• 제목/요약/키워드: Bonding length

검색결과 268건 처리시간 0.027초

BeCu 금속박판을 이용한 테스트 소켓 제작 (Fabrication of Test Socket from BeCu Metal Sheet)

  • 김봉환
    • 센서학회지
    • /
    • 제21권1호
    • /
    • pp.34-38
    • /
    • 2012
  • We have developed a cost effective test socket for ball grid array(BGA) integrated circuit(IC) packages using BeCu metal sheet as a test probe. The BeCu furnishes the best combination of electrical conductivity and corrosion resistance. The probe of the test socket was designed with a BeCu cantilever. The cantilever was designed with a length of 450 ${\mu}m$, a width of 200 ${\mu}m$, a thickness of 10 ${\mu}m$, and a pitch of 650 ${\mu}m$ for $11{\times}11$ BGA. The fabrication of the test socket used techniques such as through-silicon-via filling, bonding silicon wafer and BeCu metal sheet with dry film resist(DFR). The test socket is applicable for BGA IC chip.

탄소h강(SM45C)과 알루미늄 합금(A6063)의 마찰용접성에 관한 연구 (A Study on the Friction Weldability of Carbon Steel (SM45C) to Aluminum Alloy (A6063))

  • 강성보;민택기
    • Journal of Welding and Joining
    • /
    • 제16권2호
    • /
    • pp.57-63
    • /
    • 1998
  • This study deals with the friction weldability of machine structural carbon steel (SM45C) to Al-Mg-Si aluminium alloy (A6063). The bonding strength of friction welded joints, from all mechanical test, exceeded that of A6063 base metal, under the condition of friction time 1.5 sec, upset pressure 80MPa. The friction welded joints under these conditions exhibited tensile strength of 262MPa, bending angle of 90$^{\circ}$ without crack at weld interface and shear strength of 113MPa. Consequently, the friction weldability of SM4C to A6063 was very excellent, and that was possible without special preparation of weld surfaces.

  • PDF

철근콘크리트 부재의 유효 휨강성 평가를 위한 실험적 연구 (An Experimental Study on the Evaluation of Effective Flexural Rigidity in Reinforced Concrete Members)

  • 김상식;이진섭;이승배;장수연
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.131-134
    • /
    • 2005
  • Until recently tensile stresses in concrete have not been considered, since it does not affect the ultimate strength of reinforced concrete flexural members significantly. However, to verify the load-deflection relationship, the effect of tensile stresses between reinforcing bars and concrete, so-called tension stiffening effect must be taken into account. Main parameters of the tension stiffening behavior are known as concrete strength, and bond between concrete and reinforcing bars. In this study a total of twenty specimen subject to bending was tested with different concrete strength, coverage, and de-bonding length of longitudinal bars. The effects of these parameters on the flexural rigidity, crack initiation and propagation were carefully checked and analyzed.

  • PDF

교정장치가 치간조직에 미치는 영향에 관한 임상적 연구 (A CLINICAL STUDY OF THE EFFECTS OF ORTHODONTIC APPLIANCES ON THE GINGIVAL TISSUE)

  • 장기영
    • 대한치과교정학회지
    • /
    • 제15권2호
    • /
    • pp.291-301
    • /
    • 1985
  • Fifty subjects who were to be treated with fixed orhodontic appliances by light wire edgewise technique were selected. Bands with different marginal depth were made in first molar and direct bonding brackets were bonded in second premolar. For determining the effects of fixed orthodontic appliance on the gingival tissue, the changes of clinical crown length, periodontal pocket depth, gingival sulcus fluid were checked. The results were as follows: 1. Gingival condition was deteriorated after wearing the fixed orthodontic appliance, and the deteriorative rate was decreased gradually. 2. The greatest gingival change was occurred in the maxillary first molar among the experimental teeth. 3. The gingival change of maxillary teeth was greater than that of mandibular teeth. $(p\leq0.01)$ 4. The greater gingival change was occurred around subgingivally located band than around supragingivally located band. 5. Comparing the gingival changes of banded teeth with them of bonded teeth, the gingival tissue was more effected by oral hygiene than by type of appliances. 6. In the quantitive changes of gingival crevicular fluid, there was no exact relationship with gingival inflammation.

  • PDF

345kV 지중 및 혼합 송전계통에서의 개폐 과전압 해석 (Analysis of Switching Overvoltage in 345kV Underground and Combined Transmission Systems)

  • 정채균;이종범;강지원
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권12호
    • /
    • pp.713-721
    • /
    • 2003
  • This paper analyzes the switching overvoltage occurred on 345kV underground power cable system as well as combined transmission system using EMTP. Cable length and closing time, preinsertion resistance have effect on switching overvoltage. Therefore, this paper analyzes the switching overvoltage occurred on conductor and sheath with change of those parameters. Specially, the cross bonding position becomes discontinuity point because of the difference between surge impedance of metal sheath and that of lead cable. Thus, the transmission and the reflection of traveling wave complexly occur at this connection point. According to these influences, voltage between sheath and earth as well as voltage between joint boxes rise. Time to crest point of switching overvoltage is longer than lightning overvoltage. Even though the voltage induced by switching surge is smaller than lightning surge, that voltage may have serious effect on the metal sheath. Therefore, this paper also analyses the reduction effect of switching overvoltage when the preinsertion resistance of circuit breaker is considered.

