• 제목/요약/키워드: Bonding test

검색결과 1,172건 처리시간 0.028초

초소수성 발수제를 사용한 모르타르 표면의 결빙 방지 효과 (Anti-freezing effect of mortar surface with superhydrophobic water repellent)

  • 김상진;인병은;강석표
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 봄 학술논문 발표대회
    • /
    • pp.15-16
    • /
    • 2022
  • In order to examine the adhesion characteristics of road pavement according to environmental conditions, the freezing time of cement mortar and the adhesion performance between ice and pavement were evaluated depending on the presence or absence of polymer and water repellent. As a result of measuring the ice formation time, it was found that there was no delay when a polymer was added, but the complete freezing time was delayed when a water repellent was added. As a result of measuring the strength of ice adhesion, it was found that the bonding force between ice and the surface of the test body was greatly generated in the test body without water repellent. In the case of a test specimen to which a water repellent was added, it was found that the bonding strength between the test specimen surface and ice was reduced.

  • PDF

접착공법에 의해 전단보강된 RC보의 전단강도 예측 (Shear Strength Prediction of RC Beams Strengthened by Externally Bonding Method)

  • 박성민;변근주;송하원
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.69-74
    • /
    • 2001
  • Steel plate or fiber composite plate are mainly used in externally bonding method. Shear strengthening by externally bonding method is to confirm shear safety and to avoid brittle failure. In case of strengthening by externally bonding method, a failure of structure occurs frequently due to delamination between strengthening plate and concrete. Therefore, it is important to consider the delamination in the strengthening design. The objective of this study is to propose a modified shear strength evaluation by considering the delamination. The delamination criteria of strengthening plate is established by the ultimate strain and shear stress. And shear strength of RC beams is proposed in terms of the delamination criteria. The proposed shear strength is compared with test results and verified through the comparison.

  • PDF

차체접합과 관련한 접합 강도 평가 (Strength Evaluation of Adhesive Bonded Joint for Car Body)

  • 이강용;김종성;공병석;우형표
    • 한국자동차공학회논문집
    • /
    • 제6권1호
    • /
    • pp.143-150
    • /
    • 1998
  • The evaluation of joint fatigue strength of light weight materials for electrical vehicle body has been performed through single lap joint tests with the design parameters such as joint style, adherend, bonding overlap length and bonding thickness. Fatigue strength was evaluated through 5-Hz, tension-tension, load controlled test with the stress ratio zero value. It is experimentally observed that fatigue strength of joint increases for the increase of overlap length. The combinations of Al-Al and Al-FRP adherends show that fatigue strength of joint is hardly changed for the increase of bonding thickness, but FRP-FRP adherend specimen shows that fatigue strength of joint increases after decreases for the increase of bonding thickness. Al-Al adherend specimen has much higher fatigue length than Al-FRP and FRP-FRP adherend specimens. Riveting at adgesive bonded joint gives little effect on fatigue strength.

Sn-Pb 공정솔더 플립칩의 접합강도에 미치는 플라즈마 처리 효과 (Effect of Plasma Treatment on the Bond Strength of Sn-Pb Eutectic Solder Flip Chip)

  • 홍순민;강춘식;정재필
    • Journal of Welding and Joining
    • /
    • 제20권4호
    • /
    • pp.498-504
    • /
    • 2002
  • Fluxless flip chip bonding process using plasma treatment instead of flux was investigated. The effect of plasma process parameters on tin-oxide etching characteristics were estimated with Auger depth profile analysis. The die shear test was performed to evaluate the adhesion strength of the flip chip bonded after plasma treatment. The thickness of oxide layer on tin surface was reduced after Ar+H2 plasma treatment. The addition of H2 improved the oxide etching characteristics by plasma. The die shear strength of the plasma-treated Sn-Pb solder flip chip was higher than that of non-treated one but lower than that of fluxed one. The difference of the strength between plasma-treated specimen and non-treated one increased with increase in bonding temperature. The plasma-treated flip chip fractured at solder/TSM interface at low bonding temperature while the fracture occurred at solder/UBM interface at higher bonding temperature.

표면처리방법에 따른 초고성능 콘크리트의 전단부착성능 평가 연구 (An Assessment of Bonding Shear Performance of Ultra-high-performance Concrete Regarding Interface Treatment)

  • 장현오;박진호;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 추계 학술논문 발표대회
    • /
    • pp.81-82
    • /
    • 2016
  • The present study aims to derive optimal interface treatment conditions for emulating a monolithic construction. The joints in this construction are formed through the bonding shear evaluation method during the placement of ultra-high-performance concrete (UHPC) and normal strength concrete (NSC). The evaluation items include push-off tests for homogeneous UHPC + UHPC and heterogeneous NSC + UHPC. The experimental samples comprised a monolithic placement as the baseline, two levels for the separated placement according to the compression strength of concrete, and five levels for the interface treatment. The increase in the number of grooves and their cross-sectional areas only slightly influenced the bonding shear performance. The optimal interface treatment method for the homogeneous UHPC + UHPC construction grooves was at least 30mm. The heterogeneous NSC + UHPC construction should utilize waterjet roughening to expose the aggregate for the increased roughness.

  • PDF

단일겹침 접착제 접합부의 응력분포와 강도평가 (Stress Distribution and Strength Evaluation of Adhesive Bonded Single-lap Joints)

  • 이중삼;임재규;김연직
    • Journal of Welding and Joining
    • /
    • 제19권3호
    • /
    • pp.342-347
    • /
    • 2001
  • Recently, adhesive-bonding technique is wifely used in manufacturing structures. Stress and strain analysis of joints are essential to design adhesive-bonded joints structure. The single-lap adhesive joint is the design dominating the range of adhesive joints. In this study, single-lap specimens with different joint dimensions were used for the tensile-shear test and finite element calculation in of order to investigate the effect of overlap length and adhesive-bonding thickness on adhesive strength and stress distribution of the joints. Consequently, it was found that overlap lap size and thickness can be important parameters of structure joints using adhesive bonding, which is effected on adhesive strength.

