• Title/Summary/Keyword: Body sensation

Search Result 359, Processing Time 0.026 seconds

Product Characteristics Assessment and Wearing Evaluation of Waist-protection Corset Design (허리보호 코르셋 디자인을 위한 제품 분석 및 착용 평가)

  • Kim, Soyoung;Lee, Heeran
    • Fashion & Textile Research Journal
    • /
    • v.23 no.6
    • /
    • pp.781-789
    • /
    • 2021
  • To enhance the design and comfort of waist-protection corsets, this study analyzed the product characteristics of five types of posture-correction corsets that are available commercially. Additionally, subjective evaluation of the corsets was conducted on women aged 20 to 60 years, in terms of design, material preference, fit, comfort, degree of correction, freedom of movement, tightness, and convenience of front fastening. Following product analysis, the five corset types were divided into: two soft, one semi-hard, and two hard types in terms of the degree of elongation. As a result of pattern analysis, the soft type was designed to improve fit by reflecting the body curvature, whereas the semi-hard and hard types were relatively flat. Through the wearing sensation assessment, the hard type manufactured by company S was the best in terms of design, material, fit, comfort, correction degree, and freedom of movement. The soft type was average in design, material, and fit while relatively poor in the correction degree and tightness. The results indicated that soft materials, flexible bones with appropriate tension, patterns designed to snugly fit the body with large curvature at the top and bottom for better inflection, and adjustable support belts that can be double-fixed are crucial elements in improving the corset design to boost the comfort of wearing. These study results are helpful in the development of waist-protection corsets with excellent wearing comfort and design appreciated by customers.

Assessment of Wear Comfort and the Development of One-piece Dresses with Persimmon Juice Dye-printed Fabrics (감즙염색 날염 소재 원피스 개발과 인체착용실험에 의한 생리반응 및 착용감 평가)

  • Park, Soon Ja;Kang, Inhyeng
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.38 no.1
    • /
    • pp.73-86
    • /
    • 2014
  • Persimmon juice dye-printed fabrics with printing were used for a Galot one-piece dress. The Galot dress was assessed in comparison to a white undyed one-piece dress of the same design through a wearing test conducted in a climatic chamber with an air temperature of $30{\pm}1^{\circ}C$, $50{\pm}5%$ R.H, and 0.2m/sec air movement on 4 healthy female subjects in their 20s. The subjects went through a 30-min stable period, a 30-min exercise of walking on a $5^{\circ}$ slope treadmill at 70m/min period, and a 20-min recovery period. In addition, a physiological reaction and subjective sensation were estimated. The results showed that significant differences were mostly observed from a sweating period that occurred during the latter half of the exercise. More specific results are as follows. First, skin temperature on the chest and mean skin temperature were significantly higher (p<.01) in rayon dyed sample dresses. Second, micro-humidity on the back showed a significant difference (p<.01). Both cotton and rayon persimmon juice dyed sample dresses produced lower microhumidity than their counterparts and as for cotton the difference occurred over the entire experimental period; however, it occurred after the middle of the exercise period for rayon. Third, the sweating rate on the back decreased in both cotton and rayon with persimmon juice dye but no significant difference was observed. Fourth, subjective three sensations revealed significant differences between cotton and rayon (p<.01), indicating that the subjects felt more cool, dryer and more comfortable in a cotton Galot. As described above, the analysis of physiological responses and the subjective sensation of undyed and dyed clothing shows the effect of persimmon juice dyeing. Persimmon juice dyeing also seemly increased air permeability, moisture regain and permeability facilitating body heat ventilation, as micro-humidity and sweat rate were lowered. However, this was not shown consistently in subjective responses on comfort especially when wearing rayon dresses.

