• Title/Summary/Keyword: Bone healing

Search Result 1,028, Processing Time 0.03 seconds

Investigation of a pre-clinical mandibular bone notch defect model in miniature pigs: clinical computed tomography, micro-computed tomography, and histological evaluation

  • Carlisle, Patricia L.;Guda, Teja;Silliman, David T.;Lien, Wen;Hale, Robert G.;Baer, Pamela R. Brown
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.42 no.1
    • /
    • pp.20-30
    • /
    • 2016
  • Objectives: To validate a critical-size mandibular bone defect model in miniature pigs. Materials and Methods: Bilateral notch defects were produced in the mandible of dentally mature miniature pigs. The right mandibular defect remained untreated while the left defect received an autograft. Bone healing was evaluated by computed tomography (CT) at 4 and 16 weeks, and by micro-CT and non-decalcified histology at 16 weeks. Results: In both the untreated and autograft treated groups, mineralized tissue volume was reduced significantly at 4 weeks post-surgery, but was comparable to the pre-surgery levels after 16 weeks. After 16 weeks, CT analysis indicated that significantly greater bone was regenerated in the autograft treated defect than in the untreated defect (P=0.013). Regardless of the treatment, the cortical bone was superior to the defect remodeled over 16 weeks to compensate for the notch defect. Conclusion: The presence of considerable bone healing in both treated and untreated groups suggests that this model is inadequate as a critical-size defect. Despite healing and adaptation, the original bone geometry and quality of the pre-injured mandible was not obtained. On the other hand, this model is justified for evaluating accelerated healing and mitigating the bone remodeling response, which are both important considerations for dental implant restorations.

The healing effect of platelet-rich plasma on xenograft in peri-implant bone defects in rabbits

  • Peng, Wang;Kim, Il-kyu;Cho, Hyun-young;Seo, Ji-Hoon;Lee, Dong-Hwan;Jang, Jun-Min;Park, Seung-Hoon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.38
    • /
    • pp.16.1-16.9
    • /
    • 2016
  • Background: The association of biomaterial combined with repair factor-like platelet-rich plasma (PRP) has prospective values. Bovine-derived xenograft has been identified as an osteoconductive and biocompatible grafting material that provides osseointegration ability. PRP has become a valuable adjunctive agent to promote healing in a lot of dental and oral surgery procedures. However, there are controversies with respect to the regenerative capacity of PRP and the real benefits of its use in bone grafts. The purpose of this study was to assess the influence of PRP combined with xenograft for the repair of peri-implant bone defects. Methods: Twelve rabbits were used in this study, and the experimental surgery with implant installation was performed simultaneously. Autologous PRP was prepared before the surgical procedure. An intrabony defect (7.0 mm in diameter and 3.0 mm deep) was created in the tibia of each rabbit; then, 24 titanium dental implants (3.0 mm in diameter and 8.5 mm long) were inserted into these osteotomy sites. Thus, a standardized gap (4.0 mm) was established between the surrounding bony walls and the implant surface. The gaps were treated with either xenograft alone (control group) or xenograft combined with PRP (experimental group). After healing for 1, 2, 3, 4, 5, and 6 weeks, the rabbits were sacrificed with an overdose of KCl solution. Two rabbits were killed at each time, and the samples including dental implants and surrounding bone were collected and processed for histological analysis. Results: More newly formed bone and a better bone healing process were observed in control group. The histomorphometric analysis revealed that the mean percentage of bone-to-implant contact in the control group was significantly higher than that of the experimental group (25.23 vs. 8.16 %; P < 0.05, independent-simple t test, analysis of variance [ANOVA]). Conclusions: The results indicate that in the addition of PRP to bovine-derived xenograft in the repair of bone defects around the implant, PRP may delay peri-implant bone healing.

AN EXPERIMENTAL STUDY OF EFFECTS OF THE FIBRIN ADHESIVE ON BONE FORMATION PROCESS AFTER FREEZE DRIED DEMINERALIZED ALLOGENEIC BONE GRAFTS (냉동 건조 탈회 동종골 이식시 조직 접착제가 골 치유 과정에 미치는 영향에 관한 실험적 연구)

