• Title/Summary/Keyword: Boiler Combustion System

Search Result 93, Processing Time 0.026 seconds

Numerical Simulation for Flow Optimization of De-NOx Selective Catalytic Reactor (배가스 탈질 설비의 유동해석 사례)

  • Go, Young-Gun;Ryu, Chang-Kook;Choi, Sang-Min
    • 한국연소학회:학술대회논문집
    • /
    • 2001.06a
    • /
    • pp.99-105
    • /
    • 2001
  • For the design of selective catalytic reactors of NOx by $NH_3$, engineering approach can be performed to determine the reactor shape, mixing device and $NH_3$ injection system. This study shows the optimization of guide vanes to improve the flow pattern near the catalyst layer of SCR in a untility boiler. By varying their spacings and shapes, flow performance of guide vanes was analyzed to achieve an uniform velocity distribution which increases the NOx convesion efficiency, and a flow direction normal to the layer which minimises the erosion by the dust in the flue gas. Including these results, experimental and numerical studies for the SCR design were discussed.

  • PDF

Heavy Oil Combustion Characteristics of the Hot Water Boiler System fueled by Rice Husk and Heavy Oil (왕겨와 중유연료를 겸용으로 이용하는 온수보일러 시스템에서 중유 연소특성)

  • 박승제;김동선
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.02a
    • /
    • pp.217-222
    • /
    • 2002
  • 본 연구에서는 가연성 폐기물을 이용한 시설원예 난방에너지 공급시스템 개발을 위하여 대형 온실 난방이나 RPC 시설에 이용할 수 있는 왕겨와 중유 겸용연소 시스템에서 중유의 연소 및 성능 특성을 분석하고자 하였다. 중요 인자로는 분사노즐의 크기(2.0, 2.25, 2.5, 3.0 GPH)와 진공압력(375, 500, 625, 750 Pa)을 설정하였으며 이에 대한 결과를 요약하면 다음과 같다. 1.진공압력 500Pa조건에서 연료 공급율이 증가할수록 연소실 벽체 열교환기 효율은 감소하고 폐열회수 열교환기와 사이클론 열교환기의 효율이 증가하였으며, 노즐 2.5GPH에서 진공압력이 커질수록 연소실 하부의 온도가 감소하였고 연소실 상부에서는 비슷한 경향을 보였다. 2, 연소온도특성, 열효율, 배기가스 성분분석 등의 결과로 볼 때 최적의 연소 조건은 노즐 2.5GPH는 진공압력 375Pa, 노즐3.0GPH는 진공압력 500Pa과 625Pa 사이로 판단되었다. 3. 배연가스내의 대기오염 성분은 모든 실험처리에서 CO 함량은 거의 없고 SO$_2$와 NO$_{x}$의 함량 또한 일반 보일러 허용기준을 만족하는 것으로 나타났다.

  • PDF

The study of plant application at flame management system with flame monitoring for pulverized coal firing boiler of thermal power plant (발전용 미분탄 연소 보일러 화염감시장치의 현장적용에 관한 연구)

  • Baeg, Seung-Yeob;Kim, Seung-Min
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.535-537
    • /
    • 2004
  • The flame image processing and it's analysis system has been developed for optimal coal firing of thermal power plant, especially for reducing NOx and safe operations. We aimed at gaining the relationship between burner flame image, emissions of NOx and LOI(Loss on ignition) in furnace by utilizing the flame image processing methods. And the relationship determines quantitatively the conditions of combustion on the individual burners. The test was conducted on Samchonpo thermal power plant #4 unit(560MW) of KOSEP which has 24 burners. The system simplified the burner adjustment works in accordance with the real time trending of flame behavior like NOx profiles and unburned carbon profiles for individual burners. But, This kind of conventional method increases the cost as the number of burner are increased. Also there is a difficulty to measure exhausted gas of each burner because of measurement errors. This paper intends to propose the useful "Flame Monitoring System" that can find Low NOX and LOI at the upper furnace and to compare with the conventional System.

