• Title/Summary/Keyword: Blood Flow Rate

Search Result 486, Processing Time 0.029 seconds

Implementation of Non-Invasive Pressurized Cerebral Perfusion Platform (가압식 비침습적 대뇌 혈류 증가 장치의 구현)

  • Lee, Jean;Yu, Hyung-gon;Kim, Young-kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.9
    • /
    • pp.1752-1760
    • /
    • 2017
  • One of the treatments and preventions of strokes such as ischemic stroke is to increase cerebral blood flow. This aims to minimize the size of the stroke by increasing the quantity of blood to the cerebral region circuitously. Several ways to increase cerebral blood flow are a therapy though drugs and through surgery. However these invasive method giving a burden to the patient, the problem of inducing a number of complications were noted. In this thesis, we propose a non-invasive brain flow enhancer to complement the disadvantages of such invasive treatment methods. To compensate for the shortcomings of the existing devices, the patient's blood pressure is accurately measured and the blood pressure is applied to the extremities, thereby increasing blood flow to the femoral region to produce blood clotting treatments. Although somewhat inadequate blood flow increases compared to conventional devices, blood flow can be significantly increased, which can be selectively.

Effects of Head-down Tilt $(-6^{\circ})$ on Peripheral Blood Flow in Dogs (두부하위$(-6^{\circ})$로의 체위변동이 말초혈류에 미치는 영향)

  • Chae, E-Up;Yang, Seon-Young;Bae, Jae-Hoon;Song, Dae-Kyu
    • The Korean Journal of Physiology
    • /
    • v.24 no.1
    • /
    • pp.51-65
    • /
    • 1990
  • The purpose of the present study was to examine the hemodynamic responses, especially in arterial and skin blood flows, in conjunction with the changes of plasma catecholamine levels as an indirect marker of adrenergic tone during the early stage of head-down tilt (HDT), and to evaluate the early physiological regulatory mechanism in simulated weightlessness. Ten mongrel dogs, weighing8\;{\sim}\;14\;kg, were intravenously anesthetized with nembutal, and postural changes were performed by using the tilting table. The postural changes were performed in the following order: supine, prone, HDT $(-6^{\circ}C)$ and lastly recovery prone position. The duration of each position was 30 minutes. The measurements were made before, during and after each postural change. The arterial blood flow $({\.{Q}})$ at the left common carotid and right brachial arteries was measured by the electromagnetic flowmeter. Blood pressure (BP) was directly measured by pressure transducer in the left brachial artery. To evaluate the peripheral blood flow, skin blood flow $({\.{Q}})$ was calculated by the percent changes of photoelectric pulse amplitude on the forepaw, and skin temperature was recorded. The peripheral vascular resistance (PR) was calculated by dividing respective mean BP values by ${\.{Q}}$ of both sides of common carotid and brachial arteries. Heart rate (HR), respiratory rate (f) and PH, $Po_{2},\;Pco_{2}$ and hematocrit of arterial and venous blood were also measured. The concentration of plasma epinephrine and norepinephrine was measured by radioenzymatic method. The results are summarized as follows: Tilting to head-down position from prone position, HR was initially increased (p<0.05) and BP was not significantly changed. While ${\.{Q}}$ of the common carotid artery was decreased (p<0.05) and PR through the head was increased, ${\.{Q}}$ of the brachial artery was increased (p<0.05) and PR through forelimbs was decreased. ${\.{Q}}$ of the forepaw was initially increased (p<0.05) and then slightly decreased, on the whole revealing an increasing trend. Plasma norepinephrine was slightly decreased and the epinephrine was slightly increased. f was increased and arterial pH was increased (p<0.05). In conclusion, the central blood pooling during HDT shows an increased HR via Bainbridge reflex and an increased ${\.{Q}}$ of the forepaw and brachial ${\.{Q}}$, due to decreased PR which may be originated from the depressor reflex of cardiopulmonary baroreceptors. It is suggested that the blood flow to the brain was adequately regulated throughout HDT $(-6^{\circ}C)$ in spite of central blood pooling. And it is apparent that the changes of plasma norepinephrine level are inversely proportional to those of ${\.{Q}}$ of the forepaw, and the changes of epinephrine level are paralleled with those of the brachial ${\.{Q}}$.

