• 제목/요약/키워드: Bonding length

검색결과 268건 처리시간 0.022초

Experimental Study on Interfacial Behavior of CFRP-bonded Concrete

  • Chu, In-Yeop;Woo, Sang-Kyun;Lee, Yun
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제1권1호
    • /
    • pp.127-134
    • /
    • 2015
  • Recently, the external bonding of carbon fiber reinforced polymer (CFRP) sheets has come to be regarded as a very effective method for strengthening of reinforced concrete structures. The behavior of CFRP-strengthened RC structure is mainly governed by the interfacial behavior, which represents the stress transfer and relative slip between concrete and the CFRP sheet. In this study, the effects of bonded length, width and concrete strength on the interfacial behavior are verified and a bond-slip model is proposed. The proposed bond-slip model has nonlinear ascending regions and exponential descending regions, facilitated by modifying the conventional bilinear bond-slip model. Finite element analysis results of interface element implemented with bond-slip model have shown good agreement with the experimental results performed in this study. It is found that the failure load and strain distribution predicted by finite element analysis with the proposed bond-slip are in good agreement with results of experiments.

혈압 측정을 위한 외팔보형 접촉힘 센서 어레이 (A Cantilever Type Contact Force Sensor Array for Blood Pressure Measurement)

  • 이병렬;정진우;전국진
    • 센서학회지
    • /
    • 제21권2호
    • /
    • pp.121-126
    • /
    • 2012
  • Piezoresistive type contact force sensor array is fabricated by (111) Silicon bulk micromachining for continuous blood pressure monitoring. Length and width of the unit sensor structure is $200{\mu}m$ and $190{\mu}m$, respectively. The gap between sensing elements is only $10{\mu}m$. To achieve wafer level packaging, the sensor structure is capped by PDMS soft cap using wafer molding and bonding process with $10{\mu}m$ alignment precision. The resistance change over contact force was measured to verify the feasibility of the proposed sensor scheme. The maximum measurement range and resolution is 900 mm Hg and 0.57 mm Hg, respectively.

N-Methylmorpholine N-Oxide 수용액을 이용한 면직물의 의마(擬麻) 가공 (Linen-like Finishing of Cotton Fabric Using Aqueous Solutions of N-Methylmorpholine N-Oxide)

  • 손현식;김진호;윤경훈;강영아;이양헌
    • 한국염색가공학회지
    • /
    • 제14권5호
    • /
    • pp.261-267
    • /
    • 2002
  • Cotton fabrics were immersed in aqueous solution of N-methylmorpholine N-oxide(NMMO) with various concentrations, padded by 300% of pick-up, concentrated at $90^\circ{C}$ for 30min under constant-length condition, washed, and dried, to examine a possibility of linen-like finishing by the solvent bonding between fibers. With increasing the concentration of NMMO, cross-sections of fibers changed to oval or polygonal shapes and not only the fibers but also the warp and weft were bonded each other, which produced linen-like effect on the fabrics in the aspects of appearance and mechanical properties such as the Increase of stiffness and shear properties. The thickness, moisture regain and dyeability were increased with the concentration of NMMO.

시스 순환전류 저감장치의 개발 및 전기적 특성 검토 (Development of Restraining-unit of Sheath Circulating Current and Its Electrical Characteristics)

  • 하체웅;김정년;김동욱;강지원;김재승
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.394-396
    • /
    • 2004
  • In order to reduce the sheath circulating current, same arrangement and balanced length of cable are required for the underground cable system. But practically, changing the whole arrange of cable which is already constructed is impossible. Therefore, It is necessary to apply the restraining-unit of sheath circulating current at the cross-bonding wire of insulated joint because the impedance of restraining-unit is able to reduce sheath circulating current at a normal condition. Even at a transient state, the restraining-unit must maintain electrical and mechanical characteristics. In this paper, the features of restraining-unit developed by LG Cable as well as the electrical test results are described. It proves that the restraining-unit is applicable to the underground cable system where sheath circulating current rises.

