• Title/Summary/Keyword: Blood Analysis

Search Result 4,899, Processing Time 0.041 seconds

The Effect of Brisk Walking Exercise Program on Body Composition, Blood Pressure, Blood Glucose and Blood Lipid for Middle-aged Woman with Obesity (걷기 프로그램이 비만 중년여성의 체성분, 혈압, 혈당 및 혈중지질에 미치는 효과)

  • Hyoung, Hee-Kyoung;Kim, Hee-Sun
    • Journal of Korean Biological Nursing Science
    • /
    • v.10 no.1
    • /
    • pp.62-68
    • /
    • 2008
  • Purpose: This study was conducted to test the effect of the 12 weeks brisk walking exercise program on body composition, blood pressure, blood glucose and blood lipid for middle-aged woman with obesity. Method: The subject were 25 obese women in 40-64 yr old who were composed of over 30% body fat. For the analysis, descriptive statistics, paired t-test were used for statical analysis with SPSS 15.0. Result: The results were summarized as follows: first, the body weight, body mass index (BMI), % body fat of the obese woman were significantly decreased after implementing the 12 weeks brisk walking exercise program (p<.5). Second, the systolic blood pressure, diastolic blood pressure and blood glucose were significantly decreased after the 12 weeks brisk walking exercise program (p<.5). Third, the serum cholesterol was significantly decreased (p<.05) but serum triglyceride was not significantly decreased the after 12 weeks brisk walking exercise program. Conclusion: These results suggest that the brisk walking exercise program has an effect on decreasing body weight, BMI, percent body fat, blood pressure and serum cholesterol in middle-aged woman with obesity to reduce obesity and prevent chronic disease.

  • PDF

A Study on Blood Flow Measurement Method using Independent Component Analysis (독립성분분석을 이용한 혈류 속도 측정 방법에 관한 연구)

  • Cho, Seog-Bin;Lim, Dong-Seok;Baek, Kwang-Ryul
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.2 s.314
    • /
    • pp.10-17
    • /
    • 2007
  • The echo signal on ultrasonic transducer is a mixed signal from tissues, blood vessel walls, blood cells and noise. In this mixed-signal, the signal reflected from tissues and blood vessel walls is called clutter. It is necessary to extract pure blood signal from this mixed-signal, when measuring blood flow velocity with medical ultrasonic system The quality of measured blood flow velocity is highly dependent on sufficient attenuation of the clutter signals. In this paper, we suggest a clutter rejection method using ICA For simulation, the echo signals are generated by Field n ultrasonic simulation program In this echo signals, independent signals are separated by using ICA Then the blood signal is obtained from the separated signals. Blood flow velocity is measured by 2D autocorrelation method. We compare ICA clutter rejection method with PCA-based eigen filter method using both measured blood flow velocity profiles by 2D autocorrelation. In simulation results, ICA clutter rejection method can be better applied measuring blood flow velocity in noisy echo signals.

3-D Flow Analysis of Blood and Blood Substitutes in a Double Branching Model (이중 분지관내 혈액 및 혈액대용유체의 3차원 유동해석)

  • Suh, Sang-Ho;Yoo, Sang-Sin;Roh, Hyung-Woon
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.2
    • /
    • pp.187-196
    • /
    • 1997
  • The three-dimensional flow analysis using the finite volume method is presented to compare the steady flow characteristics of blood with those of blood substitutes such as water and aqueous polymer solution in an idealized double branching model. The model is used to simlllate the region of the abdominal aorta near the celiac and superior mesenteric branches. Apparent viscosities of blood and the aqueous Separan solution are represented as a function of shear rate by the Carreau model, Water and aqueoiu Separan AP-273 500wppm solution are frequently used as blood substitutes in vitro experiments. Water is a typical Newtonian fluid and blood and Separan solution are non-Newtonian fluids. Flow phenomena such as velocity distribution, pressure variation and wall shear stress distribution of water, blood and polymer solution are quite different due to differences of the rheological characteristics of fluids. Flow phenomena of polymer solution are qualitatively similar to those of blood but the phenomena of water are quite different from those of blood and polymer solution. It is recommended that a lion-Newtonian fluid which exhibits very similar rheological behavior to blood be used in vitro experiments. A non-Newtonian fluid whose rheological characteristics are very similar to those of blood should be used to obtain the meaninylll hemodynamic data for blood flow in vitro experiment and by numerical analysis

  • PDF

Effect of Physical Activity on Blood Sugar Control in Young and Middle-aged Diabetic Patients Using the 8th Korea National Health and Nutrition Examination Survey Data (국민건강영양조사 자료를 이용한 청년 및 중·장년층 당뇨병 환자의 신체활동량이 혈당조절에 미치는 영향 분석)

