• Title/Summary/Keyword: Body Composition Analyzer

Search Result 53, Processing Time 0.023 seconds

The Clinical Study on the Effect of Reduction in Body Weight and the Change of Body Composition after Fasting Therapy (절식요법의 체중감량효과와 체성분 변화에 대한 관찰)

  • Kim, Sung-Soo;Shin, Hyun-Dae;Shin, Seung-Uoo
    • Journal of Korean Medicine for Obesity Research
    • /
    • v.3 no.1
    • /
    • pp.25-35
    • /
    • 2003
  • Objectives : This study was aimed to investigate the change of the reduction in body weight and the change of body composition after fasting therapy, Chulsikyopub, which was put into practice in Dept. of oriental rehabilitation medicine at Kyung Hee oriental hospital. Method : We measured body weight, body composition, and the degree of obesity 2 weeks after fasting therapy and 10 weeks after fasting therapy with body composition analyzer(Inbody 2.0). Statistical comparisons between pre-therapy group and post-therpay group were done by paired t-test and Wilcoxon's signed rank test. Results : 2 weeks after fasting therapy, body weight was decreased 7.33kg(9.18%), body fat was decreased 2.47Kg(7.24%), muscle weight was decreased 4.66kg(11.37%), body fat ratio was increased 1.08%, and body metabolic rate(BMR) was decreased 118.23kcal(8.22%). 10 weeks after fasting therapy, each of body weight and fat was decreased 10.4Kg, muscle weight was increased 0.3Kg(0.7%), body fat ratio was decreased 7.9%, and BMR was increased 6.8Kcal(0.47%). But muscle weight and BMR did not satisfy statistical significance. Conclusions : fasting therapy for 10 weeks reduced body weight and body fat statistically significant without loss of muscle weight and BMR.

  • PDF

Basic Research to Provide Severity Evaluation Criteria of Postpartum Edema (산호부종의 중증도 평가 기준 마련을 위한 기초 연구)

  • Choi, Min-Sun;Kim, Dong-Il
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.21 no.4
    • /
    • pp.207-217
    • /
    • 2008
  • Purpose: To provide Diagnostic Criteria and Severity Evaluation Criteria of postpartum edema mainly complained by women directly after delivery. Methods: We analyzed Edema Index(ECF/TBW) analyzed by Body Composition Analyzer(InBody720) of 103 women directly after delivery who were delivered in Ob & Gy of Dongguk University Ilsan Hospital. Results: Mean value for Edema Index of 103 participants was 0.3527$\pm$0.0102, Minimum was 0.336, Maximum 0.388. From this Mean value and Edema Index distribution of participants, We suggest that we can diagnose more than 0.35 of Edema Index as Postpartum Edema, more than 0.35 and less than 0.36 as postpartum edema grade 1, more than 0.36 and less than 0.37 as grade 2, more than 0.37 as grade 3. Conclusion: This research is the first step for diagnostic criteria of postpartum edema, we suggest that diagnostic criteria of postpartum edema is more than 0.35 of Edema Index score. But this suggestion must be revaluated by additional research.

  • PDF

The Effect of an Exercise Program on Body Composition and Physical Fitness in Obese Female College Students (운동프로그램이 비만여대생의 신체조성과 체력에 미치는 영향)