A Study on The Excessive Liver-Symptoms(肝實證) in The Analysis of Five Visceral Symptoms By The Five Pathogenic Factors(五邪) (오장변증중(五臟辨證中) 간실증(肝實證)의 오사(五邪)에 의한 연구)

  • Kim, Jae-Hong;Kim, Tae-Hee
    • The Journal of Internal Korean Medicine
    • /
    • v.15 no.1
    • /
    • pp.176-209
    • /
    • 1994
  • 1. The Jung-Sa(正邪) of the Excessive Liver-Symptoms belongs to the eleven symptoms, there are blue face, blue thin fingernail, anger, fancy of larg body, dizziness, eye flame, Bell's palsy, hard swelling pain at braest, side pain going on the belly from the side, side pain and movement at the left side. 2. The Mi-Sa(微邪) of the Excessive Liver-Symptoms belongs to the four symptoms, there are meat in eye, edema in cheek, lack of appetite and diarrhea. 3. The Juk-Sa(賊邪) of the Excessive Liver-Symptoms belongs to the only one symptom, this is nosebleeding. 4. The Hu-Sa(虛邪) of the Excessive Liver-Symptoms belongs to the three symptoms, there are scrotum constraction, strain in belly and constipation. 5. The Sil-Sa(實邪) of the Excessive Liver-Symptoms belongs to the twenty eight symptoms, there are red eye, raised eyes(兩眼上?), spitting blood, sternocostal turgid pain, turgidity in belly, drooping testis, vomiting water acid, sickening, belching, confusion, impatience, frequent forgetfulness, headache, giddness, eye pain, deaf, ringing in the ear, feeling inverse, drying mouth, stuffiness sensation in the chest, chest pain, stuffiness sensation in the belly, bellyache, quadriplegia, spasm of extremities, tremor, alternate spells of fever and chills, high fever and strain in muscle. 6. Those symptoms, Red corner of the eye, red face, swelling on the forehead, stiff-neck and back strong, opisthotonos, constracture of the limbs, vomiting yellow bitter water, speech impediment, epilepsy, depression, strong tongue, different thing in throat, fullness and distention of the gastric region, feeling sick and tenesmus, have no connected with the Excessive Liver-Symptoms(肝實證) 7. The Excessive Liver-Symptoms(肝實證) is connected with the ganjabyoung(肝自病) and Hwa(火) which the pathology is, than because Mock(木) is excessive and Mock-Saeng-Hwa(木生火), the ganjabyoung(肝自病) and Sil-Sa(實邪) are many. 8. There are the sixteen symptoms with the exception of The Excessive Liver-Symptoms(肝實證), because supposed that the scholars in medicine included the union syndroms(合病), the combine syndroms(兼病) and the analysis of symptoms(辨證) in The Analysis of Five Visceral Symptoms. 9. During consideration of the symptoms at the above statements, where are many causes by Gan-Pung(肝風), there is difficult of distinction between the excessive Liver-Symptoms(肝實證) and C.V.A(Cerebral Vascular Attack). Because than NaeKyung(內經) distinguished between the excessive Liver-Symptoms(肝實證) and C.V.A., the future medical specialists connected with the excessive Liver-Symptoms(肝實證) and C.V.A.. 10. An appearance of Sang-Hwa(相火) that the liver possessed is divided into an appearance of Hwa(火), there will be making a study att the more necessary. 11. The cuases of each syndroms are consist of the origins of syndroms, its pathology and the positions where the syndroms appeared, I consider that is the various ways how judge the syndroms except the Five Pathogenic Factors(五邪). 12. If more than study will be achieved in all, the new definition will be standed about the Excessive and Deficient Five Visceral Syndroms(五臟虛實證), I consider this will be the foundation data that study the Oriental Medicine and the important data that is a judgement standard of clininc.