  • Tae-Hyeon Lee;Il-Su Park
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.12 no.3
    • /
    • pp.227-236
    • /
    • 2024
  • Purpose : The number of young patients with diabetes is on the rise, and they face challenges in managing their blood sugar levels. This study aimed to investigate the effect of physical activity on blood sugar control in young and middle-aged patients with diabetes aged 19-64 years using data from the 8th Korea National Health and Nutrition Examination Survey (2019-2021). Methods : Blood sugar control in patients with diabetes was determined based on FBG 110 mg/㎗, and physical activity was measured using physical activity categories that considered the sum of walking, moderate intensity, and high intensity. Statistical analysis was conducted using SAS 9.4, and the Rao-Scott chi-square test was conducted to determine differences in blood sugar control based on the sociodemographic characteristics and physical activity of patients with diabetes. Complex-sample multiple logistic regression analysis was conducted to assess the effect of physical activity on blood sugar control. Results : There were statistically significant differences in blood sugar control between young and middle-aged patients with diabetes, depending on sex, age, marital status, obesity, and amount of physical activity. As a result of the complex sample simple logistic regression analysis without adjusting for variables, the non-physical activity group was found to have a higher risk of blood sugar dysregulation than the health-promoting physical activity group (OR: 2.80). Complex-sample multiple logistic regression analysis with control variables showed that the non-physical activity group had a higher risk of blood sugar dysregulation than the health-promoting physical activity group (OR: 3.70). Conclusion : Multifaceted efforts are needed to develop health intervention programs that can increase physical activity, diabetes awareness, and treatment rates, including controlling blood sugar levels and preventing complications in young and middle-aged patients with diabetes.

Simultaneous Analysis of 17 Organophosphorous Pesticides in Blood by Automated Head Space-SPME GC/MS (HS-SPME-GC/MS에 의한 혈액중 17종 유기인계 농약의 동시분석법)

  • Rhee, Jong-Sook;Jung, Jin-Mi;Lee, Han-Sun;Yeom, Hye-Sun;Lee, Sang-Ki;Park, Yoo-Sin;Chung, Hee-Sun
    • YAKHAK HOEJI
    • /
    • v.54 no.6
    • /
    • pp.429-440
    • /
    • 2010
  • HS-SPME-GC/MS was studied and optimized for the determination of 17 orgarnophosphorous pesiticides (OPPs: chlorpyrifos, chlorpyrifos-methyl, demeton-s-methyl, diazinon, dimethoate, EPN, fenitrothion, fenthion, malathion, methidathion, monocrotophos, parathion, phenthoate, phosphamidon, sulfotep, terbufos, triazophos) in blood. Optimum SPME parameters were selected: choice of SPME fiber (85 ${\mu}m$ polyacrylate), pH effect (0.5 N HCl), salt effect ($Na_2SO_4$, 0.2 g; 20%), headspace incubation temperature ($80^{\circ}C$), headspace incubation time (1 min), headspace adsorption time (30 min) and GC desorption time (2 min). These parameters were optimized using HS-SPME autosampler coupled with gas chromatography-mass spectrometry (GC-MS). Method validation was carried out in terms of linearity, limit of detection (LOD), limit of quantitation (LOQ) and recovery in blood. The assay was linear over 0.5~5.0 mg/l ($r^2$=0.955~1.000). Limit of detection (LOD) and limit of quantitation (LOQ) in blood were determined 0.03~0.3 mg/l (S/N=3) and 0.1~1.1 mg/l (S/N=10), respectively. Relative recovery with 0.5, 1 and 5 mg/l (in blood) were 90.8%, 98.5% and 94.1%, respectively. This method will be applied to the determination of the orgarnophosphorous pesticides in postmortem blood. The proposed protocol can be an attractive alternative to be used in routine toxicological analysis.

Development of Questionnaires for Blood Stasis Pattern (어혈변증설문지(瘀血辨證設問紙) 개발(開發))

  • Yang, Dong-Hoon;Park, Yong-Jae;Lee, Sang-Chul;Park, Young-Bae
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.10 no.1
    • /
    • pp.141-152
    • /
    • 2006
  • Background and Objectives: The diagnosis of flood stasis pattern is one of the most important methods in oriental medicine. The aim of this study is to Develop clinically useful questionaire of Blood stasis(瘀血) and quantitative analysis. Methods: The questionnaire including symptoms and signs for diagnosis of Blood stasis pattern is studied by delphi method and statistical analysis. Result: By the delphi method and statistical analysis, 14 Items of questionnaries are choosen. Conclusion: Further research is necessary for improvement reliabilities and validities of the questionnaires of Blood stasis pattern.

  • PDF

Numerical analysis of blood flow in the cactus type KTAH (선인장 형태의 한국형 인공심장 내 3차원 혈류의 수치적 해석)

  • Park M.S.;Ko H.J.;Min B.G.;Shim E.B.
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.695-696
    • /
    • 2002
  • Three-dimensional blood flow in the sac of the KTAH(Korean total artificial heart) is simulated using fluid-structure interaction model. The aim of this study is to delineate the three-dimensional unsteady-blood flow in the sac of KTAH. Incompressible viscous flow is assumed for blood using the assumption of Newtonian fluid. The numerical method employed in this study is the finite element software called ADINA. Fluid-structure interaction model between blood and sac is utilized to represent the deformation of the sac by the rigid moving actuator. Three-dimensional geometry of cactus type KTAH is chosen for numerical model with prescribed pressure boundary condition on the sac surface. Blood flow is generated by the motion of moving actuator and strongly interacts with the solid material surrounding blood. High shear stress is observed mainly near the inlet and outlet of the sac.

