• Title/Summary/Keyword: Body sensation

Search Result 360, Processing Time 0.027 seconds

Segmental Artery Injury Following Percutaneous Vertebroplasty Using Extrapedicular Approach

  • Heo, Dong-Hwa;Cho, Yong-Jun
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.2
    • /
    • pp.131-133
    • /
    • 2011
  • We performed a percutaneous vertebroplasty at the compressed L2 vertebral body of a 73-year-old female using a left-sided unilateral extrapedicular approach. She complained severe radiating pain and a tingling sensation in her left leg two hours after the vertebroplasty. Spinal computed tomographic scan showed a large retroperitoneal hematoma, and a subsequent spinal angiography revealed a left L2 segmental artery injury. Bleeding was successfully controlled by endovascular embolization. Recently, extrapedicular approaches have been attempted, allowing for the avoidance of facet and pedicle injury with only a unilateral approach. With this approach, however, the needle punctures the vertebral body directly. Therefore, this procedure carries the potential risk of a spinal segmental artery.

Thermophysiological Response of Human Body in Wearing Codling Vest (냉각조끼착용에 따른 인체의 온열생리학적 특성)

  • 권오경;김태규
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2000.11a
    • /
    • pp.148-154
    • /
    • 2000
  • To do this study, we produced cooling vest newly. Rectal temperature was ascended approximately from 37.2$^{\circ}C$ to 38.05$^{\circ}C$ in lab, but wearing cooling vest, the temperature was descended 0.2 while wearing developed product compare with existing product. Mean skin temperature which was showed distribution from 32.8∼36.5$^{\circ}C$, it was descended 1.0∼1.1$^{\circ}C$, while wearing cooling vest and comparing with existing product, wearing developed product was lower 0.5$^{\circ}C$, While wearing developed product, it was found that they had lower tendency than exiting product. Specifically in case of temperature within clothing(chest) 0.2∼2.0$^{\circ}C$ in case of humidity within clothing 2∼8% RH. Facts from above we confirmed that clothing microclimate had been improved and space was happened between body and garment in order to control. In subjective sensation, existing product made negative response during experiment period from participants, but developed product was nearing to comfortable area.

  • PDF

Effect of Slit Ventilation System in Sportswear on Physiological Responses (스포츠웨어의 슬릿 벤틸레이션 시스템이 인체 생리반응에 미치는 효과)

  • Yeon, Soo-Min;Kim, Hee-Eun
    • Fashion & Textile Research Journal
    • /
    • v.7 no.1
    • /
    • pp.75-80
    • /
    • 2005
  • The purpose of this study was to investigate the effects of silt ventilation system on physiological responses. We measured rectal temperature, local skin temperature, clothing microclimate, blood pressure, heart rate, energy metabolism, body weight loss and subjective sensation during 70 minute, 50 min exercise period and 20 min rest period. The five women subjects randomly wore sportswear without slit ventilation system(NS sportswear) and sportswear with slit ventilation system(S sportswear) under the environmental condition of $25^{\circ}C$, 50%RH. The results of this study are as follows; Rectal temperature, mean skin temperature, clothing microclimate, blood pressure, heart rate, energy metabolism and body weight loss were significantly lower level in 'S sportswear'. In 'S sportswear', subjects replied less hot, less uncomfortable and less wet. Slit ventilation system can be used for bellow effect which is meaningful device of convection during exercise. We could find out that 'S sportswear' has advantage in physiological function.

3D Pattern Construction and Its Application to Tight-fitting Garments for Comfortable Pressure Sensation

  • Jeong Yeon-Hee;Hong Kyung-Hi;Kim See-Jo
    • Fibers and Polymers
    • /
    • v.7 no.2
    • /
    • pp.195-202
    • /
    • 2006
  • Tight-fitting clothing pattern reflecting the accurate information of the 3D body shape has been one of the challenges for garment industry, however, fitting problems still exist. The objectives of the paper is to develop a 2D pattern which fits tightly to the 3D human scan data for sports suits that need comfort and function for maximum performance. In this study, the user graphic interface application software for the semi-automatic garment pattern generation has been implemented using the triangle simplification scheme together with 2D projections of free-falling of 3D surface polygons keeping the original 3D surface area preservation. A typical application of the developed pattern to the functional body suits is presented and verification of the proposed method is also provided.