  • Kim, Chi-Kyeong;Kim, Soo-Nam;Min, Seung-Ki
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.17 no.4
    • /
    • pp.365-378
    • /
    • 1995
  • Allogeneic bone grafting has recently been used in oral and maxillofacial regions to restore the cosmetic and functional problem. There are several types of allogeneic bone grafts ; bone powder, bone chips, bone blocks. Empirically, it is thought to be better to combine the allogeneic bone chips to any type of tissue adhesive not to displace during packing and condensing. But, there are no reports about using tissue adhesive in allogeneic bone grafting. This experimental study is designed to investigate the effect of the fibrin adhesive on bone healing process after demineralized allogeneic bone grafting in 60 rats. In control groups (30 rats), routine demineralized allogeneic bone grafting were done in 7 ${\times}$ 7mm calvarial bone defects which were drilled intentioally. And we used the fibrin adhesive for holding the bone particle in experimental groups (30 rats). Each experimental specimen was sacrified at 1, 2, 4, 6, 8 weeks postoperatively The results were as follows : 1. The degree of inflammatory cell infiltrations were more prominent in experimental than in control groups till 2 weeks. 2. Early fibroblast proliferation and new capillary proliferation were uncorporated around graft sites in the experimental groups later than in control groups at early stages. 3. Osteoblastic activity in control group was more prominent at 2 weeks. 4. Osteoblastic activity in experimental groups was more prominent than in control group till 4 weeks. 5. New bone formation was more in control group than experimental group till 3 weeks, but similar appearance after that time. As above results, initial bone healing within 2 weeks were more processed in without adhesive group than with adhesive group. But above 4 weeks; similar bone healing were observed.

  • PDF

Dissolution behavior and early bone apposition of calcium phosphate-coated machined implants

  • Hwang, Ji-Wan;Lee, Eun-Ung;Lee, Jung-Seok;Jung, Ui-Won;Lee, In-Seop;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.43 no.6
    • /
    • pp.291-300
    • /
    • 2013
  • Purpose: Calcium phosphate (CaP)-coated implants promote osseointegration and survival rate. The aim of this study was to (1) analyze the dissolution behavior of the residual CaP particles of removed implants and (2) evaluate bone apposition of CaP-coated machined surface implants at the early healing phase. Methods: Mandibular premolars were extracted from five dogs. After eight weeks, the implants were placed according to drilling protocols: a nonmobile implant (NI) group and rotational implant (RI) group. For CaP dissolution behavior analysis, 8 implants were removed after 0, 1, 2, and 4 weeks. The surface morphology and deposition of the coatings were observed. For bone apposition analysis, block sections were obtained after 1-, 2-, and 4-week healing periods and the specimens were analyzed. Results: Calcium and phosphorus were detected in the implants that were removed immediately after insertion, and the other implants were composed mainly of titanium. There were no notable differences between the NI and RI groups in terms of the healing process. The bone-to-implant contact and bone density in the RI group showed a remarkable increase after 2 weeks of healing. Conclusions: It can be speculated that the CaP coating dissolves early in the healing phase and chemically induces early bone formation regardless of the primary stability.

Effectiveness of Autogenous Tooth Bone Graft Combined with Growth Factor: Prospective Cohort Study

  • Ahn, Kyo-Jin;Kim, Young-Kyun;Yun, Pil-Young;Lee, Bu-Kyu
    • Journal of Korean Dental Science
    • /
    • v.6 no.2
    • /
    • pp.50-57
    • /
    • 2013
  • Purpose: Autogenous tooth bone graft is proven to be efficient. We evaluated the bone healing effect and clinical capabilities of autogenous tooth bone materials as a scaffold when growth factor is used together with this material. Materials and Methods: Subjects were those who needed implant placement and bone graft because of missing tooth or alveolar bone defect and who kept their autogenous tooth or needed extraction of other tooth. Group I included autogenous tooth bone graft with growth factor, whereas Group II had only autogenous tooth bone graft. We investigated the bone healing state through computed tomography taken just before surgery and 3 to 4 months after surgery to evaluate the effectiveness of bone graft. Group I had 9 patients, whereas Group II had 5 patients. We compared the pre- and post-operative increase of the Hounsfield unit and bone height by analyzing the computed tomography images. Result: Sinus bone grafts numbered 8 cases, and vertical ridge augmentation was performed together with 3 cases of these. Vertical ridge augmentation was performed in 2 cases, and horizontal ridge augmentation in 1 case alone. Socket graft was done in 3 cases. The post-operative mean value of the Hounsfield unit was 960 in Group I and 836.7 in Group II, but the increase was almost similar, i.e., 636.9 in Group I and 634.7 in Group II on the average. Increase of bone height was 7.6 mm in Group I and 11.1 mm in Group II on the average. This difference was attributable to the fact that most of the cases were sinus bone graft in Group II. Conclusion: In this study, we suggest the possibility of autogenous tooth bone graft materials as a scaffold besides their bone healing ability.