  • PDF

Ecological health assessments using multiple parameters of fish blood tissues to community along with water chemistry in urban streams

  • Kang, Han-il;Choi, Ji-Woong;Hwang, Seock-Yeon;An, Kwang-Guk
    • Journal of Ecology and Environment
    • /
    • v.38 no.3
    • /
    • pp.307-318
    • /
    • 2015
  • The objectives of this study were to identify multi-level stressors from blood biomarkers to community-level bioindicators and diagnose the stream ecosystem health in polluted streams. Blood chemistry such as total protein ($T_{Pro}$), blood urea nitrogen ($B_{UN}$), total cholesterol ($T_{Cho}$) and $A_{lb}$umin ($A_{lb}$) were analyzed from sentinel fish tissues; the functions of kidney, gill and liver were significantly decreased in the impacted zone ($I_z$), compared to the control zone ($C_z$). Histopathological analysis showed that fish liver tissues were normal in the $C_z$. Fish liver tissues in the $I_z$, however, showed large cell necrosis and degeneration and also had moderate lobular inflammation and inflammatory cell infiltration of lymphocytic histocytes. Species biotic index (SBI) at species level and stream health assessment (SHA) at community level indicated that chemical impacts were evident in the $I_z$ (ecological health; poor - very poor), and this was matched with the blood tissue analysis and histopathological analysis. The impairments of the streams were supported by water chemistry analysis (nitrogen, phosphorus). Tolerance guild analysis and trophic guild analysis of fish were showed significant differences (P < 0.01) between $C_z$ and $I_z$. Overall, multiple parameter analysis from biomarker level (blood tissues) to bioindicator level (community health) showed significantly greater impacts in the $I_z$ than $C_z$. This approach may be effective as a monitoring tool in identifying the multilateral and forthcoming problems related to chemical pollution and habitat degradation of stream ecosystems.

Classification of White Blood Cell Using Adaptive Active Contour

  • Theerapattanakul, J.;Plodpai, J.;Mooyen, S.;Pintavirooj, C.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1889-1891
    • /
    • 2004
  • The differential white blood cell count plays an important role in the diagnosis of different diseases. It is a tedious task to count these classes of cell manually. An automatic counter using computer vision helps to perform this medical test rapidly and accurately. Most commercial-available automatic white blood cell analysis composed mainly 3 steps including segmentation, feature extraction and classification. In this paper we concentrate on the first step in automatic white-blood-cell analysis by proposing a segmentation scheme that utilizes a benefit of active contour. Specifically, the binary image is obtained by thresolding of the input blood smear image. The initial shape of active is then placed roughly inside the white blood cell and allowed to grow to fit the shape of individual white blood cell. The white blood cell is then separated using the extracted contour. The force that drives the active contour is the combination of gradient vector flow force and balloon force. Our purposed technique can handle very promising to separate the remaining red blood cells.

  • PDF

Association between Prostaglandin-endoperoxide Synthase 2 (PTGS2) Polymorphisms and Blood Pressure in Korean Population

  • Jin, Hyun-Seok;Hong, Kyung-Won;Lim, Ji-Eun;Han, Hye-Ree;Lee, Jong-Young;Park, Hun-Kuk;Oh, Berm-Seok
    • Genomics & Informatics
    • /
    • v.6 no.3
    • /
    • pp.110-116
    • /
    • 2008
  • Blood pressure refers to the force exerted by circulating blood on the walls of blood vessels, and chronical elevation of blood pressure is known as hypertension. Although hypertension is affected by genetic and environmental factors, the genetic background of hypertension is not fully understood. One of the candidate genetic factors, Prostaglandin-endoperoxide synthase 2 (PTGS2), is a membrane-bound enzyme, catalyzing the conversion of arachidonic acid to prostaglandin, and recently SNPs of PTGS2 gene was associated with hypertension in Japanese population. Therefore the association of PTGS2 polymorphisms was investigated with blood pressure in healthy Korean subjects, 470 unrelated individuals randomly selected from Ansung and Ansan cohorts. The 25 SNPs of PTGS2 gene were identified by the sequencing analysis of 24 Korean samples. Among identified polymorphisms, three SNPs (rs689466, -1329A>G; rs5275, +6365T>C; rs4648308, +8806G> A) were selected for further association analysis, and rs689466 located in promoter region was associated with blood pressure as well as triglyceride level in the blood. By in silico analysis, rs689466 locates in v-Myb transcription factor binding site, and the v-Myb site disappears when the SNP is changed from A to G nucleotide. Individuals with A/G and G/G genotype in rs689466 have higher blood pressure than those with A/A genotype, and the regression p-value is 0.008 for systolic and 0.004 for diastolic blood pressure. In summary, the PTGS2 polymorphism (rs689466) is associated with blood pressure in Asian populations based on this and Japanese studies, shedding light on it as a genetic risk marker of hypertension.