• 제목/요약/키워드: Boiler simulation

검색결과 175건 처리시간 0.024초

초임계 오일 연소 보일러의 동특성 예측 연구 - 650MWe급 화력발전소의 Load Runback 모사 (Dynamic performance prediction of a Supercritical oil firing boiler - Load Runback simulation in a 650MWe thermal power plant)

  • 양종인;김정래
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2014년도 제49회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.19-20
    • /
    • 2014
  • Boiler design should be desinged to maximize thermal efficiency of the system under imposed load requirement and a boiler should be validated for transient operation. If a proper prediction is possible on the transient behavior and transient characteristics of a boiler, one may asses the performance of boiler component, control logics and operation procedures. In this work, dynamic modeling method of boiler is presented and dynamic simulation of load runback scenario was carried out on suprecritical oil-firing boiler.

  • PDF

The Simulation of Boiler System for HADONG Fossil Power Plant

  • Choi, Jin-Ho;Ma, Sam-Sun;Lee,Yong-Kwan
    • 한국시뮬레이션학회:학술대회논문집
    • /
    • 한국시뮬레이션학회 1999년도 추계학술대회 논문집
    • /
    • pp.56-61
    • /
    • 1999
  • The Simulation of Boiler System for Hadong Fossil power plant has been made by Korea Electric Power Research Institute (KERRI) in an attempt to develop Windown NT based full scope replica simulator for Hadong Fossil power plant, 500MWe once-through boiler. In the project KERRI developed Once Through, Super Critical type Boiler System, the core part of the Simulation and integrated the system with other process systems such as BOP System, and AUX System. This paper is to introduce the basic concept of the simulation for the Boiler System. It will also introduce PRO-TRAX System, for used as a modeling tool.

  • PDF

드럼형 보일러의 동특성 해석을 위한 모듈 개념의 가상 플랜트 구현 (Implementation of virtual plant using module concept for the dynamic simulation of drum type boiler)

  • 남채호;권상혁;노태정;이광식
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.476-479
    • /
    • 1997
  • The focus of this paper is to implement of virtual plant using module concept for the dynamic simulation of drum type boiler and to simulate the control trends of dynamic characteristics. MAtlab & Simulink is used for implement virtual plant & analyzation the dynamics & control trends. They are available for analyzing the dynamic characteristics of drum type Boiler by means of applying well measured data to virtual plant.

  • PDF

2MWe 순환유동상 보일러의 부분 부하 운전 성능 모사 (Performance Simulation of Part Load Operation for 2MWe Circulating Fluidized Bed Boiler)

  • 김태현;최상민;현주수
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2012년도 제44회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.35-36
    • /
    • 2012
  • Part load operation usually covers large periods of the total operation time on the economic ground and electricity demand in small-scale boilers. Performance analysis of part load behavior is very important for the purpose of boiler operation optimization. A simple thermal calculation approach is applied to predict performance of a pilot-scale circulating fluidized bed (CFB) boiler at part load operation. Verification has been carried out by comparing between calculation results an operation data of the boiler.

  • PDF

콘덴싱 가스보일러시스템의 제어 알고리즘 개발을 위한 효과적인 동적모델 (Effective Dynamic Models for the Development of Control Algorithms of a Condensing Gas Boiler System)

  • 한도영;김성학
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.34-39
    • /
    • 2007
  • Condensing gas boiler units may make a big role for the reduction of energy consumption in heating industries. In order to decrease the energy consumption of a condensing gas boiler unit, the effective operations and controls of the system are necessary. In this study, mathematical models of a condensing gas boiler system were developed and programmed in order to predict dynamic behaviors of the system. These include dynamic models for a blower, a gas valve, a pump, a burner, a boiler heat exchanger, and a hot water heat exchanger. Control algorithms for the control of a gas valve, a blower, and a pump were also assumed. Simulation results showed good predictions of the dynamic phenomena of a boiler system. Therefore, the simulation program developed for this study may be effectively used for the development of control algorithms of the boiler system.

  • PDF

應答係數法에 의한 溫水 溫室 暖房 시스템의 Simulation (Simulation of the hot water ONDOL heating system by response factor method)

  • 조상준;민만기;최영돈
    • 대한기계학회논문집
    • /
    • 제11권3호
    • /
    • pp.409-424
    • /
    • 1987
  • 본 연구에서는 유한차분법보다는 정확도가 약간 떨어지지만 공기조화 분야의 계산에 적합하고 계산시간이 적게 소요되는 응답계수법을 사용하여 온수온돌방계의 비 정상 열전달을 해석하였다.

군간부 숙소에 적용된 중용량 및 멀티 보일러 시스템의 난방 및 급탕에너지 비교 (Heating and Hot Water Supply Energy Comparison of Medium Capacity and Multi Boilers System applied to Military Officer Housing)

  • 김민용;김영일;정광섭
    • 한국지열·수열에너지학회논문집
    • /
    • 제10권3호
    • /
    • pp.8-16
    • /
    • 2014
  • Heating and hot water supply energy consumption of medium and multi boiler systems applied to military officer housing are compared with in-situ experiment and TRNSYS dynamic simulation program. In a multiple boiler system, small capacity boilers are connected in parallel to meet the required capacity. For handling partial loads, medium capacity boiler relies on on-off control, while multi boiler adopts PI control. Since multi boiler has higher efficiency and better control strategy, the results show that energy consumption can be reduced significantly with the multi boiler system.

보일러 드럼의 안전조업을 위한 동특성 모델링 및 제어기 설계 (Dynamic Simulation and Controller Design for the Safe Operation of Boiler Drum)

  • 이익형
    • 한국안전학회지
    • /
    • 제8권4호
    • /
    • pp.133-138
    • /
    • 1993
  • The stable and safe operation of a boiler system is essential for ensuring stability of the chemical processes. A dynamic simulation of a boiler drum was performed to identify the dynamics of the boiler drum. The obtained results represented that the variation of process variables disturb boiler system. So, disturbance rejection with tracking and constraints handing was necessary for stable operation of boiler drum. Among many controller, GPC has been known to show good performance in set point tracking than disturbance. In order to improve disturbance rejection performance measurable disturbance term was Introduced in basic GPC model. The controller which had tracking and disturbance rejection was designed for Improving the stable operation of a boiler system.

  • PDF

화력발전소 보일러 제어루프의 시뮬레이션에 관한 연구 (A Study of Boiler Control Loop Simulation in Thermal Power Plant)

  • 이주현;이찬주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 B
    • /
    • pp.868-870
    • /
    • 1999
  • In this paper we obtain a discrete mathmatical model of a Boiler control system from expermental data, we find appropriate input signal and parameter estimation algorithm for identification of the Boiler control system in power plant. Under these conditions experimental data are collected from real system and parameters are estimated by the Recursive Least Square algorithm. The computer simulation results show the parameter estimation algorithm for identification and the effectiveness of controller design of the Boiler control system.

  • PDF

관류보일러 스팀 온도의 동역학 행렬 제어에 관한 연구 (A Study on Dynamic Matrix Control to Boiler Steam Temperature)

  • 김우헌;문운철
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2009년도 정보 및 제어 심포지움 논문집
    • /
    • pp.323-325
    • /
    • 2009
  • In this paper, we present simulation results of Dynamic Matrix Control(DMC) to a boiler steam temperature. In order to control of steam temperature, we choose the input-output variables and generate the step response model by each input variable's step test. After that, the control structure executes on-line control with optimization using step response model. Proposed controller is applied to the APESS(Doosan company's boiler model simulator) and it is observed that the simulation results show satisfactory performance of proposed control.

  • PDF