• Title/Summary/Keyword: Body valve

Search Result 237, Processing Time 0.02 seconds

Ahmed Valve Implantation for Early Glaucoma Treatment in Dogs (개의 초기 원발성 녹내장안에서 Ahmed valve 이식술의 적용)

  • Park, Shin-Ae;Jeong, Man-Bok;Park, Young-Woo;Kim, Won-Tae;Kim, Se-Eun;Seo, Kang-Moon
    • Journal of Veterinary Clinics
    • /
    • v.25 no.5
    • /
    • pp.385-390
    • /
    • 2008
  • The purpose of this study was to compare the long term prognosis of Ahmed valve implantation and medical therapy in dogs with early primary glaucoma. The medical records of dogs with early primary glaucoma from the Veterinary Medical Teaching Hospital of Seoul National University between January 2005 and May 2008 were reviewed. Five dogs underwent Ahmed valve implantation and medical therapy was performed in six dogs. Breeds of the dogs included Shih Tzu(n = 7), American cocker spaniel(n = 2), and miniature poodle(n = 2). Adequate intraocular pressure(IOP) was better maintained in the Ahmed valve implantation group than in the medical treatment group throughout the follow-up period. Mean time for vision loss to develop after treatment in the Ahmed valve implantation group($198.0{\pm}115.4$ days) was significantly longer than that in medical treatment group($43.2{\pm}30.4$ days, p < 0.05). Post-operative complications included occlusion of the tube by fibrin in the anterior chamber (n = 1), fibrous capsule about the episcleral base of the device(n = 1), and dislocation of the valve body(n = 1). It is considered that Ahmed valve implantation is more effective strategy to control IOP and maintain vision than medical treatment in early glaucomatous dogs.

Serum serotonin concentration in lean and obese dogs with myxomatous mitral valve disease

  • Kim, Kyu-Tae;Park, Hee-Myung;Hyun, Changbaig;Seo, Kyoung-Won;Song, Kun-Ho
    • Korean Journal of Veterinary Research
    • /
    • v.56 no.4
    • /
    • pp.205-208
    • /
    • 2016
  • The aim of the present study is to investigate the potential influence of obesity as a factor in 5-hydroxytryptamine (5-HT) concentration in myxomatous mitral valve disease (MMVD) dogs. Fifty-five client-owned dogs were enrolled in a randomized trial. Dogs were classified by echocardiography into healthy (control), mild, and moderate to severe MMVD groups. Each group was subclassified by using a 9-point body condition score (BCS); lean (BCS 5-6/9) and obese groups (BCS 7.5-9/9). Dogs with moderate to severe MMVD had lower serotonin (5-HT) concentrations than the control group (p = 0.03). Dogs with moderate to severe MMVD (p = 0.017) had lower serum 5-HT concentrations than the control group in the obese group (BCS 7.5-9/9). Significant difference was found between the lean and obese groups (p = 0.015) which are not consider severe in the MMVD group. These results suggested that 5-HT concentration was decreased with the increasing severity of MMVD, and obesity might be taken into consideration when interpreting the serotonin concentration in MMVD dogs.

Numerical Study on the Strength Safety of a Fuse Cock Valve (퓨즈콕 밸브의 강도안전성에 관한 수치적 연구)

  • Kim, Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.5
    • /
    • pp.1-6
    • /
    • 2015
  • In this paper, the strength safety of a fuse cock main body has been analyzed by the finite element method. The stress and displacement behaviour characteristics have been investigated for thickness variations at the region of (T) between a ball valve and a fuse cock safety connector. The FEM analyzed results recommend that the optimized thickness at the region of (T) is from 1.55mm to 1.6mm for the supplied gas pressure of 1.5~3.5MPa. This is considered for the optimized strength safety and light weight of a fuse cock main body.

Impact of postoperative duration of Aspirin use on longevity of bioprosthetic pulmonary valve in patients who underwent congenital heart disease repair

  • Hwang, Tae-Woong;Kim, Sung-Ook;Lee, Sang-Yun;Kim, Seong-Ho;Choi, Eun-Young;Jang, So-Ick;Park, Su-Jin;Kwon, Hye-Won;Lim, Hyo-Bin;Lee, Chang-Ha;Choi, Eun-Seok
    • Clinical and Experimental Pediatrics
    • /
    • v.59 no.11
    • /
    • pp.446-450
    • /
    • 2016
  • Purpose: Generally, aspirin is used as a protective agent against thrombogenic phenomenon after pulmonary valve replacement (PVR) using a bioprosthetic valve. However, the appropriate duration of aspirin use is unclear. We analyzed the impact of postoperative duration of aspirin use on the longevity of bioprosthetic pulmonary valves in patients who underwent repair for congenital heart diseases. Methods: We retrospectively reviewed the clinical data of 137 patients who underwent PVR using a bioprosthetic valve between January 2000 and December 2003. Among these patients, 89 were included in our study and divided into groups I (${\leq}12$ months) and II (>12 months) according to duration of aspirin use. We analyzed echocardiographic data from 9 to 11 years after PVR. Pulmonary vale stenosis and regurgitation were classified as mild, moderate, or severe. Results: The 89 patients consisted of 53 males and 36 females. Their mean age was $14.3{\pm}8.9$ years (range, 2.6-48 years) and body weight was $37.6{\pm}14.7kg$ (range, 14-72 kg). The postoperative duration of aspirin use was $7.3{\pm}2.9$ months in group I and $32.8{\pm}28.4$ months in group II. However, no significant difference in sex ratio, age, body weight, type of bioprosthetic valve, and number of early redo-PVRs. In the comparison of echocardiographic data about 10 years later, no significant difference in pulmonary valve function was found. The overall freedom rate from redo-PVR at 10 years showed no significant difference (P=0.498). Conclusion: Our results indicated no benefit from long-term aspirin medication (>6 months) in patients who underwent PVR with a bioprosthetic valve.