  • Kim, Hyang-Dong;Park, Jeong-Sook
    • Journal of Korean Academy of Nursing
    • /
    • v.36 no.1
    • /
    • pp.5-14
    • /
    • 2006
  • Purpose: This study was done to analyze the effects of an exercise program on body composition and physical fitness of obese female college students. Method: Data was collected from September 29, 2003 to December, 29, 2003. The research design was arandomized control group pretest-posttest experimental design. The subjects were college nursing students at K University. Forty four students, 20 in the experimental group and 24 ina control group, with more than $30\%$ body fat were randomly assigned. The subjects in the experimental group participated in an exercise program for 12 weeks, sixty minutes per session, five times per week. Body composition and physical fitness was measured by a body composition analyzer, cardiovascular endurance, muscle endurance, muscle strength(grip strength, back strength), flexibility, balance, agility(whole body reaction time) and power(standing long jump). Result: Body weight(F=4.76, p=0.035), body fat(kg)(F=5.68, p=0.022) and body mass index(F=5.73, p=0.021) of the experimental group were significantly different from the control group, but there were no significant differences in body fat($\%$), lean body mass, muscle mass and WHR. Back strength(F=6.50, p=0.015), flexibility(F=14.62, p=0.000), muscle endurance(F=7.98, p=0.007), power(F=5.76, p=0.02l) and balance(F=2.46, p=0.018) of the experimental group were significantly different from the control group, but there were no significant differences in cardiovascular endurance, grip strength or agility. Conclusiton: The exercise program was effective in improving body weight, body fat(kg), body mass index, back strength, muscle endurance, flexibility, balance and power of obese female college students.

Body Composition, Blood Pressure, Blood Lipids, and Glucose according to Obesity Degree by Body Fat Percentage in Female University Students (여대생의 체지방률분류 비만도에 따른 체성분, 혈압, 혈중지질 및 혈당)

  • Jang, Eun Hee;Park, Young Rye
    • Journal of Korean Biological Nursing Science
    • /
    • v.14 no.4
    • /
    • pp.231-238
    • /
    • 2012
  • Purpose: The purpose of this study was to investigate body composition, blood pressure, blood lipids, and glucose according to obesity degree by body fat percentage in female university students. Methods: A total of 231 subjects were participated between July and December 2010. The anthropometric measures and blood analyzer were used. Data were analyzed using descriptive statistics, ANOVA, and Pearson's correlation coefficient with SPSS 18.0. Results: Percentage of body fat (PBF)-defined obesity had higher prevalence than body mass index (BMI)-defined obesity. Weight, BMI, PBF, fat mass, Waist to hip ratio (WHR), Systolic blood pressure (SBP), Diastolic blood pressure (DBP) in obesity group were higher than normal group and Soft lean mass and Low density lipoprotein (LDL) in obesity group were lower than normal group. There were significant correlations between PFB, SBP, DBP, Triglyceride (TC), High density lipoprotein (HDL), and LDL. Conclusion: In conclusion, when screening for obesity in female university students, body fat should be considered. It is needed to develop obesity management program according to obesity degree and to identify the effectiveness.

The Effect of Electrical Stimulation of Body Composition in Obese Person (전기자극이 체성분에 미치는 효과)

  • Kim, Yong-Seong;Bang, Sang-Bun
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.2 no.3
    • /
    • pp.13-24
    • /
    • 2004
  • The purpose of this study is to reveal the effect of electrical stimulation of body composition in obese person. Subjects were 30s to 40s aged healthy workers(2004. 3. 8~4. 17) in the S general Hospital in Suwon and they were brought to manage obesity. Subjects were divided into control group(Female<0.85, Male<0.90) and study group(Female>0.85, Male>0.90) by WHR(waist-hip ratio) that is measured by Automatic body composition analyzer(InBody 3.0). And we divided the study group with randomized methods into group A(n=8) and group B(n=8). Then we compared and analyzed the change of muscle mass, body fat, abdominal girth, WHR, BMI(body mass index) after application of electrical stimulation, three times a week, for 30 minutes in each session with 50 Hz of pulse frequency, $20\;{\mu}s$ or $250\;{\mu}s$ of pulse duration. There was statistically meaningful decrement of body fat(p<0.05) and abdominal girth(p<0.05) but not of body weight, muscle mass, WHR and BMI in the control group after application of electrical stimulation with 50 Hz, $20\;{\mu}s$. There were meaningful change of abdominal girth(p<0.05), WHR(p<0.05) and BMI(p<0.05), but not of body weight, muscle mass and body fat after application of electrical stimulation with 50 Hz, $20\;{\mu}s$ in group A. We applied electrical stimulation with 50 Hz, $250\;{\mu}s$ in group B, then there were meaningful change of body weight(p<0.05), body fat(p<0.01), abdominal girth(p<0.01), WHR(p<0.05) and BMI(p<0.01) but not of muscle mass only. Consequently, the pulse duration is the main parameter of electrical stimulation that affect the body composition of obese person in this study and if we combined the diet control to reduce blood components we could have better result. So it would be more effective to manage localized obesity(in abdomen, thigh, upper arm, etc.) if you apply electrical stimulation considering the pulse duration.

