• Title/Summary/Keyword: Boiler System Control.

Search Result 209, Processing Time 0.022 seconds

Electromagnetic Indirect Induction Fluid Heating System using Series Resonant PWM Inverter and Its Performance Evaluations (직렬공진 PWM인버터를 이용한 전자간절유도가열 열유체 에너지시스템과 그 성능평가)

  • 김용주;김기환;신대철
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.1
    • /
    • pp.48-54
    • /
    • 2002
  • This paper is described the indirect induction heated boiler and induction heated hot air producer using the voltage-fed series resonant high-frequency inverter which can operate in the frequency range from 20 kHz to 50 kHz. A specially designed induction heater is composed of laminated stainless plates, which have many tiny holes and are interconnected by spot welding. This heater is inserted into the ceramic type vessel with external working coil. This working coil is connected to the inverter and turbulence fluid through this induction heater to moving fluid generates in the vessel. The operating performances of this unique appliance in next generation and its effectiveness are evaluated and discussed from a practical point of view.

Capacitance Characteristics of Fly Ash for Monitoring the Unburned Carbon Contained in Fly Ash (석탄회 미연탄소함량 동시측정을 위한 석탄회 정전용량 분석에 관한 연구)

  • 이재근;김장우;구재현;신진혁;김성찬;신희수;황유진
    • Journal of Energy Engineering
    • /
    • v.11 no.1
    • /
    • pp.67-73
    • /
    • 2002
  • The carbon-in-ash system for simultaneously monitoring the unburned carbon in fly ash produced in a coal-fired power plan is designed and evaluated using the domestic fly ash produced in the coal-fired power plant. Real time monitoring is very important to control the combustion of the boiler in the coal-fired power plant and the purification system for fly ash recycling. The carbon-in-ash system based on the capacitance measurement consists of a LCR meter, a duct collector and an electrode cell. The capacitance of fly ash increases linearly with increasing fly ash carbon contents. The water content in fly ash plays an important role on the ash capacitance. The empirical equation for predicting the content of unburned carbon in fly ash produced in the domestic Boryung, Hadong and Samchenpo coal-fired power plants can be derived in the range of carbon content 0-20%.

A Web-based Monitoring of Electrical Energy Consumption and Data Analysis of Smart Farm Facilities (스마트팜 전기 사용에 대한 웹기반 실시간 모니터링 시스템 운영 및 전력사용량 분석)

  • Lee, Mu Yeol;Sim, Sojeong;Kim, Eun-jeong;Han, Young-Soo
    • Journal of Bio-Environment Control
    • /
    • v.31 no.4
    • /
    • pp.366-375
    • /
    • 2022
  • The monitoring of electricity consumption using Internet of Things (IoT) technology is attracting attention as a technology to reduce operation costs of smart farms. In this study, we propose a method to apply a real-time electrical consumption monitoring system (the e-Gauge system) and utilization of the collected data real-time while a melon-producing smart farm is in operation. For this purpose, the electrical consumption data for the individual smart-farm facilities such as boilers, nutrient distribution systems, automatic controllers, circulation fans, boiler controllers, and other IoT-related utilities were collected during three months of melon cultivation period. By using the monitoring results, the electrical energy consumption pattern was analyzed as an example, and necessary considerations needed to optimally utilize the measurement data were suggested. This paper will be useful in lowering the technological implementation barriers for new researchers to build a electrical consumption monitoring system and reducing trial and errors in the usage of the generated data.

Evaluation on Termite Damage of the Traditional Wooden Building by Non-destructive Methods (비파괴 검사에 의한 전통목조건축물의 흰개미 열화 특성 조사)

  • Son, Dong-Won;Lee, Dong-heub
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.1
    • /
    • pp.21-29
    • /
    • 2008
  • The deterioration of Korean traditional wooden house located in seoul was estimated. This house was attacked by termite. To estimate damage status of buildings, non-destructive methods were applied. Some of the post needed to be replaced due to low strength, estimated by nondestructive methods. The house was installed with boiler heating facility, to use office and public education. This kind of heating system changed the environmental condition of the wooden house. The termite which attacked the house was classified as Reticulitermes speratus. Because of durability of wooden house effected by environment, control of the environmental condition is essential for maintaining the wooden house. The installation of modern facility to traditional wooden house should not change the traditional structure and do not effect to durability of wooden house.

