• Title/Summary/Keyword: Blood characteristics

Search Result 1,986, Processing Time 0.025 seconds

Flow Visualization of Blood Cell and Detection of Cell Depleted Layer Using a Confocal Laser Scanning Microscope (공초점 레이저 주사 현미경을 이용한 혈구 유동가시화 및 세포공핍층 측정에 관한 연구)

  • Lim, Soo-Hee;Kim, Wi-Han;Lee, Ho;Lee, Choon-Young;Park, Cheol-Woo
    • Journal of the Korean Society of Visualization
    • /
    • v.8 no.1
    • /
    • pp.46-52
    • /
    • 2010
  • In the present study, we employed the confocal laser scanning microscopy (CLSM) system to visualize the blood flow field with $1{\times}1{\mu}m^2$ spatial resolution. Based on the confocal microscopic image of red blood cells (RBCs), we performed the velocity vector field measurement and evaluated characteristics of cell migration from the cell depleted layer thickness calculation. The rat and mouse's blood were supplied into a micro glass tubes in vitro. The line scanning rate of confocal microscopy was 15 kHz for a $500{\times}500$ pixels image. As a result, the red blood cell itself can be used as a tracer directly without any kind of invasive tracer particle to get the velocity vector field of blood flow by performing particle image velocimetry (PIV) technique.

A Study on the Performance and Utilization of Results of Self-monitoring of Blood Glucose in Type Ⅱ Diabetes (일 병원 제2형 당뇨병환자의 자가혈당검사 수행 및 활용 실태)

  • Ha, Jung-Mi;Kim, Dong-Hee
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.16 no.2
    • /
    • pp.330-338
    • /
    • 2010
  • Purpose: This study was conducted to investigate performance of self-monitoring of blood glucose and the utilization of results for people with type II diabetes. Method: Data was collected from 177 patients with type II diabetes using a questionnaire from August to September, 2009. Result: Most participants performed self-monitoring of blood glucose in the correct way while some misused the lancet or test strips. In the utilization of results for self-monitoring blood glucose data, 62% of participants always recorded the data, 46% always understood the cause for hyperglycemia or hypoglycemia, 25% changed their diet, 23% regulated their exercise-amount, and 11% of participants adjusted the drug dosage. There were significant differences in the performance of self-monitoring of blood glucose and the utilization of results according to the characteristics in the self-monitoring subjects such as awareness of HbA1c, target fasting glucose level, target fasting glucose level 2 hours after meal etc. Conclusion: Systemic self-monitoring of blood glucose education which includes the utilization of self-monitoring of blood glucose needs to be developed for type II diabetic patients.

In Vivo Blood Compatibility of PU-PEO-SO3 as Coating Material for Blood Sac of Left Ventricular Assist Device ( LVAD) (좌심실보조장치의 혈액주머니용 코팅재료로서 PU-PEO-SO3의 in vivo 혈액적합성에 관한 연구)

  • 한동근;김종원
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.1
    • /
    • pp.19-26
    • /
    • 1994
  • Sulfonated poly (ethyleneoxide)-grafted polyurethane (PU-PEO-$SO_3$) prepared by bulk modification was coated on a blood sac for electrohydraulic left ventricular assist device (ELVAD) implanted in dogs and its in vivo blood compatibility on shear stress was studied as compared with untreated Po. The effect of the wall shear stress on the protein adsorption unlike platelet adhesion is dependent on the surface characteristics of the material, although less proteins seem to be adsorbed in the region of the high shear stress. The thickness of total proteins adsorbed on PU-PEO-SOJ (400 ${\AA}$) by trans¬mission electron microscopy(TEM) was considerably lower than that of untreated PU(l,000~1,600 ${\AA}$), but PU-PEO-$SO_3$ showed high albumin adsorption, low fibrinogen and IgG adsorption, and low platelet adhesion as compared with untreated PU, suggesting that PU-PEO-$SO_3$ is more in vivo blood compatible. Therefore, it appears that such a blood compatible PU-PEO-$SO_3$ is useful for blood contacting biomaterials including artificial organs.

  • PDF

Mock Circulatory Robot with Artificial Aorta for Reproduction of Blood Pressure Waveform (혈압 파형 재현을 위한 인공 대동맥 기반 모의 순환계 로봇)

  • Jae-Hak Jeong;Yong-Hwa Park
    • The Journal of Korea Robotics Society
    • /
    • v.19 no.2
    • /
    • pp.221-228
    • /
    • 2024
  • As the importance of cardiovascular health is highlighted, research on its correlation with blood pressure, the most important indicator, is being actively conducted. Therefore, extensive clinical data is essential, but the measurement of the central arterial blood pressure waveform must be performed invasively within the artery, so the quantity and quality are limited. This study suggested a mock circulatory robot and artificial aorta to reproduce the blood pressure waveform generated by the overlap of forward and reflected waves. The artificial aorta was fabricated with biomimetic silicone to mimic the physiological structure and vascular stiffness of the human. A pressurizing chamber was implemented to prevent distortion of the blood pressure waveform due to the strain-softening of biomimetic silicone. The reproduced central arterial blood pressure waveforms have similar magnitude, shape, and propagation characteristics to humans. In addition, changes in blood pressure waveform due to aging were also reproduced by replacing an artificial aorta with various stiffness. It can be expanded to construct a biosignal database and health sensor testing platform, a core technology for cardiovascular health-related research.

