• Title/Summary/Keyword: Body temperature measurement

Search Result 223, Processing Time 0.028 seconds

A STUDY ON THE TEMPERATURE CHANGES OF BONE TISSUES DURING IMPLANT SITE PREPARATION (임플랜트 식립부위 형성시 골조직의 온도변화에 관한 연구)

  • Kim Pyung-Il;Kim Yung-Soo;Jang Kyung-Soo;Kim Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.1
    • /
    • pp.1-17
    • /
    • 2002
  • The purpose of this study is to examine the possibility of thermal injury to bone tissues during an implant site preparation under the same condition as a typical clinical practice of $Br{\aa}nemark$ implant system. All the burs for $Br{\aa}nemark$ implant system were studied except the round bur The experiments involved 880 drilling cases : 50 cases for each of the 5 steps of NP, 5 steps of RP, and 7 steps of WP, all including srew tap, and 30 cases of 2mm twist drill. For precision drilling, a precision handpiece restraining system was developed (Eungyong Machinery Co., Korea). The system kept the drill parallel to the drilling path and allowed horizontal adjustment of the drill with as little as $1{\mu}m$ increment. The thermocouple insertion hole. that is 0.9mm in diameter and 8mm in depth, was prepared 0.2mm away from the tapping bur the last drilling step. The temperatures due to countersink, pilot drill, and other drills were measured at the surface of the bone, at the depths of 4mm and 8mm respectively. Countersink drilling temperature was measured by attaching the tip of a thermocouple at the rim of the countersink. To assure temperature measurement at the desired depths, 'bent-thermocouples' with their tips of 4 and 8mm bent at $120^{\circ}$ were used. The profiles of temperature variation were recorded continuously at one second interval using a thermometer with memory function (Fluke Co. U.S.A.) and 0.7mm thermocouples (Omega Co., U.S.A.). To simulate typical clinical conditions, 35mm square samples of bovine scapular bone were utilized. The samples were approximately 20mm thick with the cortical thickness on the drilling side ranging from 1 to 2mm. A sample was placed in a container of saline solution so that its lower half is submerged into the solution and the upper half exposed to the room air, which averaged $24.9^{\circ}C$. The temperature of the saline solution was maintained at $36.5^{\circ}C$ using an electric heater (J. O Tech Co., Korea). This experimental condition was similar to that of a patient s opened mouth. The study revealed that a 2mm twist drill required greatest attention. As a guide drill, a twist drill is required to bore through a 'virgin bone,' rather than merely enlarging an already drilled hole as is the case with other drills. This typically generates greater amount of heat. Furthermore, one tends to apply a greater pressure to overcome drilling difficulty, thus producing even greater amount heat. 150 experiments were conducted for 2mm twist drill. For 140 cases, drill pressure of 750g was sufficient, and 10 cases required additional 500 or 100g of drilling pressure. In case of the former. 3 of the 140 cases produced the temperature greater than $47^{\circ}C$, the threshold temperature of degeneration of bone tissue (1983. Eriksson et al.) which is also the reference temperature in this study. In each of the 10 cases requiring extra pressure, the temperature exceeded the reference temperature. More significantly, a surge of heat was observed in each of these cases This observations led to addtional 20 drilling experiments on dense bones. For 10 of these cases, the pressure of 1,250g was applied. For the other 10, 1.750g were applied. In each of these cases, it was also observed that the temperature rose abruptly far above the thresh old temperature of $47^{\circ}C$, sometimes even to 70 or $80^{\circ}C$. It was also observed that the increased drilling pressure influenced the shortening of drilling time more than the rise of drilling temperature. This suggests the desirability of clinically reconsidering application of extra pressures to prevent possible injury to bone tissues. An analysis of these two extra pressure groups of 1,250g and 1,750g revealed that the t-statistics for reduced amount of drilling time due to extra pressure and increased peak temperature due to the same were 10.80 and 2.08 respectively suggesting that drilling time was more influenced than temperature. All the subsequent drillings after the drilling with a 2mm twist drill did not produce excessive heat, i.e. the heat generation is at the same or below the body temperature level. Some of screw tap, pilot, and countersink showed negative correlation coefficients between the generated heat and the drilling time. indicating the more the drilling time, the lower the temperature. The study also revealed that the drilling time was increased as a function of frequency of the use of the drill. Under the drilling pressure of 750g, it was revealed that the drilling time for an old twist drill that has already drilled 40 times was 4.5 times longer than a new drill The measurement was taken for the first 10 drillings of a new drill and 10 drillings of an old drill that has already been used for 40 drillings. 'Test Statistics' of small samples t-test was 3.49, confirming that the used twist drills require longer drilling time than new ones. On the other hand, it was revealed that there was no significant difference in drilling temperature between the new drill and the old twist drill. Finally, the following conclusions were reached from this study : 1 Used drilling bur causes almost no change in drilling temperature but increase in drilling time through 50 drillings under the manufacturer-recommended cooling conditions and the drilling pressure of 750g. 2. The heat that is generated through drilling mattered only in the case of 2mm twist drills, the first drill to be used in bone drilling process for all the other drills there is no significant problem. 3. If the drilling pressure is increased when a 2mm twist drill reaches a dense bone, the temperature rises abruptly even under the manufacturer-recommended cooling conditions. 4. Drilling heat was the highest at the final moment of the drilling process.

