• Title/Summary/Keyword: Blood Assay

Search Result 948, Processing Time 0.02 seconds

Evaluation of Rapid Immunochromatographic Assay Kit for HBsAg-Screening Using Whole Blood

  • Shin, Hyeong-Soon;Heo, Tae-Ryeon
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.5 no.5
    • /
    • pp.362-365
    • /
    • 2000
  • A rapid immunochromatographic assay kit using whole blood to screen hepatitis B surface antigen was developed and evaluated by using sera from 240 patients. The reference diagnosis was based on the results obtained with GENEDIA Anti-HBs Rapid kit which is very similar to the above kit except for the use of serum. The test demonstrated a good correlation with the reference immunochromatographic assay kit, that is, the sensitivity and the specificity of the kit was 100%, respectively. The rapid test kit using whole blood should be more convenient and useful for the diagnosis of hepatitis B virus because the kit does not need machines and time to prepare serum. In addition, this kit is safe from inadvertent infection during sample treatment because the blood is sterilized with hydrogen peroxide, eliminates the procedure required to prepare serum and reduces the possibility of exposure to infectious agents.

  • PDF

Effects of Curculiginis Rhizoma on anti-thrombotic activity (선모(仙茅) 열수(熱水) 추출물(抽出物)의 항혈전(抗血栓) 효능 연구)

  • Roh, Seong-Soo
    • The Korea Journal of Herbology
    • /
    • v.26 no.4
    • /
    • pp.125-132
    • /
    • 2011
  • Objectives : An aim of study is to investigate effects of curculiginis rhizoma in vitro (factor Xa (FXa) inhibitor assay, prothrombinase assay, prothrombin time (PT) assay, activated partial thromboplastin time (aPTT) assay) and in vivo experiment (blood clotting time, thromboxane B2 content assay in serum and weight of thrombus by AV-shunt rat model). Methods : We gained a human serum and used serum in vitro study such as factor X activity (FXa) inhibition, prothrombinase inhibition, prothrombin time (PT) and activated partial thromboplastin time. Fifteen SD rats were divided into three groups (intact control group and two experimental group treated with extract of Curculiginis Rhizoma(ECR)). Rats were orally administrated DW (intact control group), 600 mg/kg concertration of ECR and 200 mg/kg concertration of ECR. After one hour, we anesthetized rats and made arteriovenous (AV) shunt rat models to study weights of thrombus, took a hole blood to study content of thromboxane B2 and blood clotting time. Results : In vitro, ECR increased a inhibitory activity of FXa, prothrombinase and aPTT compared than intact control group. Especially ECR made significant increase of FXa and prothrombinase inhibitory activity (p<0.05, p<0.01). And PT were increased in ECR control group compared with intact control group. In vivo, a blood clotting time of experiment group treated with ECR 600 mg/kg were significantly increased compared with that of intact control group (p<0.05) and content of thromboxane B2 was significantly decreased in group treated with ECR 600 mg/kg in seum. The weight of thrombus were significantly reduced in group treated with ECR 600 mg/kg compared with intact control group (p<0.05). But in vivo experiment study, those of group treated with ECR 200 mg/kg were reduced compared with those of intact control group without statistical significance. Conclusions : ECR has a antithromboic activity in internal course with inhibitory activity of FXa and prothrombinase in vitro, it required to research more study for effective compounds.

In vivo Comet Assay on Flounder and Clam Exposed to BaP and TBT (BaP 및 TBT에 노출된 넙치와 개조개의 in vivo Comet assay)