A Study on the Development of CW(Continuous-Wave)Doppler System for measuring Bi-directional Blood Flow Information (혈류 방향을 구별하는 연속 초음파 도플러 장치에 관한 연구)

  • 강충신;김영길
    • Journal of Biomedical Engineering Research
    • /
    • v.8 no.1
    • /
    • pp.75-80
    • /
    • 1987
  • With the conventional CW Doppler velocity meter, bl-directional velocities cannot be separated. The new CW Doppler system uses quadrature detection and phase rotation to produce simultaneous independent audio and velocity signals for forward and reverse blood flow direction, is fabricated. Specially, this system shows that phase rotation method for flow direction separation provides easy and satisfactory feature. From in vivo blood flow measurement, we can easily differentiate typical artery flow from vein flow, and measure both velocity characteristics qualitatively.

  • PDF

A Study on the Analysis of Oriental Functional Beverage and on the Blood Alcohol Concentration or Rat after Drinking Liquors (한방 기능성 음료분석 및 섭취후 흰쥐의 혈중 알코올 농도에 관한 연구)

  • 서광희;김성연
    • The Korean Journal of Food And Nutrition
    • /
    • v.14 no.3
    • /
    • pp.222-227
    • /
    • 2001
  • The production results of the oriental functional beverage, which is aimed at reducing the alcohol concentration in blood, are as follows. Different kinds of herb medicine ingredients were combined to achieve the balance between Yin And Yang. They were grouped according to their respective characteristics and extracted by heat, Then they were combined and produced following the most effective mixture ratio. The drink produced by this way consisted mainly of water, Sugar, mineral, protein and fiber were partially contained. Among the minerals, the proportion of calcium, potassium, magnesium was high and iron was also contained. This drink turned out to be effective in reducing the alcohol concentration in blood within a very short time when it was taken once after drinking and taken aging 30 minutes later, which would double the dosage. This result shows that development of such a functional beverage using the herbal medicine, At the same time it will play an important part in reducing the alcohol concentrate in blood after drinking liquors.

  • PDF

Fluid-structure interactions of physiological flow in stenosed artery

  • Buriev, Bahtiyor;Kim, Tae-Dong;Seo, Tae-Won
    • Korea-Australia Rheology Journal
    • /
    • v.21 no.1
    • /
    • pp.39-46
    • /
    • 2009
  • Atherosclerosis is a disease that narrows, thickens, hardens, and restructures a blood vessel due to substantial plaque deposit. The geometric models of the considered stenotic blood flow are three different types of constriction of cross-sectional area of blood vessel; 25%, 50%, and 75% of constriction. The computational model with the fluid-structure interaction is introduced to investigate the wall shear stresses, blood flow field and recirculation zone in the stenotic vessels. The velocity profile in a compliant stenotic artery with various constrictions is subjected to prescribed physiologic waveform. The computational simulations were performed, in which the physiological flow through a compliant axisymmetric stenotic blood vessel was solved using commercial software ADINA 8.4 developed by finite element method. We demonstrated comparisons of the wall shear stress with or without the fluid-structure interaction and their velocity profiles under the physiological flow condition in the compliant stenotic artery. The present results enhance our understanding of the hemodynamic characteristics in a compliant stenotic artery.

Flexible wireless pressure sensor module

  • Shin Kyu-Ho;Moon Chang-Ryoul;Lee Tae-Hee;Lim Chang-Hyun;Kim Young-Jun
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2004.11a
    • /
    • pp.3-4
    • /
    • 2004
  • A flexible Packaging scheme, which embedded chip packaging, has been developed using a thinned silicon chip. Mechanical characteristics of thinned silicon chips are examined by bending test and finite element analysis. Thinned silicon chips ($t<50{\mu}m$) are fabricated by chemical etching process to avoid possible surface damages on them. These technologies can be use for a real-time monitoring of blood pressure. Our research targets are implantable blood pressure sensor and its telemetric measurement. By winding round the coronary arteries, we can measure the blood pressure by capacitance variation of blood vessel.

  • PDF

No Association of the Human Y Chromosome with Blood Pressure in Korean Male Population

  • Kang, Byung-Yong;Kim, Seon-Jeong;Lee, Kang-Oh
    • Toxicological Research
    • /
    • v.19 no.1
    • /
    • pp.29-31
    • /
    • 2003
  • It has been reported that the genetic variations in the Y chromosome has influence the blood pressure in some Caucasian male populations, but the effect in non-Caucasian population is unclear. In the present study, we examined the relationship between blood pressure and a HindIII RFLP of Y chromosome in 152 unrelated male individuals of ethnically homogeneous Korean origin. There were no significant differences in systolic and diastolic blood pressures between genotype groups, respectively. However, the frequency of A genotype in Korean population was much higher than those of Caucasian populations (P<0.05). Therefore, the results of this study will con-tribute the better understanding the genetic characteristics of Y chromosome in Korean population.

Visualization of blood sucking phenomena of a female mosquito (암 모기 흡혈과정 가시화)

  • Kim, Bo-Heum;Lee, Sang-Joon
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.114-115
    • /
    • 2007
  • As a carrier of malaria and sneak of blood, mosquitoes are regarded as an unpleasant insect. However, there are novel phenomena that happen inside a mosquito. Among them, we focused on the blood sucking function of a female mosquito. The main objective of this study was to investigate the mosquito's pumping mechanism in order to resolve the problem encountered when we inject or transport biologic fluids into a micro-chip. To analyze the pumping mechanism, we visualized the blood sucking process inside a female mosquito. Flow characteristics of blood flow in a proboscis were investigated experimentally using a micro-PIV velocity field measurement technique. The anatomical variation of head, thorax, abdomen which work as pumps and valves, was visualized using the syncrotron X-ray micro-imaging technique.

  • PDF