  • PDF

Numerical study of the effects of periodic body acceleration (PGZ) and bifurcation angle in the stenosed artery bifurcation

  • Ro, Kyoung-Chul;Ryou, Hong-Sun
    • Korea-Australia Rheology Journal
    • /
    • v.21 no.3
    • /
    • pp.175-183
    • /
    • 2009
  • This article describes the numerical investigation of blood flow in the stenosed artery bifurcation with acceleration of the human body. Using the commercial software FLUENT, three-dimensional analyses were performed for six simulation cases with different body accelerations and bifurcation angles. The blood flow was considered to be pulsation flow, and the blood was considered to be a non-Newtonian fluid based on the Carreau viscosity model. In order to consider periodic body acceleration, a modified, time-dependent, gravitational-force term was used in the momentum equation. As a result, flow variables, such as flow rate and wall shear stress, increase with body acceleration and decrease with bifurcation angle. High values of body acceleration generate back flow during the diastolic period, which increases flow fluctuation and the oscillatory shear index at the stenosis.

Flow Visualization of Blood Cell and Detection of Cell Depleted Layer Using a Confocal Laser Scanning Microscope (공초점 레이저 주사 현미경을 이용한 혈구 유동가시화 및 세포공핍층 측정에 관한 연구)

  • Lim, Soo-Hee;Kim, Wi-Han;Lee, Ho;Lee, Choon-Young;Park, Cheol-Woo
    • Journal of the Korean Society of Visualization
    • /
    • v.8 no.1
    • /
    • pp.46-52
    • /
    • 2010
  • In the present study, we employed the confocal laser scanning microscopy (CLSM) system to visualize the blood flow field with $1{\times}1{\mu}m^2$ spatial resolution. Based on the confocal microscopic image of red blood cells (RBCs), we performed the velocity vector field measurement and evaluated characteristics of cell migration from the cell depleted layer thickness calculation. The rat and mouse's blood were supplied into a micro glass tubes in vitro. The line scanning rate of confocal microscopy was 15 kHz for a $500{\times}500$ pixels image. As a result, the red blood cell itself can be used as a tracer directly without any kind of invasive tracer particle to get the velocity vector field of blood flow by performing particle image velocimetry (PIV) technique.

Development and Evaluation of a Novel Electro-mechanical Implantable Ventricular Assist System (전기-기계식 이식형 좌심실 보조 시스템의 개발 및 평가)

  • 조한상;김원곤;이원용;곽승민;김삼성;김재기;김준택;류문호;류은숙
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.4
    • /
    • pp.349-358
    • /
    • 2001
  • A novel electro-mechanical implantable ventricular assist system is developed as a bridge to transplantation or recovery for patients with end-stage heart failure. The developed system is composed of an implanted blood pump, an external monitoring system which stores data, and a wearable system including a portable external driver and a portable power supply system. The blood pump is designed to be implanted into the left upper abdominal space and provides blood flow from the left ventricular apex to the aorta. The pulsatile blood flow is generated by a double cylindrical cam. There was mo excessive heat emission from the blood pump into the temperature-controlled chamber in the heat test and no stagnated flow within the blood sac by the observation in the flow visualization test. Animal experiments were performed using sheep and calves. The maximum assist flow rate reached 7.85L/min in the animal experiment. The evaluation results showed that the developed system was feasible for the implantable ventricular assist system. The long-term in vitro durability test and mid-term in vivo experiments are in progress and mow the modified next model is under development.

  • PDF

Effect of Cimetidine on the Hepatic Blood flow -On the Basis of Pharmacokinetics of Indocvanine Green in Rats- (시메티딘이 간혈류량에 미치는 영향 - Rat에 있어서 Indocyanine Green의 체내 동태를 중심으로 -)

  • Lee, Yong-Bok;Koh, Ik-Bae
    • Korean Journal of Clinical Pharmacy
    • /
    • v.3 no.2
    • /
    • pp.163-168
    • /
    • 1993
  • The influence of cimetidine pretreatment(100mg/kg, single i.p.) on the hepatic blood flow was investigated using pharmacokinetic parameters of indocyanine green(ICG) in the rat on the basis of hepacc perfusion-limited model. ICG(1mg/kg) was respectively administered via femoral and portal vein to the control and to the cimetidine-pretreated rats. The rate constant K12, K20 and the systemic clearance(CLt) of ICG were significantly(p<0.05) decreased ill the cimetidine-pretrea-to(B rats, but no significant diffirences were observed in hematocrit and liver weight. The biliary excretion rates of ICG were also decreased regardless of the route of administration in the cimetidine-pretreated rats. And also the hepatic blood flow in rats was decreased about $16\%$ by cimetidine. It may be concluded that the decreased hepatic blood flow with cimetidine mainly contributed to the decreased hepatic uptake and the decreased systemic clearance of ICG.