Suggested Clinical Reasoning Strategies Using a Mnemonic Device for Patients with Neurological Disorders (연상법을 이용한 신경계 환자의 임상적 추론 전략 제안)

  • Woo, Young-Keun
    • PNF and Movement
    • /
    • v.17 no.1
    • /
    • pp.145-156
    • /
    • 2019
  • Purpose: This study suggests clinical reasoning strategies for therapists with little experience in clinical reasoning for the evaluation and treatment of patients with neurological disorders. Methods: The suggested method was the mnemonic PT STRESS whose initials represent the body structure and functions that can affect the activity limits and the items that can cause problems at the functional level in patients with neurological disorders. Results: PT STRESS stands for pain (P), ability of the trunk (T), sensation (S), tone (T), range of motion (R), emotion and endurance (E), muscular strength (strength), and stability (S). It tests and measures problems in the body structure and functions. Conclusion: This study suggests easy clinical reasoning strategies that can be used by therapists who have insufficient experience in the evaluation or treatment of patients with neurological disorders. However, more factors need to be considered in the future with regard to clinical reasoning of the diverse problems of patients with neurological disorders.

A Comparative Study on the CT Effective Dose by the Position of Patient's Arm (전신 PET/CT 검사에서 환자의 팔 위치에 따른 CT 유효선량의 비교 연구)

  • Seong, Ji-Hye;Park, Soon-Ki;Kim, Jung-Sun;Park, Seung-Yong;Jung, Woo-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.44-49
    • /
    • 2012
  • Purpose: In the whole body PET/CT scan, it is natural to lift the patient's arm for its quality improvement. However, when the lesion is located in head and neck, the arms should be located lower. This study was designed to compare the CT effective dose for each arm position applying Automatic Exposure Control (AEC). Materials and Methods: 45 patients who had $^{18}F$-FDG whole body PET/CT scan were studied with Biograph Truepoint 40 (SIEMENS, GERMANY), Biograph Sensation 16 (SIEMENS, GERMANY), Discovery STe 8 (GE healthcare, USA). The CT effective dose of 15 patients for each equipment was measured and comparatively analyzed in both arm-lifted position and lower-arm position. ImPACT v1.0 program was used as the method of measurement for CT effective dose. For the statistics analysis, Paired t-test which paired with SPSS 18.0 statistic program was applied. Results: In the case of arm-lifted, it was measured as $6.33{\pm}0.93mSv$ for Biograph Sensation 16, $8.01{\pm}1.34mSv$ for Biograph Truepoint 40, and $9.69{\pm}2.32mSv$ for Discovery STe 8. When arms are located lower position, it was measure as $6.97{\pm}0.76mSv$, $8.95{\pm}1.85mSv$, $13.07{\pm}2.87mSv$ for each. CT effective dose according to the arm position was 9.2% for Biograph Truepoint 40, 10.5% for Biograph Sensation 16, and 25.9% for Discovery Ste 8. The statistics analysis showed the meaningful difference ($p$<0.05). Conclusion: For the whole body PET/CT case, CT effective dose applying AEC was decreased the radiation exposure of the patients when the arm was lifted for 15.2% of average value. The patient who has no lesion in head and neck would decrease the artifact occurrence in objective part and lower the CT effective dose. Also, for the patient who had lesion in head and neck, the artifact in objective part can be lower by putting the arms down, the fact that CT effective dose increases should be concerned in its whole body PET/CT scan.

  • PDF

The Relationship between Habitual Patient-Reported Symptoms and Signs in the Soft Contact Lens Wearers (소프트 콘택트렌즈 착용자에서 평상시 나타난 증상에 관한 연구)

  • Lee, Koon-Ja;Buyn, Jang-Won;Mun, Mi-Young;Leem, Hyun-Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.3
    • /
    • pp.19-28
    • /
    • 2008
  • Purpose: To understand symptoms and signs in soft contact lens wearers the authors evaluate the attribution of the tear test to the contact lens related symptoms and signs. Methods: Sixty-two healthy soft contact lens wearers (23.95${\pm}$4.38 years old, 18.60${\pm}$16.92 months of prior lens wear) were participated in this study. 3 kinds of tear test and McMonnies' questionnaire test were performed for the soft contact lens wearers and subjective symptoms and objective signs were graded using CCLRU scales during the study period. Results: In this surveys, we found ocular dryness, redness and tiredness are the most common frequent and severe symptoms in soft contact lens wearers. Frequency of the ocular dryness, redness and tiredness are associated with grittiness, burning sensation and foreign body sensation respectively, and severity of the photophobia, foreign body sensation are associated with unstable vision and grittiness and which are associated with score of McMonnies' Questionnaire. Conjunctival redness and limbal redness are major signs but those are not need to be clinical care and rarely occurred corneal and conjunctival staining which are associated with tear break-up-time statistically. Conclusions: Dryness, redness and tiredness are primary common symptoms in Korean soft contact lens wearers. The frequency of those symptoms are increased with the period of soft contact lens wear and those are associated with other symptoms but have no relationship with signs.

