• 제목/요약/키워드: Blood pressure monitoring

검색결과 193건 처리시간 0.027초

모듈형 환자 모니터의 개발 (Development of a Module-Based Bedside Monitor for Patient Monitoring)

  • 우응제;박승훈
    • 대한의용생체공학회:의공학회지
    • /
    • 제18권2호
    • /
    • pp.133-146
    • /
    • 1997
  • In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases, each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO with plethysmograph.raph.

  • PDF

Non-invasive Transcutaneous pCO2 Gas Monitoring System for Arterial Blood Gas Analysis

  • Bang, Hyang-Yi;Kang, Byoung-Ho;Eum, Nyeon-Sik;Kang, Shin-Won
    • 센서학회지
    • /
    • 제20권5호
    • /
    • pp.311-316
    • /
    • 2011
  • Monitoring the carbon dioxide concentration in arterial blood is vital for the evaluation and prevention of pulmonary disease. Yet, domestic pure arterial blood carbon dioxide sensor technologies are not being developed, instead all sensors are imported. In this paper, we develop a real time monitoring system for arterial blood partial pressure of carbon dioxide($pCO_2$) gas from the wrist by using a carbon micro-heater. The micro-heater was fabricated with a thickness of 0.3 ${\mu}m$ in order to collect the carbon dioxide under the skin. The micro-heater has been designed to perform temperature compensation in order to prevent damage to the skin. Two clinical trials of the system were undertaken. As a result, we demonstrated that a portable, transcutaneous carbon dioxide analysis($TcpCO_2$) device produced domestically is possible. In addition, this system reduced the analysis time significantly. Carbon films could reduce the unit price of these sensors by replacing the gold film used in foreign models. Also, we developed a real time monitoring system which can be used with optical biosensors for medical diagnostics as well as gas sensors for environmental monitoring.

우황청심원이 정상인의 뇌혈류 및 혈압에 미치는 영향 (Effects of Uwhangchungsimwon(牛黃淸心元) on Cerebral Blood Flow and Systemic Blood Pressure in Humans)

  • 김영석
    • 대한한방내과학회지
    • /
    • 제20권1호
    • /
    • pp.222-231
    • /
    • 1999
  • Uwhangchungsimwon(UC) has been used in the treatment of a wide variety of conditions including stroke, hypertension, arteriosclerosis, autonomic imbalance, mental instablity, etc in Korean traditional hospitals, In particular it is often initialy chosen for emergency care of acute stroke. The aim of this study was to evaluate the effect of UC on cerebral hemodynamics. Using transcranial Doppler ultrasound, we studied changes of mean flow velocity and pulsatility index(PI) of middle cerebral arteries (MCAs) from 11 health young volunteers who were administrated with 1 pill UC and 11 health controls who were not. We obtained hypercapnia with breath-holding and evaluated cerebrovascular reactivity with breath-holding index(BHI). Systolic blood pressure, diastolic blood pressure, and heart rate were measured using ambulatory blood pressure monitoring(ABPM). In UC administration group, the evaluation was performed during basal condition. and repeated at 20, 40, and 60 min after administration. In controls, the evaluation was performed at corresponding time intervals. Mean flow velocity in middle cerebral artery, systolic blood pressure, diastolic blood pressure, and heart rate did not change during the observation period and were not different between these two groups. However, administration of UC was associated with decreases in PI by $3.6{\sim}12.4%$ in BHI by $17.9{\sim}24.8%$ compared with pre-administration period. Decreases in PI and BHI with UC were significantly different compared with control group (p<0.05). These results indicate that UC decreases PI and BHI in cerebral artery, which is due to a dilation of cerebral resistance vessels.

  • PDF

스마트 폰 기반 3D 프린팅 칩을 이용한 적혈구 변형성 측정 (Measurement of RBC (red blood cell) deformability using 3D Printed Chip combined with Smartphone)

  • 이수환;홍현지;염은섭;송재민
    • 한국가시화정보학회지
    • /
    • 제18권3호
    • /
    • pp.103-108
    • /
    • 2020
  • RBC (red blood cell) deformability is one of factors inducing blood shear thinning effect. Reduction of RBC deformability increases blood viscosity in high shear region. In this study, 3D printed chip with proper distribution of wall shear rate (WSR) was proposed to measure RBC deformability of blood samples. To fabricate 3D printed chip, the design of 3D printed chip determined through numerical simulation was modified based on the resolution of the 3D printer. For the estimation of pressure drop in the 3D printed chip, two bypass outlets with low and high WSR are exposed to atmospheric pressure through the needles. By positioning the outlet of needles in the gravity direction, the formation of droplets at bypass outlets can be captured by smartphone. Through image processing and fast Fourier transform (FFT) analysis, the frequency of droplet formation was analyzed. Since the frequency of droplet formation is related with the pressure at bypass, high pressure drop caused by reduction of RBC deformability can be estimated by monitoring the formation of blood droplets using the smartphone.