Study on the Possibility of Quantitative Measurement of Abdominal Examinations in Korean Medicine - A Focus on Diagnosis of Abdominal Coldness in Functional Dyspepsia Patients - (한의 복진 정량화 연구 - 기능성 소화불량 환자의 복냉 진단을 중심으로 -)

  • Lee, Jae-hong;Cho, Soo-ho;Ko, Seok-jae;Kim, Jin-sung;Park, Jae-woo
    • The Journal of Internal Korean Medicine
    • /
    • v.39 no.4
    • /
    • pp.495-510
    • /
    • 2018
  • Objective: This study was designed to investigate the possibility of quantification of the diagnosis of abdominal coldness (AC) in patients with functional dyspepsia (FD). Methods: Forty-four patients with FD were enrolled in this study. Three Korean medicine doctors each randomly examined all abdomens. Diagnosis of AC was made by consensus of at least two of the doctors. Body temperature (oral by digital oral thermometer) and skin temperature (by digital infrared thermal imaging [DITI]) were measured, followed by administration of the Cold and Heat questionnaire (CHQ) and the Instrument of Pattern Identification for Functional Dyspepsia (IPIFD). Results: Of the 44 patients with FD, 22 were assigned to the AC group and 22 to the non-AC group. The concordance rate of diagnosis among the three doctors was 63.6% (28/44), with a ${\kappa}$ of 0.504, indicating means moderate agreement). Neither the oral nor the skin temperatures showed statistically significant differences between the AC and non-AC groups. However, the CHQ scores and 'Simultaneous Occurrence of Cold and Heat Syndromes pattern' scores of the IPIFD were higher in AC group and showed statistically significant differences (p=0.010 and 0.009). Conclusions: This is the first study conducting quantitative measurements of abdominal coldness in patients with FD. Although oral and skin temperature showed no statistical significance between AC and non-AC groups, the concordance rate of diagnosis of AC among the three Korean Medicine doctors was moderate. The CHQ scores and 'Simultaneous Occurrence of Cold and Heat Syndromes pattern' scores of the IPIFD also suggest that diagnosis of AC is relevant to cold and heat patterns, and these questionnaires could be utilized as supportive data for the diagnosis of AC. Further studies should be conducted for the purpose of quantifying and standardizing abdominal examinations in Korean Medicine.