  • PDF

Painful Channels in Sensory Neurons

  • Lee, Yunjong;Lee, Chang-Hun;Oh, Uhtaek
    • Molecules and Cells
    • /
    • v.20 no.3
    • /
    • pp.315-324
    • /
    • 2005
  • Pain is an unpleasant sensation experienced when tissues are damaged. Thus, pain sensation in some way protects body from imminent threat or injury. Peripheral sensory nerves innervated to peripheral tissues initially respond to multiple forms of noxious or strong stimuli, such as heat, mechanical and chemical stimuli. In response to these stimuli, electrical signals for conducting the nociceptive neural signals through axons are generated. These action potentials are then conveyed to specific areas in the spinal cord and in the brain. Sensory afferent fibers are heterogeneous in many aspects. For example, sensory nerves are classified as $A{\alpha}$, $-{\beta}$, $-{\delta}$ and C-fibers according to their diameter and degree of myelination. It is widely accepted that small sensory fibers tend to respond to vigorous or noxious stimuli and related to nociception. Thus these fibers are specifically called nociceptors. Most of nociceptors respond to noxious mechanical stimuli and heat. In addition, these sensory fibers also respond to chemical stimuli [Davis et al. (1993)] such as capsaicin. Thus, nociceptors are considered polymodal. Recent advance in research on ion channels in sensory neurons reveals molecular mechanisms underlying how various types of stimuli can be transduced to neural signals transmitted to the brain for pain perception. In particular, electrophysiological studies on ion channels characterize biophysical properties of ion channels in sensory neurons. Furthermore, molecular biology leads to identification of genetic structures as well as molecular properties of ion channels in sensory neurons. These ion channels are expressed in axon terminals as well as in cell soma. When these channels are activated, inward currents or outward currents are generated, which will lead to depolarization or hyperpolarization of the membrane causing increased or decreased excitability of sensory neurons. In order to depolarize the membrane of nerve terminals, either inward currents should be generated or outward currents should be inhibited. So far, many cationic channels that are responsible for the excitation of sensory neurons are introduced recently. Activation of these channels in sensory neurons is evidently critical to the generation of nociceptive signals. The main channels responsible for inward membrane currents in nociceptors are voltage-activated sodium and calcium channels, while outward current is carried mainly by potassium ions. In addition, activation of non-selective cation channels is also responsible for the excitation of sensory neurons. Thus, excitability of neurons can be controlled by regulating expression or by modulating activity of these channels.

A clinical study on patients with Cold Hypersensitivity on hands and feet and their autonomic nervous system function using of Heart Rate Variability(HRV) (수족냉증 환자의 실태 및 HRV(Heart Rate Variability)를 이용한 자율신경계 기능 평가 연구)

  • Kim, Eun-Sook;Hwang, Jae-Ho;Lee, Jin-Moo;Lee, Chang-Hoon;Cho, Jung-Hoon;Jang, Jun-Bock;Lee, Kyung-Sub;Choi, Jae-Ho
    • Journal of Oriental Medical Thermology
    • /
    • v.5 no.1
    • /
    • pp.1-13
    • /
    • 2006
  • Objectives : This study was designed to analyze basic data for cold hypersensitivity patients with a questionnaire and investigate correlation between cold hypersensitivity and Heart Rate Variability(HRV). Methods : 49 patients who complain of cold hypersensitivity on hands and feet in ambulatory care were investigated in Oriental Gynecology, Kyunghee Oriental Medical Center and Women medical center, Kangnam Koreana hospital from May 1, 2006 to October 20, 2006. All patients were asked to answer a questionnaire. After careful I examination to rule out other disease which may affect Digital Infrared Thermal Imaging(DITI) and HRV data, patients were taken thermography for the diagnosis of cold hypersensitivity Based on the result of thermography, the patients were divided into two groups(Objective cold hypersensitivity and Subjective cold hypersensitivity). Then, these two groups were compared using HRV data which was measured in the supine position for 5 minutes. Results: 1. For most patients, cold hypersensitivity first developed during puberty. 2. The parts of the body that felt cold first time were hands and feet. 3. The cold sensation was increased in winter or at bedtime Showing that the sensation can be changed according to the level of coldness. 4. Among women who sufferfrom cold hypersensitivity, very few of them were treated. 5. More than half of cold hypersensitivity patients's family member also had a cold hypersensitivity. 6. The decrease in mean values of LF/HF ratio was observed in objective cold hypersensitivity group than subjective cold hypersensitivity group and the decrease was significant(P=0.014) when examined by Student t-test. Conclusions : It is necessary that the cold hypersensitivity patients should be treated carefully considering the facts mentioned above. And it can be suggested that dysautinomia be related with cold hypersensitivity and be evaluated by HRV.

