• Title/Summary/Keyword: Blood Flow Rate

Search Result 487, Processing Time 0.03 seconds

Hemodynamic Modeling of the Pulsatile Cardiac Pulmonary Perfusion for the Patient's Heart (환자의 박동형 심장의 폐순환 혈류 모델링에 대한 연구)

  • Kim, J.S.;Kim, M.S.;Choi, S.W.
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1679-1682
    • /
    • 2008
  • Pulsatile Extracorporeal Membrane Oxygenation(ECMO) can mitigate the heart load and raise the patient's blood perfusion. But If the ECMO pulsate the blood flow during the systolic period, It can burden to the patient's heart. To avoid the heart injury, we have to consider the relation between output of ECMO, hemodynamic states and heart movement. To raise the efficacy of the pulsatile ECMO, we investigated the coronary perfusion, cardiac muscle tension and hemodynamic states during the ECMO perfusion by using the mathematical model of human blood circulatory system and ECMO. The outflow data of the pulsatile ECMO(T-PLS, Bioheartkorea, Korea) was obtained in vitro experiments. According to the phase and pumping rate of the ECMO, the heart's load and coronary perfusion could be adjusted to the proper levels. The results of the human- ECMO lumped parameter model showed that the synchronizing operation of the pulsatile ECLS can be helpful at stabilizing the patient's hemodynamic states.

  • PDF

?Experimental Study on the Effects of Zanthoxyli Fructus and Fagarae mandshuricae Fructus (천초(川椒) 및 산초(山椒)의 효능(?能)에 관(關)한 실험적(實驗的) 연구(硏究))

  • O, Han-Gyun;Won, Jong-Hun;Jeong, Gyu-Man
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.4 no.1
    • /
    • pp.1-17
    • /
    • 1990
  • ?In order to investigate effects of Zanthoxyli Fructus (Sample-A) and Fagarae mandshuricae Fructus (Sample-B), experimental study was performed through observation on isolated - ileum analgesic, hypothermal, anti-pyretic, anti-inflammatory, capillary permeability, blood flow rate, blood pressure and respiratory works. The results were as follows; 1. In spontaneous movement of mice isolated-ileum, both samples were noted to have strong inhibitory action after temporary contraction, and to show antagonism against acetylcholine chloride and barium chloride. 2. Both samples were showed to have antihistamin work on guinea pig isolated-ileum 3. In analgesic work by the acetic acid method, only Fagarae mandshuricae Fructus was proved to have significant analgesic effect in mice. 4. Both sample groups indicated anti-pyretic and anti-inflammatory effect. 5. Both samples were noted to have inhibitory effect against capillary permeability ?rise in mice. ?6. Both samples were noted to have dose-dependent falling effect on blood pressure in rabbits.

  • PDF

Effects of Supplemental Recombinant Bovine Somatotropin (rbST) and Cooling with Misters and Fans on Renal Function in Relation to Regulation of Body Fluids in Different Stages of Lactation in Crossbred Holstein Cattle