  • PDF

2-Methyl-3-(N-trimethyl ammonium)phenol Iodide의 결정 구조 (The Crystal Structure of 2-Methyl-3-(N-trimethyl ammonium)phenol Iodide)

  • 조성일;윤혜숙;구정회
    • 약학회지
    • /
    • 제24권2호
    • /
    • pp.135-141
    • /
    • 1980
  • The crystal and molecular structure of 2-methyl-3-(N-trimethyl ammonium)phenol iodide, $C_{10}H_{16}NOI, was determined by X-ray diffraction method. The compound crystallizes in the orthorhombic space group $P_{na2}_{1}$ with a=13.327(3), b=12.496(3), C=7.227(2)A and Z=4. A total of 489 independent observed reflections were collected by the automated Four-circle diffractometer and was solved by heavy atom method and refined by anisotropic block-diagonal least-squares method to the R value of 0.04. The benzene ring is slightly distorted from regular hexagon. The I atom and 2-methyl-3-(N-trimethyl ammonium)phenol group is held together by van der Waals forces in the crystal. Intermolecular hydrogen bond is of the type O-H....I with the length 3.35.angs.. Apart from the hydrogen bonding system the molecules are held together by van der Waals forces in the crystal.

  • PDF

다양한 표면형상에 따른 FRP 보강재의 부착특성 실험연구 (An Experimental Study on Bond Characteristics of FRP Reinforcements with Various Surface-type)

  • 정우태;박영환;박종섭
    • 대한토목학회논문집
    • /
    • 제31권4A호
    • /
    • pp.279-286
    • /
    • 2011
  • FRP 긴장재는 PS 강연선의 부식 문제를 해결하기 위한 대안으로써 사용될 수 있으며, FRP 긴장재의 재료특성(부착강도, 인장강도, 전달길이 등)은 구조물에 적용하기 위해서 결정되어야 한다. 재료특성 중에 부착은 FRP 긴장재로 긴장된 PSC 구조물에 적용하기 위해 명확하게 요구되어야 한다. 이 연구는 다양한 표면형상을 갖는 FRP 보강재의 부착특성을 연구하였다. 콘크리트의 철근과 강연선 대신에 사용되는 FRP 재료의 부착특성을 결정하기 위해 CAN/CSA S806-02에서 제안된 직접인발 시험을 수행하였다. 강연선, 이형 철근, 6가지 다른 표면 형상을 갖는 탄소 또는 유리섬유 FRP 보강재에 대하여 총 40개의 시편이 제작되었다. 부착실험 결과 각 실험체의 다양한 부착응력-슬립 곡선을 나타냈고, 국내에서 제작된 CFRP 긴장재의 부착특성과 비교하였다.

Bisamino-PEG가 함유된 키토산 비드의 팽윤성 및 방출 특성 (Swelling Properties and Releasing Characteristics of Chitosan Beads Containing Bisamino-PEG)

  • 하병조;이옥섭;이윤식
    • 공업화학
    • /
    • 제7권1호
    • /
    • pp.59-66
    • /
    • 1996
  • 양말단에 아미노기가 결합된 일련의 bisamino-PEG($Jeffamine^{(R)}ED$)를 함유한 키토산 비드들을 알칼리 용액을 사용한 capillary extrusion method에 의해 제조하였다. 제조된 각각의 비드들에 대한 swelling kinetics를 조사한 결과, 키토산비드 내부에 PEG 사슬이 길어질수록 팽윤이 늦게 진행되었다. 또한 키토산 비드에 함유된 bisamino-PEG들의 방출현상을 정량적으로 알아 보기 위해 양말단의 1차 아민기에 fluorescamine을 결합시킨 후, UV spectra로 방출과정을 추적하였다. 실험결과 키토산 비드 내부에 있는 PEG 사슬이 길수록 방출시간은 $Jeffamine^{(R)}ED$-600 < $Jeffamine^{(R)}ED$-900 < $Jeffamine^{(R)}ED$-2001 순으로 지연되는 경향을 나타내었다. 이는 PEG 사슬이 길어질수록 키토산과의 수소결합에 의한 상호작용이 강화되고 그 결과 방출기간이 지연된 것으로 사료된다.

