DOI QR코드

DOI QR Code

Dissolution behavior and early bone apposition of calcium phosphate-coated machined implants

  • Hwang, Ji-Wan (Department of Periodontology, Research Institute for Periodontal Regeneration, Yonsei University College of Dentistry) ;
  • Lee, Eun-Ung (Department of Periodontology, Research Institute for Periodontal Regeneration, Yonsei University College of Dentistry) ;
  • Lee, Jung-Seok (Department of Periodontology, Research Institute for Periodontal Regeneration, Yonsei University College of Dentistry) ;
  • Jung, Ui-Won (Department of Periodontology, Research Institute for Periodontal Regeneration, Yonsei University College of Dentistry) ;
  • Lee, In-Seop (Institute of Physics & Applied Physics, Atomic-Scale Surface Science Research Center, Yonsei University) ;
  • Choi, Seong-Ho (Department of Periodontology, Research Institute for Periodontal Regeneration, Yonsei University College of Dentistry)
  • Received : 2013.07.09
  • Accepted : 2013.10.09
  • Published : 2013.12.31

Abstract

Purpose: Calcium phosphate (CaP)-coated implants promote osseointegration and survival rate. The aim of this study was to (1) analyze the dissolution behavior of the residual CaP particles of removed implants and (2) evaluate bone apposition of CaP-coated machined surface implants at the early healing phase. Methods: Mandibular premolars were extracted from five dogs. After eight weeks, the implants were placed according to drilling protocols: a nonmobile implant (NI) group and rotational implant (RI) group. For CaP dissolution behavior analysis, 8 implants were removed after 0, 1, 2, and 4 weeks. The surface morphology and deposition of the coatings were observed. For bone apposition analysis, block sections were obtained after 1-, 2-, and 4-week healing periods and the specimens were analyzed. Results: Calcium and phosphorus were detected in the implants that were removed immediately after insertion, and the other implants were composed mainly of titanium. There were no notable differences between the NI and RI groups in terms of the healing process. The bone-to-implant contact and bone density in the RI group showed a remarkable increase after 2 weeks of healing. Conclusions: It can be speculated that the CaP coating dissolves early in the healing phase and chemically induces early bone formation regardless of the primary stability.