  • Boonsanit, D.;Chanpongsang, S.;Chaiyabutr, N.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.23 no.3
    • /
    • pp.355-365
    • /
    • 2010
  • The aim of this study was to investigate the effect of supplemental recombinant bovine somatotropin (rbST) and cooling with misters and fans on renal function in relation to regulation of body fluids in different stages of lactation in crossbred Holstein cattle. Ten, 87.5% crossbred Holstein cattle were divided into two groups of 5 animals each, housing in a normal shaded barn (NS) and in a shaded barn with a mister-fans cooling system (MF). The experiment in each group was divided into 3 phases, early- (Day 75 postpartum), mid- (Day 135 postpartum), and late stage of lactation (Day 195 postpartum). The pre-treatment study was conducted on the starting day of each stage of lactation and the treatment study was performed after the end of the pre-treatment, during which the animal was injected with 500 mg of rbST (POSILAC) every 14 days for three times. During the study, ambient temperature at the hottest period daily in the MF barn was significantly lower, while relative humidity was higher than that of the NS barn. The temperature humidity index (THI) in both barns ranged from 79-85 throughout the periods of study. Cows in the MF barn showed a lower rectal temperature and respiration rate as compared with cows in the NS barn. The effect of rbST administration increased both rectal temperature and respiration rates of cows housed in either the NS or MF barn. Milk yield significantly increased in cows treated with rbST in all stages of lactation. Increases in mammary blood flow, accompanied by increases of total body water (TBW), extracellular fluid (ECF), blood volume (BV) and plasma volume (PV), were observed in both groups of cows receiving rbST in all stages of lactation. No alterations of renal blood flow and glomerular filtration rate were observed in cows receiving rbST, but decreases in urinary excretion and fractional excretion of sodium, potassium and chloride ions appeared to correlate with reduction in the rate of urine flow and osmolar clearance during rbST administration. These results suggest that the effect of rbST supplementation to cows housed either in NS or MF barns on body fluid volume expansion is attributable to changes in the rate of electrolyte excretion by the kidney. The increased availability of renal tubular reabsorption of sodium, potassium and chloride ions during rbST treatment was a major factor in retaining body water through its colligative properties in exerting formation of an osmotic force mechanism.

Design & Animal Experiment of Artificial Oxygenator (인공폐(산화기) 제작과 실험)

  • 김형묵
    • Journal of Chest Surgery
    • /
    • v.15 no.2
    • /
    • pp.259-265
    • /
    • 1982
  • We have designed a new type of bubble oxygenator (KOREA-KIM VENOTHERM OXYGENATOR) made of PVC sheet and deforming mesh incorporated in the heat exchanger, and evaluated in experimental animal for the analysis of it`s efficiency. The Oxygenator has low priming volume with high flow rate up to 6 L/rain, and efficiency of heat exchanger was excellent as 1-$1.5^{\circ}C.$ using total cardiopulmonary bypass method under moderate to deep hypothermia. Average priming volume of 1317 ml with 30% hemodilution method was perfused with an average of 1.1-3.0 L/min.$M^2$of arterial blood and pure oxygen at a rate of 2-3.4 L/min for 49.6 minutes continuously in average. During total cardiopulmonary bypass, average $PaO_2$ was $159.8{\pm}60$mmHg, $PaCO_2$ $41.0{\pm}3$mmHg respectively under $SaO_2$ over 96% with systolic arterial pressure of 70 mmHg and CVP of 5-10 cm$H_2O$. Plasma free Hemoglobin was $7.0{\pm}4$ mg/dl with 25% drop of hemoglobin and hematocrit at the end of cardiopulmonary bypass. This KKV Oxygenator was observed to have excellent capabillty of oxygen and carbon dioxide gas transfer with small amount of blood trauma, and the efficiency of heat exchanger was satisfactory during cooling and rewarming of the bubbled blood. Disadvantages have included the somewhat poor deforming effect due to loose PVC fiber mesh, the extracompact character of Teflon filters, and the rough inner surface of the heat exchanger copper pipes.

  • PDF

Changes in Cerebral Hemodynamics and Sympathetic System During a Combination of Subway Noise with Mental Activity

  • Park, Jae-Hyun;Hyun, Kyung-Yae;Choi, Seok-Cheol
    • Biomedical Science Letters
    • /
    • v.13 no.3
    • /
    • pp.231-237
    • /
    • 2007
  • Subway environments such as crowd, passenger's gab, or subway-generated mechanical noise may become a potential stressor. The present study was sought to determine whether subway noise with or without mental activity affects cerebral hemodynamics and sympathetic system. Fifty-four healthy volunteers were divided group I which underwent subway noise (n=24) and group II which underwent a combined mental activity (mental arithmetic) with subway noise (n=30). Sympathetic factors such as heart rate (HR), blood pressure (BP) and heart rate-systolic pressure product (RPP), and mean blood flow velocity in the middle cerebral artery (MCAV) were measured before (baseline), during and after the noise-exposure. Systolic and diastolic blood pressure, HR and RPP significantly increased in group II (P<0.05) but not in group I during the noise-exposure. Peak-MCAV, diastolic-MCAV and mean-MCAV in the both groups were elevated during the noise-exposure (P<0.05) and the increased ratios in group II were greater than those in group I. These results suggest that a combined mental activity with subway noise may be a stressor which affects cerebral hemodynamics and sympathetic system.

