• Title/Summary/Keyword: Blood Pressure Measurement

Search Result 401, Processing Time 0.024 seconds

Implementation of the Blood Pressure and Blood Flow Variation Rate Detection System using Impedance Method (임피던스법을 이용한 혈압 및 혈류 변화량 검출 시스템 구현)

  • Ro, Jung-Hoon;Bae, Jin-Woo;Ye, Soo-Young;Shin, Bum-Joo;Jeon, Gye-Rok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.8
    • /
    • pp.1926-1938
    • /
    • 2009
  • In this study, detection system of the blood flow variation rate was implemented using the variation effect of bio electric impedance at time of the blood pressure measurement by means of impedance method. The blood pressure measurement was performed by the oscillometric method. The mean arterial pressure was calculated using maximum amplitude algorithm. The systolic and diastolic pressure were estimated by establishment of the various characteristic ratio according to mean arterial pressure range. Alternative static current source and lock_in amplifier were introduced to impedance measurement. The variation of blood volume was measured using variation bio impedance according to induced cuff pressure at measuring area.

Implementation of Noninvasive Blood Pressure Measuring System for Home Health Care Using Oscillometric Method (오실로메트릭법을 적용한 홈헬스케어용 비침습적 혈압측정법의 구현)

  • Kang Seong-Chul;Jeon Gye-Rock;Jeong Do-Un
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.689-692
    • /
    • 2006
  • In this study, an implementation of a system for measuring more accurate blood pressure by non-invasive methods of oscillometric was performed to reduce errors and weaknesses of the existing invasive blood pressure measurement methods. The system is composed of pressure control, signal measurement and blood pressure signal processing units. To verify the validity of the system, tests of characteristics evaluations for pressure measurement unit, extraction of characteristic ratios for blood pressure estimation, blood pressure tracking by oscillometric method were performed. A group of five adult male was selected for the clinical test of the implemented system. The results of the oscillometric method in comparison with auscultatory method are that the maximum ratios of PAD of average, systolic and diastolic arterial pressure are 1.38%, 1.63% and 2.97% with SEP of 5.00, 3.72 and 4.34.

  • PDF

Development of an Automatic Blood Pressure Device based on Korotkoff Sounds

  • Li, Xiong;Im, Jae Joong
    • International journal of advanced smart convergence
    • /
    • v.8 no.2
    • /
    • pp.227-236
    • /
    • 2019
  • In this study, we develop a Korotkoff sound based automatic blood pressure measurement device including sensor, hardware, and analysis algorithm. PVDF-based sensor pattern was developed to function as a vibration sensor to detect of Korotkoff sounds, and the film's output was connected to an impedance-matching circuit. An algorithm for determining starting and ending points of the Korotkoff sounds was established, and clinical data from subjects were acquired and analyzed to find the relationship between the values obtained by the auscultatory method and from the developed device. The results from 86 out of 90 systolic measurements and 84 out of 90 diastolic measurements indicate that the developed device pass the validation criteria of the international protocol. Correlation coefficients for the values obtained by the auscultatory method and from the developed device were 0.982 and 0.980 for systolic and diastolic blood pressure, respectively. Blood pressure measurements based on Korotkoff sound signals obtained by using the developed PVDF film-based sensor module are accurate and highly correlated with measurements obtained by the traditional auscultatory method.

Development of Blood Pressure Estimation Methods Using The PPG and ECG Sensors (PPG 및 ECG 센서를 이용한 혈압추정 기법 개발)

  • Park, Hyun-Moon;Lee, Jung-Chul;Hwang, Tae-Ho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.6
    • /
    • pp.1257-1264
    • /
    • 2019
  • The traditional cuff-based method for BP(Blood Pressure) measurement is not suitable for continuous real-time BP measurement techniques. For this reason, the previous studies estimated various blood pressures by fusion with the electrocardiography (ECG) and photoplethysmogram (PPG) sensor signals. However, conventional techniques based on PPG bio-sensing measurement face many challenging issues such as noisy supply fluctuation, small pulsation, and drifting non-pulsatile. This paper proposed a novel BP estimation methods using PPG and ECG sensors, which can be derived from the relationship between PPG and ECG using PTT(Pulse Transit Time) and PWV(Pulse Wave Velocity). Unlike conventional height ratio features, which are extracted on the basis of the peaks in the PPG and ECG waveform. The proposed method can be reliably obtained even if there are missing peaks among the sensed PPG signal. The increased reliability comes from periodical estimation of the peak-to-peak interval time using ECG and PPG. After 250,000 times trials of the blood pressure measurement, the proposed estimation technique was verified with the accuracy of ±28.5% error, compared to a commercialized BP device.

Non-intrusive measurement of pulse arrival time and Estimation of Systolic Blood Pressure (무구속적 맥파 전달 시간의 측정을 통한 혈압 추정)

  • Chee, Young-Joon;Park, Kwang-Suk
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.489-492
    • /
    • 2005
  • Even though the blood pressure is one of the most widely used index for the healthcare monitoring of hypertensive and normotensive persons, there is no non-intrusive measurement method which is commercialized until now. Pulse Arrival Time (PAT) is known that it has close relation with the systolic blood pressure (SBP) and arterial stiffness. In this study, SBP estimation methods by non-intrusive measurement of PAT are suggested. For the unconstrained measurement of PAT, the first method used the electrically non contact electrocardiogram (ENC-ECG) technique and the reflective type of Photoplethysmography (PPG) sensor on the computer mouse. In the second method, ENC-ECG and the air pressure sensor in the seat cushion on a chair were measured. The third method used ECG electrodes and PPG sensors on the toilet seat cover. The validation and regression analysis of the relationship of PAT and SBP are summarized. These methods have considerable errors to be used for all people. But these can be applied for each subject after the parameter customization within acceptable error. So, it is feasible for suggested methods to be used for monitoring of SBP in daily life in non-intrusive way when there is personal identification system of each subject.