  • PDF

Effects of Smoking, Drinking, Exercise on Body Composition, Nutrient Intakes and Serum Lipids in Male High School Students (흡연, 음주, 운동이 남자 고등학생의 체성분, 영양소 섭취 및 혈청 지질 양상에 미치는 영향)

  • 김정희;전영인
    • Korean Journal of Community Nutrition
    • /
    • v.9 no.1
    • /
    • pp.19-28
    • /
    • 2004
  • This study was done to investigate effects of smoking, drinking and exercise on body composition, dietary intakes, serum lipids of male high school students in Seoul. Body Composition was analyzed by the Bioelectrical Impedance Fatness Analyzer. Dietary survey was conducted by 24-hour recall method and nutrient intakes were analyzed by the Computer Aided Nutritional analysis program for professional (CAN-Pro). All data were statistically analyzed by SAS PC package program. Mean and standard error were examined for each items. The significant difference was examined by student's t-test. Body composition data showed that protein mass, mineral mass and lean body mass of regular exercisers were significantly higher (p < 0.05) than those of irregular exercisers. Energy and protein intakes of male high school students were 1868 kcal/day (69.2% RDA), 68 g/day (91.3% RDA), respectively. Ca, Fe and Vitamin B$_2$ intakes were lower than 2000 RDA. Analysis of serum lipids showed that serum levels of HDL-cholesterol of drinkers were significantly higher (p < 0.05) than those of nondrinkers. Overall results imply that smoking and alcohol drinking of adolescent males may not much influence on serum lipids levels because pack-years of smoking or the amount of alcohol drinking was not serious enough to be harmful to health.

A Study on Body Composition and IADL of the Elderly according to the Sex (성별에 따른 노인의 신체조성과 IADL에 관한 연구)

  • Um, Ki-Mai;Yang, Yoon-Kwon
    • Journal of Korean Physical Therapy Science
    • /
    • v.7 no.1
    • /
    • pp.321-331
    • /
    • 2000
  • The purpose of this study was to investigate the difference of body composition and IADL of between male elder and female elder. (This study consisted of elder male(n=10) and elder female(n=10),) The mean age of elder male and female was 67.20, 67.50 years. The data were analyzed with t-test, using SPSS PC+ program. Body composition was measured using Inbody 2.0(seoul, korea) of segmental multi-frequency impedance analyzer technique. IADL was measured with Philadelphia Geriatric Center IADL. The result of this study were the following: 1. The difference of Body composition 1) The %fat of elder female was significantly(p<0.05) higher than elder male by 11.48%. 2) The fat mass(kg) of elder female was significantly(p<0.05) higher than elder male by 6.28kg. 3) The free fat mass(kg) of elder male was significantly(p<0.05) higher than elder female by 9.03kg. 4) The muscle mass(kg) of elder male was significantly(p<0.05) higher than elder female by 8.63kg. 5) The WHR(%) elder female was no significantly higher than elder male by 0.03%. 6) The TBW(l) of elder male was significantly(p<0.05) higher than elder female by 6.321. The factor of significant difference of between elder male and female was %fat, fat mass(kg), free fat mass(kg), total body water(l). 2. The difference of IADL 1) IADL of elder male was no significantly higher than elder female by 1.20. As a result of this study, optimal body composition group was elder male group. Optimal body composition of elder had improved IADL. In addition to, this result of this study, it can suggested the consideration of the Health promotion program for elder.

