• Title/Summary/Keyword: Blood depth

Search Result 205, Processing Time 0.028 seconds

Use of ADMSTM during sedation for dental treatment of an intellectually disabled patient: a case report

  • Chi, Seong In;Kim, Hyun Jeong;Seo, Kwang-Suk;Yang, Martin;Chang, Juhea
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.16 no.3
    • /
    • pp.217-222
    • /
    • 2016
  • Dental treatment is often performed under general anesthesia or sedation when an intellectually disabled patient has a heightened fear of treatment or has difficulty cooperating. When it is impossible to control the patient due to the severity of intellectual disability, conscious sedation is not a viable option, and only deep sedation should be performed. Deep sedation is usually achieved by propofol infusion using the target controlled infusion (TCI) system, with deep sedation being achieved at a slightly lower concentration of propofol in disabled patients. In such cases, anesthesia depth monitoring using EEG, as with a Bispectral Index (BIS) monitor, can enable dental treatment under appropriate sedation depth. In the present case, we performed deep sedation for dental treatment on a 27-year-old female patient with mental retardation and severe dental phobia. During sedation, we used BIS and a newly developed Anesthetic Depth Monitor for Sedation (ADMS$^{TM}$), in addition to electrocardiography, pulse oximetry, blood pressure monitoring, and capnometry for patient safety. Oxygen was administered via nasal prong to prevent hypoxemia during sedation. The BIS and ADMS$^{TM}$ values were maintained at approximately 70, and dental treatment was successfully performed in approximately 30 min.

Effect of Next-Generation Exome Sequencing Depth for Discovery of Diagnostic Variants

  • Kim, Kyung;Seong, Moon-Woo;Chung, Won-Hyong;Park, Sung Sup;Leem, Sangseob;Park, Won;Kim, Jihyun;Lee, KiYoung;Park, Rae Woong;Kim, Namshin
    • Genomics & Informatics
    • /
    • v.13 no.2
    • /
    • pp.31-39
    • /
    • 2015
  • Sequencing depth, which is directly related to the cost and time required for the generation, processing, and maintenance of next-generation sequencing data, is an important factor in the practical utilization of such data in clinical fields. Unfortunately, identifying an exome sequencing depth adequate for clinical use is a challenge that has not been addressed extensively. Here, we investigate the effect of exome sequencing depth on the discovery of sequence variants for clinical use. Toward this, we sequenced ten germ-line blood samples from breast cancer patients on the Illumina platform GAII(x) at a high depth of ${\sim}200{\times}$. We observed that most function-related diverse variants in the human exonic regions could be detected at a sequencing depth of $120{\times}$. Furthermore, investigation using a diagnostic gene set showed that the number of clinical variants identified using exome sequencing reached a plateau at an average sequencing depth of about $120{\times}$. Moreover, the phenomena were consistent across the breast cancer samples.

Estimation on the Depth of Anesthesia using Linear and Nonlinear Analysis of HRV (HRV 신호의 선형 및 비선형 분석을 이용한 마취심도 평가)

  • Ye, Soo-Young;Baik, Seong-Wan;Kim, Hye-Jin;Kim, Tae-Kyun;Jeon, Gye-Rok
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.1
    • /
    • pp.76-85
    • /
    • 2010
  • In general, anesthetic depth is evaluated by experience of anesthesiologist based on the changes of blood pressure and pulse rate. So it is difficult to guarantee the accuracy in evaluation of anesthetic depth. The efforts to develop the objective index for evaluation of anesthetic depth were continued but there was few progression in this area. Heart rate variability provides much information of autonomic activity of cardiovascular system and almost all anesthetics depress the autonomic activity. Novel monitoring system which can simply and exactly analyze the autonomic activity of cardiovascular system will provide important information for evaluation of anesthetic depth. We investigated the anesthetic depth as following 7 stages. These are pre-anesthesia, induction, skin incision, before extubation, after extubation, Post-anesthesia. In this study, temporal, frequency and chaos analysis method were used to analyze the HRV time series from electrocardiogram signal. There were NN10-NN50, mean, SDNN and RMS parameter in the temporal method. In the frequency method, there are LF and HF and LF/HF ratio, 1/f noise, alphal and alpha2 of DFA analysis parameter. In the chaos analysis, there are CD, entropy and LPE. Chaos analysis method was valuable to estimate the anesthetic depth compared with temporal and frequency method. Because human body was involved the choastic character.

