• Title/Summary/Keyword: Body Assembly

Search Result 251, Processing Time 0.025 seconds

Implementation of Digital Laser Welding Cell for Car Side Panel Assembly (차체 사이드 패널 조립을 위한 디지털 레이저용접 셀 구현)

  • Park Hong Seok;Choi Hung Won;Kang Mu Jin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.5 s.170
    • /
    • pp.113-120
    • /
    • 2005
  • Because of the turbulent markets and the increasing demand on product quality, the application of new technology to practice is increasingly important. In case of automotive industries, they take interest in laser welding to solve these problems because laser welding has many advantages such as good accessibility, welding quality, fast welding speed and so on. To apply this technology to welding of car body, the data of laser welding are collected through lots of the experiment according to the material, geometry and layer number of welding points. Based on the experiment results and the information of product, i.e. the car side panel, the clustering of stitches for laser welding was carried out and the optimal equipments are selected through the comparison between the requirements of welding and the potential of equipments. Using these results, laser welding cell for the car side panel are configured with the concept of the digital manufacturing, which ensures maximum planning security with visualization and simulation. Finally, the optimal laser welding cell is chosen by the evaluation of alternative cells with assessment criteria.

Study on Analysis of Vibration Characteristics and Modal Test for a Quad-Rotor Drone (쿼드로터형 드론의 진동특성 분석 및 실험에 관한 연구)

  • Kim, Minsong;Kim, Jaenam;Byun, Youngseop;Kim, Jeong;Kang, Beomsoo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.9
    • /
    • pp.707-714
    • /
    • 2016
  • This paper describes analysis results of vibration characteristics and modal test for a small-scale quad-rotor drone. The rotor arm has a slender body with a propeller and motor at its tip. Rotor system generates excitation for an unbalanced mass. Therefore, the drone platform is involved in the possibility of resonance. For advance identification of the possibility of resonance, confirmation of eigen-mode being closest to the propeller operation range is necessary. Material properties of CFRP tubes used for the rotor arm were acquired by finding the natural frequency based on Rayleigh method. A simplified quad-rotor FE model consisting of rotor arm assembly with tip mass was built to perform numerical analysis, and a free-free boundary condition was applied to provide flight status. Modal tests for the actual platform with impact hammer instrument were performed to verify analysis results. Separation margin from hazardous eigen-mode was checked on the propeller operation range.

Trend Review of Research about Herbal Medicine Treatment on Colorectal Cancer. - Based on Korean Medicine (대장암에 대한 본초 및 처방의 국내 최신 연구 경향 분석)

  • Cha, Jong-Yeol;Kim, Won-Ill
    • Herbal Formula Science
    • /
    • v.27 no.2
    • /
    • pp.151-165
    • /
    • 2019
  • Objectives : To analyze the latest study trend on effect of herbal medicine treatment for Colorectal Cancer in South Korea. Methods : The theses about colorectal cancer(from 1th January 2000 to 6th August 2016) were searched from National Assembly Library, KIOM OASIS, and National Digital Science Library. Results : 54 theses were analyzed from 87 studies. They were classified by the type of research; experimental theses and case report. The number of experimental theses is 48 and case report is 6. And, they were classified by the topic of research; Single herb, Herbal decoction, oriental foods and Pharmacopuncture, the number of theses about single herb is 29, herbal decoction is 14, oriental foods is 8 and Pharmacopuncture is 3. Rhus Verniciflua(乾漆), Beakduong-tang(白頭翁湯), Wild Ginseng Pharmacopuncture is the most commonly used herb in our research. Conclusion : There were many attempts to develop the way to cure colorectal cancer using korean herbs, and some meaningful results were reported. However, more clinical researches based on human body and more scientifically designed clinical studies are required to prove the effect on colorectal cancer.

