• Title/Summary/Keyword: Body temperature measurement

Search Result 223, Processing Time 0.031 seconds

Temperature thread multiscale finite element simulation of selective laser melting for the evaluation of process

  • Lee, Kang-Hyun;Yun, Gun Jin
    • Advances in aircraft and spacecraft science
    • /
    • v.8 no.1
    • /
    • pp.31-51
    • /
    • 2021
  • Selective laser melting (SLM), one of the most widely used powder bed fusion (PBF) additive manufacturing (AM) technology, enables the fabrication of customized metallic parts with complex geometry by layer-by-layer fashion. However, SLM inherently poses several problems such as the discontinuities in the molten track and the steep temperature gradient resulting in a high degree of residual stress. To avoid such defects, thisstudy proposes a temperature thread multiscale model of SLM for the evaluation of the process at different scales. In microscale melt pool analysis, the laser beam parameters were evaluated based on the predicted melt pool morphology to check for lack-of-fusion or keyhole defects. The analysis results at microscale were then used to build an equivalent body heat flux model to obtain the residual stress distribution and the part distortions at the macroscale (part level). To identify the source of uneven heat dissipation, a liquid lifetime contour at macroscale was investigated. The predicted distortion was also experimentally validated showing a good agreement with the experimental measurement.

A Study on the Evaluation of Human Alertness for Flight Safety (비행안전을 위한 조종사의 생체 활성도 평가에 관한 연구)

  • 최승호;이달호
    • Proceedings of the ESK Conference
    • /
    • 1998.04a
    • /
    • pp.167-172
    • /
    • 1998
  • Methods of evaluating the physiological activity of the living body are EEG, EOG, Heart rate, and Rectal temperature, etc. In the study of Hagiwara and Araki(1993), they found positive correlations among performance test, physiological measurement, and subjective feeling measurement. Human alertness of pilot directly influences on the flight performance that accomplishes a lot of vigilance task and procedure execution in flight. Accordingly, this paper deals with the quantitative and objective performance test based on tracking error and reaction time by means of the new computer test program into which the perception-motion system of human beings is applies. Throughout this experiment using performance thst, the results suggest that performance capability in state of sleep deprivation 2 hours and alcoholic 0.05 .apaprox. 0.06% in blood were more impaired than one in a normal state, and they further showed statistically significant differences between them, which were influenced by impairment factors of body regulation and pilot's grade. We also obtained the prediction value and the 95% confidence interval of tracking error and reaction time at the normal state for the purpose of distinguishing performance capability between the normal state and the abnormal state. And it is ecpected that the evaluation of human alertness using performance test will be applied to the quantitative assessment of an each pilot's realistic consciousness/attention, and will lead a flight commander to the accurate decision of mission approval prior to a flight.

  • PDF

A Fully Integrated SoC for Smart Capsule Providing In-Body Continuous pH and Temperature Monitoring

  • Liu, Heng;Jiang, Hanjun;Xia, Jingpei;Chi, Zhexiang;Li, Fule;Wang, Zhihua
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.5
    • /
    • pp.542-549
    • /
    • 2016
  • This paper presents a SoC (System-on-a-Chip) dedicated for a single-chip smart capsule which can be used to continuously monitor human alimentary canal pH and temperature values. The SoC is composed of the pH and temperature sensor interface circuit, a wireless transceiver, the power management circuit and the flow control logic. Fabricated in $0.18{\mu}m$ standard CMOS technology, the SoC occupies a die area of ${\sim}9 mm^2$. The SoC consumes 6.15 mW from a 3 V power supply, guaranteeing the smart capsule battery life is no less than 24 hours when using 50 mAh coin batteries. The experimental results show that measurement accuracy of the smart capsule is ${\pm}0.1$ pH and ${\pm}0.2^{\circ}C$ for pH and temperature sensing, respectively, which meets the requirement of in-body pH and temperature monitoring in clinical practice.