  • PDF

단면 겹치기 이음 시험에 의한 경량구조물용 접착 이음강도의 평가 (Strength Evaluation of Adhesive Bonded Joint for Light Weight Structure by Single-Lab Joint Test)

  • 이강용;김준범;최홍섭;우형표
    • 한국자동차공학회논문집
    • /
    • 제5권2호
    • /
    • pp.87-93
    • /
    • 1997
  • The bonding strength evaluation of light weight materials for electrical vehicle applications has been performed through single lap joint tests in which the design parameters such as fillet, joint style, adherend, bonding overlap length,bonding thickness, and environmental condition(soaking time in $25^{\circ}C$ water) are considered. It is experimentally oberved that lap shear strength of joint increases for higher fillet height, longer overlap length, and thinner bonding layer thickness. Al-Al adherend combination shows much higher lap shear strength than AL-FRP and FRP-FRP adherend combinations. Riveting at adhesive bonded joint of AL-AL adherend combination makes lap shear strength decrease. Effect of soaking time on lap shear strength is negligible.

  • PDF

와이어 본딩시 본딩 패드 리프트 불량에 관한 연구 (Study on the Bonding Pad Lift Failure in Wire Bonding)

  • 김경섭;장의구;신영의
    • 한국전기전자재료학회논문지
    • /
    • 제11권12호
    • /
    • pp.1079-1083
    • /
    • 1998
  • In this study, ultrasonic power of Aluminum wire bonder, bond time and bond force are investigated and valued in order to minimize failure of bonding pad lift. We also tried to control those 3 factors properly. We got the conclusion that if we turn down the ability of ultrasonic power or bond time, we can get a pad lift from a boundary between bond pad ad wire because pad metal and wire joining is unstable, but it is best condition when it ultrasonic power is 100∼130unit, bond time is 15∼20msec and bond force is 4∼6gf.

  • PDF

미백 후 유예 기간에 따른 상아질과 레진의 결합 강도의 변화 (Effect of post-bleaching time intervals on resin in dentin bonding strength)

  • 송신재;김선종;노영선;류재준
    • 대한치과보철학회지
    • /
    • 제47권2호
    • /
    • pp.174-181
    • /
    • 2009
  • 연구목적: 본 연구에서는 35% 과산화수소를 사용하는 전문가 미백 술식에서 레진 접착제의 접착력 회복을 위한 유예 기간을 비교하고자 한다. 연구 재료 및 방법:3M사의 Single Bond와 Z350을 이용하여 미백 직 후, 1일후, 2일후, 일주일 후의 시간 차이를 두고 상아질에 접착된 복합 레진의 전단 결합 강도를 측정하여 다음과 같은 결과를 얻었다. 결과: 미백 처리 직 후의 상아질 전단 결합 강도는 다른 군에 비해 유의하게 낮았으며(P<.05), 미백 처리 전에 비해 약 78%의 결합력 감소를 보였다. 미백 처리 1일 후의 상아질 결합 강도는 미백 직 후 감소된 결합력의 51%에 이르는 회복을 보였으며, 2일 경과한 시편에서는 감소된 결합력의 63%가 회복되었다. 두 군은 미백 직 후에 비해 유의하게 큰 회복력을 보였으나, 두 군 간에는 유의한 차이가 없었다(P>.05). 미백 처리 후 결합력의 회복은 초기 24시간 이내에 급격히 일어나며 그 이후에는 서서히 일어나는 것으로 사료된다. 미백 일주일 후의 시편은 미백 처리 전에 비해97%에 이르는 결합력을 보이며 두 군 간에는 유의한 차이가 없었다(P>.05). 결론: 그러므로35% 과산화수소를 적용하는 전문가 미백 술식에서는 1주일간의 유예기간을 두고 복합 레진 접착술을 시행하는 것이 적절할 것으로 사료된다.

Cu-C$u_2$O의 공정반응에 의한 구리와 알루미나의 직접접합 (The Direct Bonding of Copper to Alumina by $Cu-Cu_2$O Eutectic Reaction)

  • 유환성;이임열
    • 한국재료학회지
    • /
    • 제2권4호
    • /
    • pp.241-247
    • /
    • 1992
  • 본 연구에서는 $Cu-Cu_2$O의 공정반응에 의한 구리와 알루미나의 직접접합에 대하여 연구 하였다. $1.5{\times}10^{-1}$torr, $1015^{\circ}C$에서 산화시킨 후 $10_{-3}$torr, 107$5^{\circ}C$에서 접합시킨 시편의 접합력과 계면특성을 인장시험, SEM, EDS 및 XRD를 통하여 분석하였다. 3분 산화시켜 접합하면 우수한 접합강도를 보이며 산화시간이 이보다 짧거나 길면 결합력은 저하하였다. 과단은 알루미나 공정조직 계면에서 발생하였으며 파단후 $Al_2O_3$표면에는 Cu쪽에서 빠져나간 $Cu_2$O nodule의 존재하였는 바 접합력은 $Cu_2$O-A$l_2O_3$계면보다는 $Cu-Cu_2$O계면에 좌우됨을 보여주고 있다. 접합력은 접합시간에 따라 완만한 증가를 보였으며 CuA$l_2O_4$$CuAlO_2$의 반응생성물이 접합중 형성되었다.

  • PDF