  • PDF

Validity of a Simulated Practical Performance Test to Evaluate the Mobility and Physiological Burden of COVID-19 Healthcare Workers Wearing Personal Protective Equipment (COVID-19 감염병 대응 의료진용 개인보호복의 동작성 및 생리적 부담 평가를 위해 개발된 모의 작업 프로토콜의 타당도)

  • Kwon, JuYoun;Cho, Ye-Sung;Lee, Beom Hui;Kim, Min-Seo;Jun, Youngmin;Lee, Joo-Young
    • Fashion & Textile Research Journal
    • /
    • v.24 no.5
    • /
    • pp.655-665
    • /
    • 2022
  • This study evaluated the validity of a newly developed mobility protocol examining the comfort functions and requirements of personal protective equipment (PPE) for COVID-19 healthcare workers. Eight males (age: 24.7 ± 3.0 y, height: 173.4 ± 2.3 cm, and body weight 69.9 ± 3.7 kg) participated in the following three PPE conditions: (1) Plastic gown ensemble, (2) Level D ensemble, and (3) Powered air purifying respirator (PAPR) ensemble. The mobility protocol consisted of 10 different tasks in addition to donning and doffing. The 10 tasks were repeated twice at an air temperature of 25oC with 74% RH. The results showed significant differences among the three PPE conditions in mean skin temperature, local skin temperatures (the forehead, thigh, calf, and foot), clothing microclimate (the chest and back), thermal sensation, thermal comfort, and humidity sensation, while there were no significant differences in heart rate or total sweat rate. At rest, the subjects felt less warm and more comfortable in the PAPR than in the Level D condition (P<0.05). However, subjective perceptions in the PAPR and Level D conditions became similar as the tasks progressed and mean skin and leg temperature became greater for the PAPR than the Level D condition (P<0.05). An interview was conducted just after completing the mobility test protocol, and suggestions for improving each PPE item were obtained. To sum up, the mobility test protocol was valid for evaluating the comfort functions of PPE for healthcare workers and obtaining requirements for improving the mobility of each PPE item.

Two Cases of the Calculi which Are Rare in the E.N.T. Field (이비인후과 영역에 희귀한 결석증 2례)

  • 이석용;양오규;이영효;심상열;김재선
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1981.05a
    • /
    • pp.11.2-11
    • /
    • 1981
  • Compared with other medical parts, there are relatively rare cases of the calculi in the Otolaryngologic field. The authors have recently experienced cases of the tonsillolith and huge rhinolith. They were removed successfully under the local anesthesia. Small quantities of calcareous or gritty particles are often found in the center of the caseous plugs filling the crypts of the tonsil in chronic follicular tonsillitis. The patients usually give a history of repeated tonsillitis in the earlier years. The patient may be aware of a constant sensation as of a foreign body in the throat. The breath is often fetid. The tonsillar calculi was found to be the accumulated keratohyalin masses in the crypts. The rhinoliths are rare in nasal cavity. They usualy have a foreign body nucleus of bacteria, blood, pus cells, mucus, crusts, or some foreign material from outside the body. They are largely composed of calcium and magnesium salts, principally carbonate with traces of sodium chloride. The condition is commonly found in adults and in female. They are usualy unilateral and are located, in the majority of instances, in the lower portion of the nasal cavity. The first well documented cases of rhinolithiasis, however, were reported by Bartholin in 1654. Since then over 400 cases have been reported.

  • PDF

The Effect of the Skinny Pants on the Physiological Responses and Subjective Pressure (스키니 진 착용이 인체생리반응과 주관적 압박감에 미치는 영향)

  • Kweon, Soo-Ae
    • Korean Journal of Human Ecology
    • /
    • v.21 no.3
    • /
    • pp.567-576
    • /
    • 2012
  • The purpose of this study was to analyze and determine the relationship between physiological responses including blood flow rate and garment pressure, and the feeling of restrictive tightness associated with the wearing skinny pants as a popular clothing style. Evaluation was based on material type, posture and activity type, and body part location. Five female college students took part in this research. Five kinds of experimental clothes with waist measurements of 66cm were chosen. An analysis of the selected skinny pants demonstrated the degree of the whole looseness was higher in this order: clothing type A>B>D>C, and E with E being knitted cloth. Garment pressure was the highest in the front knee portions and was lowest in the outside thigh region. Garment pressure was highest in this sequence : clothing type C>=D>A>=B>E. In terms of posture and activity types, garment pressure was the highest when research participants were crouching, and was the lowest when standing. The blood flow rate was highest in this order: clothing type E>D>B>A>C. Type C skinny pants impeded blood flow and demonstrated the tightest and most restrictive relationship. Blood flow rate varied depending on the type of movement and was highest in this order: getting up, rowing, kicking, jumping and O-shaped leg posture. The results of subjective pressure evaluation demonstrated that pressure was highest in this order: E>=C>B>A>D. These results suggests the need to improve on the patterns and the material design in the area of the front knees. The degree of the looseness when wearing skinny pants did not always correspond to garment pressure or subjective sensation.