Analysis of the mixing effect of the confluence by the difference in water temperature between the main stream and the tributary (본류와 지류의 수온 차에 의한 합류부 혼합 양상 분석)

  • Ahn, Seol Ha;Lee, Chang Hyun;Kim, Kyung Dong;Kim, Dong Su;Ryu, Si Wan;Kim, Young Do
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.2
    • /
    • pp.103-113
    • /
    • 2023
  • The river confluence is a section in which two rivers with different topographical and hyrodynamic characteristics are combined into one, and it is a section in which rapid flow, inflow of sediments, and hydrological topographic changes occur. In the confluence section, the flow of fluid occurs due to the difference in density due to the type of material or temperature difference, which is called a density flow. It is necessary to accurately measure and observe the confluence section including a certain section of the main stream and tributaries in order to understand the mixing behavior of the water body caused by the density difference. A comprehensive analysis of this water mixture can be obtained by obtaining flow field and flow rate information, but there is a limit to understanding the mixing of water bodies with different physical properties and water quality characteristics of rivers flowing with stratigraphic flow. Therefore, this study attempts to grasp the density flow through the water temperature distribution in the confluence section. Among the extensive data of the river, vertical data and water surface data were acquired, and through this, the stratification phenomenon of the confluence was to be confirmed. It was intended to analyze the mixed pattern of the confluence by analyzing the water mixing pattern according to the water temperature difference using the vertical data obtained by measuring the repair volume by installing the ADCP on the side of the boat and measuring the real-time concentration using YSI. This study can supplement the analysis results of the existing water quality measurement in two dimensions. Based on the comparative analysis, it will be used to investigate the current status of stratified sections in the water layer and identify the mixing characteristics of the downstream section of the river.

Development of control system for complex microbial incubator (복합 미생물 배양기의 제어시스템 개발)

  • Hong-Jik Kim;Won-Bog Lee;Seung-Ho Lee
    • Journal of IKEEE
    • /
    • v.27 no.1
    • /
    • pp.122-126
    • /
    • 2023
  • In this paper, a control system for a complex microbial incubator was proposed. The proposed control system consists of a control unit, a communication unit, a power supply unit, and a control system of the complex microbial incubator. The controller of the complex microbial incubator is designed and manufactured to convert analog signals and digital signals, and control signals of sensors such as displays using LCD panels, water level sensors, temperature sensors, and pH concentration sensors. The water level sensor used is designed and manufactured to enable accurate water level measurement by using the IR laser method with excellent linearity in order to solve the problem that existing water level sensors are difficult to measure due to foreign substances such as bubbles. The temperature sensor is designed and used so that it has high accuracy and no cumulative resistance error by measuring using the thermal resistance principle. The communication unit consists of two LAN ports and one RS-232 port, and is designed and manufactured to transmit signals such as LCD panel, PCT panel, and load cell controller used in the complex microbial incubator to the control unit. The power supply unit is designed and manufactured to supply power by configuring it with three voltage supply terminals such as 24V, 12V and 5V so that the control unit and communication unit can operate smoothly. The control system of the complex microbial incubator uses PLC to control sensor values such as pH concentration sensor, temperature sensor, and water level sensor, and the operation of circulation pump, circulation valve, rotary pump, and inverter load cell used for cultivation. In order to evaluate the performance of the control system of the proposed complex microbial incubator, the result of the experiment conducted by the accredited certification body showed that the range of water level measurement sensitivity was -0.41mm~1.59mm, and the range of change in water temperature was ±0.41℃, which is currently commercially available. It was confirmed that the product operates with better performance than the performance of the products. Therefore, the effectiveness of the control system of the complex microbial incubator proposed in this paper was demonstrated.

A Study of the Thermoluminescent Properties of Korean Natural Quartz for Possible Use in Gamma-ray Dosimetry

  • Lee, Hee-Yong;Kim, Hi-Gyu;Lee, Chul
    • Nuclear Engineering and Technology
    • /
    • v.2 no.4
    • /
    • pp.229-239
    • /
    • 1970
  • Various thermoluminescent properties of Korean natural quartz for possible use in ${\gamma}$-ray dosimetry has been studied. If the heating is exactly linear, ${\gamma}$-irradiated radiation sensitive (type 1) $\alpha$-quartz can yield a glow curve of single peak, hence glow peak height could be taken as a ${\gamma}$-dose for its dosimetry. Quartz crystal dosimeter exhibited the linearity of thermoluminescent intensity in the range from about 2$\times$10$^{3}$R to 2$\times$10$^{6}$ R, and also had an advantage of low fading because of the high peak temperature (300$\pm$4$0^{\circ}C$). The pulverized quartz sample having the grain size of 0.3<ø<0.9mm showed the linearity of T. L. intensity in the range from 50R to 2$\times$10$^3$R. Therapeutic application of the pulverized sample on the correct measurement of the absorbed dose in a body region of a cancer patient seems to be successful.