혈압 측정을 위한 외팔보형 접촉힘 센서 어레이 (A Cantilever Type Contact Force Sensor Array for Blood Pressure Measurement)

  • 이병렬;정진우;전국진
    • 센서학회지
    • /
    • 제21권2호
    • /
    • pp.121-126
    • /
    • 2012
  • Piezoresistive type contact force sensor array is fabricated by (111) Silicon bulk micromachining for continuous blood pressure monitoring. Length and width of the unit sensor structure is $200{\mu}m$ and $190{\mu}m$, respectively. The gap between sensing elements is only $10{\mu}m$. To achieve wafer level packaging, the sensor structure is capped by PDMS soft cap using wafer molding and bonding process with $10{\mu}m$ alignment precision. The resistance change over contact force was measured to verify the feasibility of the proposed sensor scheme. The maximum measurement range and resolution is 900 mm Hg and 0.57 mm Hg, respectively.

Disagreement between direct and indirect blood pressure measurements obtained from minipigs

  • Lee, Won-Jae;Park, Lisa Soyeon
    • 대한수의학회지
    • /
    • 제58권3호
    • /
    • pp.131-136
    • /
    • 2018
  • Blood pressure (BP) measurement plays a pivotal role in veterinary medicine for diagnosing cardiovascular disorders and monitoring anesthesia of animals. Although indirect BP measurement has been widely applied to monitor BP because of its convenience and non-invasiveness, it is still unclear whether indirect BP measurement is compatible with direct BP measurement in minipigs. In addition, the effect of animal posture during BP measurement is not well understood in minipigs despite its importance to cardiovascular performance. Therefore, both systolic and diastolic arterial BPs in minipigs were measured via femoral artery catheterization for direct BP measurement and using a compressive cuff as an indirect BP measurement under the dorsal or right lateral recumbent postures. Numerical values were processed by the Bland-Altman method to calculate the bias ${\pm}$ SD and the limits of agreement (LOA). In accordance with the American College of Veterinary Internal Medicine guidelines, the results between direct and indirect BP measurements were determined as apparent disagreements in both systolic and diastolic arterial BPs under all postures because of large bias ${\pm}$ SD and wide LOA. The results of the present will help prevent misinterpretation of the anesthetized patient's condition during monitoring of BP by indirect measurement.

간호사의 야간교대근무로 인한 혈압의 일중 변동 양상 (The Effect of Shift Work on the Diurnal Rhythm of Blood Pressure in Nurses)

  • 이안생;이상재;김남호
    • 한국직업건강간호학회지
    • /
    • 제18권1호
    • /
    • pp.14-21
    • /
    • 2009
  • Purpose: This study was performed to investigate the effect of shift work on diurnal blood pressure (BP) pattern in nurses. Method: We studied 20 healthy nurses engaged in 3 shift work. 24-hour ambulatory BP monitoring was performed to each nurse two times during the day and night shift. Five nurses were excluded because of inadequate BP measurement. Results: All subjects were female. The mean age was 27.4 years (range: 23-33 years) and mean body mass index was 19.7 Kg/$m^2$ (range: 18.0-21.2 Kg/$m^2$). The changes of systolic BP ($17.8{\pm}9.1$ vs. $13.2{\pm}4.7%$, p=0.031), diastolic BP ($22.3{\pm}8.7$ vs. $17.3{\pm}9.0%$, p=0.061), and heart rate ($25.2{\pm}5.2$ vs. $12.5{\pm}8.7%$, p=0.001) during the sleeping period were decreased after a night shift compared with day shift. The non-dipper group significantly increased from 20% to 40% after a night shift (p=0.018). Conclusion: Working night shift is significantly associated with non-dipper status in nurses.