The Physiological Responses of Material-improved Working Clothes for Construction Site Worker (건설현장 작업복의 소재 기능성 향상에 따른 생리반응)

  • Kim, Seong-Suk;Kim, Hee-Eun
    • Fashion & Textile Research Journal
    • /
    • v.13 no.5
    • /
    • pp.752-758
    • /
    • 2011
  • In this paper, experiments to develop working clothes and evaluated, including the current and material-improved working clothes in relation to physiological functionality measurement. Experiments were conducted on subjects after wearing working clothes in an climate chamber, and the thermo-physiological response, such as human body temperature, micro-climate within the clothes, blood pressure, heart rate were measured. In this manner, the physiological functionality of improved working clothes was compared with that of current working clothes and evaluated. The summary of obtained results is as follows: For physiological functionality evaluation through material-improved working clothes, P working clothes showed significantly lower rectal temperature than C working clothes. For mean skin temperature, P's skin temperature was significantly higher than C's in the second half of the experiment. P working clothes's temperature around the thighs in Micro climate was significantly lower than that of the C working clothes. Also, humidity within the clothes showed similar trends. During the exercise period, C working clothes showed higher blood pressure than P, but P showed higher heart rates than C. Also, the oxygen uptake amount was higher in C than P during the exercise period, it explains that the energy consumption amount of P working clothes was smaller than that of C working clothes. Of the subjective evaluation, for temperature sensation, workers wearing P working clothes felt cooler. For humidity, C working clothes showed more humidity. For comfort, P working clothes were better, and for sense of fatigue, workers felt less tired wearing P working clothes. From results above, we can see that physiological functionality improved in the material-improved working clothes in the working clothes for construction site workers. The improvement of working clothes through functionality improvements not only will provide personal pleasantness to constriction site workers, but will also generate efficiency and productivity improvements at construction sites. All in all, the continuous study of functionality improvements in working clothes taking into consideration the human body's physiological responses is required.

Accuracy, Precision, and Validity of Fever Detection using Non-invasive Temperature Measurement in Adult Coronary Care Unit Patients with Pulmonary Catheters (폐동맥관을 부착하고 있는 심장수술 환자에 대한 비침습적 체온측정 방법의 정확도, 정밀도 및 발열감별 타당도)

  • Joo, Ga-Eul;Sohng, Kyeong-Yae
    • Journal of Korean Academy of Nursing
    • /
    • v.42 no.3
    • /
    • pp.424-433
    • /
    • 2012
  • Purpose: To investigate the accuracy, precision and validity of fever detection of tympanic membrane (TM), temporal artery (TA) and axillary temperature (AT) compared with pulmonary artery temperature (PA). Methods: Repeated-measures design was conducted for one year on 83 adult cardiac care unit patients with pulmonary artery catheters after open heart surgery. Sequential temperature measurements were taken three times at 20-minute intervals. Accuracy, precision, repeatability, and validity of fever detection were analyzed. Results: Mean pulmonary artery temperature was $37.04^{\circ}C$ (SD $0.70^{\circ}C$). The mean (SD) offsets from PA, with the mean reflecting accuracy and SD reflecting precision, were $-1.31^{\circ}C$ ($0.75^{\circ}C$) for TA, $-0.20^{\circ}C$ ($0.24^{\circ}C$) for TM, and $-0.97^{\circ}C$ ($0.64^{\circ}C$) for AT. Percentage of pairs with differences within ${\pm}0.5^{\circ}C$ was 9.6% for TA, 19.7% for AT, and 91.6% for TM. Repeated measurements with all three methods had mean SD values within $0.04^{\circ}C$. Sensitivity, specificity, and positive and negative predictive values of tympanic measurements were 0.76, 1.0, and 1.0, and 0.90, respectively. Conclusion: Results show that TM best reflects PA, and is most consistent, accurate, and precise. AT tends to underestimate PA, and TA is least accurate and precise. Therefore tympanic membrane measurement is a reliable alternative to other non-invasive methods of measuring temperatures.