Keywords

References

  1. Tjellstrom A, Lindstrom J, Hallen O, Albrektsson T, Branemark PI. Osseointegrated titanium implants in the temporal bone: a clinical study on bone-anchored hearing aids. Am J Otol 1981;2:304-10.
  2. Cooper LF. A role for surface topography in creating and maintaining bone at titanium endosseous implants. J Prosthet Dent 2000;84:522-34. https://doi.org/10.1067/mpr.2000.111966
  3. Shalabi MM, Gortemaker A, Van't Hof MA, Jansen JA, Creugers NH. Implant surface roughness and bone healing: a systematic review. J Dent Res 2006;85:496-500. https://doi.org/10.1177/154405910608500603
  4. Wennerberg A, Albrektsson T. Effects of titanium surface topography on bone integration: a systematic review. Clin Oral Implants Res 2009;20 Suppl 4:172-84. https://doi.org/10.1111/j.1600-0501.2009.01775.x
  5. Han T, Carranza FA Jr, Kenney EB. Calcium phosphate ceramics in dentistry: a review of the literature. J West Soc Periodontol Periodontal Abstr 1984;32:88-108.
  6. Davies JE. Understanding peri-implant endosseous healing. J Dent Educ 2003;67:932-49.
  7. Morimoto K, Kihara A, Takeshita F, Akedo H, Suetsugu T. Differences between the bony interfaces of titanium and hydroxyapatite-alumina plasma-sprayed titanium blade implants. J Oral Implantol 1988;14:314-24.
  8. Kay JF. Calcium phosphate coatings for dental implants. Current status and future potential. Dent Clin North Am 1992;36:1-18.
  9. McGlumphy EA, Peterson LJ, Larsen PE, Jeffcoat MK. Prospective study of 429 hydroxyapatite-coated cylindric omniloc implants placed in 121 patients. Int J Oral Maxillofac Implants 2003;18:82-92.
  10. Biesbrock AR, Edgerton M. Evaluation of the clinical predictability of hydroxyapatite-coated endosseous dental implants: a review of the literature. Int J Oral Maxillofac Implants 1995;10:712-20.
  11. Liao H, Fartash B, Li J. Stability of hydroxyapatite-coatings on titanium oral implants (IMZ): 2 retrieved cases. Clin Oral Implants Res 1997;8:68-72. https://doi.org/10.1111/j.1600-0501.1997.tb00009.x
  12. Hanisch O, Cortella CA, Boskovic MM, James RA, Slots J, Wikesjo UM. Experimental peri-implant tissue breakdown around hydroxyapatite-coated implants. J Periodontol 1997;68:59-66. https://doi.org/10.1902/jop.1997.68.1.59
  13. Klein CP, Patka P, van der Lubbe HB, Wolke JG, de Groot K. Plasma-sprayed coatings of tetracalciumphosphate, hydroxyl-apatite, and alpha-TCP on titanium alloy: an interface study. J Biomed Mater Res 1991;25:53-65. https://doi.org/10.1002/jbm.820250105
  14. Hayashi K, Inadome T, Mashima T, Sugioka Y. Comparison of bone-implant interface shear strength of solid hydroxyapatite and hydroxyapatite-coated titanium implants. J Biomed Mater Res 1993;27:557-63. https://doi.org/10.1002/jbm.820270502
  15. Albrektsson T. Hydroxyapatite-coated implants: a case against their use. J Oral Maxillofac Surg 1998;56:1312-26. https://doi.org/10.1016/S0278-2391(98)90616-4
  16. Choi JM, Kim HE, Lee IS. Ion-beam-assisted deposition (IBAD) of hydroxyapatite coating layer on Ti-based metal substrate. Biomaterials 2000;21:469-73. https://doi.org/10.1016/S0142-9612(99)00186-6
  17. Liu JQ, Luo ZS, Cui FZ, Duan XF, Peng LM. High-resolution transmission electron microscopy investigations of a highly adhesive hydroxyapatite coating/titanium interface fabricated by ion-beam-assisted deposition. J Biomed Mater Res 2000;52:115-8. https://doi.org/10.1002/1097-4636(200010)52:1<115::AID-JBM14>3.0.CO;2-X
  18. Lee IS, Kim DH, Kim HE, Jung YC, Han CH. Biological performance of calcium phosphate films formed on commercially pure Ti by electron-beam evaporation. Biomaterials 2002;23:609-15. https://doi.org/10.1016/S0142-9612(01)00147-8
  19. Kim MK, Choi JY, Chae GJ, Jung UW, Kim ST, Lee IS, et al. The histometric analysis of osseointegration in hydroxyapatite surface dental implants by ion beam-assisted deposition. J Korean Acad Periodontol 2008;38(Suppl):363-72. https://doi.org/10.5051/jkape.2008.38.Suppl.363
  20. Yoon HJ, Song JE, Um YJ, Chae GJ, Chung SM, Lee IS, et al. Effects of calcium phosphate coating to SLA surface implants by the ion-beam-assisted deposition method on self-contained coronal defect healing in dogs. Biomed Mater 2009;4:044107. https://doi.org/10.1088/1748-6041/4/4/044107
