0.002) was found; however, age and peri-implant bone change were not found significantly related to implant stability parameters. It was presented that there were no significant peri-implant bone changes at 1 year after bone graft surgery. Conclusions: Bone graft procedure is beneficial for increasing the primary stability of immediately placed implants, especially when the ISQ of implants is below 65 and that bone grafts have some effects on peri-implant bone maintenance.

The effect of undersizing and tapping on bone to implant contact and implant primary stability: A histomorphometric study on bovine ribs

  • Di Stefano, Danilo Alessio;Perrotti, Vittoria;Greco, Gian Battista;Cappucci, Claudia;Arosio, Paolo;Piattelli, Adriano;Iezzi, Giovanna
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.3
    • /
    • pp.227-235
    • /
    • 2018
  • PURPOSE. Implant site preparation may be adjusted to achieve the maximum possible primary stability. The aim of this investigation was to study the relation among bone-to-implant contact at insertion, bone density, and implant primary stability intra-operatively measured by a torque-measuring implant motor, when implant sites were undersized or tapped. MATERIALS AND METHODS. Undersized (n=14), standard (n=13), and tapped (n=13) implant sites were prepared on 9 segments of bovine ribs. After measuring bone density using the implant motor, 40 implants were placed, and their primary stability assessed by measuring the integral of the torque-depth insertion curve. Bovine ribs were then processed histologically, the bone-to-implant contact measured and statistically correlated to bone density and the integral. RESULTS. Bone-to-implant contact and the integral of the torque-depth curve were significantly greater for undersized sites than tapped sites. Moreover, a correlation between bone to implant contact, the integral and bone density was found under all preparation conditions. The slope of the bone-to-implant/density and integral/density lines was significantly greater for undersized sites, while those corresponding to standard prepared and tapped sites did not differ significantly. CONCLUSION. The integral of the torque-depth curve provided reliable information about bone-to-implant contact and primary implant stability even in tapped or undersized sites. The linear relations found among the parameters suggests a connection between extent and modality of undersizing and the corresponding increase of the integral and, consequently, of primary stability. These results might help the physician determine the extent of undersizing needed to achieve the proper implant primary stability, according to the planned loading protocol.

Implant survival and risk factor analysis in regenerated bone: results from a 5-year retrospective study

  • Hong, Ji-Youn;Shin, Eun-Young;Herr, Yeek;Chung, Jong-Hyuk;Lim, Hyun-Chang;Shin, Seung-Il
    • Journal of Periodontal and Implant Science
    • /
    • v.50 no.6
    • /
    • pp.379-391
    • /
    • 2020
  • Purpose: The aims of this study were to evaluate the 5-year cumulative survival rate (CSR) of implants placed with guided bone regeneration (GBR) compared to implants placed in native bone, and to identify factors contributing to implant failure in regenerated bone. Methods: This retrospective cohort study included 240 patients who had implant placement either with a GBR procedure (regenerated bone group) or with pristine bone (native bone group). Data on demographic features (age, sex, smoking, and medical history), location of the implant, implant-specific features, and grafting procedures and materials were collected. The 5-year CSRs in both groups were estimated using Kaplan-Meier analysis. Risk factors for implant failure were analyzed with a Cox proportional hazards model. Results: In total, 264 implants in the native bone group and 133 implants in the regenerated bone group were analyzed. The 5-year CSRs were 96.4% in the regenerated bone group and 97.5% in the native bone group, which was not a significant difference. The multivariable analysis confirmed that bone status was not an independent risk factor for implant failure. However, smoking significantly increased the failure rate (hazard ratio, 10.7; P=0.002). Conclusions: The 5-year CSR of implants placed in regenerated bone using GBR was comparable to that of implants placed in native bone. Smoking significantly increased the risk of implant failure in both groups.

The effects of bone density and crestal cortical bone thickness on micromotion and peri-implant bone strain distribution in an immediately loaded implant: a nonlinear finite element analysis

  • Sugiura, Tsutomu;Yamamoto, Kazuhiko;Horita, Satoshi;Murakami, Kazuhiro;Tsutsumi, Sadami;Kirita, Tadaaki
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.3
    • /
    • pp.152-165
    • /
    • 2016
  • Purpose: This study investigated the effects of bone density and crestal cortical bone thickness at the implant-placement site on micromotion (relative displacement between the implant and bone) and the peri-implant bone strain distribution under immediate-loading conditions. Methods: A three-dimensional finite element model of the posterior mandible with an implant was constructed. Various bone parameters were simulated, including low or high cancellous bone density, low or high crestal cortical bone density, and crestal cortical bone thicknesses ranging from 0.5 to 2.5 mm. Delayed- and immediate-loading conditions were simulated. A buccolingual oblique load of 200 N was applied to the top of the abutment. Results: The maximum extent of micromotion was approximately $100{\mu}m$ in the low-density cancellous bone models, whereas it was under $30{\mu}m$ in the high-density cancellous bone models. Crestal cortical bone thickness significantly affected the maximum micromotion in the low-density cancellous bone models. The minimum principal strain in the peri-implant cortical bone was affected by the density of the crestal cortical bone and cancellous bone to the same degree for both delayed and immediate loading. In the low-density cancellous bone models under immediate loading, the minimum principal strain in the peri-implant cortical bone decreased with an increase in crestal cortical bone thickness. Conclusions: Cancellous bone density may be a critical factor for avoiding excessive micromotion in immediately loaded implants. Crestal cortical bone thickness significantly affected the maximum extent of micromotion and peri-implant bone strain in simulations of low-density cancellous bone under immediate loading.