  • PDF

개인 의료기관에 내원한 고혈압 및 당뇨병환자에게 실시한 건강교육이 치료 순응도에 미치는 영향 (The Effects of Health Education on Treatment Compliance of Patients with High Blood Pressure and Diabetes in Private Clinics)

  • 이태용;김광환
    • 한국산학기술학회논문지
    • /
    • 제10권2호
    • /
    • pp.425-431
    • /
    • 2009
  • 고혈압과 당뇨병으로 치료를 받고 있는 환자들을 대상으로 일정한 보건교육이 치료순응도에 미치는 영향을 파악하기 위하여 2007년 9월부터 2008년 2월까지 대전시에 내과 및 가정의로 개업하고 있는 의교기관중 본 연구의 취지에 동의한 의료기관에 내원한 환자 1,213명에 대하여 2회 설문조사한 결과는 다음과 같다. 조사대상자 1,213명 중 고혈압만 있는 환자가 49.2%, 당뇨만 있는 환자는 26.3%, 고혈압과 당뇨병을 동반하고 있는 환자는 22.4%이었으며, 성별에는 차이가 없었다. 개원의들이 생각하는 환자들의 자신의 질병에 대한 관리태도는 소극적으로 한다가 56.7%로 가장 높았고, 비약물적 치료방법도 88.9%에서 병행하고 있었다. 본 연구에서 실시한 교육의 효과가 있다고 생각하는 사람이 63.7%로 높았으며, 생활양식으로 운동, 음식습관의 변화, 음주의 변화가 있었지만 낮았고, 체중과 흡연은 변화가 거의 없었다.

환자모니터링시스템의 개발 : 전체구조 및 기본사양 (Development of a Patient Monitoring System Overall Architecture and Specifications)

  • 우응제;박승훈
    • 대한의용생체공학회:의공학회지
    • /
    • 제18권1호
    • /
    • pp.17-24
    • /
    • 1997
  • We have developed a patient monitoring system including module-based bedside monitors, interbed network, central stations, clinical workstations, and DB servers. A bedside monitor with a color LCD can accommodate up to 3 module cases and 21 different modules. Six different physiological parameters of ECG, respiration, invasive blood pressure, noninvasive blood pressure, body temperature, and arterial pulse oximetry with plethysmoyaph are provided as parameter modules. In a single bedside monitor, modules and a module controller communicate with IMbps data rate through an intrabed network based on RS-485 and HDU protocol. At the same time, it communicates with other bedside monitors and central stations through interbed network based on 1 OMbps Ethernet and TCP/IP protocol. Central stations using 20" color CRT monitors can be connected with many bedside monitors and they display 18 channels of waveforms simultaneously. Clinical workstations are used mainly for the review of patient datE In order to accommodate more advanced data management capabilities such as 24-hour full disclosure, we have developed a relational database server dedicated to the patient monitoring system. Software for bedside monitor, central station, and clinical workstation fully utilizes graphical user interface techniques and all functions are controlled by a rotate/push button on the bedside monitor arid a mouse on the central station and clinical workstation. The entire system satisfies the requirements of AAMI and ANSI standards in terms of electrical safety and performances.nces.

  • PDF

경구기관삽관법과 경비기관삽관법의 심혈관계 영향에 대한 비교 (A Comparison of Cardiovascular Effects between Orotracheal Intubation and Nasotracheal Intubation)

  • 김동옥;최영규
    • 대한치과마취과학회지
    • /
    • 제1권1호
    • /
    • pp.10-15
    • /
    • 2001
  • Background: This prospective study was designed to compare the cardiovascular response to endotracheal insertion of either an orotracheal tube or a nasotracheal tube Methods: 120 ASA physical status I and II surgical patients requiring general anesthesia and tracheal intubation were studied and assigned to two groups: orotracheal intubation group (n = 60) and nasotracheal intubation group (n = 60). Patients were premedicated with midazolam 0.05 mg/kg and glycopyrrolate 0.005 mg/kg intramuscularly and anesthesia was induced with thiopental sodium 5 mg/kg and succinylcholine 0.1 mg/kg intravenously. Systolic blood pressure (SBP), diastolic blood pressure (DBP). mean arterial pressure (MAP) and heart rate (HR) were assessed noninvasively before induction of anesthesia and immediately after intubation, 1 min, 2 min, 3 min, and 5 min after intubation. Results: Cardiovascular responses such as SBP, DBP, MAP and HR were similar for both techniques and no significant differences between two groups were observed until 5 min after intubation. Conclusions: In healthy ASA I and II patients with normal blood pressure, induction doses of thiopental sodium 5 mg/kg and succinylcholine 0.1 mg/kg didn't attenuated the cardiovascular response to laryngoscopy and tracheal intubation. Insertion of an endotracheal tube may be the most invasive stimulus during intubation procedures. (JKDSA 2001; 1: 10-15)

  • PDF