Multidimensional Hydrodynamic and Water Temperature Modeling of Han River System (한강 수계에서의 다차원 시변화 수리.수온 모델 연구)

  • Kim, Eun-Jung;Park, Seok-Soon
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.6
    • /
    • pp.866-881
    • /
    • 2012
  • Han River is a complex water system consisting of many lakes. The water quality of Lake Paldang is significantly affected by incoming flows, which are the South and North branches of the Han River, and the Kyungan Stream. In order to manage the water quality of the Lake Paldang, we should consider the entire water body where the incoming flows are included. The objectives of this study are to develop an integrated river and lake modeling system for Han River system using a multidimensional dynamic model and evaluate the model's performance against field measurement data. The integrated model was calibrated and verified using field measurement data obtained in 2007 and 2008. The model showed satisfactory performance in predicting temporal variations of water level, flow rate and temperature. The Root Mean Square Error (RMSE) for water temperature simulation were $0.88{\sim}2.13^{\circ}C$ (calibration period) and $1.05{\sim}2.00^{\circ}C$ (verification period) respectively. And Nash-Sutcliffe Efficiency (NSE) for water temperature simulation were 1089~0.98 (calibration period) and 0.90~0.98 (verification period). Utilizing the validated model, we analyzed the spatial and temporal distributions of temperature within Han River system. The variations of temperature along the river reaches and vertical thermal profiles for each lakes were effectively simulated with developed model. The suggested modeling system can be effectively used for integrated water quality management of water system consisting of many rivers and lakes.

Sportswear Physiological Optimization: Effects of Clothing ease, local heating and materiales (운동복의 기능성과 쾌적성에 관한 연구)

  • Lee Young Suk;An Tae Whan
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.15 no.2 s.38
    • /
    • pp.127-138
    • /
    • 1991
  • The aim of the present stud)r has been to obtain new and additional data allolwing a better design of sports garments as well as a better choice among some materiales, through measure-ment of body surface changes in the upper trunk in movement, measurement on the effects of local heating on other parts of the body and measurement of the thermal resistance of 6 types of materials applied on a manikin. In the first experiment, the upper trunk was divided in 32 Parts, the surface of which was measured by the tape method for two upper limb positions: extension at $90^{\circ}$ and $180^{\circ}$. In the second experiment, skin temperature, local thermal sensations and whole body thermal sensation were measured every 5 minutes during 40 minutes. The four areas of the shoulder, abdomen, hande and feet were heated with the hot pack at $50^{\circ}C$. In the third experiment, the regional thermal resistance of the various materials selected, in two different cases of clothing ease, have been measured by using a thermal manikin. Resultes of experiments were: 1. Extensions cause the upper front part of the trunk surface to lengthen vertically while the back tends to stretch in width. 2. Skin temperatures of the upper limbs are influenced by the abdomen and shoulder boatings. The correlation between the whole body thermal sensation and the upper trunk thermal sensation is significantly asserted. 3. Ceramic and aluminium coated materiales offer the most effective thermal resistance; ease in clothing increases the thermal resistance at the breast and the abdomen as well as the clo value of the materials.

  • PDF

Design for Access Control System based on Voice Recognition for Infectious Disease Prevention (전염성 확산 차단을 위한 음성인식 기반의 출입통제시스템 설계)

  • Mun, Hyung-Jin;Han, Kun-Hee
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.7
    • /
    • pp.19-24
    • /
    • 2020
  • WHO declared a global pandemic on March 11th for Corona 19. However, there is a situation where you have to go to building for face-to-face education or seminars for economic and social activities. The first check method of COVID-19 infection is to measure body temperature, so the primary entrance and exit is blocked for near-field body temperature measurement. However, since it is troublesome to check directly, thermal camera is installed at the entrance of the building, and body temperature is measured indirectly using the infrared camera to control access. In case of middle and high schools, universities, and lifelong education center, we need a system that is possible to interoperate with attendance checks and automatically recognizes whether to wear masks and can authenticate students. We proposed the system that is to confirm whether to wear a mask with a camera that is embedded in a smart mirror, and that authenticates the user through voice recognition of the user who wants to enter the building by using voice recognition technology and determines whether to enter them or not. The proposed system can check attendance if it is linked with near-field temperature measurement and attendance check APP of student's smart phone.