Open healing of contained and non-contained extraction sockets covered with a ribose cross-linked collagen membrane: a pilot study

  • Friedmann, Anton;Meskeleviciene, Viktorija;Yildiz, Mehmet Selim;Gotz, Werner;Park, Jung-Chul;Fischer, Kai R.
    • Journal of Periodontal and Implant Science
    • /
    • v.50 no.6
    • /
    • pp.406-417
    • /
    • 2020
  • Purpose: This study investigated whether the placement of ribose cross-linked collagen (RCLC) membranes without primary soft tissue closure predictably resulted in sufficient alveolar ridge preservation in contained and non-contained extraction sockets. Methods: Membranes were positioned across extraction sockets, undermining full-thickness flaps, and the gingival margins were fixed by double-interrupted sutures without crossed horizontal mattress sutures for 1 week. In non-contained sockets, a bone substitute was used to support the membrane within the bony envelope. Radiographs and clinical images obtained 4 months later were analyzed by ImageJ software using non-parametric tests. Results: In 18 patients, 20 extraction sockets healed uneventfully and all sites received standard-diameter implants (4.1, 4.8, or 5.0 mm) without additional bone augmentation. Soft tissues and the muco-gingival border were well maintained. A retrospective analysis of X-rays and clinical photographs showed non-significant shrinkage in the vertical and horizontal dimensions (P=0.575 and P=0.444, respectively). The new bone contained vital bone cells embedded in mineralized tissues. Conclusions: Within the limitations of this pilot study, open healing of RCLC membranes may result in sufficient bone volume for implant placement without additional bone augmentation in contained and non-contained extraction sockets.

Prospective randomized clinical trial of hydrophilic tapered implant placement at maxillary posterior area: 6 weeks and 12 weeks loading

  • Kim, Seong-Beom;Yun, Pil-Young;Kim, Sang-Yun;Yi, Yang-Jin;Kim, Ji-Yun;Kim, Young-Kyun
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.5
    • /
    • pp.396-403
    • /
    • 2016
  • PURPOSE. Early loading of implant can be determined by excellent primary stability and characteristic of implant surface. The implant system with recently improved surface can have load application 4-6 weeks after installing in maxilla and mandible. This study evaluated the effect of healing period to the stability of hydrophilic tapered-type implant at maxillary posterior area. MATERIALS AND METHODS. This study included 30 patients treated by hydrophilic tapered-type implants (total 41 implants at maxilla) and classified by two groups depending on healing period. Group 1 (11 patients, 15 implants) was a control group and the healing period was 12 weeks, and Group 2 (19 patients, 26 implants) was test group and the healing period was 6 weeks. Immediately after implant placement, at the first impression taking, implant stability was measured using Osstell Mentor. The patients also took periapical radiographs after restoration delivery, 12 months after restoration and final followup period. The marginal bone loss around the implants was measured using the periapical radiographs. RESULTS. All implants were survived and success rate was 97.56%. The marginal bone loss was less than 1mm after 1 year postoperatively except the one implant. The stabilities of the implants were not correlated with age, healing period until loading, insertion torque (IT), the diameter of fixture and the location of implant. Only the quality of bone in group 2 (6 week) was correlated with the stability of implant. CONCLUSION. Healing period of 6 weeks can make the similar clinical prognosis of implants to that of healing period of 12 weeks if bone quality is carefully considered in case of early loading.

THE HISTOLOGIC STUDY OF BONE HEALING AFTER HORIZONTAL RIDGE AUGMENTATION USING AUTO BLOCK BONE GRAFT (자가골 블럭 이식을 이용한 수평골 증강술시 이식골의 치유)

  • Oh, Jae-Kwen;Choi, Byung-Jun;Lee, Baek-Soo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.3
    • /
    • pp.207-215
    • /
    • 2009
  • Purpose: The aim of the present study is to evaluate the long term bone healing after horizontal ridge augmentation using auto block bone graft for implant installation timing. Materials and Methods: Five Beagle dogs(which were 14 months old and weighted approximately 10kg). In surgery 1(extraction & bone defect), premolars(P2, P3,P4) were extracted and the buccal bone plate was removed to create a horizontally defected ridge. After three months healing, in surgery 2(ridge augmentation). Auto block bone grafts from the mandibular ramus were used in filling the bone defects were fixed with stabilizing screws. The following fluorochrome labels were given intravenously to the beagle dogs: oxytetracycline 1week after the surgery, alizarin red 4 weeks after the surgery, calcein blue 8 weeks after the surgery. The tissue samples were obtained from the sacrificed dogs of 1, 4, 8, 12, 16 weeks after the surgery. Non-decalcified sections were prepared by resin embedding and microsection to find thickness of $10{\mu}m$ for the histologic examination and analysis. Results: 1. We could achieve the successful reconstruction of the horizontal bone defect by auto block bone graft. The grafted bone block remained stable morohologically after 16 weeks of the surgery. 2. In the histologic view. We observed osteoid tissue from the sample $4^{th}$ week sample and active capillary reconstruction in the grafted bone from the $12^{th}$ week sample. Healing procedures of auto bone grafts were compared to that of the host bone. 3. Bone mineralization could be detected from the $8^{th}$ week sample. 4. Fluorochrome labeling showed active bony changes and formation at the interface of the host bone and the block graft mainly. Bony activation in the grafted bone could be seen from the $4^{th}$ week samples. Conclusions: Active bone formation and remodeling between the grafted bone and host bone can be seen through the revascularization. After the perfect adhesion to host bone, Timing of successful implant installation can be detected through the ideal ridge formation by horizontal ridge augmentation.