  • PDF

Phenomena and characteristics of the extreme in the late Gothic costume (고딕 후기 복식의 극단적 현상 및 특성 연구)

  • Sung, Kwang-Sook
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.20 no.3
    • /
    • pp.99-113
    • /
    • 2018
  • In this study, the reality of international Gothic style was examined through the representative art of the period, such as paintings, architecture and tapestries. In particular zones of the body were examined by applying Harold Koda's methods of discussing extreme beauty to study the phenomena and characteristics of extremes in late Gothic costumes. This arrived at the following conclusions concerning the phenomena and characteristics of the extreme appearing in the late Gothic costumes. First, a mechanism of body transformation to reach the ideal and desired form of a human. Second, the complicated and various extremeness of the whole human body. Third, the reflection of 'elaborate and secular excess, decorative taste of international Gothic style. Fourth, a early advanced case of the Trickle-down fashion and international sensation. Fifth, the aesthetic insight into 'ugliness', ever pursued in 'extreme beauty'. The researcher expects that the results of this study will contribute to the preparation to renew the significance of, and to restore the status of the late Gothic costumes, in terms of costume history, that has been considered as an age of the bizarre tastes.

Investigation of Girdle Wearing of Female College Students (여대생(女大生)의 거들 착용실태(着用實態) 분석(分析))

  • Park, Eun-Joo;Han, Eun-Gyeong
    • Journal of Fashion Business
    • /
    • v.5 no.3
    • /
    • pp.49-61
    • /
    • 2001
  • In this study, girdle wearing was surveyed on the female college students in Seoul and Seoul satellite cities. Data were collected by convenient sampling method, and sample size was 252 subjects in 18 to 29 years. Questionnaire was composed of 5 parts: experience of girdle wearing, the preference of girdle type, degree of dissatisfaction/discomfort in wearing girdle, wear sensation evaluation of girdle fabrics, including demographic and anthropometric data. The results of surveys are as follows: Experience of girdle wearing (season of wearing girdle, main intention of wearing girdle, frequency of wearing, body part to want to be shaped by girdle) was examined. Especially body parts to be shaped by girdle were in order of abdomen > hip > thigh > waist-hip sideline. Therefore, it would be considered that female college students want to care about the shape of abdomen or hip. The long leg panty type was most preferred among the girdle types. The reason of preference of long leg panty type was cost > easiness of putting on-and-off > shaping many body parts at once. For dissatisfaction/discomfort in wearing the commercial girdles, it showed in order of poor ventilation at sweating > static electricity with outer garment > difficult breathing due to pressure > deformation after laundering.

  • PDF

Physiological Response of Human Body by Temperature Change -Part 2: In Priority to Pulse wave- (온도변동에 따른 인체 생리적 반응 -제2보: 맥파를 중심으로-)

  • Kang, Suk-Jung;Kum, Jong-Soo;Kim, Dong-Gyu;Chung, Yong-Hyun;Lee, Nak-Bum
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.23-28
    • /
    • 2007
  • In most existing research, it is difficult to evaluate thermal comfort exactly because of reflecting individual ideal or psychological response by subjective questions. Physiological variable was selected in this study to evaluate objectively thermal comfort. MST was appeared very sensitively in indoor temperature and can express correctly thermal comfort of human body. The results of CSV are different each individual feeling sensation, so is difficult to evaluate detailedly thermal comfort unlike TSV. But the results of PP, AIx, ED, SEVR are greatly related to temperature change. So thermal comfort is evaluated more objectively by using PP, AIx, ED, SEVR on behalf of TSV, CSV. Human body was presented physiological feedback by temperature impetus and specially, tendency of heart rate agree with temperature change. Physiological reaction was showed sufficient possibility availing evaluation index of thermal comfort. In the future another one needs to review beside the selected physiological variable.

  • PDF