  • PDF

Development of a Stockbreeding Management System for Dairy Cattle (젖소의 사양관리 시스템 개발)

  • Kim, Dong-Won;Han, Byung-Sung;Chong, Kil-To;Kim, Yong-Jun;Kim, Myoung-Soon;Lim, Tae-Yeong;Chae, Seok
    • IE interfaces
    • /
    • v.11 no.3
    • /
    • pp.193-207
    • /
    • 1998
  • The agriculture and fishery share in the Korean GDP is continuously decreasing after 1960s. Furthermore the proportion of these industries in the GDP has diminished as low as 10 percent in recent years. However, the stockbreeding sector in these industries are considerably expanded. More than 50 percent of the whole farmhouses are involved in the livestock farming, and the stock farming portion is steadily increased in its size and scope. Thus, the mechanization and the automization of stockbreeding equipments are greatly required to reduce down production cost, as well as to win the competitiveness in the global market. From this aspect, developed in this paper is a stockbreeding management system (SMS) for dairy cattle, which can be used in small and medium sized dairy farms. First, the basic schema of the stockbreeding management system are addressed in view of stockbreeding management for individual dairy cattle. Electronic identification (EI) systems and sensory devices have changed stockbreeding management strategy from group stock control into individual stock control manner. The SMS receives stock body measurement data through the sensory devices such as weight, temperature, and milk conductivity meters. A common database then integrates those measuring data together so that the SMS can determine the appropriate solution on each stock's breeding such as feeding and milking. Thus, each stock can be supervised by a sophisticated SMS that provides the best solution to the stockbreeding throughout the stock's whole life-cycle. Secondly. six major submodules of the SMS, based on the EI and sensory devices, are proposed. They are individual stock management, disease management, health management, feeding management, milking management, and a propagation management submodule. Finally, a prototype system for the SMS is demonstrated. The system is developed using Delphi 2 client-server system run under the Windows 95 environment.

  • PDF

A Study of the Neonatal Care in the hospitals located in Pusan (부산광역시 소재 병원의 신생아간호 실태조사)

  • Kim, Young-Hae;Lee, Hwa-Za;Kim, Soon-Goo
    • Korean Parent-Child Health Journal
    • /
    • v.6 no.1
    • /
    • pp.31-45
    • /
    • 2003
  • This study is designed to produce basic data on the nursing intervention between infants and mothers after discharge from hospitals. This research is carried by investigating the nursing intervention during their after-delivery staying in the hospitals located in Pusan. The object of this study includes the neonatal wards of 51 hospitals. Data collection was carried from the 3rd of September, 2001 to the 4th of October in the same year. Tools for measurement using in this research is the nursing checklist designed by these researchers. The data were analyzed by using SPSS and the output was produced in frequency and percentage considering general characteristics and nursing activities. On the course of investigation, it was revealed that the average number of items checked are as follows; total beds in one hospital came up to 360.1, the beds in each newborn infant ward came up to 36.1, in each ward the numbers of incubators came up to 9.2 and intensive care unit to 1.7. In each ward 8.4 nurses and 2.9 nurse aids were working at that time. In each hospital, secure of air way, physical examination, eye care, umbilical cord care, maintenance of body temperature, identification of infant, nutritive condition, safety and danger management, infection management, mother-infantile interaction, medical assistant to doctor, medication and discharge education were comparatively well done. But, in case of emotional, social and cognitive aspect of nursing activities through interactions between newborn infants and nurses as substitutes are not reached to the adequate level. In the end, this study hereby suggests that further investigation on the device to facilitate the interaction between newborn infant and nurse as a nursing intervention of high quality.