Spontaneous bone regeneration in resected non-continuous mandible due to medication-related osteonecrosis of the jaw

  • Esen, Alparslan;Gurses, Gokhan;Akkulah, Sebne
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.47 no.6
    • /
    • pp.465-470
    • /
    • 2021
  • Few cases of spontaneous bone regeneration after extensive resection of the jaw bone have been reported, but it is more common in young adults or children. In this case, we report spontaneous bone healing in a 73-year-old female patient. On radiological examination, necrotic regions were seen in the right mandible. She was diagnosed with medication-related osteonecrosis of the jaw due to previous bisphosphonate use. After segmental resection, stabilization achieved using a reconstruction plate. The periosteum was preserved during the procedure. Twelve months later, panoramic radiography was taken and bone formation was seen both horizontally and vertically around the plate. If the periosteum is preserved and stabilization is achieved after resection in benign lesions, the bone may regenerate spontaneously regardless of age. Therefore, instead of simultaneous autogenous bone application, such patients may be followed to determine whether spontaneous bone healing will occur. This should improve patient comfort and reduce surgical cost.

Healing of the Bone around Hydroxyapatite-Coated Implants without Primary Bone Contact (초기 골 접촉이 없는 수산화 인회석 피복 임프란트 주위 골의 치유)

  • Cho, Hyung-Soo;Shin, Kwang-Yong;Kim, Heung-Joong;Park, Joo-Cheol;Han, Kyung-Yoon;Kim, Byung-Ock
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.2
    • /
    • pp.415-433
    • /
    • 1999
  • Implant stability is the key to long-term successful outcome for osseointegrated implants. To evaluate the initial healing response of bone around HA-coated implants without primary bone contact. 21 HA-coated thread type implants(STERI-OSS?) were placed in the femurs of 5 mongrel dogs, about 1-year old. Implants, 8 mm in length and 3.8mm(experimental 1group), 5.0mm(experimental 2group) and 6.0mm(control group) in diameter, were inserted after 3 holes of 6.0mm in diameter and 10mm in depth were prepared in the surgical sites each dog. Implants were supported by only nonresorbable membrane($Teflon^{(R)}$), in order to prevent the ingrowth of upper soft tissue into the gap between bone and implant, and to maintain each implant to be positioned in the center of the drilled hole. 9 implants with different diameters were inserted in 3 dogs for histologic observation, and 12 implants were inserted in 2 dogs for mobility test and removal torque test. Fluorescent dyes were injected for the observation of new bone formation in order of $Terramycin^{(R)}$, Arizarin $Red^{(R)}$, and $Calcein^{(R)}$ at an interval of 2 weeks. 3 dogs were sacrificed for histologic observation at 4, 8, and 12-week after placement. Light microscopy and confocal laser scanning microscopy were used to qualitatively characterize the bone around HA-coated implant. 2 dogs were sacrificed for mobility test($Periotest^{(R)}$, Simens AG, Bensheim, Germany) and removal torque test($Autograph^{(R)}$ AGS-1000D series, Japan) at 8 and 12-week after placement The results were as follows: 1. Histologic observation showed that osseointegration occurred to both control and experimental groups as time lapse, but delayed bone healing was revealed in 3.8mm group (experimental 1group), compared to contrtol group and 5.0mm group (experimental 2group). 2. The mobility test showed that the experimental groups had no distinguishable movement during experimental periods of 8 and 12-week, and there was no difference in mobility depending on the gap between bone and implant, and time lapse. 3. The removal torque forces were increased depended on the gaps decreasing between bone and implant, and time lapse. The results suggest that HA-coated implant without primary bone contact, based on guided bone regeneration could obtain its stability in all experimental groups as time lapse, but bone healing was delayed in experimental group of 3.8mm. And the results suggested that studies on correlationship between mobility test and removal torque test for implant stability would be necessary.

  • PDF