Single use Automatic Lancet to Minimize Pain During Skin Puncture (피부관통시 통증을 최소화하는 일회용 자동 모세혈액 채취기구)

  • 김현식;김경아;전명희;김태임;정용현;이태수;차은종
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.4
    • /
    • pp.323-327
    • /
    • 2002
  • Chronic diabetic patients need to sample capillary blood for monitoring and controlling the blood sugar level. Frequent sampling requires to minimize pain during skin puncture. The present study developed mechanisms to minimize pain with effective sampling procedure. which consisted of tapered spring, guiding tunnel, and 30G needle Penetration depth was limited to within 2mm for pain reduction as well as for safety. Simple no-reuse mechanism also prevented the cross-patient and secondary infection possibility. Clinical experiments demonstrated the best convenience and safety with minimal pain in the diabetes, normal, and nursing students groups. Sing1e blood sampling was enough for successful blood sugar test by portable analyzer. The present sing1e use auto-lancet should be of great convenience in frequent capillary blood sampling for the diabetes.

Neurologic Study of SP6(Sanyinjiao, 三陰交) Acupuncture on Bladder parasympathetic Nerve, Tibial Nerve and Blood Pressure in Rats (삼음교(三陰交) 침자(鍼刺)가 부교감신경(副交感神經)의 방광분지(膀胱分枝), 경골신경(脛骨神經) 및 혈압(血壓)에 미치는 영향(影響))

  • Park, Chun-Ha;Yoon, Yeo-Choong;Na, Chang-Su
    • Journal of Acupuncture Research
    • /
    • v.19 no.1
    • /
    • pp.175-188
    • /
    • 2002
  • Objective : The effects of SP6(Sanyinjiao, 三陰交) acupuncture stimulation on bladder parasympathetic nerve activity (PNA), tibial nerve activity (TNA) as well as blood pressure were examined in anesthetized rats and the results are as follows. Methods : The parasympathetic nerve leading to the bladder was exposed retroperitoneally, and the tibial nerve in the hindlimb was exposed through inguinal area. PNA and TNA were recorded using a bipolar platinum-iridium wire electrode and it was connected to preamplifier. Blood pressure was measured using cannula that was inserted into femoral artery and was recorded with blood pressure sensor that is connected with transducer amplifier. The mean value of all parameters measured for 30 seconds before the stimulation was expressed as 100%. An acupuncture needle was inserted into the SP6 region to a depth of 4 mm. Results : Under intact state (IS), acupuncture stimulation for 120 seconds induced significant increase of PNA which was accompanied with decrease of blood pressure. At the same time, TNA showed temporary increase only with acupuncture stimulation. In 4 mg/kg of naloxone-administrated state (NAS), significant decrease of PNA was seen and it was accompanied with increase of blood pressure. TNA also showed temporary increase only with acupuncture stimulation under the NAS just like the IS. Conclusion : consider that SP6(Sanyinjiao, 三陰交) acupuncture stimulation activated parasympathetic nerve and caused vasodilation to lead into the diuresis, but naloxone reversed the effect of acupuncture for antidiuresis.

  • PDF

A Study of Intracranial Hemodynamic Change with Aging (노화에 따른 두개내 혈류의 혈류 동력학적 변화에 관한 연구)

  • Kim Jong-Soon;Kim Byung-Jo;Bae Sung-Soo
    • The Journal of Korean Physical Therapy
    • /
    • v.14 no.4
    • /
    • pp.119-130
    • /
    • 2002
  • The purpose of this study was to evaluate hemodynamics of intracranial blood flow for obtain clinically useful reference values and assess cerebral hemodynamics change with aging. 81 normal Korean subjects(age, 14$\thicksim\∼\thicksim$70 years) examined who han no history of neurologic disease and the subjects divided into group A(age, 14$\∼$39 years), group B(age, 40$\∼$59 years) and group C(age, 60$\∼$70 years). Transcranial doppler was use for measured the maximum velocity(Vmax), mean velocity(Vmean), pulsatility index(PI), resistive index(RI), stenosis index(SI) and depth of sample volume. Vmax was 99.1 1cm/s, Vmean was 63.57cm/s, PI was 0.85, RI was 0.56, SI was 31.94 and depth of sample volume was 52.35 in middle cerebral artery. Vmax was 85.54cm/s, Vmean was 52.52cm/s, PI was 0.82, RI was 0.55, SI was 34.48 and depth of sample volume was 73.62 in anterior cerebral artery. Vmax was 75.45cm/s, Vmean was 45.60cm/s, PI was 0.82, RI was 0.58, SI was 36.14 and depth of sample volume was 62.35 in posterior cerebral artery. Vmax was 70.44cm/s, Vmean was 47.07cm/s, PI was 0.87, RI was 0.58, SI was 29.83 and depth of sample volume was 75.23 in basilar artery Vmax was 63.92, Vmean was 42.42, PI was 0.89, RI was 0.58, SI was 29.89 and depth of sample volume was 66.65 in vertebral artery. Vmax and Vmean was significantly decreased with increasing age in middle cerebral artery, anterior cerebral artery, posterior cerebral artery, basilar artery and vertebral artery And PI and RI was significantly increased with increasing age in basilar artery and vertebral artery. And I suggest that transcranial doppler sonography can be used as one of useful clinical tool for detection of cerebral hemodynamics.

