• Title/Summary/Keyword: Body temperature measurement

Search Result 223, Processing Time 0.029 seconds

A Study on the Measurement of Respiratory Rate Using Image Alignment and Statistical Pattern Classification (영상 정합 및 통계학적 패턴 분류를 이용한 호흡률 측정에 관한 연구)

  • Moon, Sujin;Lee, Eui Chul
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.8 no.10
    • /
    • pp.63-70
    • /
    • 2018
  • Biomedical signal measurement technology using images has been developed, and researches on respiration signal measurement technology for maintaining life have been continuously carried out. The existing technology measured respiratory signals through a thermal imaging camera that measures heat emitted from a person's body. In addition, research was conducted to measure respiration rate by analyzing human chest movement in real time. However, the image processing using the infrared thermal image may be difficult to detect the respiratory organ due to the external environmental factors (temperature change, noise, etc.), and thus the accuracy of the measurement of the respiration rate is low.In this study, the images were acquired using visible light and infrared thermal camera to enhance the area of the respiratory tract. Then, based on the two images, features of the respiratory tract region are extracted through processes such as face recognition and image matching. The pattern of the respiratory signal is classified through the k-nearest neighbor classifier, which is one of the statistical classification methods. The respiration rate was calculated according to the characteristics of the classified patterns and the possibility of breathing rate measurement was verified by analyzing the measured respiration rate with the actual respiration rate.

Approach-avoidance, Stress Response, and Body Temperature of Dogs Following Removal of the Mamillary Bodies (유두체를 떼어버린 개의 접근-회피반응, 스트레스에 대한 반응 및 체온 변동)

  • Kim, Chul;Park, Rho-Soon
    • The Korean Journal of Physiology
    • /
    • v.2 no.1
    • /
    • pp.1-8
    • /
    • 1968
  • As a continuation of a series of work on the physiology of the mamillary bodies, 3 experiments were carried out using 8 pointer dogs subjected surgical removal of this hypothalamic structure by subtemporal approach. In the first experiment, animals were tested per- and postoperatively in approach-avoidance situation. Food served as incentive, electric shock to the tongue as punishment, and response latency of postpunishment trial as an index of fear. The second experiment dealt with per- and postoperative tests in stress situation. A high frequency sound (12,000 cycle, 100 db sound for 1 hour) was regarded as a stressor, and decrease in blood eosinophil cell count as an index of response th the stress. Pre- and postoperative measurement of rectal temperature was carried out in the third experiment, using a clinical thermometer with decimal centigrade scale. The results obtained were as follows: 1. Tests in approach-avoidance situation showed no indication of increased or decreased fear response following removal of the mamillary bodies. 2. Postoperative stress response was as marked as that of preoperative period, but the recovery from the stress was significantly retarded after surgery. 3. The body temperature dropped slightly, but significantly following damage to the mamillary bodies.

  • PDF

Study on the Behavior of the Fish - 1 . The Swimming Force of Crusian Carp , Carassius Carassius - (어류의 행동에 관한 연구 - 1 . 붕어의 유영력 -)

  • 손태준
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.20 no.1
    • /
    • pp.1-5
    • /
    • 1984
  • The author carried out an experiment for the dynamical swimming force of crusian carp, Carassius carassius. The experimental water tank was made of 4mm thick transparent acryl board in the right hexahedral shape (400L$\times$240W$\times$800H mm). The water temperature in the tank ranged 20.6$^{\circ}C$ to 21.2$^{\circ}C$. The water level in the tank was maintained 70cm high from the bottom. The measurement of the swimming force was carried out by use of strain gauge. The results obtained can be summarized as follows: 1) The momentary maximum swimming force F sub(M) (g) and the sustainable maximum swimming force F sub(s) (g) can be expressed as a function of the body weight W(g). F sub(M) =1.45W, F sub(s) =0.29W where the momentary maximum swimming force means the highest value, and the sustainable maximum swimming force means the mean high value sustained for 4 to 5 seconds presented in the recording paper. 2) F sub(M) and F sub(s) can be expressed as a function of the body length L(cm). F sub(M) =0.11L super(2.63), F sub(s) =0.15L super(1.77) 3) The coefficient of hydraulic resistance for crusian carp was derived as 0.287.