  • PDF

A Study of Chemical Properties and Fusibility of Korean Anthracite Coal Ash (국내 무연탄회의 화학조성 및 용융특성에 관한 연구)

  • Park, Cheol-Woo;Lee, See-Hoon;Shon, Eung-Kwon
    • Analytical Science and Technology
    • /
    • v.5 no.4
    • /
    • pp.433-441
    • /
    • 1992
  • Chemical composition and fusibility of coal ash were measured for 23 Korean anthracite coals. The relationship between chemical properties and fusion temperature of coal ash was investigated. The slagging and fouling in firing the pulverized coal for boiler was assessed for the coal samples. It was found that most ashes contained more than 80% of $SiO_2$ and $Al_2O_3$ whereas less than 1% of $Na_2O$. And also fusion temperature of ashes occured relatively higher for Korean coals. Therefore it can be predictable that the slagging and fouling formation has a little problem in a pulverized coal firing system. A base/acid ratio did show a good correlation with fusion temperature for these coal ashes.

  • PDF

A Study on Characteristics of Exhaust Gas Emissions of Water-Bunker Oil Mixed by Homogenizer (균질기에 의해 혼합된 물-벙커유의 배기가스 배출 특성에 관한 연구)

  • Choi, Jung-Sik;Han, Sang-Goo;Choi, Jae-Hyuk;Park, Sang-Kyun;Park, Ro-Seong;Kim, Dae-Hun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.19 no.5
    • /
    • pp.518-524
    • /
    • 2013
  • In this study, we conducted a study on characteristics of exhaust gas emissions from boiler when water-bunker oil mixed by homogenizer was burned in boiler. The results showed that NOx concentration and CO concentration of the homogenized bunker oil was decreased by 19% and 54% compared to pure bunker oil pretreatment was not being performed. And, in the case of water-bunker A oil, the NOx concentration was decreased with increasing water mixing ratio in bunker A oil. In particular, the NOx concentration in exhaust gas of 20 %water-80 %bunker A oil decrease by 45 % compared with pure bunker-A. However, the CO concentration in exhaust gas of 20 %water-80 %bunker A oil shows irregular changes. This means that the mixing of water more than a certain amount can cause a decrease in combustion performance. From this result, it can be found that critical mixing ratio of water in bunker A oil for normal combustion is 15% in this study. Deposition amount of soot that is collected in the vicinity of the chimney was decreased with increasing water mixing ratio.

Development of Gear-Type Vane Dampers to Replace Link-Type Vane Dampers in Marine FD Fans (선박용 강제통풍 팬의 기어식 베인댐퍼 성능평가)

  • Hur, Nam-Soo;Jang, Sung-Cheol;Lee, Kyung-Jun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.19 no.4
    • /
    • pp.216-222
    • /
    • 2016
  • Thus, this study aimed to develop a gear-type vane damper in order to replace the link-type vane damper. To achieve this goal, the torque generated in a gear-type vane damper was analyzed, and a structural analysis was conducted. In addition, the fluid flow was analyzed according to the changes in the vane's angle, and experimental tests such as a dry-heat test and cold test were conducted considering the operating conditions of the vessels. Moreover, an appropriate actuator was selected for the developed gear-type vane damper, and studies on the reduction in the backlash due to the facing-pressure adjustment length and flow rate and leakage test due to the vane's angle were conducted.

Capacitance Characteristics of Fly Ash for Monitoring the Unburned Carbon Contained in Fly Ash (석탄회 미연탄소함량 동시측정을 위한 석탄회 정전용량 분석에 관한 연구)

  • 이재근;김장우;구재현;신진혁;김성찬;신희수;황유진
    • Journal of Energy Engineering
    • /
    • v.11 no.1
    • /
    • pp.67-73
    • /
    • 2002
  • The carbon-in-ash system for simultaneously monitoring the unburned carbon in fly ash produced in a coal-fired power plan is designed and evaluated using the domestic fly ash produced in the coal-fired power plant. Real time monitoring is very important to control the combustion of the boiler in the coal-fired power plant and the purification system for fly ash recycling. The carbon-in-ash system based on the capacitance measurement consists of a LCR meter, a duct collector and an electrode cell. The capacitance of fly ash increases linearly with increasing fly ash carbon contents. The water content in fly ash plays an important role on the ash capacitance. The empirical equation for predicting the content of unburned carbon in fly ash produced in the domestic Boryung, Hadong and Samchenpo coal-fired power plants can be derived in the range of carbon content 0-20%.

