• Title/Summary/Keyword: Body Movement

Search Result 1,534, Processing Time 0.023 seconds

Peroneal Muscle and Biceps Femoris Muscle Activation During Eversion With and Without Plantarflexion in Sitting and Side-lying Postures

  • Do-eun Lee;Jun-hee Kim;Seung-yoon Han;Oh-yun Kwon
    • Physical Therapy Korea
    • /
    • v.31 no.1
    • /
    • pp.18-28
    • /
    • 2024
  • Background: Lateral instability of the ankle is one of the most common causes of musculoskeletal ankle injuries. The peroneus longus (PL) and peroneus brevis (PB) contribute to ankle stability. In early rehabilitation, isometric exercises have been selected for improvement of ankle stability. To effectively train the peroneal muscles during eversion, it is important to consider ankle and body posture. Objects: This study aimed to compare activation of the PL, PB, and biceps femoris (BF) muscles during eversion in different ankle postures (neutral [N], plantarflexed [PF]) and body postures (sitting and side-lying). Methods: Thirty healthy individuals with no history of lateral ankle sprains within the last 6 months were included in the study. Maximal isometric strength of eversion and muscle activation were measured simultaneously. Muscle activation at submaximal eversion was divided by the highest value obtained from maximal isometric eversion among the four postures (percent maximal voluntary isometric contraction [%MVIC]). To examine the differences in muscle activation depending on posture, a 2 × 2 repeated measures analysis of variance (ANOVA) was conducted. Results: There were significant interaction effects of ankle and body postures on PL muscle activation and evertor strength (p < 0.05). The PL muscle activation showed a significantly greater difference in the side-lying and PF conditions than in the sitting and N conditions (p < 0.05). Evertor strength was greater in the N compared to the PF condition regardless of body posture (p < 0.05). In the case of PB and BF muscle activation, only the main effects of ankle and body posture were observed (p < 0.05). Conclusion: Among the four postures, the side-lying-PF posture produced the highest muscle activation. The side-lying-PF posture may be preferred for effective peroneal muscle exercises, even when considering the BF muscle.

The Study of Correlations between Body Compositions and Bone Mineral Density in Young Women and Postmenopausal Women with Low Bone Mineral Density (젊은 여성과 대퇴경부 저골밀도 폐경기 여성의 신체조성과 골밀도의 상관관계 연구)

  • Shin, Seung-Sub
    • PNF and Movement
    • /
    • v.9 no.4
    • /
    • pp.23-31
    • /
    • 2011
  • Purpose : The aim of this study was to investigate the correlations between body compositions and bone mineral density in young women and postmenopausal women with low bone mineral density. Methods : Eleven young women (age, $25.85{\pm}1.96yrs$; height, $160.28{\pm}2.16cm$; weight, $56.89{\pm}9.66kg$) and ten postmenopausal women (age, $25.85{\pm}1.96yrs$; height, $160.28{\pm}2.16cm$; weight, $56.89{\pm}9.66kg$) with low bone density on femur neck were participated in this study. All subjects performed the measure of body composition and BMD on lumbar body and femur neck. Results : The results were as follows. Percent body fat, waist-hip ratio and body mass index(BMI) were significantly increased in postmenopausal women. BMD in lumbar body and femur neck were significantly decreased in postmenopausal women. There were negative strong correlation between BMD of the femur and age in young women. There were negative strong correlation between BMD of the femur and age or the years of menopause in postmenopausal women. There were positive strong correlation between BMD of the femur and BMD of lumbar body. Conclusion : Percent body fat and BMI were more increased in young women than in postmenopausal women. And there were negative strong correlation between BMD and age or the years of menopause in postmenopausal women.

Empathy Evaluation Method Using Micro-movement (인체 미동을 이용한 공감도 평가 방법)

  • Hwang, Sung Teac;Park, SangIn;Won, Myoung Ju;Whang, Mincheol
    • Science of Emotion and Sensibility
    • /
    • v.20 no.1
    • /
    • pp.67-74
    • /
    • 2017
  • The goal of this study is to present quantification method for empathy. The micro-movement technology (non-contact sensing method) was used to identify empathy level. Participants were first divided into two groups: Empathized and not empathized. Then, the upper body data of participants were collected utilizing web-cam when participants carried expression tasks. The data were analyzed and categorized into 0.5 Hz, 1 Hz, 3 Hz, 5 Hz, 15 Hz. The average movement, variation, and synchronization of the movement were then compared. The results showed a low average movement and variation in a group who empathized. Also, the participants, who empathized, synchronized their movement during the task. This indicates that the people concentrates with each other when empathy has been established and show different levels of movement. These findings suggest the possibility of empathy quantification using non-contact sensing method.