  • PDF

Characteristics of Bovine Teeth Whitening in Accordance with Gas Environments of Atmospheric Pressure Nonthermal Plasma Jet

  • Sim, Geon Bo;Kim, Yong Hee;Kwon, Jae Sung;Park, Daehoon;Hong, Seok Jun;Kim, Young Seok;Lee, Jae Lyun;Lee, Gwang Jin;Lim, Hwan Uk;Kim, Kyung Nam;Jung, Gye Dong;Choi, Eun Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.250.2-250.2
    • /
    • 2014
  • Currently, teeth whitening method which is applicable to dental surgery is that physician expertises give medical treatment to teeth directly dealed with a high concentration of hydrogen peroxide and carbamide peroxide. If hydrogen peroxide concentration is too high for treatment of maximized teeth whitening effect [1], it is harmful to the human body [2]. To the maximum effective and no harmful teeth whitening effect in a short period of time at home, we have observed the whitening effect using carbamide peroxide (15%) and a low-temperature atmospheric pressure plasma jet which is regulated by the Food and Drug Administration. The gas supplied conditions of the non-thermal atmospheric pressure plasma jet was with the humidified (0.6%) gas in nitrogen or air at gas flow rate of 1000 sccm. Also, the measurement of chemical species from the jet was carried out using the optical emission spectroscopy (OES), the evidence of increased reactive oxygen species compared to non-humidified plasma jet. We have found that the whitening effect of the plasma is very excellent through this experiment, when bovine teeth are treated in carbamide peroxide (15%) and water vapor (0.2 to 1%). The brightness of whitening teeth was increased up to 2 times longer in the CIE chromaticity coordinates. The colorimetric spectrometer (CM-3500d) can measure color degree of whitening effect.

  • PDF

LED Fiber-Optic Lighting Devices Developed for Medical Assistance for the Local Treatment Retractor (국부치료를 위한 Retractor용 LED 광섬유 의료보조조명 장치 개발)

  • Eo, Ik-soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.2
    • /
    • pp.666-671
    • /
    • 2016
  • This paper introduces a device providing close local lighting to the affected part, where the operation-purpose astral lamp alone cannot shed light directly, in an operation room of hospitals or clinics, which helps clinical doctors perform safe treatment of the affected part deep inside a human body. This medical assisting lighting is a device necessary to prevent fatal operation failures, which can occur with minute operation processes, such as tumor removal or angiorrhaphy. The components, such as the light source and power supply were designed to be low power consuming and small in size, have a narrow angle lens was used to increase the light spreading effect and focused illumination. The end-caps of the light transmission device using an optical cable and the lighting device were designed in the waterproof type to enable disinfection of these devices after use for the next patients. According to the measurement of the light source properties made after development of the retractor lighting device, the illumination intensity was 490 lux, the brightness was $11,550cd/m^2$, general color rendering index was 78, color temperature was 11,000K, and the intensity distribution was even, which were confirmed to be adequate for medical assisting local lighting.

A study of semi-quantification of the Friedel's salt using the X-ray diffraction method in concrete (콘크리트 내 Friedel염의 XRD를 이용한 반정량적 측정기법에 관한 연구)

  • Lee, Ho-Jae;Lee, Jang-Hwa;Kim, Do-Gyeum
    • Analytical Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.33-38
    • /
    • 2012
  • Despite the importance of chloride binding, it is very difficult to measure the binding capacity, in particular, for the concrete body in an existing structure: in fact, the measurement procedure for chloride binding is much influenced by the environmental condition such as temperature, fineness of sample and pore water extraction techniques. The present study concerns the quantification of the binding capacity of chloride ions in concrete using the X-ray diffraction (XRD) technique. Once the binding isotherm of chlorides was determined by the Langmuir isotherm, as a function of the W/C, curing age and binder type, the generation of bound chlorides (i.e. Friedel's salt) was simultaneously ensured by the XRD technique. The amount of bound chloride was then determined by analyzing the peak intensity for the bound chlorides in the XRD curve. It was found that an increase in the curing age and a decrease in the W/C resulted in an increase in the binding capacity.