  • PDF

Effects of the Body Shaping Foundation on Blood Flow and Wearer Comfort for Middle-aged Women (시판 체형보정용 파운데이션이 중년여성의 혈류 및 착용 쾌적감에 미치는 영향)

  • Kim, Nam Yim;Park, Gin Ah
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.45 no.3
    • /
    • pp.495-509
    • /
    • 2021
  • The study investigated the effects of five commercial body shaping foundation items on clothing pressure, blood flow, body shaping effectiveness, and wearer satisfaction for middle-aged women. The study measured clothing pressure at each of the 10 designated measurement points for twelve subjects wearing the foundations. Blood flow changes were recorded and body shaping effectiveness was analyzed by comparing differences in girth when wearing and not wearing the foundations. The subjects rated wearer comfort along a 7-point Likert scale. The results were that clothing pressure was present at all measurement points, and all foundations placed the least pressure on the anterior underbust girth. In addition, clothing pressure was high in the order of the lateral, posterior, and anterior areas. As clothing pressure increased, blood flow and velocity decreased and overall wearer satisfaction was assessed to be less comfortable. Body shaping effectiveness was evident across all the items, as all decreased girth measurements significantly. In conclusion, the appropriate level of clothing pressure provided by experimental foundations which is positive for blood flow and has an excellent body shaping effect was found to be between 0.53 and 1.77 kPa.

Blood Viscosity Measurements Using a Pressure-Scanning Capillary Viscometer

  • Sehyun Shin;Keum, Do-Young;Ku, Yun-Hee
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.12
    • /
    • pp.1719-1724
    • /
    • 2002
  • A previously designed capillary viscometer with measuring differential pressure was modified to measure the viscosity of non-Newtonian fluids including unadulterated blood continuously over numerous shear rates in a single measurement. Because of unavoidable experimental noise and a limited number of data, the previous capillary viscometer experienced an inaccuracy and could not directly determine a viscosity without an iterative calculation. However, in the present measurement there are numerous data available near the point of interest so that the numeric value of the derivative, d(In Q)/d(In Q$\sub$w/), is no longer sensitive to the method of differentiation. In addition, relatively low and wide shear rate viscosity measurements were possible because of the present precision pressure-scanning method with respect to time. For aqueous polymer solutions, excellent agreement was found between the results from the pressure-scanning capillary viscometer and those from a commercially available rotating viscometer. In addition, the pressure-scanning capillary viscometer measured the viscosity of unadulterated whole blood without adding any anticoagulants.

A Method to Estimate Peripheral Systolic Blood Pressure using Pulse Transit Time during Bicycle Ergometer Exercise of Healthy Korean Subjects in their Twenties

  • Lee Jeong-Chan;Eo Yun-Hye;Park Kyung-Mo;Park Seung-Hun
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.3
    • /
    • pp.89-93
    • /
    • 2006
  • A simple algorithm that can be used to estimate a healthy person's blood pressure using pulse transit time is proposed in this paper. Fifty healthy students participated in the experiment that was conducted in line with the study. The subjects were asked to exercise on several exercise levels using a bicycle ergometer. Their blood pressures during the succeeding rest period were measured. A simple method was proposed to illustrate the relationship between blood pressure and pulse transit time. The systolic blood pressures as well as the heights and weights of the subjects were regarded as the proper parameters, and a second-order regression curve was produced to estimate the subjects' blood pressures. The mean error of estimation was less than 10 mmHg, which was the mean error of manual measurement. Although our estimation model is so simple, it can be used to estimate continuous blood pressure measurement for bicycle ergometer exercise. The electrocardiograms, photoplethysmograms, and blood pressures, however, could not be measured simultaneously As such, their estimation may be slightly different from the results taken from simultaneous measurements.

Cerebral blood flow enhancement device using Blood Oxygen Level Sensor (Blood Oxygen Level Sensor를 이용한 대뇌혈류증가 장치)

  • Lim, Jung-hyun;Joh, In-Hee;Kim, Young-kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.8
    • /
    • pp.1083-1089
    • /
    • 2018
  • Surgery to increase cerebral blood flow is one of the treatment methods of cerebral infarction. In order to supplement this invasive method, non-invasive devices have been introduced that use human blood pressure to pressurize the extremities to increase cerebral blood flow. However, the problem of poor speed and accuracy was raised. In this paper, the perfusion index of each arm is measured by applying pressure to both arms using Blood Oxygen Level Sensor to improve the accuracy of measurement and measurement time. The pressure applied to the arm is calculated by using the pressure value obtained from the arm. Like the existing blood pressure measuring cerebral blood flow increasing device, the blood flow can be increased by more than 20% and the measurement time can be shortened, so that it can be selectively used for the patient with cerebral infarction.

Development of Blood Pressure Measurement Method Using ANFIS (ANFIS를 이용한 전자 혈압 측정 알고리즘 개발)

  • Chun Myung-Geun;Kwon Seok-Young;Lee Dae-Jong
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.16 no.4
    • /
    • pp.493-498
    • /
    • 2006
  • In this paper, we propose a blood pressure measurement method using ANFIS. Usually, the maximum and minimum blood pressures are calculated by Maximum Amplitude Algorithm(MAA) method. However, the MAA method has some drawbacks to measure exact blood pressure since it uses a fixed ratio to set the measuring points for everyone without considering individual's special conditions. To solve this problem, the pressures measured by the MMA are trained by ANFIS having self-learning ability. From various experiments, we confirm that the proposed method shows better performance than conventional method.