  • PDF

Developement of Efficient Algorithm to Eliminate Aliasing of Ultrasonic Pulsed Wave Doppler Signal (초음파 Pulsed Wave 도플러 신호의 Aliasing 제거를 위한 효율적인 알고리즘 개발)

  • Kim, G.D.;Hwang, J.S.;Ahn, Y.B.;Song, T.K.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.213-214
    • /
    • 1998
  • The important role of the ultrasonic Doppler system in the modem clinical medicine is to provide the clinical information of the vascular system. The ultrasonic pulsed wave(PW) Doppler system, a kind of the ultrasound Doppler system, is more available than the ultrasonic continuous wave(CW) Doppler system because it can evaluate the velocity and the direction of blood flow as well as the depth of vessel. However, the ultrasonic PW Doppler system has the disadvantage that the range of evaluating velocity of blood flow is limited(Nyquist limit). In order to solve this limit, we propose the algorithm for eliminating this aliasing in this paper. In addition, we propose the efficient signal processing algorithm.

  • PDF

Study on Intravenous Drip Anesthesia of Ketamine Hydrochloride in Dogs (개에 있어서 Ketamine Hydrochloride의 정맥내 점적마취에 관한 연구)

  • Kim Nam-Soo;Choi In-Hyuk
    • Journal of Veterinary Clinics
    • /
    • v.8 no.1
    • /
    • pp.81-91
    • /
    • 1991
  • This study was carried out to investigate the effects of intravenous drip with ketamine hydrochloride and its application for control depth and maintenance of anesthesia in dogs. Changes of blood pressure, vital signs, blood gas and anesthetic state were observed in this study. The obtained were summerized as follows ; 1. Changes of blood pressure and heart rate after intravenous drip anesthesia with ketamine hydrochloride were observed with significant increase in all group ; group II (0.135m81k9/min), group III (0.269mg/kg/min) and group IV(0.538mg/kg/min). These conditions were maintained unchangeably until 160 minutes after administration in all group. This may be indicated that there were no side effects on account of ketamine accumulation. 2. There were irregular respiration, pain reflex, Jaw tone reflex and vomition probability in the anesthetic conditions of group II The anesthetic conditions of group III were rarely shown as mentioned above. Awakening time and recovery time of group H were more prolonged 21 minutes and 27 minutes respectively than those of group III. These experimental data suggested that the optimal dosage of intravenous drip anesthesia of ketamine Hcl was 0.269mg/kg/min.

  • PDF

Left Ventricular Volume Measurement by Count Method with Attenuation Correction in Gated Blood Pool scan (심장풀스캔에서 방사능 계측법에 의한 좌심실 용적의 측정 -조직 감쇄의 보정에 의한 연구-)

  • Bom, Hee-Seung;Chung, June-Key;Lee, Myung-Chul;Cho, Bo-Youn;Koh, Chang-Soon;Kim, Ji-Yeul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.21 no.1
    • /
    • pp.33-37
    • /
    • 1987
  • Attenuated end-diastolic and end-systolic left ventricular counts which obtained from cardiac gated blood pool scan were corrected using experimentally calculated attenuation coefficient $(\mu=0.13/cm)$ and depth of center of left ventricle. This method was confirmed to be correct experimentally using phantom balloon. To compare the accuracy of attenuated and attenuation-corrected left ventricular volume measurement, authors studied 10 patients with ischemic heart disease who underwent both gated blood pool scan and X-ray contrast ventriculography within a week. The attenuated and attenuation-corrected left ventricular volume measured by count method correlated with contrast ventriculographic volumes; however, attenuation corrected measurement was correlated more closely.

  • PDF

Development of ResNet-based WBC Classification Algorithm Using Super-pixel Image Segmentation

  • Lee, Kyu-Man;Kang, Soon-Ah
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.4
    • /
    • pp.147-153
    • /
    • 2018
  • In this paper, we propose an efficient WBC 14-Diff classification which performs using the WBC-ResNet-152, a type of CNN model. The main point of view is to use Super-pixel for the segmentation of the image of WBC, and to use ResNet for the classification of WBC. A total of 136,164 blood image samples (224x224) were grouped for image segmentation, training, training verification, and final test performance analysis. Image segmentation using super-pixels have different number of images for each classes, so weighted average was applied and therefore image segmentation error was low at 7.23%. Using the training data-set for training 50 times, and using soft-max classifier, TPR average of 80.3% for the training set of 8,827 images was achieved. Based on this, using verification data-set of 21,437 images, 14-Diff classification TPR average of normal WBCs were at 93.4% and TPR average of abnormal WBCs were at 83.3%. The result and methodology of this research demonstrates the usefulness of artificial intelligence technology in the blood cell image classification field. WBC-ResNet-152 based morphology approach is shown to be meaningful and worthwhile method. And based on stored medical data, in-depth diagnosis and early detection of curable diseases is expected to improve the quality of treatment.