• Title/Summary/Keyword: Body Vibration

Search Result 1,153, Processing Time 0.028 seconds

Field Test and FEM Analytical Approach on Body Vibration for 10MW Large Low-Speed Diesel Engine Operated on Land (10MW급 대형 디젤엔진 본체의 구조진동시험 및 해석)

  • Kim, Yeon-Whan;Bae, Yong-Chae;Lee, Hyun;Lee, Young-Shin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.24-29
    • /
    • 2007
  • Low-speed Diesel Engine, 7K60MC-S, in Power Plant have been experienced high vibration frequently since these units were completed the construction works, but they did not have any fundamental vibration solutions up to date. Therefore, several vibration tests and analyses are conducted to identify the root cause of high vibration and to suggest the optimal countermeasures for diesel engine. The 9.25Hz & 25.4Hz vibrations have been observed on main body during operation. The magnitude of engine upper structural vibration is generally similar in horizontal transverse direction. However, differences in the 'Fore' and 'After' vibration magnitude at 9.25Hz occurs due to the inertia momentum added by SCR duct system with the same vibration phase angle. It is analyzed that the excess structural vibration be occurred when the natural frequency of engine body is accessed the exciting sources due to the explosion pressure and the discharge pulsation of 7 cylinders in resonance range.

  • PDF

Analysis of Tactile Effects on the Different Body Parts by the Various Vibration Patterns (다양한 진동 패턴에 따른 신체 부위의 촉감 효과 분석)

  • Lee, Hwan-Mun;You, Yong-Hee;Song, Chan-Ho;Jeong, Jin-Eon;Sung, Mee-Young;Jun, Kyung-Koo;Lee, Sang-Rak
    • 한국HCI학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.163-167
    • /
    • 2008
  • This paper presents the analysis of tactile effects on different body parts according to the various vibration patterns. The experiments use a vibration pad made of 16 vibration elements in the form of $4{\times}4$ array. The vibration elements are controlled by a 8-bit microprocessor. The sound of gunshot initiates a vibration pattern on different body parts and its sensitivity is measured. The analysis of the experiments lead us to conclude that the vibration pad is the most realistic interface for shooting games and the shoulder part is the most sensitive part in the body. In addition, the most effective vibration pattern is the for the pattern which gives the sensation of spreading out from the center to the outside. This study analyzes the relationship between the human body parts and the tactile sensations by the various vibration patterns. The result of this study will be a good reference for user studies in the field of haptics based on the vibration.

  • PDF

Effects of immediate unilateral whole body vibration on muscle performance and balance in young adults

  • Park, Junhyuck;Choi, Wonjae;Lee, Seungwon
    • Physical Therapy Rehabilitation Science
    • /
    • v.2 no.2
    • /
    • pp.115-118
    • /
    • 2013
  • Objective: Whole body vibration training is a relatively new approach for enhancement of muscle strength, physical performance, and balance. The aim of this study was to assess the effect of unilateral whole body vibration training. Design: One group pretest-posttest design. Methods: Sixteen healthy, physically active volunteers participated in this study. Whole body vibration was applied with a frequency of 20 Hz and an amplitude of 3 mm for 3 minutes. Muscle performance and static balance were assessed before and after unilateral whole body vibration training. One leg standing broad jump test was measured to determine muscle performance which is closely linked to lower extremity muscle function. The good balance system was used in evaluation static balance. All test were measured 3 times and the average value was analyzed. Results: Jumping length was significantly improved by 0.11m in all participants after intervention (p<0.05). Among static parameters, significant results were observed where in the eyes opened condition, X-speed (medial-lateral sway) changed from 4.20 mm/s to 4.95 mm/s, Y-speed (anterior-posterior sway) changed from 5.77 mm/s to 6.54 mm/s and velocity moment changed from $12.77mm^2/s$ to $13.57mm^2/s$ (p<0.05). In the eyes closed condition, X-speed changed from 4.34 mm/s to 4.85 mm/s, Y-speed changed from 7.84 mm/s to 8.16 mm/s and velocity moment changed from $16.03mm^2/s$ to $16.11mm^2/s$ (p<0.05). Conclusions: Immediate unilateral whole body vibration improved muscle performance but impaired static balance in young adults.