  • PDF

하이브리드 복합재료의 층간파괴인성치에 관한 연구 (A Study on the Interlaminar Fracture Toughness of Hybrid Composites)

  • 김형진;곽대원;이헌식;김재동;고성위
    • 수산해양기술연구
    • /
    • 제40권4호
    • /
    • pp.328-336
    • /
    • 2004
  • 하이브리드 복합재료(Hybrid composites) 의 층간 파괴 인성치에 영향을 주는 인자 중 적층순서, 하중점변위율, 초기크랙길이를 변화 시켰을 때의 실험 결과는 다음과 같다. (1) CF/CF, CF/GF. GF/GF로 적층하였을 경우 층간파괴인성치값은 서로 같은 계면을 성형한 것보다 서로 다른 계면을 적층한 CF/GF의 경우가 강도면에서 가장 높게 나타나는 것을 알 수 있었다. (2) 하중점변위율은 미세한 변동은 있었으나, 하중점변위율의 영향은 거의 받기 않는 것을 알 수 있었다. (3) 초기크랙을 변화시켰을 때, 초기크랙길이의 영향은 일정하지 않았다. CF/CF인 경우는 초기크랙이 짧은 경우, CF/GF. GF/GF인 경우는 초기크랙이 긴 경우에 높은 값을 나타났다. 이것은 GF 섬유가 직조형태의 프리프레그로 되어 있어 크랙의 진전에 따라 섬유부스러기 등의 생성에 따른 영향이라고 생각된다. (4) 적층순서에 따라 파면의 섬유 분포 형태가 달랐으며 CF/GF인 경우가 섬유의 파손형태가 가장 복잡하게 나타났으며, 이것이 높은 층간파괴인성치를 나타내는 원인이라고 판단된다.

하이브리드 복합재료의 모드 I 층간파괴인성치에 관한 연구 (A Study on Mode I Interlaminar Fracture Toughness of Hybrid Composites)

  • 김형진;곽대원;김재동;고성위
    • 수산해양기술연구
    • /
    • 제39권4호
    • /
    • pp.262-268
    • /
    • 2003
  • 하이브리드 복합재료(Hybrid composite)의 모드 I 층간파괴인성치에 영영향 주는 인자 중 적층순서, 하중점변위율, 초기크랙길이를 변화 시켰을 때의 실험 결과는 다음과 같다. (1) CF/CF, CF/GF, GF/GF로 적층하였을 경우 층간파괴인성치값은 서로 같은 계면을 성형한 것보다 서로 다른 계면을 적층한 CF/GF 의 경우가 강도면에서 가장 높게 나타나는 것을 알 수 있다. (2) 하중점변위율을 0.2, 2, 20mm/min로 변화하였을 때, 미세한 변동은 있었으나, 허중점변위율의 영향은 거의 받지 않는 것을 알 수 있었다. (3) 초기크랙을 25, 30, 35, 40, 50mm로 변화시켰을 때 초기크랙길이의 영향은 일정하지 않았다. CF/CF인 경우는 초기크랙이 짧은 경우, CF/GF, GF/GF인 경우는 초기크랙이 긴 경우에 높은 값을 나타냈다. 이것은 GF 섬유가 직조형태의 프리프레그로 되어 있어 크랙의 진전에 따라 섬유부스러기 등의 생성에 따른 영향이라고 생각된다. (4) 적층순서에 따라 파면의 섬유 분포 형태가 달랐으며, CF/GF인 경우가 섬유의 파손형태가 가장 복잡하게 나타났으며, 이것이 높은 층간파괴인성치를 나타내는 원인이라고 판단된다.

에틸렌 글리콜 용액에서 물 함량에 따른 티타늄 양극산화 나노튜브의 성장거동 (Growth Behaviors of Anodic Titanium Oxide Nanotubes in the Ethylene Glycol Solution According to Water Contents)

  • 이병관;이성은;최진욱;정용수;오한준;이오연;지충수
    • 대한금속재료학회지
    • /
    • 제46권11호
    • /
    • pp.730-736
    • /
    • 2008
  • $TiO_2$ nanotubes fabricated in aqueous HF-based electrolytes have been generally grown only to about 500nm in length because of the strong dissolubility of HF acid. In this paper, ethylene glycol solution has been applied for increasing the length of the anodic $TiO_2$ nanotubes, and the growth behaviors of the nanotubes according to water contents has been investigated. Anodization of Ti in ethylene glycol + 1 wt% $NH_4F$ (EG solution) with water additions up to 10 wt% were carried out at the constant voltage of 20 V. The results show that a thin titanium oxide layer is formed in the initial stage and the nanotube structure grows underneath the initial layer. And the length of $TiO_2$ nanotubes decreases with the increasing water content in the solution. It can be ascribed to the locally acidified circumstance around the barrier layer inside the nanopore due to $H^+$ ion originated from water. The XPS for the nanotubes suggests that the spectra of Ti2p and O1s are the major chemical bonding states of the $TiO_2$, and those for F1s, N1s and C1s come from the compound of $(NH_4)_2TiF_6$.