  • PDF

Driver Drowsiness Detection System using Image Recognition and Bio-signals (영상 인식 및 생체 신호를 이용한 운전자 졸음 감지 시스템)

  • Lee, Min-Hye;Shin, Seong-Yoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.6
    • /
    • pp.859-864
    • /
    • 2022
  • Drowsy driving, one of the biggest causes of traffic accidents every year, is accompanied by various factors. As a general method to check whether or not there is drowsiness, a method of identifying a driver's expression and driving pattern, and a method of analyzing bio-signals are being studied. This paper proposes a driver fatigue detection system using deep learning technology and bio-signal measurement technology. As the first step in the proposed method, deep learning is used to detect the driver's eye shape, yawning presence, and body movement to detect drowsiness. In the second stage, it was designed to increase the accuracy of the system by identifying the driver's fatigue state using the pulse wave signal and body temperature. As a result of the experiment, it was possible to reliably determine the driver's drowsiness and fatigue in real-time images.

Measurement of Qi Induced by the Needle Insertion on LI4, LI11 Accupoint using the Oriental Medicine Instruments (인체(人體)의 합곡(合谷) 곡지(曲池) 침자(鍼刺)에 관한 한방진단기기적(韓方診斷機器的) 접근(接近))

  • Jang, K.S.;Na, C.S.;So, C.H.
    • Korean Journal of Oriental Medicine
    • /
    • v.1 no.1
    • /
    • pp.159-178
    • /
    • 1995
  • After acupuncture needles were inserted on apkok(LI4) and Kokchi(LI11) accupoints, physiological changes induced by the varitions of 'Qi' were measured. The body temperature and pulse frequency were fromed to be decreased observed and we presumed that the needle insertion induced some changes of Qi in meridian and this seemed to be achieved by a certain process of Qi induction. We applied EAV, nervinemeter and pulse-taking machine which is widely used as oriental medicine instruments, to the same vounteers and observed the significant variations for each apparatus in spite of partial lack of reproducibility. In this paper, we described about the physical quantity measured by the medical appartatus and how it was related to the variation of Qi The proper conditions used for good oriental medicine instruments have also been suggested.

  • PDF

Serum neuron specific enolase is increased in pediatric acute encephalitis syndrome

  • Pratamastuti, Dian;Gunawan, Prastiya Indra;Saharso, Darto
    • Clinical and Experimental Pediatrics
    • /
    • v.60 no.9
    • /
    • pp.302-306
    • /
    • 2017
  • Purpose: This study aimed to investigate whether serum neuron-specific enolase (NSE) was expressed in acute encephalitis syndrome (AES) that causes neuronal damage in children. Methods: This prospective observational study was conducted in the pediatric neurology ward of Soetomo Hospital. Cases of AES with ages ranging from 1 month to 12 years were included. Cases that were categorized as simple and complex febrile seizures constituted the non-AES group. Blood was collected for the measurement of NSE within 24 hours of hemodynamic stabilization. The median NSE values of both groups were compared by using the Mann-Whitney U test. All statistical analyses were performed with SPSS version 12 for Windows. Results: In the study period, 30 patients were enrolled. Glasgow Coma Scale mostly decreased in the AES group by about 40% in the level ${\leq}8$. All patients in the AES group suffered from status epilepticus and 46.67% of them had body temperature >$40^{\circ}C$. Most of the cases in the AES group had longer duration of stay in the hospital. The median serum NSE level in the AES group was 157.86 ng/mL, and this value was significantly higher than that of the non-AES group (10.96 ng/mL; P<0.05). Conclusion: AES cases showed higher levels of serum NSE. These results indicate that serum NSE is a good indicator of neuronal brain injury.