Development of the low emission gasoline engine (국산 가솔린 엔진용 저배기공해 system에 관한 연구)

  • 성낙원;정용일;우세종
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.8 no.3
    • /
    • pp.16-27
    • /
    • 1986
  • In this study, low emission gasoline engine system is developed utilizing an EGR valve, 3 way catalytic converter and electronic fuel injection system. EGR was controlled by a needle valve and optimized at the engine conditions. Throttle body fuel injection system is used for fueling. When the engine was operated at constant speed by the electronic engine control system with the 3 way catalytic converter, th emissions were reduced by 50 to 90% in volume depending on he engine operating conditions.

  • PDF

Dynamic Analysis of Engine Valve Train with Flexible Multibody Model Considering Contact between Components (부품간의 접촉을 고려한 유연체모델을 이용한 엔진 밸브트레인의 동특성 해석)

  • Hwang, Won-Gul;Sung, Won-Suk;Ahn, Ki-Won
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.1
    • /
    • pp.125-132
    • /
    • 2011
  • The dynamic characteristics of valve train are responsible for the dynamic performances of engine. We derived the equation of motion for 6 degrees of freedom model of the valve train. Computer model is also developed with flexible multibody model considering contact between components. The simulation results with these two models are compared with experimental results. We investigated the effect of the two spring models, TSDA (Translational Spring Damper Actuator) element and flexible body model, on the valve behavior and spring force. It is found that the dynamic behavior of the two models are not very different at normal operational velocity of the engine. By modeling contact between cam and tappet, the stress distributions of the cam were found. Using stress distribution obtained, contact width and contact stresses of the cam surface were calculated with Hertz contact theory.

Overflow Valve and Performance Evaluation System for Diesel Cars based on Spring Load (스프링하중을 고려한 디젤차량용 오버플로우 밸브 성능평가)

  • Yoon, Dal-Hwan
    • Journal of IKEEE
    • /
    • v.20 no.2
    • /
    • pp.200-204
    • /
    • 2016
  • In this paper, we have estimated the performance of an overflow valve for EURO type CRDI(common rail direct injection) engine. In order to implement the overflow valve with friendly circumstance, it is necessity for considering spring load. Especially, the performance evaluation of diesel car with accuracy control will be considered a mileage improvement and circumstance regulation. In order to evaluate the performance of overflow valve, The leak test system checks the pressure, switching time and operating time under 3.0 bar below 100 cc, 3.3 bar among 150 cc and 200 cc, finally 4.0 bar upper 250 cc.

A Numerical Study on the Blood Flow through a Disc Type Heart Valve (원판형 심장판 주위의 혈액 흐름에 대한 수직 해석)

  • 박영필;이신재
    • Journal of Biomedical Engineering Research
    • /
    • v.2 no.2
    • /
    • pp.89-102
    • /
    • 1981
  • The recirculating flows which occur in the prosthetic heart valve have been known to cause several diseases in the human body. And the recent studies show that the shear stress at the wall of the artery is also very important factor in the formation of thrombus. And many studies knave been devoted in obtaining more information about the blood flow through the prosthetic heart valve. In this Paper, the steady axisymmetric flow through the Disc-Type Heart Valve is studied by using the numerical method. The geometry of the Disc-Type Heart Valve is simplified, and the flow is assumed to be steady axisymmetric flow. The vorticity transport equation derived from the Wavier-Stoke's equation is used as the governing equation, and the explicit finite difference method is used to obtain the steady state solution. The results for several Reynolds numbers show that the recirculating flow becomes large as the Remolds number increases. Furthermore, it can be shown that the magnitudes of the vorticity and the stresses are also increased with the Reynolds number, but there is only a little change in their configurations of distribution and in their positions of maximum values.

  • PDF

Structural Analysis of 1000A Butterfly Valve Components (1000A용 버터플라이 밸브 주요부품의 구조해석)

  • Kong, Yu-Sik;Kim, Seon-Jin;Jung, Min-Hwa
    • Journal of Ocean Engineering and Technology
    • /
    • v.23 no.1
    • /
    • pp.140-145
    • /
    • 2009
  • This paper deals with a stability evaluation of a butterfly valve using the body and disc of a valve seat. The experimental results of a strength evaluation are shown using STS316 stainless steel and spheroidal graphite cast iron (GCD450). The disc material was made from GCD450. The results of the strength analysis are as follows: Ultimate tensile strength 485MPa, Yield strength 370 MPa, Young's modulus $1.1{\times}10^5$, and Poisson's ratio v = 0.28. For the results of the disc analysis, the safety factor was about 4. This shows that a design was derived that satisfied the requirements of structural safety. However, some problems, such as the deflection and deformation of the disc, may occur when the sea water has back flow with a high pressure.

Numerical Study on the Leakage Safety of O-rings for a LPG Cylinder Valve (LPG 용기 밸브용 O-링의 누설안전성에 관한 해석적 연구)

  • Kim, Chung-Kyun;Kim, Do-Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.2 s.35
    • /
    • pp.37-42
    • /
    • 2007
  • This paper presents the leakage safety of two O-rings, which are located at the rectangular groove between a valve body and a valve stem. The leakage safety analysis of 0-ring seals has been computed as functions of a compression set and a liquefied petroleum gas pressure of a LPG cylinder using a FEM program, MARC. The FEM computed results indicate that the loads from the filling pressure of $8kg/cm^2$ to the upper limit of the safety valve, $24.8kg/cm^2$ work safely according to the pressure vessel code. But two O-rings should consider the aging effects for an increased safety of the o-ring.

  • PDF