The effect of whole body vibration on lower joints in vertical jump (전신진동운동이 수직점프 시 하지관절에 미치는 영향)

  • Yi, Jae-Hoon
    • Journal of Digital Convergence
    • /
    • v.14 no.6
    • /
    • pp.513-518
    • /
    • 2016
  • The Mechanisms of whole body vibration on the human body is not clearly presented despite of the research result and there is not enough research that shows the effects of vibration on the kinetic changes of the lower joint. Therefore, this study focuses on finding out which lower joint is related with kinetic vertical jump ability. Five male and five female who didn't have orthopedic history were selected as the subjects. The subjects carried out three squat jumps before and after 5minutes of 30Hz whole body vibration. We have utilized a 3D motion analysis system to analyze the kinetic changes of the lower joint in the vertical jump. The height of subjects squat jump was improved after whole body vibration treatment. Also, the lower joint moment and power increased. However, there were no statistically significant changes in GRF, hip joint moment and power after the whole body vibration proved to have positive effect on the ankle and knee joints but showed negative effect on the hip joint.

Body Vibration Compensated Laser Doppler Vibrometer using Adaptive Filtering (적응필터링 기법을 사용하여 자체진동을 보상하는 레이저 도플러 진동측정계)

  • 최성욱;조영균;김호성;장태규;강민식
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.11
    • /
    • pp.516-520
    • /
    • 2003
  • A novel dual beam heterodyne Laser Doppler Vibrometer (LDV) in conjunction with FM demodulators, which utilizes a residual beam to eliminate the perturbationdue due to the vibrometer body vibration without any external reference surface, has been developed. Residual laser beam from the beam splitter is used to pick up the vibration of damper, which is mounted in the vibrometer, and combined with reference beam at the photodetector. The output signal of this detector and main signal are processed to extract the object vibration, using a least mean square adaptive algorithm. It is shown experimentally that the body vibration of 1-5 Hz can be effectively removed from the measured signal using DSP technology to extract unperturbed 100 Hz original signal.

Noise and Vibration Characteristics of Concrete Floor Structures Using Resilient Materials Driven by Standard Heavy Impact Source (완충재 유무에 따른 표준중량충격원에 의한 콘크리트 바닥 구조의 소음 및 진동 특성)

  • 송희수;전진용;서상호
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.8
    • /
    • pp.661-667
    • /
    • 2004
  • The characteristics of noise and vibration by a heavy impact source was studied. The triggering method was used for increasing the reliability and stability to measure the level of sound pressure. sound intensity and vibration acceleration. A simple finite element model and a rigid body analysis method were suggested to calculate the natural frequencies of the multi-layer floor system. The results show that the resilient materials decrease the natural frequency of the reinforced concrete slab, make a resonance with dominant driving frequency in the low frequency region, and increase the vibration and noise level. A simple finite element model and rigid body models was suggested to calculate the natural frequencies of the floor systems.

Experimental study on vibration transfer characteristics of automotive seats (자동차 의자류의 진동 전달특성에 대한 실험적 연구)

  • 정완섭;우춘규;박세진;김수현
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.10a
    • /
    • pp.365-370
    • /
    • 1996
  • This paper introduces experimental results of whole-body vibration exposed through the contact area between automotive seat and human body. Such vibration experiment was carried out for five automotive seats in use and four Korean individuals. Interestingly, the quantitative assessment of the ride values of the tested seats do not only enable us to judge the footnotes the Korean technology in automotive seat has left so far, but also lead to the systematic way of improving their ride quality, in addition in Korean automotive seats raised in this paper.

