• 제목/요약/키워드: Board power

검색결과 1,056건 처리시간 0.034초

VMS(Variable Message Signboard)의 서브 컨트롤부 설계 (Design of Sub Control Part for VMS(Variable Message Signboard))

  • 신재흥;이상철;문성창
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.80-83
    • /
    • 2004
  • Previously, in order to send information from the local controller to the display board, the hardware or software had to be handled and run through 3-phases, which include the PC-card or PC-add Board, I-F card and Sub board. This study will attempt to design a board that handles information by connecting the USB port of the PC directly to the Sub board. In addition, an MPU will be attached to the previously complex hardware circuit to design a software drive engine module, which allows for the development of new products by modifying only the software engine and not the hardware.

  • PDF

One-board micom을 이용한 정밀 온도 제어 시스템 (A precision temperature control system using one-board micom)

  • 주해호;조덕현
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1988년도 한국자동제어학술회의논문집(국내학술편); 한국전력공사연수원, 서울; 21-22 Oct. 1988
    • /
    • pp.457-461
    • /
    • 1988
  • In this study an one-board micom controlled precision temperature control system has been developed. The digital temperature control system is consisted of an one-board micom as digital controller, a 12-bit A/D and D/A converter, a power amplifier, a NTC thermister, a preamplfier and a heat chamber. An operating control program for the control system was written in Z80 machine language. A Dual-PID predictor control algorithm was proposed. Experments were conducted with different sampling time and limitted error value. As a result, the temperature in a heat chamber can be well controlled within +- 0.2 .deg.C when the sampling time was applied to 10 sec and the limitted error value +- 0.5 .deg.C under the dual-PID predictor control algorithm. By means of one-board micom overall system has been reduced in size and volume, thus the system becomes compact and less expensive.

  • PDF

선박용 에너지 절감형 냉각시스템에 관한 연구 (A Study on the Energy Reduced Cooling System for the Ship)

  • 오진석;임명규;진선호;곽준호;조관준;유병랑;배병덕
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.1108-1112
    • /
    • 2005
  • Recently, the fuel charge is accounted for very high in the navigation cost. Therefore Shipowner is tried to find method for reducing oil consumption. ERCS(Energy Reduced Cooling System) is one of the method. The ERCS algorithm operates to decrease a power consumption of main sea water cooling pump through inverter control. We have developed ERCS controller with algorithm. The ERCS controller consists of CPU board, Digital I/O board, A/D board, D/A board and LCD/SW board. We tested with dummy signal to confirm the algorithm working correctly and achieved the good results. Before soon we will test under real condition in the ship and expect to get the result as forecasted.

  • PDF

태양전지를이용한 LED 표식장치 설계 (LED sign board design using solar cells)

  • 이흥주
    • 한국산학기술학회논문지
    • /
    • 제10권9호
    • /
    • pp.2221-2226
    • /
    • 2009
  • 본 논문에서는 태양전지를 기본 전력공급원으로 사용하는 대형건물용 옥외간판 LED 표식장치를 시스템을 구현하였다. 부하 발전 배터리 용량을 산정하고, 상용 예비전력을 도입한 계통연계형 태양광발전시스템을 설계하였다. 표식장치인 LED 부하에 대한 사전 휘도 시뮬레이션 및 균일성 검사를 거친 후, 이를 태양광발전시스템과 함께 설치하였다. 태양전지-LED 표식장치 현장 시험운영을 통하여 시스템의 신뢰성과 성능 및 제반 문제점을 파악하였다.

시뮬레이터 연계용 교육, 훈련 Mimic Board 시스템 개발 (Development of a Simulation Training Simulator using KEPS)

  • 차승태;김태균;최준호;김창곤;이철균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.68-69
    • /
    • 2006
  • A new type of simulation training system for power system operation is presented in this paper It is based on transmission mimic board, double screen PC, mimic control panel, and real-time digital simulator, KEPS. The operating simulation includes the simulations of the control panel interface and the simulator. The mimic board displays transmission network summary information using a software view of the hardware based mimic board. The symbols, numbers and colors layout exactly match those of the KEPS draft case to provide operators a familiar and effective starting point. This paper describes the development of an innovative training system, utilizing the benefits of 3 dimension visualization s/w and communication-control s/w to create the appropriate operational environment and allow simulation of various power system operations without the restrictions of other training methods. Experiences gained in developing concepts and meeting considerable s/w challenges are outlined, and the potential of the simulator for future operations training discussed.

  • PDF

전기안전을 위한 스마트분전반 표준화 연구 (A Study on the Standardization of Smart Distribution Board for Electrical Safety)

  • 문현욱;임용배;김동우;이상익;최명일
    • 전기학회논문지
    • /
    • 제65권1호
    • /
    • pp.227-231
    • /
    • 2016
  • Electrical disasters have not been greatly reduced despite continuous prevention efforts until now. However, the smart distribution board which can be measured information about general electrical condition such as current, voltage, power, power factor etc. and electrical safety condition such as over-current, leakage current, arc etc. and communicated analysis information about electrical condition with server will be helpful for the prevention of electrical disasters through real-time surveillance and data analysis under smart grids based on the two-way communication. In this paper, the proposal standard of smart distribution board for electrical safety is suggested about the structure, functional requirements of compositions, communication, security and so on.

