• 제목/요약/키워드: Blow-up

검색결과 157건 처리시간 0.02초

GLOBAL SOLUTIONS FOR A CLASS OF NONLINEAR SIXTH-ORDER WAVE EQUATION

  • Wang, Ying
    • 대한수학회보
    • /
    • 제55권4호
    • /
    • pp.1161-1178
    • /
    • 2018
  • In this paper, we consider the Cauchy problem for a class of nonlinear sixth-order wave equation. The global existence and the finite time blow-up for the problem are proved by the potential well method at both low and critical initial energy levels. Furthermore, we present some sufficient conditions on initial data such that the weak solution exists globally at supercritical initial energy level by introducing a new stable set.

GLOBAL EXISTENCE AND NONEXISTENCE OF SOLUTIONS FOR COUPLED NONLINEAR WAVE EQUATIONS WITH DAMPING AND SOURCE TERMS

  • Ye, Yaojun
    • 대한수학회보
    • /
    • 제51권6호
    • /
    • pp.1697-1710
    • /
    • 2014
  • The initial-boundary value problem for a class of nonlinear higher-order wave equations system with a damping and source terms in bounded domain is studied. We prove the existence of global solutions. Meanwhile, under the condition of the positive initial energy, it is showed that the solutions blow up in the finite time and the lifespan estimate of solutions is also given.

FINITE TIME BLOW UP OF SOLUTIONS FOR A STRONGLY DAMPED NONLINEAR KLEIN-GORDON EQUATION WITH VARIABLE EXPONENTS

  • Piskin, Erhan
    • 호남수학학술지
    • /
    • 제40권4호
    • /
    • pp.771-783
    • /
    • 2018
  • This paper, we investigate a strongly damped nonlinear Klein-Gordon equation with nonlinearities of variable exponent type $$u_{tt}-{\Delta}u-{\Delta}u_t+m^2u+{\mid}u_t{\mid}^{p(x)-2}u_t={\mid}u{\mid}^{q(x)-2}u$$ associated with initial and Dirichlet boundary conditions in a bounded domain. We obtain a nonexistence of solutions if variable exponents p (.), q (.) and initial data satisfy some conditions.

NONLINEAR HEAT EQUATIONS WITH TRANSCENDENTAL NONLINEARITY IN BESOV SPACES

  • Pak, Hee Chul;Chang, Sang-Hoon
    • 충청수학회지
    • /
    • 제23권4호
    • /
    • pp.773-784
    • /
    • 2010
  • The existence of solutions in Besov spaces for nonlinear heat equations having transcendental nonlinearity: $$\frac{\partial}{{\partial}t}u-{\Delta}u=F(u)$$ is investigated. In particular, it is proved the local existence and blow-up phenomena of the solutions in Besov spaces for nonlinear heat equations corresponding to two transcendental nonlinear functions $F(u){\equiv}{\mid}u{\mid}e^{u^2}$ and $F(u){\equiv}e^u$ of rapid growth.

안와하내벽 파열골절의 임상적 의의 (Clinical Significance of Orbital Inferiomedial Blow Out Fracture)

  • 유재홍;하원;이지원;양완석
    • 대한두개안면성형외과학회지
    • /
    • 제14권1호
    • /
    • pp.24-29
    • /
    • 2013
  • Background: The incidence of blow out fractures is increasing and the techniques of diagnosis and treatment have been recently evolving. Despite its clinical significance, there has been no study on orbital inferiomedial blow out fractures. Therefore, this study was designed to investigate the clinical significance of treatment of orbital inferiomedial blow out fractures. Methods: A retrospective review of fifty-seven patients who could be followed up for at least 1 year after surgical reconstruction of pure inferiomedial blow out fracture was undertaken. The transconjunctival approach was performed in all cases. The onlay technique was used in 32 patients and the inlay/sheet method was used in 25 patients. We evaluated the clinical outcomes using the chi-square test. Results: In the group using the onlay technique, postoperative diplopia and enophthalmos were observed in 14 cases and 3 cases, respectively. Of these, 5 cases and 3 cases lasted for more than 6 months, respectively. In the group using the inlay/sheet method, postoperative diplopia was observed in 9 cases, but there were no cases of enophthalmos. Among the 9 diplopia cases, 4 lasted for more than 6 months. Conclusion: Postoperative diplopia and enophthalmos were increased after treatment of inferiomedial blow out fractures compared to isolated medial (0.6%, 0.3%) or inferior (1.8%, 0.6%) blow out fractures. Therefore, careful dissection is necessary not to injure the inferior oblique muscle to decrease the incidence of postoperative diplopia. Moreover, the inlay/sheet method is an effective option for reconstruction of inferiomedial blow out fractures.