Effect of Initial Volume of Hard Water and Contact Time on the Reduction of Calcium Ion Concentration using High Voltage Impulse Technique (고전압 임펄스 기술을 활용한 경도 제거에서 경수의 초기부피와 인가시간이 칼슘이온 농도에 미치는 영향)

  • Cho, Seung-Yeon;Kim, Tae-Hui;Chang, In-Soung;Hong, Woong-ki;Lee, June-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.7
    • /
    • pp.1066-1071
    • /
    • 2017
  • Recently high voltage impulse (HVI) technique has been extensively studied for desalting processes to control the $CaCO_3$ scale formation in industrial water practices such as power plant, boiler, and heat exchange operations. Investigation of the operational parameters for the HVI is important, however, those had not been reported yet. In this study, the effect of initial feed volume and contact time on reduction of calcium ion concentration by the HVI technique was investigated. Initial feed volumes of artificial hard water which contained 100 mg/L of $Ca^{2+}$, were set to 1, 2, and 3 L respectively. After 24hr of HVI contact with 12kV, $Ca^{2+}$ ion was reduced to 50, 29 and 19 % of their initial concentration, indicating that calcium removal increased as initial feed volume decreased. This implies the applied HVI pulse energy per unit mass of calcium is important parameter determining overall desalting efficiency. A series of extended operations of HVI up to 30 days verified the long term stability of the HVI system. The calcium ion declined to 40 mg/L after 2~3 days, and further reduction of calcium was not achieved, indicating that optimum operation time could be 2~3 days under these experimental conditions. Consequently, it was confirmed that the important operational parameter of HVI technique is initial feed volume and contact time as well as the applied voltage that was already proven in the previous study.

Field Survey of Greenhouse for Strawberry Culture -Case Study Based on Western Gyeongnam Area- (딸기재배 온실의 현장조사 분석 -서부경남 지역을 중심으로-)

  • Jeong, Young Kyun;Lee, Jong Goo;Yun, Sung Wook;Kim, Hyeon Tae;Yoon, Yong Cheol
    • Journal of Bio-Environment Control
    • /
    • v.27 no.3
    • /
    • pp.253-259
    • /
    • 2018
  • This study set out to select a system to realize an optimal environment for strawberry cultivation greenhouses based on data about the growth and development of strawberry and its environment and to provide basic data for the research of its improved productivity. For these purposes, the investigator conducted a field survey with greenhouses for strawberry cultivation in western Gyeongnam. The findings show that farmers in their fifties and sixties accounted for the biggest part in the age groups of strawberry farmers. While those who were under 50 were accounted for approximately 67.5%, those who were 60 or older accounted for 32.5%. As for cultivation experiences, the majority of the farmers had ten years of cultivation experiences or less with some having 30 years of cultivation experiences or more. All the farmers built an arch type single span greenhouse. Those who used nutrient solutions were about 75.0%, being more than those who used soil. All of the farmers that used a nutrient solution adopted an elevated hydroponic system. The single span greenhouses were in the range of 7.5~8.5m, 1.3~1.8m and 2.5~3.5m for width, eaves, and ridge height, respectively, regardless of survey areas. The rafters interval was about 0.7~0.8m. In elevated hydroponic cultivation, the width, height, and interval of the beds were about 0.25m, 1.2m and 1.0m, respectively. As for the strawberry varieties, the domestic ones accounted for approximately 97.5% with Seolhyang being the most favorite one at about 65.0%. As for the internal environment factors of greenhouses, 38 farmers measured only temperature and relatively humidity. As for hydroponics, the farmers used a hydroponics control system. Except for the farmers that introduced a smart farm system for temperature and humidity control, approximately 85.0% controlled temperature and humidity only with a control panel for side windows and ventilation fans. As for heating and heat insulation, all of the farmers were using water curtains with many farmers using an oil or electric boiler, radiating lamp or non-woven fabric, as well, when necessary.

Spot Heating Technology Development for Strawberry Cultivated in a Greenhouse by Using Hot Water Pipe (온수배관을 이용한 시설딸기 부분난방기술 개발)

  • Moon, Jongpil;Kang, Geum-Choon;Kwon, Jin-Kyung;Paek, Yee;Lee, Tae Seok;Oh, Sung-Sik;Nam, Myeong-Hyeon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.58 no.5
    • /
    • pp.71-79
    • /
    • 2016
  • The effects of spot heating for growing the strawberry cultivated in a plastic greenhouse during the winter that were estimated in Nonsan strawberry experiment station located in Chungnam. The temperature of water for heating was controlled by a electric hot water boiler and kept at the range of $22{\sim}24^{\circ}C$. Heating pipes were set up in root zone for root zone heating and very close to crown for crown heating. Spot heating effects were estimated by applying spot heating system in three test factors of heating root zone, crown only and crown plus root zone. The material for crown heating pipe was white low density polyethylene and the nominal diameter of that pipe was 16 mm. The material for root zone heating pipe was flexible stainless steel and the nominal diameter of that pipe was 15A. The flow rate of heating water circulation was 480 L/h and water circulation lasted for all day long. Temperatures, harvest yield by test beds were surveyed from Nov. 10, 2013 to Apr. 29, 2014. The temperature of crown spot for crown heating bed was at the range of $13.0{\sim}17.0^{\circ}C$ during the night and that of crown spot in control bed was at the range of $8.0{\sim}14.0^{\circ}C$. Also, the temperature of root zone for root zone heating bed was at the range of $18{\sim}21.0^{\circ}C$ and that of root zone in control bed was at the range of $13.0{\sim}15.0^{\circ}C$. The cumulative yield growth rate in earlier harvest period (from Dec. 20 to Mar. 15) of crown heating bed was 43% compared with that of control bed and the cumulative yield of crown plus root zone heating bed was 39 % and that of root zone heating bed was 39 %.