  • Kim, So-Jung;Chung, Young-Jae;Lee, Taek-Kyun
    • Ocean and Polar Research
    • /
    • v.33 no.2
    • /
    • pp.127-133
    • /
    • 2011
  • The comet assay, also called single-cell electrophoresis (SCGE) assay, is a potential sensitive monitoring tool for DNA damage in cells. The primary objective of this study was to use comet assay to ascertain if the blood cells of flounder (Pleuronichthys olivaceus) and muscle cells of clam (Saxidomus purpurata) are suitable for genotoxicity screening. This was achieved by initially exposing blood and muscle cells under in vitro conditions to the reference genotoxin hydrogen peroxide ($H_2O_2$); strong correlation between $H_2O_2$ concentration and comet values were found. Subsequently, the identification of DNA damage in isolated cells from flounder and clam was performed under in vivo exposure to benzo(a)pyrene (BaP) and tributyltin (TBT). Flounder and clam were exposed to different concentrations (1, 10, 50, 100 ${\mu}g/L$) of BaP or TBT for 4 days. Regardless of treated chemicals, blood cells of flounder were more prone to DNA breakage compared to muscle cells of clam. In conclusion, in vivo genotoxicity of BaP and TBT can be biomonitored using the comet assay. This study suggests that flounder and clam do show potential as mediums for monitoring genotoxic damage by comet assay.

A Fluorescent Recombinase Aided Amplification Assay for Detection of Babesia microti

  • Lin, Hong;Zhao, Song;Ye, Yuying;Shao, Lei;Jiang, Nizhen;Yang, Kun
    • Parasites, Hosts and Diseases
    • /
    • v.60 no.3
    • /
    • pp.201-205
    • /
    • 2022
  • Babesia microti is one of the most common causative agents of babesiosis. A sensitive and rapid detection is necessary for screening potentially infected individuals. In this study, B. microti cytochrome c oxidase subunit I (cox1) was selected as the target gene, multiple primers were designed, and optimized by a recombinase-aided amplification (RAA) assay. The optimal primers and probe were labeled with fluorescein. The sensitivity of fluorescent RAA (fRAA) was evaluated using gradient diluents of the cox1 recombinant plasmid and genomic DNA extracted from whole blood of B. microti infected mice. The specificity of fRAA was assessed by other transfusion transmitted parasites. The analytical sensitivity of the fRAA assay was 10 copies of recombinant plasmid per reaction and 10 fg/µl B. microti genomic DNA. No cross-reaction with any other blood-transmitted parasites was observed. Our results demonstrated that the fRAA assay would be rapid, sensitive, and specific for the detection of B. microti.

Application of Single Cell Gel Electrophoresis for Detection of DNA Single Strand Breaks in DNA of Fish Blood Cell (어류혈구세포에 있어서 Single Cell Gel Electrophoresis를 응용한 DNA Single Strand Breack의 측정)

  • KIM Gi Beum;LEE Richard F.;MARUYA Keith A.
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.36 no.4
    • /
    • pp.346-351
    • /
    • 2003
  • Single-cell gel electrophoresis (comet assay) was used to detect DNA single strand break in blood cells from several marine fish species. Three fish species were collected from Georgia coastal area. Mummichog, Fundulus heteroclitus showed higher DNA damage than sea bass, Lateolabrax japonicus and trout, Oncorhynchus masou masou under the same experimental conditions. Mummichogs had more alkaline-labile sites on their DNA than other fish species. The comet assay with mummichog blood cells at pH 12.5 showed a dose-response curve with the increasing concentrations of hydrogen peroxide. While the isolated leucocytes showed no increase of DNA damage after in vitro exposure to 2-methyl-1,4-naphthoquinone (MNQ), erythrocytes showed dose-dependent DNA damage. These results indicate that the comet assay can be applied successfully as a bioassay using erythrocyte for environmental monitoring.

Detection of Acute Toxoplasmosis in Pigs Using Loop-Mediated Isothermal Amplification and Quantitative PCR

  • Wang, Yanhua;Wang, Guangxiang;Zhang, Delin;Yin, Hong;Wang, Meng
    • Parasites, Hosts and Diseases
    • /
    • v.51 no.5
    • /
    • pp.573-577
    • /
    • 2013
  • A loop-mediated isothermal amplification (LAMP) assay allows rapid diagnosis of Toxoplasma gondii infection. In the present study, the LAMP assay was evaluated using blood from both naturally and experimentally infected pigs. The sensitivity of the LAMP assay was compared with that of Q-PCR. Both assays detected T. gondii in the blood of experimentally infected pigs, with 100% agreement. In infected blood samples, the parasite was detected as early as 2 days post-infection and reached a peak in 3-5 days. In 216 field serum samples, the detection rates of LAMP and Q-PCR assays were 6.9% and 7.8%, respectively. This result indicates that the sensitivity of the LAMP assay was slightly lower than that of the Q-PCR assay. However, the LAMP may be an attractive diagnostic method in conditions where sophisticated and expensive equipment is unavailable. This assay could be a powerful supplement to current diagnostic methods.