Computational Fluid Dynamic Analysis for Improving the Efficiency of Desulfurization System for the Wet Flue Gas (습식 배연탈황 시스템의 효율 향상을 위한 전산해석)

  • Hwang, Woo-Hyeon;Lee, Kyung-Ok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.2
    • /
    • pp.161-171
    • /
    • 2014
  • In this paper the flow dynamics of the flue gas equipment in the desulfurization system was numerically analyzed by simulating the problems for the turbulent and combustion flow from Induced Draft Fan(I.D.Fan) outlet to Booster Up Fan(B.U.Fan) inlet using the commercial CFD software of CFD-ACE+ in CFDRC company for Computational Fluid Dynamic Analysis. The guide vane of this section was examined for the minimum pressure loss and the uniform flow dynamic to B.U.Fan with the proper velocity from I.D,Fan exit to B,U,Fan inlet section at the boiler both the maximum continuous rating and the design base. The guide vanes at I,D.Fan outlet and B.U.Fan inlet were removed and modified by numerical simulation of the CFD analysis. The flue gas at the system had the less pressure loss and the uniform flow dynamics of the flow velocity and flow line by comparing with the old design equipment.

Combustion Characteristic Study of LNG Flame in an Oxygen Enriched Environment (산소부화 조건에 따른 LNG 연소특성 연구)

  • Kim, Hey-Suk;Shin, Mi-Soo;Jang, Dong-Soon;Lee, Dae-Geun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.1
    • /
    • pp.23-30
    • /
    • 2007
  • The ultimate objective of this study is to develop oxygen-enriched combustion techniques applicable to the system of practical industrial boiler. To this end the combustion characteristics of lab-scale LNG combustor were investigated as a first step using the method of numerical simulation by analyzing the flame characteristics and pollutant emission behaviour as a function of oxygen enrichment level. Several useful conclusions could be drawn based on this study. First of all, the increase of oxygen enrichment level instead of air caused long and thin flame called laminar flame feature. This was in good agreement with experimental results appeared in open literature and explained by the effect of the decrease of turbulent mixing due to the decrease of absolute amount of oxidizer flow rate by the absence of the nitrogen species. Further, as expected, oxygen enrichment increased the flame temperatures to a significant level together with concentrations of $CO_2$ and $H_2O$ species because of the elimination of the heat sink and dilution effects by the presence of $N_2$ inert gas. However, the increased flame temperature with $O_2$ enriched air showed the high possibility of the generation of thermal $NO_x$ if nitrogen species were present. In order to remedy the problem caused by the oxygen-enriched combustion, the appropriate amount of recirculation $CO_2$ gas was desirable to enhance the turbulent mixing and thereby flame stability and further optimum determination of operational conditions were necessary. For example, the adjustment of burner with swirl angle of $30\sim45^{\circ}$ increased the combustion efficiency of LNG fuel and simultaneously dropped the $NO_x$ formation.

Effect of Coagulants on the Behavior of Ultra Fine Dust in a Coal Firing Boiler (석탄 화력 보일러에서의 응집제 이용에 따른 초미세먼지 거동)

  • Ryu, Hwanwoo;Song, Byungho
    • Applied Chemistry for Engineering
    • /
    • v.31 no.1
    • /
    • pp.84-89
    • /
    • 2020
  • Particulate matters of PM2.5, particularly focusing on 0.1~1 ㎛ decrease the efficiency of dust-collector due to the brownian-motion. This study is to verify the effect of coagulant on the particle size distributions of potassium and PM2.5. The activated coagulant was spayed to the coal fired fluidized bed combustion boiler by the weight ratio of 1,200 : 1 = coal : coagulant, and the size distributions of captured particles at both the cyclone (FP) and electrostatic precipitator (EP) were measured. As the result of XRP analysis, the potassium content of FP increased to 13.33% (averagely from 1.65% to 1.87%) and, in EP at 17.68% (averagely from 1.65% to 2.03%). And it was confirmed by the particle size distribution analyzer and SEM image analysis that the distribution rates of PM2.5 decreased at 89.53% on average in FP, and at 88.57% in EP. The total dust concentration (mg/㎥) confirmed by tele-monitering system (TMS) decreased during the primary test from 2.6 to 1.7~1.9 and also the secondary test from 2.9 to 1.7~1.9.