Analysis of Environment Factors in Pleurotus eryngii Cultivation House of Permanent Frame Type Structure (영구형 큰느타리버섯 재배사의 환경요인 분석)

  • Yoon Yong-Cheol;Suh Won-Myung;Lee In-Bok
    • Journal of Bio-Environment Control
    • /
    • v.15 no.2
    • /
    • pp.125-137
    • /
    • 2006
  • Pleurotus eryngii is one of the most promising mushrooms produced on the domestic farms. The quality as well as quantity of Eryngii is sensitively affected by micro climate factors such as temperature, relative humidity, $CO_2$ concentration, and light intensity. To safely produce high-quality Eryngii all the yew round, it is required that the environmental factors be carefully controlled by well designed structures equipped with various facilities and control systems. At the commercial mushroom cultivation houses of permanent frame type (A, B), this study was carried out to find out reasonable range of each environmental factor and yield together with economic and safe structures influencing on the optimal productivity of Eryngii. This experiment was conducted for about two-year ken Nov. 2003 to Dec. 2005 in cultivation house. Ambient temperature during the experiment period was not predominantly different from that of a normal year. The capacity of the hot water boiler and the piping systems were not enough. Because the capacity of electric heater and air circulation were not enough, air temperatures in cultivation house before improvement of system were maintained somewhat lower than setting temperature, and maximum air temperature difference between the upper and lower growth stage during a heating time period was about 5.1. But the air temperatures after system improvement were maintained within the limits range of setting temperature without happening stagnant of air. Air temperature distribution was generally distributed uniform. Relative humidity in cultivation house before , improvement was widely ranged about $44{\sim}100%$. But as the relative humidity after improvement was ranged approximately $80{\sim}100%$, it was maintained within the range of relative humidity recommended. And $CO_2$ concentration was maintained about $400{\sim}3,300mg{\cdot}L^{-1}$ range. The illuminance in cultivation house was widely distributed in accordance with position, and it was maintained lower than the recommended illuminance range $100{\sim}200lx$. The acidity of midium was some lower range than the recommend acidity range of pH $5.5{\sim}6.5$. The yield was relatively ununiform. In case of bottle capacity of 1,300cc, the mushroom of the lowest grade was less than 3%. The consumption electric energy was quite different according to the cultivation season. The electric energy consumed during heating season was much more than that of cooling season.

Analysis of Air Temperature and Humidity Distributions and Energy Consumptions according to Use of Air Circulation Fans in a Single-span Greenhouse (단동온실 내 공기순환팬 사용에 따른 온습도 및 에너지소비량 비교 분석)

  • Lee, Tae Seok;Kang, Geum Choon;Kim, Hyung Kweon;Moon, Jong Pil;Oh, Sung Sik;Kwon, Jin Kyung
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.276-282
    • /
    • 2017
  • The aim of this study was to compare and analyze air temperature and humidity distribution and energy consumptions according to using air circulation fans in single-span greenhouses. The greenhouses located in Cheongnam-myeon, Cheongyang-gun, Chungcheongnam-do, Korea. There were cherry tomatoes in the greenhouses and the size of greenhouses was as follows;ridge height : 3.2 m, wide : 6 m, length : 95 m. The heating system was composed of a hot-water boiler and 6 FCUs(Fan Coil Unit)-4 FCUs were on bottom with duct and 2 FCUs were installed at 2.0 m. A total of 18 air circulation fans(impeller's diameter : 230 mm) were bilaterally arranged in 2 rows in the experimental greenhouse. The sensors for measuring air temperature and humidity were located at a quarter and three quarters of a length. The height of sensors were 0.8 m, 1.8 m. To calculate energy consumption in greenhouses, water temperature at inlet and outlet in a water pump, volume of water were measured. Form February 3rd to March 23th, temperature, humidity and energy consumptions were measured during heating time(6pm~7am). In a greenhouse without fans, the average differences of temperature and humidity were $0.75^{\circ}C$, 2.31%, respectively. The operation of fans showed their differences to $0.42^{\circ}C$, 1.8%. The standard deviation of temperature and humidity between measuring points in the greenhouse with fans was lower than the greenhouse without fans. Total energy consumptions in a greenhouse without fans were 4,673 kWh. In the greenhouse with fans, the total energy consumptions were 4,009 kWh. The energy consumptions in a greenhouse with fans 14.2% were less than the greenhouse without fans. Therefore, air circulation makes temperature and humidity uniform and saves energy consumptions for heating.