  • PDF

Experimental Investigation on Heat Transfer Characteristics in a Uniformly Heated Pipe with Pulsating Pressure (맥동 압력을 받는 가열관 내부에서의 열전달 특성에 관한 실험적 연구)

  • 이건태;강병하;이재헌;이춘식
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.9
    • /
    • pp.1760-1769
    • /
    • 1992
  • An experimental study of thermal transport from a uniformly heated pipe to a pulsating flow has been carried out. Surface of the pipe is imposed with constant heat flux providing by electric heating band. This problem is of particular interest in the design of Stirling engine heat exchangers and in understanding the blood flow in the aorta. Temporal Variatiens of temperature and pressure inside the circular pipe are measured. The dependence of temperature distributions and heat transfer rate on the mean flow rate in the pipe and on the pulsating frequency is investigated in detail. The experimental results indicate that the measured temporal variations of temperature and pressure become nearly sinusoidal The amplitude of temperature variation near the pipe wall is much more substantial than that in core of the pipe. It is also found that the heat transfer rate is increased significantly as the frequency of the pulsating pressure is increased or the mean flow rate in a pipe is increased. The results obtained are also compared with those for non-pulsating flow circumstance.

An Experiments Analysis of Comparison of Flow Gradients Across Disposable Arterial Perfusion Cannulas (일회용 각종 송혈관의 관류압차에 대한 비교실험)

  • Kim, Yo-Han;Kim, Hyeong-Muk
    • Journal of Chest Surgery
    • /
    • v.19 no.1
    • /
    • pp.18-24
    • /
    • 1986
  • The mean perfusion pressure produced by 20 different design and size of disposable aortic perfusion cannulas [size range: 18F to 20F] at flow rates of 1 to 5 L/min was compared. A roller pump with perfusion tubing 10mm in inner diameter was used with a mixture of 0.9% normal saline and 100% glycerin [mixing ratio of 6.72:13.28] to make the viscosity as normal blood in 20oC as the test solution. Line pressure in these cannulas at a flow rate of 3L/min ranged from 13.2$\pm$4.47 to 157$\pm$1 34 mmHg in a case of absence of resistance, and from 11.4$\pm$1.14 to 227.2$\pm$4.47 mmHg in a case of presence of resistances 14 cannulas had gradients of less than 100Hg at a flow rate of 3L/min and 9 cannulas less than 100mmHg at 4L/min. The following results were obtained from this experimental study: .1] A wide range of line pressure was observed in disposable aortic perfusion cannulas currently in clinical use; 2] Some cannulas currently used for cardiopulmonary bypass in adults generated excessive line pressure; 3] Both the material and design affect function, with some designs safer than others. Cardiac surgeons should base the choice of aortic perfusion cannula on the best performance and safest design available to avoid cannula-related problems during operation.

  • PDF

Influences of an Experimental Exposure to Excavator Noise on the Cardiac Factors and Cerebral Hemodynamics