Development of Muscle-Strength-Assistant Device and Military Suitability for High-Weight Carrying (고중량물 운반을 위한 근력보조장치 개발 및 군 적합성 연구)

  • Kim, Hyeong-Rae;Park, Jang-Sik;Lee, Kyeong-Ha;Ryu, Jae-Kwan
    • The Journal of Korea Robotics Society
    • /
    • v.17 no.2
    • /
    • pp.191-197
    • /
    • 2022
  • In this research, we developed the muscle-strength-assistant device, named as LEXO-W, and conducted suitability test for army when transporting high weights. LEXO-W relieves the burden when carrying heavy weights by distributing the load concentrated on the arms throughout the body. LEXO-W weighs 4 kg and is designed to handle objects weighing up to 55 kg. To verify the effectiveness of the device, object handling tests (high explosive shell, simple assembly bridges, and ammunition boxes) were conducted. Working time, metabolic rate, and electromyogram (EMG) signals were measured in each test. As a result, it was confirmed that the working time, metabolic rate and EMG signal before and after wearing LEXO-W were decreased. This research has great significance in that it verified the performance of the wearable device from the perspective of military operation.

System Improvement Measures for Rational Procedures of Offshore Wind Power Generation Projects : Focusing on Permits (해상풍력 발전사업의 합리적 절차를 위한 제도개선 방안 : 인허가를 중심으로)

  • Seok-Kyu Kang;Jeong-Gab Moon;Mun-Kwan Jo
    • The Journal of Fisheries Business Administration
    • /
    • v.54 no.2
    • /
    • pp.59-76
    • /
    • 2023
  • This study is to propose ways to improve the system for rational procedures for offshore wind power generation projects. The results of this study are summarized as follows. In order to quickly distribute and develop offshore wind power projects, the permitting period should be shortened through special laws, the government actively intervenes to support the formation and operation of privat-public councils to ensure residents' acceptance. In this way, it can be competitive in the future energy market. Above all, a special law (proposal) related to offshore wind power currently pending in the National Assembly should be passed as soon as possible. Finally, the government and local governments that manage public waters should provide active administrative support based on system improvement measures in consideration of these permits, and the project's main body should minimize damage to the marine environment and ecosystem. Through these subject-specific roles, offshore wind power generation will be able to reduce carbon emissions and help establish a sustainable energy production system.

Development of a Silicon Carbide Large-aperture Optical Telescope for a Satellite (SiC를 이용한 대구경 위성용 망원경 제작)

  • Bae, Jong In;Lee, Haeng Bok;Kim, Jeong Won;Lee, Kyung Mook;Kim, Myung-Whun
    • Korean Journal of Optics and Photonics
    • /
    • v.33 no.2
    • /
    • pp.74-83
    • /
    • 2022
  • The entire process, from the raw material to the final system qualification test, has been developed to fabricate a large-diameter, lightweight reflective-telescope system for a satellite observation. The telescope with 3 anastigmatic mirrors has an aperture of 700 mm and a total mass of 66 kg. We baked a silicon carbide substrate body from a carbon preform using a reaction sintering method, and tested the structural and chemical properties, surface conditions, and crystal structure of the body. We developed the polishing and coating methods considering the mechanical and chemical properties of the silicon carbide (SiC) body, and we utilized a chemical-vapor-deposition method to deposit a dense SiC thin film more than 170 ㎛ thick on the mirror's surface, to preserve a highly reflective surface with excellent optical performance. After we made the SiC mirrors, we measured the wave-front error for various optical fields by assembling and aligning three mirrors and support structures. We conducted major space-environment tests for the components and final assembly by temperature-cycling tests and vibration-shock tests, in accordance with the qualifications for the space and launch environment. We confirmed that the final telescope achieves all of the target performance criteria.