  21. Chae GJ, Jung UW, Jung SM, Lee IS, Cho KS, Kim CK, et al. Healing of surgically created circumferential gap around Nano-coating surface dental implants in dogs. Surf Interface Anal 2008;40:184-7. https://doi.org/10.1002/sia.2745
  22. Um YJ, Song JE, Chae GJ, Jung UW, Chung SM, Lee IS, et al. The effect of post heat treatment of hydroxyapatite-coated implants on the healing of circumferential coronal defects in dogs. Thin Solid Film 2009;517:5375-9. https://doi.org/10.1016/j.tsf.2009.03.107
  23. Meredith N. Assessment of implant stability as a prognostic determinant. Int J Prosthodont 1998;11:491-501.
  24. Jung UW, Kim S, Kim YH, Cha JK, Lee IS, Choi SH. Osseointegration of dental implants installed without mechanical engagement: a histometric analysis in dogs. Clin Oral Implants Res 2012;23:1297-301. https://doi.org/10.1111/j.1600-0501.2011.02306.x
  25. Blanco J, Alvarez E, Munoz F, Linares A, Cantalapiedra A. Influence on early osseointegration of dental implants installed with two different drilling protocols: a histomorphometric study in rabbit. Clin Oral Implants Res 2011;22:92-9. https://doi.org/10.1111/j.1600-0501.2010.02009.x
  26. Kim H, Choi SH, Chung SM, Li LH, Lee IS. Enhanced bone forming ability of SLA-treated Ti coated with a calcium phosphate thin film formed by e-beam evaporation. Biomed Mater 2010;5:044106. https://doi.org/10.1088/1748-6041/5/4/044106
  27. Lee IS, Zhao BH, Lee GH, Choi SH, Chung SM. Industrial application of ion beam assisted deposition on medical implants. Surf Coat Technol 2007;201:5132-7. https://doi.org/10.1016/j.surfcoat.2006.07.112
  28. Lee IS, Kim HE, Kim SY. Studies on calcium phosphate coatings. Surf Coat Technol 2000;131:181-6. https://doi.org/10.1016/S0257-8972(00)00811-2
  29. Lang NP, Jepsen S; Working Group 4. Implant surfaces and design (Working Group 4). Clin Oral Implants Res 2009;20 Suppl 4:228-31. https://doi.org/10.1111/j.1600-0501.2009.01771.x
  30. Lang NP, Berglundh T; Working Group 4 of Seventh European Workshop on Periodontology. Periimplant diseases: where are we now? Consensus of the Seventh European Workshop on Periodontology. J Clin Periodontol 2011;38 Suppl 11:178-81. https://doi.org/10.1111/j.1600-051X.2010.01674.x
  31. Choi JY, Jung UW, Kim CS, Jung SM, Lee IS, Choi SH. Influence of nanocoated calcium phosphate on two different types of implant surfaces in different bone environment: an animal study. Clin Oral Implants Res 2013;24:1018-22.
  32. Cui FZ, Luo ZS, Feng QL. Highly adhesive hydroxyapatite coatings on titanium alloy formed by ion beam assisted deposition. J Mater Sci Mater Med 1997;8:403-5. https://doi.org/10.1023/A:1018597320022
  33. Zablotsky M, Meffert R, Mills O, Burgess A, Lancaster D. The macroscopic, microscopic and spectrometric effects of various chemotherapeutic agents on the plasma-sprayed hydroxyapatite-coated implant surface. Clin Oral Implants Res 1992;3:189-98. https://doi.org/10.1034/j.1600-0501.1992.030406.x
  34. Davies JE. Mechanisms of endosseous integration. Int J Prosthodont 1998;11:391-401.
  35. Abrahamsson I, Berglundh T, Linder E, Lang NP, Lindhe J. Early bone formation adjacent to rough and turned endosseous implant surfaces: an experimental study in the dog. Clin Oral Implants Res 2004;15:381-92. https://doi.org/10.1111/j.1600-0501.2004.01082.x
  36. Novaes AB Jr, de Souza SL, de Barros RR, Pereira KK, Iezzi G, Piattelli A. Influence of implant surfaces on osseointegration. Braz Dent J 2010;21:471-81. https://doi.org/10.1590/S0103-64402010000600001
  37. Feng B, Chen J, Zhang X. Interaction of calcium and phosphate in apatite coating on titanium with serum albumin. Biomaterials 2002;23:2499-507. https://doi.org/10.1016/S0142-9612(01)00384-2
  38. Sul YT, Johansson CB, Albrektsson T. Oxidized titanium screws coated with calcium ions and their performance in rabbit bone. Int J Oral Maxillofac Implants 2002;17:625-34.

Cited by

  1. Randomized controlled clinical trial on calcium phosphate coated and conventional SLA surface implants: 1‐year study on survival rate and marginal bone level vol.21, pp.5, 2013, https://doi.org/10.1111/cid.12823
  2. Bioactive-Enhanced Polyetheretherketone Dental Implant Materials: Mechanical Characterization and Cellular Responses vol.47, pp.1, 2021, https://doi.org/10.1563/aaid-joi-d-19-00172