  • Hyun Kyung-Yae;Choi Seok-Cheol;Oh Kwang-Seok;Kwon Heun-Young;Kim Jai-Young;Kim Tae-Un
    • Biomedical Science Letters
    • /
    • v.11 no.3
    • /
    • pp.397-405
    • /
    • 2005
  • Noise may cause damage of the auditory system, hypertension, and cardiovascular disease. However, we haven't the data enough to be available for understanding various effects of noise on the human body. The current study was prospectively designed to investigate the changes of the cardiac factors and cerebral hemodynamics following a transient exposure to noise in young people. 80 subjects (mean aged $23.45\pm2.40$ years) participated in this experiment and were exposed to excavator-noise with 90 decibels for 15 minutes using ear-phone. Cardiac factors such as heart rate (HR), blood pressure (BP) and heart rate-systolic pressure product (RPP), and cerebral hemodynamics such as mean blood flow velocities (Vm), pulsatility indexes (PI), resistance indexes (RI) and mean blood flow velocities at breathing-hold (Vh) in the middle (MCA), anterior (ACA) and posterior cerebral arteries (PCA) were measured before (baseline) and during the noise-exposure. Although there were individual differences in above mentioned parameters, HR, systolic and diastolic BP, RPP, MCA-Vm, MCA-PI, MCA-RI, ACA-Vm, ACA-PI, ACA-RI, PCA-Vm, PCA-PI, and PCA-RI during the noise-exposure decreased compared with the baselines (P<0.05 or P<0.01), The findings of the present study suggest that a transient exposure to excavator-noise at rest causes changes in the cardiac factors and cerebral hemodynamics with individual differences. Further studies need to be carried out for clarifying the effects of longer exposure and combined mental activity with noise exposure.

  • PDF

The Simple in Vivo Evaluation Method for Blood-Brain Barrier Permeability of Drugs in Mice (생쥐에 있어서 약물의 혈액-뇌 관문 투과성 평가를 위한 간편한 in vivo 방법)

  • Kang, Young-Sook;Kim, You-Jung
    • Journal of Pharmaceutical Investigation
    • /
    • v.30 no.2
    • /
    • pp.99-105
    • /
    • 2000
  • This study compared the permeability of $[^3H]taurine,\;[^3H]phenylalanine,\;and\;[^3H]oxytocin$ through the blood-brain barrier (BBB) in mice and rats with common carotid artery perfusion (CCAP) method that modified internal carotid artery perfusion (ICAP) method. External carotid artery (ECA) was cannulated with coagulating pterygopalatine artery (PPA) in ICAP method, while CCA was cannulated without coagulating PPA in CCAP method. Also, for evaluation of BBB permeability of drugs in mice and rats, we used intravenous injection technique. The results of CCAP method in mice at a perfusion flow-rate of 2 ml/min, the brian volume of distribution $(V_D)$ of $[^{14}C]sucrose,\;[^3H]taurine,\;[^3H]phenylalanine,\;and\;[^3H]oxytocin$ were similar to the result of ICAP method in rats at perfusion flow rate of 4 ml/min. The area under the plasma concentration-time curve and brain uptake of $[^3H]taurine$ by intravenous injection technique, were $65.5{\pm}9.7%ID^*min/ml\;and\;0.515{\pm}0.093%ID/g$, respectively, in mice, and the corresponding values were $8.00{\pm}0.03%ID^*min/ml\;and\;0.052{\pm}0.003%ID/g$ in rats. But the BBB permeability surface-area product of $[^3H]taurine$ was similar between mice and rats. In conclusion, the CCAP method in mice was simple, fast and comparable to ICAP method in rats for drug permeability through the BBB.

  • PDF

Asymptotic Expressions for One Dimensional Model of Hemodiafiltration

  • Chang, Ho-Nam;Park, Joong-Kon
    • Journal of Biomedical Engineering Research
    • /
    • v.5 no.1
    • /
    • pp.9-14
    • /
    • 1984
  • The asymptotic solution using the Tailor series has been given explicit form for the solute concentration and overall solute removal in hemodiafilter using one dimensional model. The numerical solutions have been calculated within 0.001% error by the Romberg integration method. Compared with the numerical solutions, the oneterm asymptotic solutions were found to be within 3% error for the condition > 3.0 and three-terms asymtotic solutions were required for the condition >0.7 where denotes measure of convection over diffusional transport and a the ratio of blood flow rate over dialysate flow rate.

  • PDF