A gait control algorithm to change the direction for a walking robot (보행 로보트의 방향전환을 위한 걸음새 제어 알고리즘)

  • 박성혁;황승구
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10a
    • /
    • pp.103-108
    • /
    • 1988
  • A walking robot must have the ability to change the body direction in order to avoid the obstacles. In this paper, we develop a gait control algorithm that can maintain the stable movement of the robot for three different modes of changing directions. The algorithm makes it possible for the robot to have the larger gait stability margin than the threshold value by the method of changing the body speed.

  • PDF

Neurodegenerative Dementias: A Brief Review

  • Sin, Mo-Kyung;Khemani, Pravin
    • Journal of Korean Biological Nursing Science
    • /
    • v.22 no.3
    • /
    • pp.172-175
    • /
    • 2020
  • Purpose: The purpose of this paper is to provide nurses with a concise review on neurodegenrative dementias. This review includes pathophysiology, clinical course, and tips on management of dementias from Alzheimer's disease (AD), Parkinson disease (PD) and lewy body dementia (LBD). Considering increasing numbers of dementia cases among older adults, nurses who are cognizant about dementia care are instrumental in maximizing daily activities and quality of life of patients with cognitive impairment and dementia.

A Study on the Lighting for Dancing Art (무용예술을 위한 무대조명에 관한 연구)

  • Lee, Jang-Weon;Yi, Chin-Woo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.218-223
    • /
    • 2009
  • Even though the movement of human body contruct the primary factor of Dancing Art, spectators appreciate more meaningful expression of the stage that stand above limited space and time. Lighting is a distinctive expressive mechanism of obvious line, form and rhythem of human body by marking a light and shade through artificial beams into the stage. As Dancing art is different from drama, lighting of dancing stage should be distinguished from that of drama stage.

  • PDF

An Establishment of Crotch Ease of Men's Slacks for Lower Body Mobility (하지 동작에 적합한 남성복 슬랙스의 밑위길이 여유분 설정에 관한 연구)

  • Kim, Young-Hee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.4
    • /
    • pp.553-561
    • /
    • 2008
  • The purpose of this research was to analyze the relationship between the ease of crotch depth and the mobility of leg movement. Ten Korean men were participated as subjects and 0. 3, 6cm of crotch ease were inserted for test clothes. To analyze objectively, range-of-motion of four selected movements was measured by Leighton flexometer and goniometer. Also. wearer acceptability rating was measured for subjectively investigation. Anova and Duncan's range tests were used for statistical analysis. According to the results, 3cm of crotch ease was most comfortable. The mobility of test clothes with 3cm crotch ease was improved largely in every test movement(16.2% and 16.6% in segittal plane, and 6.1% and 6.2% in frontal motion).

Effect of preparation of organic ferroelectric P(VDF-TrFE) nanostructure on the improvement of tennis performance

  • Qingyu Wang
    • Advances in nano research
    • /
    • v.14 no.4
    • /
    • pp.329-334
    • /
    • 2023
  • Organic ferroelectric material found vast application in a verity of engineering and health technology fields. In the present study, we investigated the application of the deformable organic ferroelectric in motion measurement and improving performance in tennis players. Flexible ferroelectric material P(VDF-TrFE) could be used in wearable motion sensors in tennis player transferring velocity and acceleration data to collecting devises for analyzing the best pose and movements in tennis players to achieve best performances in terms of hitting ball and movement across the tennis court. In doing so, ferroelectric-based wearable sensors are used in four different locations on the player body to analyze the movement and also a sensor on the tennis ball to record the velocity and acceleration. In addition, poses of tennis players were analyzed to find out the best pose to achieve best acceleration and movement. The results indicated that organic ferroelectric-based sensors could be used effectively in sensing motion of tennis player which could be utilized in the optimization of posing and ball hitting in the real games.