A LAMP-SNP Assay Detecting C580Y Mutation in Pfkelch13 Gene from Clinically Dried Blood Spot Samples

  • Khammanee, Thunchanok;Sawangjaroen, Nongyao;Buncherd, Hansuk;Tun, Aung Win;Thanapongpichat, Supinya
    • Parasites, Hosts and Diseases
    • /
    • v.59 no.1
    • /
    • pp.15-22
    • /
    • 2021
  • Artemisinin resistance (ART) has been confirmed in Greater Mekong Sub-region countries. Currently, C580Y mutation on Pfkelch13 gene is known as the molecular marker for the detection of ART. Rapid and accurate detection of ART in field study is essential to guide malaria containment and elimination interventions. A simple method for collection of malaria-infected blood is to spot the blood on filter paper and is fast and easy for transportation and storage in the field study. This study aims to evaluate LAMP-SNP assay for C580Y mutation detection by introducing an extra mismatched nucleotide at the 3' end of the FIP primer. The LAMP-SNP assay was performed in a water bath held at a temperature of 56℃ for 45 min. LAMP-SNP products were interpreted by both gel-electrophoresis and HNB-visualized changes in color. The method was then tested with 120 P. falciparum DNA from dried blood spot samples. In comparing the LAMP-SNP assay results with those from DNA sequencing of the clinical samples, the 2 results fully agreed to detect C580Y. The sensitivity and specificity of the LAMP-SNP assay showed 100%. There were no cross-reactions with other Plasmodium species and other Pfkelch13 mutations. The LAMP-SNP assay performed in this study was rapid, reliable, and useful in detecting artemisinin resistance in the field study.

Antidiabetic Activity of an Ayurvedic Formulation Chaturmukha Rasa: A Mechanism Based Study

  • Sharma, Akansha;Tiwari, Raj K;Sharma, Vikas;Pandey, Ravindra K;Shukla, Shiv Shnakar
    • Journal of Pharmacopuncture
    • /
    • v.22 no.2
    • /
    • pp.115-121
    • /
    • 2019
  • Objectives: The objective of this study was to evaluate antidiabetic activity of Chaturmukha rasa based on streptozotocin induced diabetes model, alpha amylase inhibitory activity, alpha Glucosidase inhibitory activity and inhibition of sucrase. Methods: Chaturmukha rasa was prepared as per Ayurvedic formulary. Antidiabetic activity was measured in experimentally streptozotocin induced rats. The dose was taken as 45 mg/kg, i.p. The antidiabetic activity of Chaturmukha rasa was compared Triphala Kwatha, a marketed formulation. Further In vitro $\acute{\alpha}$- Amylase Inhibitory Assay, In vitro salivary amylase Inhibitory Assay, In vitro ${\alpha}-Glucosidase$ Inhibitory Assay and In vitro Sucrase Inhibitory Assay was performed with respect to Chaturmukha rasa. The IC50 value was calculated for all the above activity. Results: Streptozotocin with Acarbose showed significant decrease in blood glucose level whereas streptozotocin with Triphala kwatha showed more decrease in blood glucose level than Streptozotocin with Acarbose. The combination of Streptozotocin + Triphala kwatha + Chaturmukha rasa showed a significant decrease in blood glucose level on 21st day. In vitro $\acute{\alpha}$- Amylase Inhibitory Assay the Chaturmukha rasa showed IC50 value $495.94{\mu}l$ when compared with Acarbose $427.33{\mu}l$, respectively. In the ${\alpha}-Glucosidase$ Inhibitory Assay Chaturmukha rasa showed IC50 value $70.93{\mu}l$ when compared with Acarbose $102.28{\mu}l$, respectively. In vitro Sucrase Inhibitory Assay Chaturmukha rasa showed IC50 value $415.4{\mu}l$ when compared with Acarbose $371.43{\mu}l$, respectively. Conclusion: This study supports that Chaturmukha rasa may inhibit diabetes by inhibition of salivary amylase or alpha Glucosidase or sucrase. This may be the mechanism by which Chaturmukha rasa inhibits diabetes. Further this study supports the usage of Chaturmukha rasa for the management of diabetes.