The Relation Between Work-Related Musculoskeletal Symptoms and Rapid Upper Limb Assessment(RULA) among Vehicle Assembly Workers (자동차 조립 작업자들에서 상지 근골격계의 인간공학적 작업평가(Rapid Upper Limb Assessment) 결과와 자각증상과의 연관성)

  • Kim, Jae-Young;Kim, Hae-Joon;Choi, Jae-Wook
    • Journal of Preventive Medicine and Public Health
    • /
    • v.32 no.1
    • /
    • pp.48-59
    • /
    • 1999
  • Objectives. This study was conducted to evaluate the association between upper extremity musculoskeletal symptoms and Rapid Upper Limb Assessment(RULA) in vehicle assembly line workers. The goal of this study is to show the feasibility of RULA as a checklist for work related musculoskeletal symptoms (WMSDs) in Korean workers. Methods. The total number of 199 people from the department of assembly and 115 people from the department of Quality Control(QC) in automotive plant were subjects for this cross sectional study. A standard symptom questionnaire survey has been used for the individual characteristics, work history, musculosketal symptoms and non-occupational covariates. The data were obtained by applying one-on-one interview for the all subjects. RULA has been applied for ergonomic work posture analysis and the primary ergonomic risk sure was computed by RULA method. Association between upper extremity musculoskeletal symptoms and RULA were assessed by multiple logistic regression analysis. Results. A total of 314 workers was examined. The prevalence of musculoskeletal symptoms by NIOSH case definition was 62.4%. The distribution of musculoskeletal symptoms by the part of the body turned out to be following; back:41.4%, neck: 32.8%, shoulder: 26.4%, arm: 10.5% and hand:29.3%. The relationship of the individual RULA scores were statistically significant for the prevalence of musculoskeletal symptoms. As the result of the multiple logistic regressioin analysis, grand final score (OR=2.250 95% CI: 1.402-3.612) was associated with musculoskeletal symptoms in any part of the body.; upper arm score(OR=1.786 95% CI: 1.036-3.079) and posture score A(OR=1.634 95% CI: 1.016-2.626) in neck; muscel use score(OR=3.076 95% CI:1.782-5.310) and posture score A(OR=1.798 95% CI: 1.072-3.017) in shoulder; upper arm score(OR=1.715 95% CI: 1.083-2.715) and muscel use score(OR=2.057 95% CI:1.303-3.248) in neck & shoulder; muscle use score(OR=10.662 95% CI: 3.180-35.742) in arm; writst/wist score(OR=2.068 95% CI: 1.130-3.786) and muscle use score(OR=2.215 95% CI: 1.284-3.819) in hand & wrist.; muscle use score of trunk (OR=2.601 95% CI: 1.147-5.901) in back. Conclusions. Musculoskeletal symptoms of the extremities were strongly associated with individual RULA body score. These results show that RULA can be used as a useful assessment tool for the evaluation of musculoskeletal loading which is known to contribute to work-related musculoskeletal disorders. RULA also can be used as a screening tool or incorporated into a wider ergonomic assessment of epidemiological, physical, mental, environmental and organizational factors. As shown in this study, complement of the analysis system for the other risk factors and characterizing between the upper limb and back part will be needed for future work.

  • PDF

Reliability Analysis Using Field-Data of 5.56 mm Rifle (야전운용제원을 이용한 5.56 mm 소총 신뢰도 분석)

  • Shin, Tae-Sung;Seo, Hyun-Soo;Lee, Ho-Jun;Choi, Si-Young;Gil, Hyeon-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.584-591
    • /
    • 2020
  • Reliability is an important factor in weapons systems. Low reliability causes the weapons system to fail to function properly, which directly leads to the weakening of combat capability. This paper classifies the structure of the 5.56 mm rifle, which is currently used by the Korean army, into a total of seven assemblies and describes the eight functions necessary for the rifle to operate normally. In addition, the concept of reliability was defined as the MRBF, and the Poisson process model and TTT plot were explained as a reliability analysis theory for the repair function system. Next, the field-data obtained by defining failure as the replacement of parts other than periodic exchange of parts were refined, and the reliability was analyzed by entering the refined field operation specifications into the Minitab program. As a result, the reliability of the rifle was determined to be 251.73. The assembly parts that required improvement was identified as the barrel, lower body, and butt stock assembly, and 10 detailed parts needed to be improved. Finally, the limits of the reliability analysis using the field-data currently available for small caliber firearms were considered.