  • PDF

A Spatial Average Method Using 2nd Order Sampling in Ultrasonic Doppler System (초음파 도플러 시스템에서 2차 샘플링을 이용한 공간축상의 평균 방법)

  • 백광렬
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.3
    • /
    • pp.279-288
    • /
    • 1995
  • Ultrasonic Doppler systems for the purpose of estimating blood flow velocity, blood flow volume, and flow imaging are commonly used due to advantages of non-invasive and real time observation. Specially, the technical developments of color flow mapping (2-D Doppler) systems have made a relatively rapid progress. However, the 2-D Doppler systems have several problems, such as the range ambiguity, low signal to noise ratio, and slow frame rate. The slow frame rate problem is resolved by using the spatial average which is a method to acquire more data samples for mean frequency estimation. In this paper, spatial average method using the 2nd order sampling instead of quadrature sampling is proposed. The experimental results show that the proposed methods have good performance and easy application to the color flow mapping system.

  • PDF

The Effects of Panax ginseng and P. quinquefolium on Hemodynamics and Body Temperature in Healthy Young Men (II)

  • Lee, Jee-Hwan;Cho, Jung-Ah;Ki, Chan-Young;Son, Yeon-Kyoung;Park, Jeong-Hill;Park, Man-Ki;Han, Yong-Nam
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.318-318
    • /
    • 2003
  • The current study was performed to observe the effects of Panax ginseng (PG) and P. quinquefolium (PQ) on hemodynamics such as blood flow rate (BF), blood flow velocity (BV), heart rate (HR), systolic blood pressure (SBP), and diastolic blood pressure (DBP) and body temperature (BT) in healthy young men. This is a randomized, single-blind study observed during 6 hrs after orally single administration of PG and PQ groups. (omitted)

  • PDF

Effect of 2-Methylaminoethyl-4,4'-Dimethoxy-5, 6, 5' ,6'-Dimethyl­enedioxybiphenyl-2-Carboxylic Acid-2'-Carboxylate Monohydro­chloride (DDB-S) on Indocyanine Green (ICG) Clearance in Rats

  • Lee Kyoung-Jin;Kim Jae-Ryung;Lee Chi-Ho
    • Archives of Pharmacal Research
    • /
    • v.28 no.1
    • /
    • pp.115-119
    • /
    • 2005
  • The clearance of ICG, a known hepatic blood flow marker was investigated in rats in order to examine whether DDB-S influences hepatic blood flow. The effect of DDB-S on the protein binding and blood-to-plasma partition of ICG was measured. The steady-state plasma concentration of ICG was monitored before and after co-administration of various concentration of DDB-S, and ICG clearance was estimated from the steady-state concentration and the infusion rate of ICG. There was no significant difference in protein binding and blood-to-plasma partition of ICG with and without addition of DDB-S (10, 20, and 40 ${\mu}g/mL)$. When ICG was infused into DDB-S pretreated rats, the steady-state concentrations of ICG decreased and the calculated ICG clearance increased. However, no dose-dependency of ICG Css on DDB-S Css was observed. Since DDB-S did not affect the protein binding and blood-to-plasma partition of ICG, the increased clearance of ICG with co-administration of DDB-S seems to be due to the increased hepatic blood flow by DDB-S.

Change of Cerebral Blood Flow during Tilt Tests in Children with Vasovagal Syncope (혈관미주 신경성 실신 소아에서 기립경사 검사 동안에 뇌혈류 변화)

  • Kim, Su Jung;Yom, Hye Won;Hong, Young Mi;Yoo, Jung Hyen;Lee, Sook Hee;Kim, Chong Hee
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.10
    • /
    • pp.983-988
    • /
    • 2003
  • Purpose : Syncope appears to be common. However, the mechanism of syncope is not clear. Increased vagal activity and withdrawal of sympathetic stimulation cause hypotension, bradycardia and finally loss of consciousness. The purpose of this study was to evaluate changes of cerebral blood flow velocity, blood pressure, and heart rate during tilt test in children with vasovagal syncope. Methods : Sixty four children with a past history of syncope were evaluated. The stand up test was performed for 15 minutes after a rest at supine position for 10 minutes, followed by an $80^{\circ}$ tilt test lasting 45 minutes. If presyncope(lightheadedness, nausea, blurred vision, or sweating) or syncope occurred, the study was discontinued. 12-lead electrocardiography, echocardiography, and electroencephalography were performed. Transcranial Doppler study was performed at the middle cerebral artery with 2 MHz continuous Doppler probe in 10 children with positive tilt test. Systolic, diastolic, mean cerebral blood flow velocity, integral, and pulsatility index were measured with blood pressure, heart rate, and $O_2$ saturation. Results : The positive rate of tilt test was 31.3%(20/64). Systolic, diastolic, and mean cerebral blood flow velocity decreased significantly in absence of hypotension or bradycardia during presyncope. Time velocity integral of cerebral artery also decreased significantly. Conclusion : Decreased cerebral blood flow velocity can predict the presyncope manifestation. Impairment of autoregulation of cerebral blood flow might play an important role in the pathophysiology of vasovagal syncope.