  • PDF

The Correlational Study of Health Promotion Lifestyle and Body Composition in a University Students (일개 대학생의 건강증진 생활양식과 신체조성간의 관계 연구)

  • Park, Yeon-Suk;Lee, Hye-Gyeong
    • Journal of the Korean Society of School Health
    • /
    • v.19 no.1
    • /
    • pp.67-78
    • /
    • 2006
  • Purporse : The purpose of this study was to examine the relationship between a health promoting lifestyle and body composition in university students. The study subjects were 194 university students who attended K-university located in Chungnam. Methods : The data was collected between March 2 and May 31, 2004. The instrument used for this study was the modified Health Promoting Lifestyle Profile(HPLP) developed by Walker, Sechrist, & Pender(1987). The body composition was measured by In Body 3.0, a Bioelectrical Impedance Analyzer. The data was analyzed using the SPSS/WIN 10.0 program by t-test, ANOVA and pearson correlation coefficients. Results : The results of this study are as follows: 1) The scores of the Health Promoting Lifestyle(HPL) ranged from 79 to 170, with a mean score of 110(±15.8). The mean scores of sub-categorical HPL were self-actualization 31.8(±4.9), health responsibility 17.0(±4.0), exercise 8.3(±3.2), nutrition 15.4(±3.7), interpersonal relationships 20.3(±3.5) and stress management 17.2(±3.4). 2) The HPL according to the subjects' general characteristics had significant correlation to exercise amount(F=8.09, p<.01), drinking amount(F=6.56, p<.01), perceived health status(F=19.2, p<.01) and perceived health knowledge (F=15.9, p<.01). 3) The total HPL did not significantly correlate with any categories in body composition. The exercise area of sub-categorical HPL had significant positive correlation to height (r=.199, p<.01), weight(r=.181, p<.05) and soft lean mass(r=.257, p<.01), and negative correlation to percent body fat(r=-.255, p<.01) in body composition. Conclusion : The results suggest that the exercise area of sub-categorical HPL was an important variable for an exercise program's development such as nursing intervention for the health promotion of university students.

Correlations between Postpartum Edema and Pulse Energy Measured by 3D Blood Pressure Pulse Analyzer (3D Blood Pressure Pulse Analyzer로 측정한 맥파 에너지와 산후 부종과의 상관성 연구)

  • Lee, Ji-Yeon;Yun, Young-Jin
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.27 no.1
    • /
    • pp.167-175
    • /
    • 2014
  • Purpose: This study was performed to find correlations between Edema Index and Pulse Energy in early postpartum period. Methods: Fiftynine postpartum women were participated in this study which was conducted with Inbody 720 (Biospace Co. Ltd) and 3D Blood Pressure Pulse Analyzer (3D-MAC). Edema Index (Extra Cellular Water/Total Body Water) calculated after body composition analysis and 3D-MAC result (Pulse Energy) were analysed within a week after delivery. Results: The results were as follows 1. Edema Indexes of the upper, lower limbs, trunk and whole body were associated with each other respectively. 2. Edema Indexes and Right Kwan pulse energy had significant positive correlation. 3. Right Kwan pulse energy showed positive correlations with Left Kwan, Right Chon, Right Cheok. Conclusions: Viscera associated with Postpartum Edema are Spleen, Lung, Liver and Vital Gate. The most important thing is thought to be Spleen.

A Design of Bandpass Filter for Body Composition Analyzer (체성분 측정기용 대역통과 필터 설계)

  • Bae, Sung-Hoon;Cho, Sang-Ik;Lim, Shin-Il;Moon, Byoung-Sam
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.42 no.5 s.305
    • /
    • pp.43-50
    • /
    • 2005
  • This paper describes some IC(integrated circuits) design and implementation techniques of low power multi-band Gm-C bandpass filter for body composition analyzer. Proposed BPF(bandpass filter) can be selected from three bands(20 KHz, 50 KHz, 100 KHz) by control signal. To minimize die area, a simple center frequency tuning scheme is used. And to reduce power consumption, operational transconductance amplifier operated in the sub-threshold region is adopted. The proposed BPF is implemented with 0.35 um 2-poly 3-metal standard CMOS technology Chip area is $626.42um\;{\times}\;475.8um$ and power consumption is 700 nW@100 KHz.