• Title/Summary/Keyword: Blood pressure monitor

Search Result 106, Processing Time 0.028 seconds

Implementation of sensor network based health care system for diabetes patient

  • Kim, Jeong-Won
    • Journal of information and communication convergence engineering
    • /
    • v.6 no.4
    • /
    • pp.454-458
    • /
    • 2008
  • It can improve human being's life quality that all people can have more convenient medical service under pervasive computing environment. For a pervasive health care application for diabetes patient, we've implemented a health care system, which is composed of three parts. Various sensors monitor both outer and inner environment of human such as temperature, blood pressure, pulse, and glycemic index, etc. These sensors form zigbee based sensor network. And medical information server accumulates sensing values and performs back-end processing. To simply transfer these sensing values to a medical team is a low level's medical service. So, we've designed a new service model based on back propagation neural network for more improved medical service. Our experiments show that a proposed healthcare system can give high level's medical service because it can recognize human's context more concretely.

An U-Healthcare Implementation for Diabetes Patient based on Context Awareness

  • Kim, Jeong-Won
    • Journal of information and communication convergence engineering
    • /
    • v.7 no.3
    • /
    • pp.412-417
    • /
    • 2009
  • With ubiquitous computing aid, it can improve human being's life quality if all people have more convenient medical service under pervasive computing environment. In this paper, for a pervasive health care application for diabetes patient, we've implemented a health care system, which is composed of three parts. Various sensors monitor both outer and inner environment of human such as temperature, blood pressure, pulse, and glycemic index, etc. These sensors form zigbee-based sensor network. And as a backend, medical information server accumulates sensing data and performs back-end processing. To simply transfer these sensing values to a medical team may be a low level's medical service. So, we've designed a model with context awareness for more improved medical service which is based on ART(adaptive resonance theory) neural network. Our experiments show that a proposed healthcare system can provide improved medical service because it can recognize current context of patient more concretely.

Development of ECS-NIBP-$SpO_2$ Patient Monitoring System (ECG-NIBP-$SpO_2$ 환자감시장치 개발)

  • Kim, N.H.;Shin, W.H.;Lee, G.K.;Ra, S.W.;Kim, G.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.129-130
    • /
    • 1998
  • In this paper, We designed the ECG-NIBP-$SpO_2$ patient monitor. This production can measure Electrocardiograph, Heart Rate, Noninvasive Blood Pressure, and Oxygen Saturation for Noninvasive Mehod and can display each information. These informations were implemented by the electrodes of ECG part, the cuff of NIBP module and the finger probe with light sensor of $SpO_2$ without injection of needle or catheter. In addition, We developed a new analysis algorithm and measurement technique for NIBP and $SpO_2$ to observe patient's conditions correctly.

  • PDF

The Effect of Walking Exercise Program on Cardiorespiratory Function and Flexibility in Elderly Women (걷기운동프로그램이 노인여성의 심폐기능, 유연성에 미치는 효과)

  • 신윤희;최영희
    • Journal of Korean Academy of Nursing
    • /
    • v.26 no.2
    • /
    • pp.372-386
    • /
    • 1996
  • Recently, the ratio of elderly in the population are fast growing due to socio-economical development and the better medical service. Proportionally, the health problems in elderly are increasing, too. Medical professionals must try so that the elderly have the better life through health promotion and disease prevention as well as disease treatment. This study evaluated the effect of walking exercise program on the cardiorespiratory function and the flexibility in the elderly women. The design of research was one group pretest-posttest design. The subjects were eleven elderly women over sixty years old to live in K-city, Kyonggi-do. The type of exercise was walking, which was the most popular exercise in questionnaire. The exercise intensity was 40%∼60% of the target heart-rate by Karvonen's method and maintained by the heart-rate monitor. The exercise period was five weeks and the exercise frequency was three times per week. The exercise duration was forty minutes at first and gradually increased up to an hour. In order to evaluate the effect of walking exercise, we measured VO/sub₂ max, resting heart -rate, systolic/diastolic blood pressure, FVC, FEV/sub₁, the flexibility before and after the five week's exercise program. The data are analyzed by the paired t-test and Wilcoxon signed rank test using SAS package. The results are as follows : 1) The hypothesis that cardiorespiratory function will be improved was partly supported. In VO/sub₂ max(p=0.0001), resting heart-rate(p=0.0030), systolic/diastolic blood-pressure(p=0.0387/ p=0.0024), there was significant difference. FVC and FEV/sub₁ were increased after the exercise, but there were no significant difference. 2) The hypothesis that the flexibility will be improved was supported. There was significant difference in the flexibility(p=0.0140). As the further study, it is necessary to reevaluate the effect with more refined design. We also need to try meta-analysis about the results of previous studies obtained in the experimental setting and compare our result obtained in the field setting with them.