  • PDF

Analysis of Equal Sensation Curves for the Korean People about Vertical Whole-Body Vibration (앉은 자세 수직축 전신 진동에 대한 한국인의 등감각 곡선 분석)

  • Kim, Kun-Woo;Kim, Min-Seok;Yoo, Wan-Suk
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.1
    • /
    • pp.105-111
    • /
    • 2010
  • In the field of 'Human Vibration', it has been interested subjects to make equal sensation curves related to translational and rotational direction of whole-body, hand-transmitted and head-transmitted vibration, etc. When we consider the vibration of a vehicle, the main factor is vertical whole-body vibration. Until now, most of equal sensation curves used to derive frequency weighting function had been made using Western people. However, because of the inherent differences (for example, characteristic and shape of body parts, muscular and cellular tissue) between the Western people and the Oriental people, equal sensation curves based on Oriental people might be required. Also, the weight differences between the samples which consist of average-weighted and over-weighted group might cause the difference of equal sensation curves. So, in this study, 20 male Korean people were used to find equal sensation curves subject to vertical whole-body vibration on seated posture. Among 20 males, an over weighted group consisted of 10 male persons and an average weighted group was the others. Integrating and analyzing the data of two groups, some of non-parametric tests such as 'The Wilcoxon Signed Rank Test' and 'The Mann Whitney U test' were used.

An Analysis of the Vibration Characteristics through the Human Body (인체 내부에서의 진동 전달특성 분석)

  • 전종원;진용옥
    • The Journal of the Acoustical Society of Korea
    • /
    • v.19 no.7
    • /
    • pp.59-65
    • /
    • 2000
  • This paper describes the analysis of vibration characteristics through the human body as the research for voice therapy and diagnosis. The oscillation signal is not external forces but the self-voice to be pronounced the vowels ('a', 'e', 'i', 'o', 'u'). The experiment system consists of microphones, accelerometers and amplifiers. The input data are stored by the computer. At the same time, the voice is stored by the microphone and the vibration signal of the human body is stored by accelerometer. The 63 points are appointed in head, neck, trunk of human body. The positions and number of times are changeable by the purpose. The analysis parameters are amplitude, phase, fundamental. frequency, formant and the correlation of vibration signal and voice is measured by coherence function. The results show that the vibration signals have characteristic vibration in the positions of human body.

  • PDF

Effect of Wholebody Vibration Stimulation According to Various Frequencies on Ankle Instability, Ankle Range of Motion and Balance Ability in Adult with Chronic Ankle Instability (다양한 주파수에 따른 전신진동자극 훈련이 만성 발목 불안정 성인의 발목 불안정 정도, 관절가동범위, 균형능력에 미치는 영향)

  • Jin, Yeon-Sang;Choi, Yoon-Hee;Shim, Jae-Kwang;Cha, Yong-Jun
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.13 no.1
    • /
    • pp.63-72
    • /
    • 2018
  • PURPOSE: The aim of this study was to compare the effect of whole body vibration stimulation on ankle instability, ankle range of motion, and balance ability in adult with chronic ankle instability. METHODS: Forty-five adult with chronic ankle instability were randomly equally allocated the I group (whole body vibration stimulated at 10 Hz), or the II group (20 Hz), or the III group (25 Hz). All the participants (male:13/female: 32, age: $26.64{\pm}3.14$) in this study received whole body vibration therapy for an additional 15 minutes after hot pack and ultrasound three times a week for four weeks. Outcome were measured before and after 4 weeks training. RESULTS: All the three groups showed significant differences in AII and CAIT after intervention (p<.05). I group showed the most significant difference (p<.05). All the three groups also showed significant increase in ankle dorsiflexion and plantar flexion after training (p<.05). I group showed greater increase than the other groups in ankle dorsiflexion (p<.05). The X-axis, Y-axis, and fluctuation speed were significantly decreased in the three groups (p<.05), but there was no significant difference between the three groups after the intervention. CONCLUSION: The findings suggest that the whole body vibration stimulation according to various frequencies is effective for improve ankle instability, ankle range of motion and balance ability in adult with chronic ankle instability. 10 Hz whole body vibration stimulation could help improve ankle instability and ankle range more effectively than other frequencies.