Engineering design process of tight-fit sportswear using 3D information of dermatomes and skin deformation in dynamic posture (동적자세와 피부분절을 이용한 기능성 밀착의복 제작 프로세스)

  • Kim, So-Young;Hong, Kyung-Hi
    • Korean Journal of Human Ecology
    • /
    • v.21 no.3
    • /
    • pp.551-565
    • /
    • 2012
  • The primary goal of this study was to provide a systematic methodology of utilizing 3D technology for tight-fit performance sportswear using information of skin deformation in various posture. Technical tools used in this study are Cyberware whole body scanner, RapidForm2004, 2C-AN 3D pattern development program, and YukaCAD. Analysis of the 3D skin deformation while knee joint was bent from $0^{\circ}$ to $60^{\circ}$ revealed that the length of dermatomes L4 was remained consistent during knee bending. Therefore, L4 was chosen as a major cutting line. To develop a highly ergonomic pattern, replicas of static and dynamic postures were developed and integrated using two methods, one is morphing method (Sqirlz Morph), and the other is AutoCAD. Experimental tight-fit garments called 'Derm-Mov Pattern' was designed using dematomes L4, L2, and inner line under knee and compared with four other patterns. As results, AutoCAD was appropriate as a integrating method of various postures. In wear test, 'Derm-Mov Pattern' was rated high (p < .001), in terms of pressure comfort especially around front crotch area. However, wear sensation was not signipicantly different in other area due to highly extensible property of materials. Pressure distribution was relatively even in these experimental garments.

Effects of Fit Factor and Visual Acuity of Eyeglasses Wearers when Wearing Particulate Filtering Facepiece Respirators (안경착용자 방진마스크 착용 시 밀착계수와 착용시력에 미치는 영향)

  • Eoh, Won Souk;Shin, Chang Sup
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.3
    • /
    • pp.105-115
    • /
    • 2020
  • This study compares the difference of fit factors (FF) and visual acuity according to masks and eyeglasses preferences for 54 participants. We the precautions and behaviors of discomfort when wearing masks of eyewear wearers. Contact lens discomfort and priority action of complaints was investigated Glasses fitting factors is Optical Center Height(OH), Vertex Distance(VD) and Pantoscopic Angle(PA). We measured those factors and expressed by the ratio of standard point and change point. Quantitative fit factor was measured by Portacount Pro+ 8038. Also, we selected to 6 exercises among 8 exercises OSHA QNFT (Quantitative Fit testing) protocol to measure the fit factors. The pass/ fail criterion of FF was set at 100. Visual acuity(VA) test chart is developed by Chunsuk Han was used, Descriptive statistics was performed. Descriptive statistics(SAS ver 9.2), it is used geometric means, Wilcoxon analysis(P=0.05) When wearing the mask preferentially, fit factor(FF) was high according to the step of glasses fitting parameter. on the other hand, when the glasses first choice, the visual acuity(VA) was high. there was no significant difference. In the case of fit factor (FF), mask first choice/ glasses first choice is OH (p=0.671/ p=0.332), VD (p=0.602/ p=0.571) and PA (p=0.549/ p=0.607). Visual acuity (VA), mask first choice/ glasses first choice is OH (p=0.753/ p=0.386), VD (p=0.815/ p=0.557) and PA (p=0.856/ p=0.562). The workers of workplace and office chose glasses but occupational health workers and students chose mask. In case of discomforts, it was suggested to remove the mask and tolerate discomforts. The main discomforts and usual action of lens were dryness, hyperemia, foreign body sensation, ophthalmodynia, decreased vision and glasses wearing. Therefore, it is necessary to develop a mask wearing method education program considering glasses fitting and develop a hybrid model that minimizes inconvenience when wearing glasses and a mask at the same time.