Primary stability of implants with peri-implant bone defects of various widths: an in vitro investigation

  • Yim, Hyun-jin;Lim, Hyun-Chang;Hong, Ji-Youn;Shin, Seung-Il;Chung, Jong-Hyuk;Herr, Yeek;Shin, Seung-Yun
    • Journal of Periodontal and Implant Science
    • /
    • v.49 no.1
    • /
    • pp.39-46
    • /
    • 2019
  • Purpose: This study aimed to evaluate the effects of i) the extent of peri-implant bone defects and ii) the application of bone cement on implant stability with respect to the measurement direction. Methods: In 10 bovine rib bones, 4 implant osteotomies with peri-implant bone defects of various widths were prepared: i) no defect (D0), ii) a 2-mm-wide defect (D2), iii) a 4-mm-wide defect (D4), and iv) a 8-mm-wide defect (D8). The height of all defects was 10 mm. Implant stability quotient (ISQ) values and Periotest values (PTVs) were measured after implant placement and bone cement application. Results: With increasing defect width, decreased ISQs and increased PTVs were observed. Statistically significant differences were found between groups D0 and D8, D0 and D4, and D2 and D8. Prior to bone cement application, inconsistent PTVs were found in group D8 depending on the measurement direction. Bone cement increased the implant stability. Conclusion: Peri-implant bone deficits measuring around 50% of the implant surface compromised implant stability. Clinically, PTVs should be cautiously interpreted in implants with large peri-implant defects due to inconsistent recordings with respect to the measurement direction.

Influence of soft tissue and bone thickness on the dimensional change of peri-implant soft tissues;A clinical follow-up study (연조직 및 골 두께가 임플란트 주위 연조직 형태에 끼치는 영향에 관한 임상추적연구)

  • Chang, Moon-Taek
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.1
    • /
    • pp.187-197
    • /
    • 2005
  • The aim of this study was to investigate the influence of peri-implant soft tissue and bone thickness on the early dimensional change of peri-implant soft tissue. Seventy-seven non-submerged implants of 39 patients which had been loaded more than 6 months were selected for the study. Following clinical parameters were measured; bucco-lingual bone width of the alveolar bone for implant placement before implant surgery; distance between implant shoulder and the first bone/implant contact at the surgery; presence of plaque, probing depth, bleeding on probing, width of keratinized mucosa, mucosa thickness, distance between implant shoulder and peri-implant mucosa, crown margin location at follow-up examination. The results showed that distance between implant shoulder and peri-implant mucosa (DIM) was correlated with probing depth and width of keratinized mucosa (p < 0.05). In addition, mucosa thickness was also correlated with probing depth (p<0.05). However, the bone width of alveolar bone and soft tissue thickness were not found to be correlated with DIM. It is important to understand the meaning of peri-implant tissue dimension in relation to dimensional changes of peri-implant soft tissue which designates appearance of implant-supported restorations. Future study is needed to elucidate the significance of the buccal bone thickness and soft tissue thickness with respect to the change of peri-implant soft tissue margin with the use of an instrument capable of measuring buccal bone thickness directly.

DENTAL IMPLANT TREATMENT WITH ILIAC BONE GRAFT VIA TWO-STAGE APPROACH FOR AVULSED ALVEOLAR BONE DEFECTS; CASE REPORT (외상성 치조골 상실 후 장골 이식을 동반한 이회법 임플란트 치료; 증례보고)

  • Choi, Young-Jun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.4
    • /
    • pp.386-390
    • /
    • 2007
  • This is about the case of loss of multiple teeth and alveolar bone caused by trauma, which needed alveolar bone augmentation before implant treatment. Alveolar bone was reconstructed using iliac bone graft, and thereafter first implant surgery was followed by consolidation period of 3 months. Iliac bone resorption was observed at the time of implant placement. And that resorption was more in the horizontal dimension than in the vertical. We conclude that additional treatment planning(e.g. using alveolar distraction osteogenesis or tissue expander) should be considered besides bone graft for vertical alveolar bone augmentation. For both maxilla and mandible, prosthodontic treatment was carried out $4{\sim}5$ months after implant placement. To compensate alveolar bone deficiency, partial hybrid overdenture on maxilla and implant-supported fixed bridge on mandible were fabricated, and the total treatment was finished.