휴대폰 충전기 내 트래킹 발생 원인 분석 및 대책 (Cause Analysis and Countermeasure of Tracking in Mobile Phone Charger)

  • 박진영;김재현;박광묵;방선배
    • 한국화재소방학회논문지
    • /
    • 제30권6호
    • /
    • pp.71-77
    • /
    • 2016
  • 핸드폰 충전기 내 커패시터의 전해액이 전원 입력단자로 누출되고 PCB 기판에 트래킹이 발생하여 탄화도전로가 형성되는 것을 확인하였다. 트래킹이 발생하는 원인을 구조적으로 분석한 결과, 전원 입력단자와 PCB 기판이 커넥터를 이용하여 직결되는 경우에 발생하였다. 커패시터에서 누출된 전해액이 전원입력단자로 흘러 들어가는 양이 많을수록, 전원입력단자의 플러그 핀 사이에 설치된 격벽의 높이가 낮을수록 트래킹 발생율이 높았다. 이에 따라 충전기 내 트래킹 발생율을 낮추기 위해서는 누출된 전해액이 전원입력단자로 흘러 들어가지 않도록 커패시터에 격벽을 설치하거나, 전원입력단자에 설치된 격벽의 높이를 높일 필요가 있다. 또한, 전원 연결단자와 맞닿아 있는 PCB기판의 형태를 ${\Pi}$로 변경한다면 트래킹 발생율이 더욱 줄어들 것으로 판단된다.

DLL 보드 상에 코어 및 I/O 잡음에 의한 칩의 성능 분석 (Analysis of Chip Performance by Core and I/O SSN Noise on DLL Board)

  • 조성곤;하종찬;위재경
    • 마이크로전자및패키징학회지
    • /
    • 제13권4호
    • /
    • pp.9-15
    • /
    • 2006
  • 이 논문은 코어와 I/O 회로가 포함된 PEEC(Partial Equivalent Electrical Circuit) PDN(Power Distribution Networks)의 임피던스 변화에 따른 칩의 성능 분석을 나타내었다. I/O 전원에 연결된 코어 전원 잡음이 I/O 스위칭에 어떠한 영향이 미치는지 시뮬레이션 결과를 통하여 보였다. 또한 직접 설계한 $7{\times}5$인치 DLL(Delay Locked Loop)시험 보드를 사용하여 칩의 동작 지점에 따른 전원 잡음의 효과를 분석하였다. $50{\sim}400MHz$에 주파수 대역에 따른 DLL의 지터를 측정하고 시뮬레이션 결과로 얻어진 임피던스 값과 비교하였다. PDN의 공진 피크가 100MHz 주파수에서 1옴보다 큰 임피던스를 갖기 때문에 DLL의 지터는 주파수가 100MHz 근처에서 증가함을 보여준다. 타겟 임피던스를 줄이기 위한 방법인 디커플링 커패시터에 따른 칩과 보드의 임피던스 변화를 보였다. 따라서 전원 공급망 설계는 디커플링 커패시터와 함께 코어 스위칭 전류와 I/O 스위칭 전류를 같이 고려해야 한다.

  • PDF

6.78MHz, 거리 60cm, 50W급 무선 전력 전송 시스템용 High Quality Factor PCB 코일 개발 (Development of 50W High Quality Factor Printed Circuit Board Coils for a 6.78MHz, 60cm Air-gap Wireless Power Transfer System)

  • 이승환;이경표
    • 한국철도학회논문집
    • /
    • 제19권4호
    • /
    • pp.468-479
    • /
    • 2016
  • 고압 전선 등에 장착된 시스템에 전원을 공급하기 위해서는 절연 이격 거리 이상의 거리에 무선으로 수십 Watt 급의 전력을 보낼 수 있는 시스템이 필요하다. 이러한 무선 전력 전송 시스템은 대개 코일의 크기가 10cm 이상의 대형이다. 본 연구에서는 이처럼 대형 코일을 Printed circuit board를 이용해 제작할 경우 발생하는 손실 발생원 들을 분석하고 그 중 가장 주요한 손실원인이 Dielectric loss 라는 것을 밝혔다. 또한 이 dielectric loss를 최소화 하기 위해서 PCB의 재질 선정 방법 및 Distributed tuning capacitor method를 제시해 $40cm{\times}40cm$ 크기의 4턴 및 5턴 코일의 설계 방법을 제시했고, 실험을 통해 Quality factor를 300 이상으로 만들 수 있음을 보였다.

동기 발전기 시스템의 실시간 모니터링 기술 개발 (A Development of Real-time Monitoring Techniques for Synchronous Electric Generator Systems)

  • 조현철
    • 전기학회논문지P
    • /
    • 제66권4호
    • /
    • pp.182-187
    • /
    • 2017
  • Synchronous generators have been significantly applied in large-scale power plants and its monitoring systems are additionally established to sequentially observe states and outputs. We develop a computer based monitoring device for three-phase synchronous power generators in this paper. First, a test-bed of such generator system is created and then a interface board is constructed to transfer electric signals including the output voltage and the current from generators into a computer system via a data acquisition device. Its RMS(root-mean-square) values are continuously shown on a screen of computer systems and its time-histories graphs are additionally illustrated under a graphic user interface(GUI) mode. Lastly, we carry out real-time experiments using the generator system with the monitoring device to demonstrate its reliability and superiority by comparing results of a generic power analyzer which is well-used in measuring various power systems practically.