DNA Damage and Micronuclei Induced by Di (2-ethylhexyl) phthalate in Human Breast Carcinoma MCF-7 cells (Di(2-ethylhexyl) phthalate에 의해 유도된 DNA손상과 소핵 형성)

  • 김종원;한의식;박미선;엄미옥;김인숙;전혜승;정해관;심웅섭;오혜영
    • Environmental Mutagens and Carcinogens
    • /
    • v.21 no.1
    • /
    • pp.34-43
    • /
    • 2001
  • Di-2-ethylhexyl phthalate (DEHP) is the most commonly used phthalate ester in polyvinyl chloride formulations including food packing and storage of human blood. DEHP is a well known as non-genotoxic carcinogen and endocrine disrupting chemical (EDC). DEHP have shown all negative results in ICH-guildeline recommended standard genotoxicity test battery. In this study, to assess the clastogenic and DNA damaging effect in human-derived tissue specific cells, DEHP was treated in human derived MCE-7 cells, HepG2 cells, LNCap cells, BeWo cells, MCE-10A cells, and female peripheral blood cells using micronucleus assay and in human breast carcinoma MCF-7 cells up to $1.28$\times$10^{-2}$ M using Comet assay. The in vitro micronucleus assay is a mutagenicity test system for the detection of chemicals which induce the formation of small membrane bound DNA fragment i.e. micronuclei in the cytoplasm of interphase cells, originated from clastogenic and/or aneugenic mechanism. The single cell gel electrophoresis assay (Comet assay) is used to detect DNA strand-breaks and alkaline labile site. In our results, DEHP increased significantly and/or dose-depentently and time-dependently micronucleus frequency at the 6 and 24 hr without metabolic activation system only in MCE-7 cells. DEHP treated with 2 hrs in MCF-7 cells using Comet assay induced DNA damage dose-depentantly.

  • PDF

Radiation exposure dose in human blood lymphocytes as assessed by the CBMN assay

  • Ryu, Tae Ho;Kim, Jin-Hong;Kim, Jin Kyu
    • Journal of Ecology and Environment
    • /
    • v.37 no.4
    • /
    • pp.195-200
    • /
    • 2014
  • The chances of accidental exposure are augmented as the application of ionizing radiation increases in various fields. Such accidental exposures may occur at nuclear power plants, laboratories, and hospitals. Cytogenetic assays have been used for estimating radiation dose in the situation of the accidents. The micronucleus assay has several advantages over the other cytogenetic methods as it is simple and fast. The present study aimed at investigation of the micronuclei frequencies in cytokinesis-block cells in human blood lymphocytes after ${\gamma}$-irradiation and at establishment of a standard dose response relationship. The samples of peripheral blood were obtained from 6 different donors aged between 24 and 30 years old. The bloods were irradiated in vitro with 0-5 Gy. A linear quadratic dose-response equation was obtained by scoring the micronuclei in binucleated cells; $y=27.87x^2+46.13x+2.08$ ($r^2=0.99$). Irradiation caused a significant decrease in the nuclear division index. Necrotic and apoptotic cells increased in number after irradiation in a dose-dependent manner. In conclusion, the conventional cytokinesis-block micronucleus assay has proven to be the great technique in biological dosimetry. Dose-response calibration curve derived from CMBN assay could be used to estimate the exposure dose during a radiological emergency.