Development of Vertical Separated Tubular Steel Pole (종방향 분할형 관형지지물 개발)

  • Lee, Won-kyo;Mun, Sung-Duk;Shin, Kooyong
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.4
    • /
    • pp.257-262
    • /
    • 2019
  • Lattice steel towers for overhead transmission lines have been replaced by tubular steel poles due to the visual impact of large and complex shape of truss type. Demand for tubular steel poles consisting of a single frame member continues to grow because of its advantages such as visual minimization, architectural appeal and minimal site consumptions. However, there are some constraints on the transportation and construction. As the diameter of tower base has been enlarged, it may exceed minimum height limit required to pass the tunnel in case of land transportation. Also, in a narrow place where it is not easy to secure the installation areas such as mountainous places, there might be some areas wherein it must secure a wide working space so that large vehicles and working cranes will be allowed to enter. In this paper, we presented a vertical separated tubular steel pole, which is a new type of support that can be implemented for general purpose such as mountainous areas or narrow areas to improve the issues raised by breaking away from the conventional design and fabrication methods. Technical approaches for overcoming the limit of the cross-sectional size is to separate and modularize the cross-section of the tubular steel pole designed with a size that cannot be carried or assembled, and to lighten it with a weight capable of being transported and assembled in a narrow space or mountainous area. As a result of this research, it will be possible to enter small and medium sized vehicles in locations where it is restricted to transport by large-sized vehicles. In the case of mountainous areas, it will be possible to divide it into a weight capable of being carried by a helicopter and it will be easy to adjust and fabricate it with individual modules. Furthermore, in order to break away from the traditional construction method, we proposed the equipment that can be applied to the assembly of Tubular Steel Pole without using a large crane in locations where there is no accessible road or in locations wherein large cranes cannot enter. In particular, this paper shows the movable assembling equipment and some methods that are specialized for vertical separated tubular steel pole consisting of members with reduced weight. The proposed assembly equipment is a device for assembling the body of the Tubular Steel Poles. It will be installed inside the support and the modules can be lifted by using the support itself.

Association of Bone Lead with Neurobehavioral Test Scores in Lead Workers (연작업자들에서 골중 연량이 신경행동학적 검사성적에 미치는 영향)

  • Lee, Sung-Soo;Kim, Nam-Soo;Kim, Hwa-Sung;Ahn, Kyu-Dong;Lee, Byung-Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.2
    • /
    • pp.144-152
    • /
    • 2005
  • To evaluate the effect of lead biomarkers including bone lead on neurobehavioral test in lead workers, 652 lead workers without any occupational exposure to organic solvent, mercury and arsenic were agreed to participate this study. For the control subjects 102 non-occupationally lead exposed blue collar workers in general manufacturing industries were also joined this study. All study subjects joined this study with written informed consent. The study variables of lead exposure were blood and patella lead. For the general characteristics of study subjects, standardized questionnaire regarding age, sex, past disease history, job duration, body mass index (BMI), drinking and smoking habit were provided. For the past history of neurotoxicity related diseases, all study subjects were interviewed by qualified occupational health physician. The results obtained were as follows: 1. Compared with controls without occupational lead exposure, lead exposed subjects had worse performance on all tests(p<0.05). 2. After adjustment for covariates (age, sex, job duration, education level, BMI, smoking and drinking status), the signs of the regression coefficients for blood lead were negative for 13 of the 14 tests. Blood lead was a significant predictor of poorer scores on 8 tests (simple reaction time(ms & root MSD), Trail-Making Test B, Digit Symbol Substitution, Purdue Pegboard assembly, Digit Span Test, Benton Visual Retention, and Purdue pegboard both hand). 3. After adjustment for covariates (age, sex, job duration, education level, BMI, smoking and drinking status), the signs of the regression coefficients for patella lead were negative for 12 of the 14 tests. Patella lead was a significant predictor of poorer scores on 8 tests (simple reaction time(ms). Purdue Pegboard assembly, Digit Span Test, Benton Visual Retention. Pursuit Aiming rest (no. of correct & no. of incorrect), Purdue pegboard non-dominant hand and both hand). With above results, blood lead and patella lead were associated with poorer performance of neurobehavioral tests. In addition, patella lead was confirmed to be better predictor of manual dexterity test in neurobehavioral test battery in lead workers