변형속도에 따른 폴라아미드 섬유 및 후크형 강섬유 보강 시멘트 복합체의 인장특성 (Tensile Properties of Polyamide Fiber and Hooked Steel Fiber Reinforced Cementitious Composites by Strain Rate)

  • 이상규;김규용;황의철;손민재;백재욱;남정수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 추계 학술논문 발표대회
    • /
    • pp.73-74
    • /
    • 2018
  • In this study, it evaluate the tensile properties of polyamide fiber reinforced cementitious composite and hooked steel fiber reinforced cementitious Composites by strain rate. Polyamide fiber reinforced cement composites (PAFRCC) and Hooked Steel Fiber Reinforced Cement Composite(HSFRCC) were fabricated. Each specimen was reinforced with 1.0 and 2.0vol% fiber. The length of the reinforced fiber was 30 mm for both fibers, and the tensile test specimen was made in dumbbell shape. As a result, the tensile strength of fiber in polyamide fiber and the mechanical bonding between fiber and matrix in hooked steel fiber are considered to be the main factors affecting tensile behavior of fiber reinforced cement composite.

  • PDF

DFT Study of Bis(Crown-Ether) Analogue of Troger’s Base Complexed with Bisammonium Ions: Hydrogen Bonds

  • Kim, Kwan-Ho;Choe, Jong-In
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권11호
    • /
    • pp.1737-1740
    • /
    • 2006
  • The optimized structures and complexation energies of bis(18-crown-6-ether) analogue (2) of Trgers base (1) with a series of primary alkylbisammonium ions have been calculated by DFT B3LYP/6-31G(d,p) method. The calculated complexation efficiency (-142.84 kcal/mol) of 2 for butane-1,4-diylbisammonium guest is better than twice of the value (-61.40 kcal/mol) for butylammonium ion. The multiple hydrogen-bond abilities for the complexes are described as the function of the length of the alkyl substituents of the bisammonium guests with normal-alkyl chain [$-(CH_2)_{n-}$, n = 4-8]. The longer bisammonium guest shows the stronger hydrogen-bonding characterizations (the distance and the quasi-linear angle of the N-H…O) to the host 2 than the shorter bisammonium ions. These calculated results agree with the experimental data of the complexation of 2 with bisammonium salts ([$NH_3(CH_2)_nNH_3$] $Cl_2$).

Conducting Properties of Polypyrrole Coated Imogolite

  • Lee, Yun-Ha;Kim, Bum-Joong;Yi, Whi-kun;Takahara, Atsushi;Sohn, Dae-Won
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권11호
    • /
    • pp.1815-1818
    • /
    • 2006
  • Imogolite which has chemical composition, $(HO)_3Al_2O_3SiOH$, was synthesized with orthosilicate acid and aluminium chloride at low pH solution. It has extremely large aspect ratio with an external diameter of 2nm and the length of a few micrometers. The high aspect ratio of the imogolite could make the material as the filler for the high strength fiber and as the wire for the electronic applications. Here, Imogolite that derives considerable microporosity from a nanometer-sized tubular structure has been modified with a conducting polymer, polypyrrole. Its bonding and wiring structure were confirmed by IR and TEM. The measured conductivity after modification with polypyrrole increased with polypyrrole thickness at various voltage conditions.

콘크리트와 탐소섬유판 계면의 본드-슬립모델 산정 (Assessment of Bond-Slip Interface Model with Concrete and CFRP Plates)

  • 양동석;고병순;박선규;유영찬
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.635-638
    • /
    • 2004
  • External bonding of steel plates has been used to strengthen deficient reinforced-concrete structures since the 1960s. In recent years, fiber-reinforcde polymer(FRP) plates have been increasingly used to replace steel plates due to their superior properties. This paper is concerned with anchorage failure due to crack propagation parallel to the boned plated near or along the adhesive/concrete interface, staring from the critically stressed position toward the anchored end of the plates. Factor of bond-slip interface model is average bond stress, effective length, slip volume and fracture energy. The aim of the present paper is to provide a comprehensive assessment of bond-slip interface model with concrete and CFRP plates.

  • PDF

탄소섬유 보강재로 표면매립공법에 의해 보강된 콘크리트 보의 보강성능 연구 (A Study for strengthening Capacity of concrete Beam Strengthened with Near-Surface Mounted Carbon Fiber Reinforced Polymer)

  • 오홍섭;심종성;주민관;권영락
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.145-148
    • /
    • 2006
  • Near surface mounted (NSM) is a recent strengthening technique based on bonding fiber reinforced polymer (CFRP) bars (rods and laminate strips), the use of NSM FRP bars is Emerging as a promising technology for increasing flexural strength of deficient concrete. In order for this technique to perform effectively, the structural behaviour of RC element strengthened with NSM FRP bars to be fully characterized. Totally, 10 beams were tested using symmetrical two-point loads test. The parameters examined under the beam test were a diffrent type of strengthening length.

  • PDF