  • PDF

Postprandial Blood Pressure in Hypertensive and Normotensive Elderly and Young Adult Subjects (고혈압노인과 정상혈압노인 및 청년의 식후혈압 변화 비교)

  • Son, Jung Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.12
    • /
    • pp.5849-5859
    • /
    • 2012
  • The aim of this study was to find out the impact of age and hypertensive status on postprandial hypotension(PPH). Twenty-six hypertensive elderly ($77.7{\pm}7.2$ years old), twenty-five normotensive elderly ($80.2{\pm}6.8$ years old) and twenty-six young adults ($20.0{\pm}1.5$ years old) took part in the study. The blood pressure (BP) and heart rates (HR) were measured every 15 minutes, from 30 minutes before a meal to 90 minute after a meal in sitting position, using an ambulatory blood pressure monitor. In the hypertensive group, postprandial reduction in systolic BP continued from 30minutes to 90minutes. The reductuion rate of systolic BP of hypertensive elderly group was significantly greater than other groups (p<.05). However, there were no significant differences in trend of HR change between the groups (p=.082). The incidence of PPH was significantly higher in the hypertensives than other groups (73.1% vs 24% vs 0%, respectively, p=.001). In conclusion, age and hypertensive status had a significant impact on PPH. Elderly persons require more intensive BP monitoring and nursing intervention.

Respiratory Air Flow Transducer Applicable to Cardiopulmonary Resuscitation Procedure (인공심폐소생술에 활용 가능한 호흡기류센서)

  • Kim, Kyung-Ah;Lee, In-Kwang;Lee, You-Mi;Yu, Hee;Kim, Young-Il;Han, Sang-Hyun;Cha, Eun-Jong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.6
    • /
    • pp.833-839
    • /
    • 2013
  • Cardiopulmonary resuscitation (CPR) is performed by thoracic compression and artificial ventilation for the patient under emergent situation to maintain at least the minimum level of respiration and blood circulation for life survival. Good quality CPR requires monitoring respiration, however, traditional respiratory air flow transducers cannot be used because the transducer elements are facing the whole area perpendicular to the flow axis. The present study developed a new air flow transducer conveniently applicable to CPR. Specially designed "sensing rod" samples the air velocity at 3 different locations of the flow cross-section, then transforms into average dynamic pressure by the Bernoulli's law. The symmetric structure of the sensing holes of the sensing rod enables bi-directional measurement simply by taking the difference in pressure by a commercial differential pressure transducer. Both inspiratory and expiratory flows were obtained with symmetric measurement characteristics. Quadratic curve fitting provided excellent calibration formula with a correlation coefficient>0.999 (P<0.0001) and the mean relative error<1%. The present results can be usefully applied to accurately monitor the air flow rate during CPR.

The Development of the Medical Information's Transmission System Using the Bluetooth (블루투스 통신을 이용한 의료정보 전송 시스템의 개발)

  • Hong, Seung-Beom;Jie, Min-Seok
    • Journal of Advanced Navigation Technology
    • /
    • v.13 no.5
    • /
    • pp.787-792
    • /
    • 2009
  • A number of very promising applications such as health monitoring and U-Health of ubiquitous techniques has attracted interest in recent years. Because it can observes the condition of patient from long distance using the equipment which combines with radio communication and medical monitoring system. If it is at emergency situation, it can disposes the condition of the patient. In this paper, we propose the new data format and the transmission communication system of combination medical information with the bluetooth. And we produce the on-board system which transmits the medical information. This system integrated the blood pressure and glucose monitor of personal medical equipment, and the medical information which obtained from on-board system acquires through the gateway with the bluetooth. Medical information is transmitted to the tele-monitor server by the wireline network. We evaluated the proposed system under the laboratory environment and confirmed the excellent performance of transmission of the medical information.