Physical Properties of High-Solid Coatings with Acrylic Resins Containing Acetoacetoxy Group and HDI-Trimer (Acetoacetoxy기 함유 아크릴수지와 HDI-Trimer에 의한 하이솔리드 도료의 도막물성)

  • You, Hyuk-Jae;Chung, Dong-Jin;Hahm, Hyun-Sik;Park, Hong-Soo;Kim, Seong-Kil
    • Journal of the Korean Applied Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.237-242
    • /
    • 2003
  • The high-solid coatings were prepared by blending the synthesized acrylic resin in the previous paper and hexamethylene diisocyanate-trimer and curing it at room temperature. The characterization of the films of the prepared coatings was performed. The impact resistance, $60^{\circ}C$ specular gloss, cross-hatch adhension, and heat resistance of the films proved to be good, and the pencil hardness and drying time proved to be slightly poor. Especially, there was a remarkable improvement in the heat resistance. This improvement may stem from the regular arrangement of ethyl groups introduced into the acrylic resin. From a viscoelastic measurement using a rigid-body pendulum, curing was accelerated with the $T_g$ value. With the increase in $T_g$, log damp value was lowered and dynamic viscoelasic $T_g$ of a cured film was increased.

Physical Properties of High-Solid Coatings with 80% Solid Contents Acrylic Resins Containing Caprolactone Group and HMDI-Trimer (카프로락톤기 함유 80% 고형분인 아크릴수지와 HMDI-Trimer에 의한 하이솔리드 도료의 도막물성)

  • Park, Hong-Soo;Jung, Choong-Ho;Jo, Hye-Jin;Shim, Il-Woo;Kim, Seung-Jin;Kim, Seong-Kil
    • Journal of the Korean Applied Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.110-114
    • /
    • 2006
  • The high-solid coatings were prepared by blending the synthesized acrylic resin in the previous paper, and hexamethylene diisocyanate-trimer and curing it at room temperature. The characterization of the films of the prepared coatings was performed. The $60^{\circ}$ specular gloss, impact resistance, cross-hatch adhesion, and heat resistance of the films proved to be good, and the pencil hardness, drying time, and pot-life proved to be slightly poor. From a viscoelastic measurement using a rigid-body pendulum, curing was accelerated with the Tg value.

Compaction and Sintering Behavior of $Al_2O_3$-modified Ziroconium Titanate $(ZrTiO_4)$

  • Chun, Myoung-Pyo;Geun, Hur;Myoung, Seung-Jae;Cho, Jung-Ho;Kim, Byung-Ik
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.822-823
    • /
    • 2006
  • The compaction and sintering behavior of zirconium titanate $(ZrTiO_4)$ was investigated by means of the measurement of sintering density and shrinkage, and the observation of microstructure. With increasing the content of $Al_2O_3$ additive, $Al_2O_3$-modified zirconium titanate samples fired at $1300^{\circ}C$ showed the anisotropic shrinkage behavior that the upper region of sintered body has higher sintering shrinkage than the low region. This difference of sintering shrinkage decreased with increasing firing temperature from 1300 to $1400^{\circ}C$. The SEM micrographs of powder compation show that the anisotropic shrinkage behavior is related with non-uniform density in a uniaxial compaction.

  • PDF

Physical Properties of High-Solid Coatings with Acrylic Resins Containing Caprolactone Group and HDI-Trimer (Caprolactone기 함유 아크릴수지와 HDI-Trimer에 의한 하이솔리드 도료의 도막물성)

  • Jo, Hye-Jin;Shim, Il-Woo;You, Hyuk-Jae;Wu, Jong-Pyo;Kim, Myung-Soo;Hahm, Hyun-Sik;Park, Hong-Soo;Baik, Woon-Phil
    • Journal of the Korean Applied Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.300-305
    • /
    • 2004
  • High-solid coatings were prepared by blending of previosly synthesized acrylic resins and hexamethylene diisocyanate-trimer and curing it at room temperature. The characterization of the films of the prepared coatings was performed. The impact resistance, cross-hatch adhesion, $60^{\circ}$specular gloss, and heat resistance of the films proved to be good, and the pencil hardness and drying time proved to be slightly poor. Especially, there was a remarkable improvement in the heat resistance. This improvement may stem from the regular arrangement of ethyl groups introduced into the acrylic resin. As a result of Rigid-body pendulum visco-elasticity measurement, dynamic $T_g$ values of cured films increased with dynamic $T_g$ values.