A Study of In-sole Plantar Pressure Distribution in Functional Tennis Shoes (기능성 전문테니스화의 족저압력분포 분석)

  • Lee, J.S.;Kim, Y.J.;Park, S.B.
    • Korean Journal of Applied Biomechanics
    • /
    • v.14 no.3
    • /
    • pp.99-118
    • /
    • 2004
  • The aim of this study is to evaluate tennis shoes's plantar pressure distribution in tennis prayers and to determine the influence of the shoe on various tennis movements. When investigating the biomechanics of movement in tennis, one of the first things to do is to understand the movement patterns of the sport, specifically how these patterns relate to different tennis shoes. Once these patterns are understood, footwear company can design tennis shoes that match the individual needs of tennis players. Plantar pressure measurement is widely employed to study foot function, the mechanical pathogenesis for foot disease and as a diagnostic and outcome measurement tool for many performance. Measurements were taken of plantar pressure distribution across the foot and using F-Scan(Tekscan Inc.) systems respectively. The F-Scan system for dynamic in-shoe foot pressure measurements has enabled us to assess quantitatively the efficacy of different types of footwear in reducing foot pressures. The Tekscan F-Scan system consists of a flexible, 0.18mm thick sole-shape having 1260 pressure sensors, the sensor insole was trimmed to fit the subjects' right, left shoes. For this study 4 university male, high level tennis players were instructed to hit alternated forehand stroke, backhand stroke, forehand volley, backhand volley, smash, service movement in 4 different tennis shoes. 1. When impact in tennis movement, peak pressure distribution of landing foot displayed D>C>B>A, A displayed the best low pressure distribution. A style's tennis shoes will suggest prayer with high impact. If prayer with high impact feeling during pray in tennis wear A style, it will decrease injury, will have performance improvement. 2. When impact in tennis movement, plantar pattern of pressure distribution in landing foot displayed B>A>C>D in stability performance. During tennis, prayer want to stability movement suggest B style tennis shoes when tennis movement impact keep stability of human body. B style tennis shoes give performance improvement 3. When impact in tennis movement, plantar pattern of center of force(C.O.F.)trajectory in landing foot analyzed this : 1) When stroke movement and volley movement in tennis, prayer better to rearfoot movement. 2) when service movement, prayer midfoot strike movement. 3) when smash movement, prayer have forefoot strike movement.

Monitoring Activity for Recognition of Illness in Experimentally Infected Weaned Piglets Using Received Signal Strength Indication ZigBee-based Wireless Acceleration Sensor

  • Ahmed, Sonia Tabasum;Mun, Hong-Seok;Islam, Md. Manirul;Yoe, Hyun;Yang, Chul-Ju
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.29 no.1
    • /
    • pp.149-156
    • /
    • 2016
  • In this experiment, we proposed and implemented a disease forecasting system using a received signal strength indication ZigBee-based wireless network with a 3-axis acceleration sensor to detect illness at an early stage by monitoring movement of experimentally infected weaned piglets. Twenty seven piglets were divided into control, Salmonella enteritidis (SE) infection, and Escherichia coli (EC) infection group, and their movements were monitored for five days using wireless sensor nodes on their backs. Data generated showed the 3-axis movement of piglets (X-axis: left and right direction, Y-axis: anteroposterior direction, and Z-axis: up and down direction) at five different time periods. Piglets in both infected groups had lower weight gain and feed intake, as well as higher feed conversion ratios than the control group (p<0.05). Infection with SE and EC resulted in reduced body temperature of the piglets at day 2, 4, and 5 (p<0.05). The early morning X-axis movement did not differ between groups; however, the Y-axis movement was higher in the EC group (day 1 and 2), and the Z-axis movement was higher in the EC (day 1) and SE group (day 4) during different experimental periods (p<0.05). The morning X and Y-axis movement did not differ between treatment groups. However, the Z-axis movement was higher in both infected groups at day 1 and lower at day 4 compared to the control (p<0.05). The midday X-axis movement was significantly lower in both infected groups (day 4 and 5) compared to the control (p<0.05), whereas the Y-axis movement did not differ. The Z-axis movement was highest in the SE group at day 1 and 2 and lower at day 4 and 5 (p<0.05). Evening X-axis movement was highest in the control group throughout the experimental period. During day 1 and 2, the Z-axis movement was higher in both of the infected groups; whereas it was lower in the SE group during day 3 and 4 (p<0.05). During day 1 and 2, the night X-axis movement was lower and the Z-axis movement was higher in the infected piglets (p<0.05). Overall, the movement of infected piglets was altered, and the acceleration sensor could be successfully employed for monitoring pig activity.