  • PDF

Development of Oriental-Western Fusion Patient Monitor by Using the Clip-type Pulsimeter Equipped with a Hall Sensor, the Electrocardiograph, and the Photoplethysmograph (홀센서 집게형 맥진기와 심전도-용적맥파계를 이용한 한양방 융합용 환자감시장치 개발연구)

  • Lee, Dae-Hui;Hong, Yu-Sik;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.4
    • /
    • pp.135-143
    • /
    • 2013
  • The clip-type pulsimeter equipped with a Hall sensor has a permanent magnet attached in the "Chwan" position to the center of a radial artery. The clip-type pulsimeter is composed of a hardware system measuring voltage signals. These electrical bio-signals display pulse rate, non-invasive blood pressure, respiratory rate, pulse wave velocity (PWV), and spatial pulse wave velocity (SPWV) simultaneously measured by using the radial artery pulsimeter, the electrocardiograph (ECG), and the photoplethysmograph (PPG). The findings of this research may be useful for developing a oriental-western biomedical signal storage device, that is, the new and fusion patient monitor, for a U-health-care system.

A STUDY ON IMPLEMENTATION OF OUTWARD AGING AND HEALTH-STATE MONITORING SYSTEM BASED ON IMAGE PROCESSING (영상처리에 기반한 노인 대상 외양적 노화 및 건강 상태 모니터링 시스템에 관한 연구)

  • Hwang, Kun-Su;Kil, Se-Kee;Shen, Dong-Fan;Min, Hong-Ki;Lee, Eung-Hyuk;Hong, Seung-Hong
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.881-882
    • /
    • 2006
  • According as society looks graying trend gradually, more shaped system that can achieve measuring health-state of old people more harmoniously construction required in field of old people's welfare and medical treatment. Health-state is measured by two methods of contact and non-contact. The first, for example measurement of blood pressure or electrocardiogram, requires that measuring equipments are attached on human body but the second, for example X-Ray or MRI, is not. But both of methods are have some of defect, for example attaching equipments, needing of the special equipments or the necessary time, etc. Therefore desirable method of monitoring system must have minimum interrupt about daily life. This study suggest the system that can monitor the user, especially old people's outward aging and health-state by use the PAN TILTER and CCD camera.

  • PDF

A novel low-profile flow sensor for monitoring of hemodynamics in cerebral aneurysm

  • Chen, Yanfei;Jankowitz, Brian T.;Cho, Sung Kwon;Yeo, Woon-Hong;Chun, Youngjae
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • v.2 no.2
    • /
    • pp.71-84
    • /
    • 2015
  • A low-profile flow sensor has been designed, fabricated, and characterized to demonstrate the feasibility for monitoring hemodynamics in cerebral aneurysm. The prototype device is composed of three micro-membranes ($500-{\mu}m$-thick polyurethane film with $6-{\mu}m$-thick layers of nitinol above and below). A novel super-hydrophilic surface treatment offers excellent hemocompatibility for the thin nitinol electrode. A computational study of the deformable mechanics optimizes the design of the flow sensor and the analysis of computational fluid dynamics estimates the flow and pressure profiles within the simulated aneurysm sac. Experimental studies demonstrate the feasibility of the device to monitor intra-aneurysmal hemodynamics in a blood vessel. The mechanical compression test shows the linear relationship between the applied force and the measured capacitance change. Analytical calculation of the resonant frequency shift due to the compression force agrees well with the experimental results. The results have the potential to address important unmet needs in wireless monitoring of intra-aneurysm hemodynamic quiescence.