A Study on Acupuncture of Spring-point(형혈); Effect on Body Temperature and Central Immune System (형용자침이 발열 흰쥐의 체온하강과 중추성 면역에 미치는 영향)

  • 박승미;이혜정;신형철;김혜정;임사비나
    • The Journal of Korean Medicine
    • /
    • v.22 no.2
    • /
    • pp.109-119
    • /
    • 2001
  • Objective : There are many reports that acupuncture has thermoregulatory effects on human and animals. To investigate the effect and mechanism of antipyretic action of acupuncture, we observed the body temperature and cytokine expressions in the hypothalamus of rats. Methods : Lipopolysaccharide (LPS, i.p., 2.5mg/kg) was injected to conscious rats (Sprague-Dawley, male, n=4l) to cause hyperthermia and simple needling (stainless steel, 0.25 mm o.d., 5 mm insertion for 10 sec with no manipulation) was performed bilaterally with the measurement of rectal temperature. Next, we sacrificed rats to remove brain and determined the level of mRNA for interleukin-6 (IL-6), $interleukin-1{\beta}{\;}(IL-1{\beta})$, interleukin-2 (IL-2) and $interferon-{\gamma}{\;}(IFN-{\gamma})$ in the hypothalamus by using reverse transcriptase-polymerase chain reaction (RT-PCR). Resul1s : Needling on forepaw (acupoint HT8) and needling on hindpaw (acupoint BL66 and acupoint LR2) significantly inhibited LPS-induced fever of rats (P<0.01, 10 min after treatment respectively), but same treatment on proximal tail (non-acupoint) did not cause any change on fever. The levels of IL-6 and $IL-1{\beta}$ mRNA in the hypothalamus was significantly enhanced by LPS-injection, while the level of IL-6 and $IL-1{\beta}$ mRNA was markedly reduced after treatment on BL66 (P<0.01). Treatment on forepaw reduced it slightly, but not significantly. Equivalent stimulation on proximal tail did not cause any changes. Conclusions : Our results indicate that acupuncture stimulation on various body parts has differential thermoregulatory effects on LPS-induced fever of rats with site-specificity. And, we suggest that its antipyretic action might be accompanied with the suppression of hypothalamic production of pro-inflammatory cytokine of immune system, IL-6 and $IL-1{\beta}$.

  • PDF

Performance Improvement of a Scroll Compressor by Heat Transfer Analysis (열전달 해석을 통한 스크롤 압축기 성능 개선)

  • Hong, S. W.;Rew, H. S.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.3 no.4 s.9
    • /
    • pp.22-29
    • /
    • 2000
  • Numerical analysis using three dimensional finite volume method for the discretization, adaptive grid method for the numerical accuracy, multiple rotating frame method for the rotating body and the standard $k-{\epsilon}$ model for the turbulent flow was performed to understand the heat transfer phenomena and to improve the efficiency of the scroll compressor. The temperature measurement was carried out under ARI condition. It was found that the fluid temperature in the compressor was predicted accurately while the temperature of the motor coil showed large discrepancy between the calculation and experiment due to the large anisotropy of the conductivity and non homogeneity. We found that the efficiency of the compressor depends on the inlet temperature of the compressing part and the flow pattern around the inlet region of the compressing part influences the inlet temperature due to high surface temperature of the main frame. The efficiency of the compressor using Coanda effect is higher than the previous one because the smooth suction at the inlet region of the compressing part leads to low heat transfer to the refrigerant of the compressor.

  • PDF