THE CAUCHY PROBLEM FOR AN INTEGRABLE GENERALIZED CAMASSA-HOLM EQUATION WITH CUBIC NONLINEARITY

  • Liu, Bin;Zhang, Lei
    • 대한수학회보
    • /
    • 제55권1호
    • /
    • pp.267-296
    • /
    • 2018
  • This paper studies the Cauchy problem and blow-up phenomena for a new generalized Camassa-Holm equation with cubic nonlinearity in the nonhomogeneous Besov spaces. First, by means of the Littlewood-Paley decomposition theory, we investigate the local well-posedness of the equation in $B^s_{p,r}$ with s > $max\{{\frac{1}{p}},\;{\frac{1}{2}},\;1-{\frac{1}{p}}\},\;p,\;r{\in}[0,{\infty}]$. Second, we prove that the equation is locally well-posed in $B^s_{2,r}$ with the critical index $s={\frac{1}{2}}$ by virtue of the logarithmic interpolation inequality and the Osgood's Lemma, and it is shown that the data-to-solution mapping is $H{\ddot{o}}lder$ continuous. Finally, we derive two kinds of blow-up criteria for the strong solution by using induction and the conservative property of m along the characteristics.

안와 파열 골절 치료 시 삽입물 종류에 따른 후유증 비교 (Comparison of Sequelae According to the Types of Implants in Blow-Out Fracture)

  • 김태곤;임종효;이준호;김용하
    • 대한두개안면성형외과학회지
    • /
    • 제10권1호
    • /
    • pp.23-28
    • /
    • 2009
  • Purpose: Blow out fracture can present tenderness, swelling, enophthalmos, extraoccular muscle limitation, paresthesia, diplopia according to severity of injury, so reconstruction of blow out fracture is important. Orbital soft tissue should be in orbit and defected orbital wall should be corrected by autologus tissue or alloplastic implants. Every implants have their merits and faults, every implants are used various. This study was designed to compare the sequelae of blow-out fracture repair using the alloplastic implants: micro-titanium mesh(Micro Dynamic titanium $mesh^{(R)}$, Leibinger, Germany), porous polyethylene ($Medpor^{(R)}$, Porex, USA), absorbable mesh plate(Biosorb $FX^{(R)}$ . Bionx Implants Ltd, Finland). Methods: Between January 2006 and April 2008, 52 patients were included in a retrospective study analysing the outcome of corrected inferior orbital wall fracture with various kind of implants. Implants were inserted through subciliary incision. Twenty patients were operated with micro-titanium mesh, fourteen patients with porous polyethylene and eighteen patients with absorbable mesh plate. In comparative category, enophthalmos, diplopia, range of motion of extraoccular muscle, inferior orbital nerve injury were more on frequently statistically in patients. Results: Fourteen of 18 patients underwent surgical repair to improve diplopia, 11 of 17 patients to improve parasthesia, 11 of 15 patients to improve enophthalmos, 8 of 9 patients to improve extraoccular muscle limitation. Duration of follow-up time ranged from 6 months to 12 months(mean, 7.4 months). There was no statistic difference of sequelae between micro titanium mesh and porous polyethylene and absorbable mesh plate in blowout fracture, inferior wall. Conclusion: There is no difference of sequelae between micro-titanium mesh, porous polyethylene and absorbable mesh plate in blow-out fracture, inferior wall. The other factors such as defect size, location, surgeon's technique, may influence the outcome of blow-out fracture repair.