Influence of the adjacent periodontium and inter-implant distance on bone resorption around non-submerged implants;A retrospective clinical and radiographic study (인접 치주조직과 임플란트간 거리가 임플란트 주변 골흡수에 미치는 영향;임상 및 방사선사진 검사에 의한 후향적 연구)

  • Chang, Moon-Taek
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.3
    • /
    • pp.535-541
    • /
    • 2004
  • The aims of the present study are firstly to investigate the amount of bone loss around non-submerged implants placed in the posterior region and secondly to investigate the relationship between inter-implant and implant-tooth distance and peri-implant bone loss. Thirty-one subjects with 60 implants were selected consecutively from the implant patient pool at the department of Chonbuk National University Hospital. To be included in the study subject, the implant should have been functioned more than 6 months after loading. Inter-implant and implant-tooth distance, distance between implant shoulder and the first bone contact with the implant(DIB) were measured from the scanning image of the radiograph of each implant. The result showed that; 1. inter-implant distance has a statistically significant relationship with DIB in Pearson correlation analysis. 2. the DIB at the implant facing surface of the implant was greater than that of tooth facing surface of the implant. Within limitation of this study, it is suggested to place an implant not too closely to adjacent implants, and the presence of a tooth adjacent to an implant may keep the level of tooth-facing surface of the implant. Further studies with a prospective design are needed to elucidate the relationship between bone changes and various dimensions around implants.

A comparative study on the initial stability of different implants placed above the bone level using resonance frequency analysis

  • Kang, In-Ho;Kim, Chang-Whe;Lim, Young-Jun;Kim, Myung-Joo
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.4
    • /
    • pp.190-195
    • /
    • 2011
  • PURPOSE. This study evaluated the initial stability of different implants placed above the bone level in different types of bone. MATERIALS AND METHODS. As described by Lekholm and Zarb, cortical layers of bovine bone specimens were trimmed to a thickness of 2 mm, 1 mm or totally removed to reproduce bone types II, III, and IV respectively. Three Implant system (Br${\aa}$nemark System$^{(R)}$ Mk III TiUnite$^{TM}$, Straumann Standard Implant SLA$^{(R)}$, and Astra Tech Microthread$^{TM}$-OsseoSpeed$^{TM}$) were tested. Control group implants were placed in level with the bone, while test group implants were placed 1, 2, 3, and 4 mm above the bone level. Initial stability was evaluated by resonance frequency analysis. Data was statistically analyzed by one-way analysis of variance in confidence level of 95%. The effective implant length and the Implant Stability Quotient (ISQ) were compared using simple linear regression analysis. RESULTS. In the control group, there was a significant difference in the ISQ values of the 3 implants in bone types III and IV (P<.05). The ISQ values of each implant decreased with increased effective implant length in all types of bone. In type II bone, the decrease in ISQ value per 1-mm increase in effective implant length of the Br${\aa}$nemark and Astra implants was less than that of the Straumann implant. In bone types III and IV, this value in the Astra implant was less than that in the other 2 implants. CONCLUSION. The initial stability was much affected by the implant design in bone types III, IV and the implant design such as the short pitch interval was beneficial to the initial stability of implants placed above the bone level.

The rate and stability of mandibular block bone graft in recent 5 years

  • Park, Jong-Cheol;Kim, Yun-Ho;Choi, Hong-Seok;Oh, Jong-Shik;Shin, Sang-Hun;Kim, Yong-Deok
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.39
    • /
    • pp.21.1-21.6
    • /
    • 2017
  • Background: The purposes of the present study were to compare implant stabilities of mandibular block bone graft and bovine bone graft and to evaluate influencing factors for implant stability in mandibular block bone (MBB) graft. Methods: This retrospective study investigated 1224 cases and 389 patients treated by one surgeon in the Department of Oral and Maxillofacial Surgery of Pusan National University Dental Hospital (Yangsan, Korea) between January 2010 and December 2014. Proportions that MBB graft cases constitute in all implant restoration cases and in all bone graft cases were measured. Implant stability quotient (ISQ) values were achieved by the same surgeon before loading. The average ISQ values of the experimental groups were compared. In addition, ISQ values of influencing factors, such as age, sex, implant size, and implant placement site, were compared within the MBB group using $Osstell^{TM}$ Mentor ($Osstell^{(R)}$, $G{\ddot{o}}teborg$, Sweden). Paired t test and ANOVA were conducted for statistical analysis with a significance level of 0.05. Results: Fifty-five percent of all implant restoration cases performed bone graft while MBB cases constituted 34% of all implant restoration cases and 61% of all bone graft cases. Comparing ISQ values according to bone graft materials, the MBB group manifested sufficient implant stability by presenting comparable ISQ value to that of the experimental group without bone graft. Among the reviewed factors, females, mandibular molar regions, and implants in larger diameter displayed greater implant stabilities. Conclusions: Satisfactory implant stability was accomplished upon administration of MBB graft. Within the limitation of this study, gender, implant site, and implant diameter were speculated to influence on implant stability in MBB graft.